SN55113FK [TI]
DUAL DIFFERENTIAL LINE DRIVERS; 双路差分线路驱动器型号: | SN55113FK |
厂家: | TEXAS INSTRUMENTS |
描述: | DUAL DIFFERENTIAL LINE DRIVERS |
文件: | 总12页 (文件大小:214K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
SN55113 . . . J OR W PACKAGE
SN75113 . . . N PACKAGE
(TOP VIEW)
Choice of Open-Collector, Open-Emitter, or
3-State Outputs
High-Impedance Output State for
Party-Line Applications
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
1ZP
1ZS
1YS
1YP
1A
1B
1C
GND
CC
Single-Ended or Differential AND/NAND
Outputs
2ZP
2ZS
2YS
2YP
2A
Single 5-V Supply
Dual Channel Operation
Compatible With TTL
2C
CC
Short-Circuit Protection
High-Current Outputs
Common and Individual Output Controls
Clamp Diodes at Inputs and Outputs
SN55113 . . . FK PACKAGE
(TOP VIEW)
Easily Adaptable to SN55114 and SN75114
Applications
Designed for Use With SN55115 and
SN75115
3
2
1
20 19
18
2ZS
2YS
NC
4
5
6
7
8
1YS
1YP
NC
1A
17
16
15
14
description
2YP
2A
The SN55113 and SN75113 dual differential line
drivers with 3-state outputs are designed to
provide all the features of the SN55114 and
SN75114 line drivers with the added feature of
driver output controls. Individual controls are
provided for each output pair, as well as a
commoncontrolforbothoutputpairs. Ifanyoutput
1B
9 10 11 12 13
NC – No internal connection
is low, the associated output is in a high-impedance state and the output can neither drive nor load the bus. This
permits many devices to be connected together on the same transmission line for party-line applications.
The output stages are similar to TTL totem-pole outputs, but with the sink outputs, YS and ZS, and the
corresponding active pullup terminals, YP and ZP, available on adjacent package pins.
The SN55113 is characterized for operation over the full military temperature range of –55°C to 125°C. The
SN75113 is characterized for operation over the temperature range of 0°C to 70°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 1997, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
FUNCTION TABLE
INPUTS
OUTPUTS
AND NAND
DATA
OUTPUT
C
CONTROL
CC
†
B
Y
Z
Z
L
Z
Z
Z
H
H
L
A
L
X
H
H
H
X
L
X
X
L
X
X
X
L
H
H
H
X
H
L
H
H
H = high level, L = low level, X = irrelevant,
Z = high impedance (off)
†
B input and 4th line of function table are applicable only to
driver number 1.
‡
logic diagram (positive logic)
logic symbol
7
7
&
&
1C
CC
2C
1C
EN1
EN2
4
3
9
9
1YP
1YS
CC
10
2C
10
1
2
4
3
1ZP
1ZS
5
&
1
1
1
1
2
2
2
2
1YP
1YS
1ZP
1ZS
2YP
2YS
2ZP
2ZS
1A
5
6
1A
1B
1
6
12
13
1B
2
2YP
2YS
12
13
15
14
11
2A
11
15
14
2A
2ZP
2ZS
‡
This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Pin numbers shown are for the J, N, and W packages.
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
schematic
Input 1A
5
Input 1B
6
16
V
CC
†
600 Ω
1 kΩ
1 kΩ
4 kΩ
V
V
To
Other
Driver
†
600 Ω
‡
600 Ω
4 kΩ
9 Ω
4 kΩ
9 Ω
AND
Pullup
1YP
4
3
NAND
Pullup
1ZP
1
900 Ω
5 kΩ
900 Ω
90 Ω
†
†
333 Ω
100 Ω
100 Ω
5 kΩ
AND
Sink
Output
1YS
90 Ω
NAND
Sink
Output
1ZS
2
500 Ω
500 Ω
100 Ω
100 Ω
9
Common Output
Control CC
1.6 kΩ
V
4 kΩ
12
13
10
11
AND Pullup 2YP
AND Output 2YS
Output Control 2C
Input 2A
Output
Control
1C
7
15
14
NAND Pullup 2ZP
NAND Output 2ZS
1 kΩ
8
GND
V
... V
bus
CC
†
These components are common to both drivers. Resistor values shown are nominal and in ohms.
