SSRK-240D30 [TE]
10-30A DIN Mount Solid State Relay With Paired SCR Output, Integral Heatsink;型号: | SSRK-240D30 |
厂家: | TE CONNECTIVITY |
描述: | 10-30A DIN Mount Solid State Relay With Paired SCR Output, Integral Heatsink 输出元件 光电 |
文件: | 总2页 (文件大小:205K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Potter & Brumfield
Solid State Relay
SSRK Series
10-30A DIN Mount Solid State Relay
With Paired SCR Output, Integral Heatsink
File E29244
Users should thoroughly review the technical data before selecting a
product part number. It is recommended that users also seek out the
pertinent approvals files of the agencies/laboratories and review them to
ensure the product meets the requirements for a given application.
Engineering Data
Features
Form: 1 Form A (SPST-NO).
• Narrow (22.5mm), DIN mount design with integral heatsink.
• Choice of 10, 20 or 30A rms inverse-parallel connected SCR output.
• 24-240VAC and 48-660VAC output types.
• 3 - 32VDC, 4 - 32VDC or 90 - 280Vrms input control.
• 4000V rms optical isolation.
• Green LED input status indicator.
• Finger-safe (IP20) screw clamp terminals for load and control.
• Ground terminal.
Duty: Continuous.
Isolation: 4000V rms input-to-output-to-ground.
9
Insulation Resistance: 10 Ohms, minimum, at 500VDC.
Capacitance: 8.0 pf maximum (input to output).
Temperature Range:
Storage: –30°C to +100°C
Operating: –30°C to + 80°C
Case and Mounting: Refer to outline dimension drawing.
Termination:
Load & Control: Finger safe (IP20) screw clamps accepting
wire size up to #10 AWG (3 mm).
Ground: #10 screw with 5/16 in. hex/slottted head.
Installation Spacing: Minimum 0.8 in (20 mm) space between units.
Approximate Weight: 9.87 oz. (280g).
Ordering Information
SSRK –600 A
Typical Part Number
30
>
1. Basic Series: SSRK = Slim Solid State Relay with Integral Heatsink for DIN Rail Mounting
2. Line Voltage: 240 = 24 - 240 VAC
600 = 48 - 660 VAC
3. Input Type & Voltage: A = 90 - 280 VAC
D = 3 - 32VDC for 240V / 4 - 32VDC for 600V
4. Maximum Switching Rating / Output: 10 = 10.0A rms
20 = 20.0A rms
30 = 30.0A rms
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
SSRK-240A20
SSRK-240D20
SSRK-240A30
SSRK-240D30
SSRK-600A30
SSRK-600D30
Input Specifications
Parameter
DC Control Units
600V
Conditions
AC Control Units
240 V
Control Voltage Range VIN
@25°C
@25°C
@25°C
@25°C
90 - 280 Vrms
90 Vrms
3 -32 VDC
3 VDC
4 -32 VDC
4 VDC
Must Operate Voltage VIN(OP) (Min.)
Must release Voltage VIN(REL) (Min.)
Input Current Range(Typ.)
10 Vrms
1 VDC
1 VDC
7.5mA @ 120 Vrms, 16mA @ 240 Vrms
18mA @ 5Vdc
9.5 - 30 mA
1
02-2018, Rev. 0218
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Potter & Brumfield
Solid State Relay
SSRK Series (Continued)
SCR Output Modules
Output Specifications (@ +25˚C unless otherwise specified)
Parameter
Conditions
Nom. Line Voltage
Units
10A Rated Units 20A Rated Units 30A Rated Units
240 V model
600 V model
V rms
V rms
V peak
V peak
A rms
A peak
A peak
mA rms
V peak
V peak
V/μs
24 - 240
48 - 660
600
24 - 240
48 - 660
600
24 - 240
48 - 660
600
Load Voltage VL
f = 47 - 63Hz
240 V model
Repetitive Blocking Voltage (Min.)
Load Current IL*
600 V model
1200
0.15 - 10
83
1200
0.15 - 20
300
1200
0.15 - 30
800
240 V & 600 V model
240 V model
Single Cycle Surge Current (Min.)
600 V model
300
300
800
Leakage Current (Off-State) (Max.) f = 60Hz. - VL = 600Vrms 240 V & 600 V model
240 V model
5
5
5
1.8
1.8
1.8
On-State Voltage Drop (Max.)
IL=Max.
VL=Max.
f = 60Hz.
600 V model
240 V model
1.6
1.6
1.8
200
300
500
Static dv / dt (Off-State) (Min.)
600 V model
V/μs
300
300
500
Turn-On Time (Max.)
Turn-Off Time (Max.)
240 V & 600 V model
240 V & 600 V model
240 V model
ms
10 for DC Input Models, 40 for AC Input Models
10 for DC Input Models, 80 for AC Input Models
ms
A²s
41
510
0.5
510
510
0.5
3745
3745
0.5
I²t Rating (Max.)
t = 8.3 ms
IL=Min.
600 V model
A²s
Load Power Factor Rating (Min.)
240 V & 600 V model
* See Derating curve
Electrical Characteristics (Thermal Derating Curves)
Outline Dimensions
2
02-2018, Rev. 0218
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
相关型号:
©2020 ICPDF网 联系我们和版权申明