FX29J3-040B-0025-L 概述
Compact Compression Load Cell
FX29J3-040B-0025-L 数据手册
通过下载FX29J3-040B-0025-L数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载te.com
FX29
Compact Compression Load Cell
Versatile Miniature Force Sensor
mV, Amplified, and Digital Outputs
Low Power Consumption
Rugged Microfused Sensing Element
Stainless Steel Enclosure
Several Load Ranges
TE Connectivity’s (TE) FX29 is a compact compression load cell
that offers exceptional price-to-performance in a robust sensor
package. Optimized for embedded force sensing applications from
disposable medical devices to durable appliances and exercise
equipment. The FX29 allows design flexibility with mV, amplified,
and digital output options.
Features
• Compact Design
The FX29 incorporates the high reliability Microfused technology
and is offered in ranges from 10lbf to 200lbf (50N to 1000N).
Microfused technology provides excellent span and zero stability,
outstanding cycle life, superior resolution, high over-range
capabilities, and an unamplified span sensitivity of 20mV/V.
• mV or Amplified Analog Outputs
• Optional I2C Digital Interface
• High Over Range Capability
The FX29 utilizes a two-piece construction of stainless steel
materials. The combination of a metal injection molded flexure and
micro miniaturized MEMS strain gauges allows flexibility of force
range options for a lower cost sensor. These improvements over
previous load cell designs give the FX29 more precise
dimensional control and better performance.
Applications
• Medical Infusion Pumps
• Analog & Digital Scales
• Fitness & Exercise Equipment
• Payload Weighing
• Power Tools
• Robotics
• Surgical & Dental Tools
• Battery Powered Devices
• Manufacturing Equipment
›
CLICK HERE
CONNECT WITH A SPECIALIST
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 1
FX29
Compact Compression Load Cell
Absolute Maximum Ratings (Analog) (1)
Parameter
Supply voltage
Symbol
Min
Typ
Max
Units
Notes/Conditions
6.0
V
Analog mV Output
Vdd
5.25
+85
2.5X
4.0
V
°C
Analog 0.5-4.5V Output
Storage temperature
Compressive load
ESD
TS
-40
Lmax
Rated
kV
-4.0
Human Body Model
(1) Maximum limits the device will withstand without damage
Standard Load Ranges
Pounds-Force (lbf)
Newtons (N)
10
50
25
50
125
250
100
200
500
1000
Electrical Specifications (Analog)
(Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied)
Parameter
Symbol
Min
Typ
Max
Units
Notes/Conditions
1.00
6.0
V
mV Output only
Supply voltage (Vsupply
)
Vdd
4.75
5.25
3
V
mA
0.5-4.5V Output only
0.5-4.5V Output only
mV Output only
mV Output only
10% to 90%
Operating current
Input resistance
Output resistance
Rise time
Idd
Rin
Rout
Tr
2.4
3.0
2.2
3.6
2.64
2.0
kΩ
1.76
kΩ
ms
Maximum output current
Output short circuit duration
Insulation resistance
Bandwidth
Io
2.2
50
mA
0.5-4.5V Output only
0.5-4.5V Output only
@250VDC
Ts
∞
seconds
MΩ
1.0
kHz
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 2
FX29
Compact Compression Load Cell
Operating Specifications (Analog)
(Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied)
Parameter
Zero offset1
Symbol
Min
Typ
Max
Units
Notes/Conditions
-15
15
mV/V
mV Output only
300
16
500
20
700
24
mV
mV/V
0.5-4.5V Output only
mV Output only
0.5-4.5V Output only
BFSL
Full scale span1
3800
-1
4000
4200
1
mV
Non-linearity
%Span
%Span
%Span
%Span
%Span/°C
%Span/°C
Hysteresis
-0.8
-0.8
-0.8
-0.05
-0.05
1E+6
0.8
Zero repeatability
Span repeatability
Thermal shift for zero
Thermal shift for span
Cycle life