‡
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
I
Off-state voltage applied to open-collector outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V
Continuous total power dissipation (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, T : SN55113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
A
SN75113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: N package . . . . . . . . . . . . . . . . . . . . . 260°C
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J or W package . . . . . . . . . . . . . . . . 300°C
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
T
≤ 25°C
DERATING FACTOR
T
= 70°C
T = 125°C
A
POWER RATING
A
A
PACKAGE
POWER RATING
ABOVE T = 25°C
POWER RATING
A
FK
J
1375 mW
11.0 mW/°C
11.0 mW/°C
9.2 mW/°C
8.0 mW/°C
880 mW
275 mW
1375 mW
880 mW
275 mW
N
1150 mW
736 mW
N/A
W
1000 mW
640 mW
200 mW
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
recommended operating conditions
SN55113
SN75113
UNIT
MIN NOM
MAX
MIN NOM
MAX
Supply voltage, V
CC
High-level input voltage, V
4.5
2
5
5.5
4.75
2
5
5.25
V
V
IH
Low-level input voltage, V
0.8
– 40
40
0.8
– 40
40
V
IL
High-level output current, I
mA
mA
°C
OH
OL
Low-level output current, I
Operating free-air temperature, T
–55
125
0
70
A
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
SN55113
SN75113
†
PARAMETER
UNIT
V
TEST CONDITIONS
I = –12 mA
‡
‡
MIN TYP
MAX
MIN TYP
MAX
V
V
Input clamp voltage
V
= MIN,
= MIN,
–0.9
3.4
–1.5
–0.9
3.4
–1.5
IK
CC
I
I
I
= –10 mA
= –40 mA
2.4
2
2.4
2
High-level output
voltage
V
V
V
IH
= 2 V,
OH
CC
IL
V
OH
= 0.8 V
3.0
3.0
OH
Low-level output
voltage
V
= MIN,
= 40 mA
V
= 2 V,
V
= 0.8 V,
CC
IH
IL
V
V
0.23
0.4
0.23
–1.1
0.4
V
V
OL
I
OL
Output clamp voltage
V
CC
= MAX,
I
O
= – 40 mA
–1.1
1
–1.5
10
–1.5
OK
T
A
= 25°C
= 125°C
= 25°C
= 70°C
V
= 12 V
OH
OH
Off-state
open-collector output
current
T
A
200
I
V
CC
= MAX
µA
O(off)
T
A
1
10
20
V
= 5.25 V
T
A
T
= 25°C,
V
= 0 to V
= 0
±10
–150
±80
±80
80
±10
–20
±20
±20
20
A
O
V
CC
V
= MAX,
CC
O
Off-state
(high-impedance-state)
output current
Output
controls at
0.8 V
I
I
V
= 0.4 V
= 2.4 V
µA
OZ
O
T
A
= MAX
V
O
O
V
= V
CC
Input current
at maximum
input voltage
A, B, C
CC
1
2
1
2
V
CC
= MAX,
V = 5.5 V
I
mA
I
A, B, C
CC
40
80
40
80
High-level
input current
I
I
I
I
V
V
V
= MAX,
= MAX,
= MAX,
V = 2.4 V
µA
mA
mA
mA
IH
CC
CC
CC
I
A, B, C
CC
–1.6
–3.2
–1.6
–3.2
Low-level
input current
V = 0.4 V
I
IL
Short-circuit
output current
V
O
= 0,
T = 25°C
A
–40
–90 –120
–40
–90 –120
OS
CC
§
V
CC
= MAX
= 7 V
47
65
65
85
47
65
65
85
Supply current
(both drivers)
All inputs at 0 V, No load,
= 25°C
T
A
V
CC
†
All parameters with the exception of off-state open-collector output current are measured with the active pullup connected to the sink output. For
conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡
§
All typical values are at T = 25°C and V
Only one output should be shorted at a time, and duration of the short-circuit should not exceed one second.
= 5 V, with the exception of V
at 7 V.
A
CC
CC
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
switching characteristics, V
= 5 V, C = 30 pF, T = 25°C
CC
L
A
SN55113
TYP MAX
SN75113
MIN TYP MAX
PARAMETER
TEST CONDITIONS
UNIT
MIN
t
t
t
t
t
t
Propagation delay time, low-to-high level output
13
12
7
20
20
15
30
20
35
13
12
7
30
30
20
40
30
35
ns
ns
ns
ns
ns
ns
PLH
PHL
PZH
PZL
PHZ
PLZ
See Figure 1
Propagation delay time, high-to-low-level output
Output enable time to high level
R
R
R
R
= 180 Ω, See Figure 2
= 250 Ω, See Figure 3
= 180 Ω, See Figure 2
= 250 Ω, See Figure 3
L
L
L
L
Output enable time to low level
14
10
17
14
10
17
Output disable time from high level
Output disable time from low level
PARAMETER MEASUREMENT INFORMATION
1 kΩ
5 V
AND
Output
Input
C
= 30 pF
L
(see Note B)
Pulse
Generator
(see Note A)
NAND
Output
50 Ω
C
= 30 pF
L
(see Note B)
TEST CIRCUIT
≤ 5 ns
≤ 5 ns
3 V
0 V
90%
1.5 V
90%
1.5 V
Input
10%
10%
t
PHL
t
PLH
V
OH
NAND
Output
1.5 V
1.5 V
PHL
V
V
OL
t
PLH
t
OH
AND
Output
1.5 V
1.5 V
V
OL
VOLTAGE WAVEFORMS
NOTES: A. The pulse generator has the following characteristics: Z = 50 Ω, PRR ≤ 500 kHz, t = 100 ns.
O
w
B.
C includes probe and jig capacitance.
L
Figure 1. Test Circuit and Voltage Waveforms t
and t
PHL
PLH
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
PARAMETER MEASUREMENT INFORMATION
Input
Pulse
Generator
(see Note A)
5 V
AND
50 Ω
Output
R
L
180 Ω
C
= 30 pF
L
(see Note B)
Output
NAND
Output
C
= 30 pF
L
(see Note B)
1 kΩ
5 V
TEST CIRCUIT
≤ 5 ns
≤ 5 ns
3 V
0 V
90%
1.5 V
90%
Input
1.5 V
10%
10%
t
PZH
V
OH
Output
1.5 V
0.5 V
V
off
≈ 0 V
t
PHZ
VOLTAGE WAVEFORMS
NOTES: A. The pulse generator has the following characteristics: Z = 50 Ω, PRR ≤ 500 kHz, t = 100 ns.
O
w
B.
C includes probe and jig capacitance.
L
Figure 2. Test Circuit and Voltage Waveforms t
and t
PHZ
PZH
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
PARAMETER MEASUREMENT INFORMATION
Input
Pulse
Generator
(see Note A)
5 V
50 Ω
R
250 Ω
L
AND
5 V
1 kΩ
Output
C
= 30 pF
L
(see Note B)
NAND
Output
Output
C
= 30 pF
L
(see Note B)
TEST CIRCUIT
≤ 5 ns
≤ 5 ns
3 V
0 V
90%
1.5 V
90%
1.5 V
Input
10%
10%
t
PZL
t
PLZ
5 V
1.5 V
0.5 V
Output
V
OL
VOLTAGE WAVEFORMS
NOTES: A. The pulse generator has the following characteristics: Z = 50 Ω, PRR ≤ 500 kHz, t = 100 ns.
O
w
B.
C includes probe and jig capacitance.
L
Figure 3. Test Circuit and Voltage Waveforms, t
and t
PLZ
PZL
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
†
TYPICAL CHARACTERISTICS
OUTPUT VOLTAGE
vs
OUTPUT VOLTAGE
vs
DATA INPUT VOLTAGE
DATA INPUT VOLTAGE
6
5
4
3
2
1
0
6
5
4
3
2
1
0
V
= 5 V
No Load
= 25°C
CC
No Load
T
A
T
= 125°C
A
V
= 5.5 V
CC
V
V
= 5 V
CC
= 4.5 V
CC
T
= 25°C
A
T
= – 55°C
A
0
1
2
3
4
0
1
2
3
4
V – Data Input Voltage – V
I
V – Data Input Voltage – V
I
Figure 4
Figure 5
OUTPUT VOLTAGE
vs
OUTPUT VOLTAGE
vs
INPUT VOLTAGE (OUTPUT CONTROL)
INPUT VOLTAGE (OUTPUT CONTROL)
6
5
4
3
2
1
0
6
5
4
3
2
1
0
Load = 500 Ω to GND
= 25°C
V
= 5 V
CC
Load = 500 Ω to GND
T
A
T
= 125°C
A
V
= 5.5 V
CC
V
V
= 5 V
CC
= 4.5 V
CC
T
= 25°C
A
T
A
= – 55°C
High
Disabled
Disabled
High
0
1
2
3
4
0
1
2
3
4
V – Input Voltage (Output Control) – V
I
V – Input Voltage (Output Control) – V
I
Figure 6
Figure 7
†
8
Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55113 circuits
only. These parameters were measured with the active pullup connected to the sink output.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
†
TYPICAL CHARACTERISTICS
OUTPUT VOLTAGE
OUTPUT VOLTAGE
vs
vs
INPUT VOLTAGE (OUTPUT CONTROL)
INPUT VOLTAGE (OUTPUT CONTROL)
6
5
4
3
2
1
0
6
5
4
3
2
1
0
V
V
= 5.5 V
= 5 V
CC
Load = 500 Ω to V
CC
Load = 500 Ω to V
CC
V
CC
= 5 V
T
A
= 25°C
CC
V
CC
= 4.5 V
T
= 25°C
A
T
A
= – 55°C
T
A
= 125°C
Disabled
Low
Disabled
Low
0
1
2
3
4
0
1
2
3
4
V – Input Voltage (Output Control) – V
I
V – Input Voltage (Output Control) – V