0.8
0.8
0.05
0.05
Reference to 25°C, over
compensated temperature
0 to full scale cycles
Deflection at rated load
Weight
0.03
mm
6.0
grams
Without ribbon cable
(1) Span and zero offset are ratiometric to power supply voltage
Environmental Specifications (Analog)
(Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied)
Parameter
Symbol
Min
Typ
Max
Units
Notes/Conditions
Compensated temperature
range
To
0
50
°C
0.5-4.5V Output only
Storage temperature
Ambient humidity
Ts
IP
-40
0
85
85
°C
%RH
Non-condensing
mV Output only
IEC61000-4-2 (8kVair/4kVcontact
IEC61000-4-3 (3V/m)
EN55032 Class A
)
EMI/RFI/ESD protection
Ingress protection
Media compatibility
43
External exposed surfaces: 17-4 and 304
stainless steel
Excluding cable &
connector
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 3
FX29
Compact Compression Load Cell
Schematic Diagram – mV output (Analog)
Block Diagram – 0.5 to 4.5V output (Analog)
Vdd
ANALOG
OUTPUT
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 4
FX29
Compact Compression Load Cell
Absolute Maximum Ratings (Digital) (1)
Parameter
Supply voltage
Symbol
Min
Typ
Max
Units
Notes/Conditions
5.50
V
Storage temperature
Compressive load
ESD
TS
-40
+85
2.5X
4.0
°C
Rated
kV
Lmax
-4.0
Human Body Model
(1) Maximum limits the device will withstand without damage
Standard Load Ranges
Pounds-Force (lbf)
Newtons (N)
10
50
25
50
125
250
100
200
500
1000
Electrical Specifications (Digital)
(Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied)
Parameter
Symbol
Min
Typ
Max
Units
Notes/Conditions
Supply voltage (Vsupply
)
Vdd
2.7
5.5
V
Operating current
Sleep mode current
Insulation resistance
Idd
3
5
mA
µA
Islp
0.5
50
MΩ
@250VDC
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 5
FX29
Compact Compression Load Cell
Force Operating Specifications (Digital)
(Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied)
Parameter
Zero offset
Symbol
Min
Typ
Max
Units
Notes/Conditions
300
1000
1700
Counts
Base10
Full scale span
Non-linearity
14300
-1
15000
15700
1
Counts
%Span
Base10
BFSL
Hysteresis
-0.8
0.8
%Span
Zero repeatability
Span repeatability
Thermal shift for zero
Thermal shift for span
Cycle life
-0.8
0.8
%Span
-0.8
0.8
%Span
-0.05
-0.05
1E+6
0.05
0.05
%Span/°C
%Span/°C
Reference to 25°C, over
compensated temperature
0 to full scale cycles
A/D resolution
14
Bits
mS
3
4MHz, non-sleep mode
4MHz, sleep mode
Response time
8.4
mS
Deflection at rated load
Weight
0.03
mm
6.0
grams
Without ribbon cable
Environmental Specifications (Digital)
(Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied)
Parameter
Symbol
Min
Typ
Max
Units
Notes/Conditions
Compensated temperature
range
To
0
50
°C
Storage temperature
Ambient humidity
Ingress protection
Ts
-40
0
85
85
°C
%RH
Non-condensing
IP
43
External exposed surfaces: 17-4 and 304
stainless steel
Excluding cable &
connector
Media compatibility
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 6
FX29
Compact Compression Load Cell
Block Diagram – I2C Digital Output (Digital)
SDA
SCL
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 7
FX29
Compact Compression Load Cell
Force Output Graph (Digital)
ꢒ4ꢓꢓꢓ
ꢄ
ꢑ
ꢀꢁꢂꢃꢁꢂ ꢅꢆꢇꢈꢉꢊꢋ ꢇꢌꢍꢎꢏꢐ =
∗ ꢛꢀꢗꢜꢚ + ꢒꢓꢓꢓ
ꢔꢀꢕꢖ ꢗꢕꢘꢙꢚ
Force Sensor Output
%Output
0%
Counts (decimal)
1000
Counts (hex)
0x3E8
5%
1700
0x6A4
10%
2400
0x960
50%
8000
0x1F40
0x3520
0x37DC
0x3A98
90%
13600
95%
100%
14300
15000
I2C Typical Circuit
Note: only one pair of pull up resistors are needed for multiple sensing devices.
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 8
FX29
Compact Compression Load Cell
I2C Interface
Parameter
Symbol
Min
Typ
Max
Units
Notes/Conditions
SCLK clock frequency
FSCL
100
400
kHz
Start condition hold time relative to
SCL edge
tHOSTA
0.1
µS
Minimum SCL clock low width1
tLOW
tHIGH
0.6
0.6
µS
µS
Minimum SCL clock high width1
Start condition startup time relative to
SCL edge
tSUSTA
tHDDAT
0.1
0
µS
µS
Data hold time on SDA relative to SCL
edge
Data setup time on SDA relative to
SCL edge
tSUDAT
tSUSTO
tBUS
0.1
0.1
2
µS
µS
µS
Stop condition setup time on SCL
Bus free time between stop and start
condition
I2C Interface Timing Diagram
Digital Input and Output Parameters
(Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied)
Parameter
Input high voltage
Symbol
Min
Typ
Max
Units
Notes/Conditions
VIH
0.8
1.0
x Vdd
Input low voltage
VIL
0.0V
0.2
x Vdd
x Vdd
pF
Output low level
Load capacitance @ SDA
Input capacitance (each pin)
200
10
@400 kHz
pF
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 9
FX29
Compact Compression Load Cell
I2C Measurement Packet Read Sequence
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 10
FX29
Compact Compression Load Cell
General Working Mode
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 11
FX29
Compact Compression Load Cell
Outline Drawing and Connections
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 12
FX29
Compact Compression Load Cell
Mounting Recommendation
The sensor can be put into a simple slot fixture for load testing. The load should be applied to the spherical face
of center boss. Recommended to stick the sensor with double face 3M adhesive or glue. Some feature to clamp
the sensor from top to down can be optional.
See below for reference:
NOTE: Clamping force may shift the zero reading slightly. Re-zero if needed.
Below table shown the Zero change difference when loaded 5 Lbf from the top. (For reference only)
Load Range
10L
25L
50L
100L
Changing for reference
0.5%FS
0.4%FS
0.35%FS
0.25%FS
Dimension for reference:
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 13
FX29
Compact Compression Load Cell
Ordering Information
FX29 X X – XXX X – XXXX – X
Output Signal
Measurement Units
Code
Output
20 mV/V*
0.5 – 4.5V*
I2C
(None Sleep)
I2C (Sleep)*
Output Type
L
N
Pounds-force (lbf)*
Newtons
2
3
J
mV
Amplified
Digital
Load Range
LBF
Newtons
0050
K
Digital
0010*
I2C Address
0025*
0125
0050*
0250
Code
Device Address (hex)
0100*
0200*
(MACHINING)
0500
1000
X
0
1
2
3
4
Analog Output*
0x28*
0x36
0x46
0x48
0x51
Cable & Connector
Code
A
B
Cable and Connector
4-wire ribbon cable without connector
4-wire ribbon cable with connector*
Cable Length
Code
040
Length
40 mm*
100 mm*
Note: For digital output, ensure custom cable
length does not exceed 1 meter.
100
XXX
Custom Length
*Sensor features shown in bold are typically stocked by our distribution partners, or available with short lead times from the
factory depending on availability. Contact customer service for details.
Caution:
For the digital sensor. User can change the address along with the guide as below link.
Please notice, any data changed by users means users give up the quality assurance terms. TE will not guarantee the
sensor performance any more.
https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7FDIGITAL_MODEL
S_CHANGING_I2C_SLAVE_ADDRES%7FA1%7Fpdf%7FEnglish%7FENG_SS_DIGITAL_MODELS_CHANGING_I2C_SLAVE_ADDRES_A1
.pdf%7FCAT-PTT0015
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
Page 14
FX29
Compact Compression Load Cell
REVISION HISTORY
Revision Number
Change Description
Date
Approval
MH
A3
A4
A5
Minor corrections ;
06/24/2019
07/29/2020
10/27/2020
Correct pin numerical to be same as connector
Mounting Recommendation and Caution added;
MH
MH
›
CLICK HERE
CONNECT WITH A SPECIALIST
NORTH AMERICA
Tel +1 800 522 6752
EUROPE
Tel +31 73 624 6999
ASIA
Tel +86 0400 820 6015
te.com/sensors
Microfused, Measurement Specialties (MEAS), TE Connectivity, TE, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products
and/or company names referred to herein might be trademarks of their respective owners
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE
Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as
set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or
consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine
the suitability of each such product for the specific application.
© 2020 TE Connectivity Corporation. All Rights Reserved.
TE CONNECTIVITY SENSORS /// FX29
DOC CONTROL NUMBER 05142019
10/2020
FX29J3-040B-0025-L 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
FX29J3-040B-0025-N | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-040B-0050-L | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-040B-0050-N | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-040B-0100-L | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-040B-0100-N | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-040B-0200-L | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-040B-0200-N | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-100A-0010-L | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-100A-0010-N | TE | Compact Compression Load Cell | 获取价格 | |
FX29J3-100A-0025-L | TE | Compact Compression Load Cell | 获取价格 |
FX29J3-040B-0025-L 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6