I
Figure 8
Figure 9
OUTPUT VOLTAGE
vs
HIGH-LEVEL OUTPUT VOLTAGE
vs
FREE-AIR TEMPERATURE
OUTPUT CURRENT
5
4
V
CC
= 4.5 V
T
A
= 25°C
3.6
3.2
2.8
2.4
2
V
= 5.5 V
CC
4
3
2
1
0
V
(I = –10 mA)
OH OH
V
CC
= 5 V
V (I = – 40 mA)
OH OH
1.6
1.2
0.8
0.4
0
V
= 4.5 V
CC
V
(I
= 40 mA)
25
OL OL
–75
– 25
0
50
75
100 125
0
– 20
–100
–120
–50
–40
–60
–80
T
A
– Free-Air Temperature – °C
I
– Output Current – mA
OH
Figure 10
Figure 11
†
Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55113 circuits
only. These parameters were measured with the active pullup connected to the sink output.
9
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
†
TYPICAL CHARACTERISTICS
SUPPLY CURRENT
(BOTH DRIVERS)
vs
LOW-LEVEL OUTPUT VOLTAGE
vs
OUTPUT CURRENT
SUPPLY VOLTAGE
0.6
0.5
0.4
0.3
0.2
0.1
0
80
70
60
50
No Load
T
A
= 25°C
T
A
= 25°C
V
= 4.5 V
CC
Inputs Grounded
Inputs Open
40
30
V
CC
= 5.5 V
20
10
0
0
20
40
50
80
100
120
0
1
2
3
4
5
6
7
8
I
– Output Current – mA
V
CC
– Supply Voltage – V
OL
Figure 12
Figure 13
SUPPLY CURRENT
(BOTH DRIVERS)
vs
SUPPLY CURRENT
(BOTH DRIVERS)
vs
SUPPLY VOLTAGE
OUTPUT CURRENT
56
54
52
50
48
46
44
42
100
90
V
= 5 V
CC
V
= 5 V
CC
R
C
= ∞
= 30 pF
L
L
Inputs Grounded
No Load
80
70
Inputs: 3-V Square Wave
T
A
= 25°C
60
50
40
30
20
10
0
40
38
36
0.1
0.4
1
4
10
40 100
– 75 – 50 – 25
0
25
50
75
100 125
f – Frequency – MHz
T
A
– Free-Air Temperature – °C
Figure 14
Figure 15
†
Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55113 circuits
only. These parameters were measured with the active pullup connected to the sink output.
10
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
†
TYPICAL CHARACTERISTICS
PROPAGATION DELAY TIMES
FROM DATA INPUTS
vs
OUTPUT ENABLE AND DISABLE TIMES
vs
FREE-AIR TEMPERATURE
FREE-AIR TEMPERATURE
20
18
16
14
12
10
8
30
25
V
C
= 5 V
CC
= 30 pF
See Figure 1
V
= 5 V
CC
See Figures 2 and 3
L
t
PLH
t
PLZ
20
15
t
PHL
t
PZL
t
PHZ
10
5
6
t
PZH
4
2
0
0
– 75 – 50 – 25
0
25
50
75
100 125
– 75 – 50 – 25
0
25
50
75
100 125
T
A
– Free-Air Temperature – °C
T
A
– Free-Air Temperature – °C
Figure 16
Figure 17
†
Data for temperatures below 0°C and above 70°C and for supply voltages below 4.75 V and above 5.25 V are applicable to SN55113 circuits
only. These parameters were measured with the active pullup connected to the sink output.
APPLICATION INFORMATION
Location 5
Location 3
‡
‡
R
T
R
T
Location 6
Location 1
Location 2
Location 4
Twisted
Pair
SN75113 Driver
SN75115 Receiver
= Z . A capacitor may be connected in series with R to reduce power dissipation.
‡
R
T
O
T
Figure 18. Basic Party-Line or Data-Bus Differential Data Transmission
11
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
相关型号: