03EQ3 [TE]
Highest Performance RFI Filters for Switching Power Supply Emissions down to 10 kHz; 最高性能的RFI滤波器,用于开关电源排放量降低至10 kHz型号: | 03EQ3 |
厂家: | TE CONNECTIVITY |
描述: | Highest Performance RFI Filters for Switching Power Supply Emissions down to 10 kHz |
文件: | 总2页 (文件大小:101K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CORCOM Product Guide
Highest Performance RFI Filters for Switching Power Supply
Emissions down to 10 kHz
Q Series
Q8-6A
UL Recognized
CSA Certified
VDE Approved
Q1
Q3
Q Series
Specifications
Maximum leakage current,each line-to-ground
This series of RFI power line filters has been developed
specifically for switching power supplies and is designed to
be all the power line filtering needed to control conducted
emissions all the way down to 10kHz. High attenuation is
provided for both common mode and differential mode
interference throughout the frequency range with no
degradation of performance due to the large peak currents
drawn by switching power supplies.
VQ Models EQ Models
.73 mA
—
1.27 mA
—
@ 120 VAC 60 Hz (3A, 20A):
@ 120 VAC 60 Hz (6A):
@ 250 VAC 50 Hz (3A, 20A):
@ 250 VAC 50 Hz (6A):
Hipot rating (one minute):
line-to-ground
.22 mA
.29 mA
.38 mA
.51 mA
2250 VDC
1450 VDC
50/60 Hz
These filters are an ideal choice for applications that must
meet emission limits below 150kHz, as well as the
mandated limits above 150kHz. In most cases they will
bring such equipment into compliance with the B-level
limits of CISPR 22. They are also well suited for bringing
ISM equipment (such as ultrasonic cleaners) into
compliance with the limits of FCC Part 18, from 10kHz to
30MHz.
line-to-line
Operating frequency:
Rated voltage (max.):
250 VAC
Rated current:
3VQ/3EQ
6EQ
20EQ1/20VQ1
3A
6A
20A
The EQ models meet the very low leakage current
requirements VDE portable equipment, and (120 Volt)
UL544 non-patient medical equipment. The VQ models
offer higher common mode performance at the expense of
higher leakage current, but still meet the leakage current
limits of UL, CSA, and VDE non-portable equipment.
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating
Frequency–MHz
.01 .02 .05 .15 .5
1
5
10 30
3VQ
3EQ
6EQ
22 27 37 50 55 55 55 50 55
22 27 36 47 47 43 45 45 45
26 31 20 68 72 72 65 65 65
Electrical Schematics
20EQ1
20VQ1
6
6
10
3
8
39 60 65 65 65 55
17 52 65 70 70 70 70
3EQ & 3VQ Models
Line-to-line in 50 ohm circuit
LINE
LOAD
LOAD
Current
Rating
Frequency–MHz
.01 .02 .05 .15 .5
1
5
10 30
3VQ
3EQ
6EQ
20EQ1
20VQ1
1
1
6
17 42 65 75 75 60 65 65
17 42 65 75 75 65 65 60
10 43 70 75 75 65 55 55
6EQ & 20EQ Models
15 20 20 46 65 70 65 60 60
15 20 20 46 65 70 65 60 60
LINE
Line Cord
Resistor location for reference only.
Line Cord No. GA400: 7 1/2 foot, 3-conductor line cord
to mate with Q8 models.
76
Catalog 1654001
Revised 03-04
Dimensions are in inches and
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
1-508-992-4495
www.cor.com
www.tycoelectronics.com
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Germany:
49-89-6089-0
CORCOM Product Guide
Highest Performance RFI Filters for Switching Power Supply
Emissions down to 10 kHz (Continued)
Q Series
6A-Q8 & Q8M (with metric insert)
Case Styles
No. 6-32 x 1/4 (3)-Q8
No. M-3 x .5 (3)-Q8M
Q1
Tapped insert:
3, 20 Amp Models
Grn/Yel
Brown
C
0.63
16.0
B
Ref
Blue
.313
7.95
Ref
B
D
E
D
C
A
E
A
6 Amp Models
B
Case Dimensions
C
A
B
C
D
E
(max)
Part No.
Typical dimensions:
Terminals: .250 [6.35] (5)
± .015
(max) (max) (max)
Holes: .07 [1.8] Dia.(4)
± .38
Mounting Holes: .188 [4.78] Dia. (2) Slot: .07 x .16 [1.8 x 4.1]
3.85
97.8
2.07
52.6
1.78 2.938
45.2 74.63
3.34
84.8
3VQ1, 3EQ1
3VQ3, 3EQ3
Q3
2.56
65.0
2.07
52.6
1.78 2.938
45.2 74.63
3.34
84.8
3 Amp Models
Blue
Blue
Grn/Yel
Brown
Blue
3VQ8, 3VQ8M 3.07
3EQ8, 3EQ8M 78.0
2.25
57.2
1.78 1.575
45.2 40.01
0.63
16.0
†
Grn/Yel
Brown
B
Brown
4.98
126.5
2.27
57.7
1.80 4.063
4.47
6EQ1
45.7 103.2 113.5
1.80 4.063 4.47
45.7 103.2 113.5
A
D
E
C
3.69
93.7
2.27
57.7
6EQ3
6 Amp Models
5.47
138.9
2.07
52.6
1.78 1.575
45.2 40.01
2.70
68.0
6EQ8, 6EQ8M
Blue
B
Brown
Grn/Yel
6.66
168.1
2.07
52.6
2.28 5.625
57.9 142.9 153.2
6.03
20EQ1,20VQ1
†
C
† ±.02 [±.5]
Typical dimensions:
Wire leads: 4.0 [101.6] Min.
Mounting Holes: .188 [4.78] Dia. (2)
3A-Q8 & 8Q8M (with metric insert)
Part Numbers
No. 6-32 x 1/4 (2)-Q8
Tapped insert:
No. M-3 x .5 (2)-Q8M
03EQ1
03EQ3
03EQ8
03EQ8M
06EQ1
06EQ3
06EQ8
06EQ8M
20EQ1
03VQ1
03VQ3
03VQ8
03VQ8M
20VQ1
Brown
Grn/Yel
D
B
Blue
A
E
C
.235
5.96
.157
3.98
R
Dia. (2)
Line Cord:
GA400
.910
23.11
1.295
32.89
1.575
40.01
Typical dimensions:
Wire leads: 6.0 [152.4] Min.
Panel Cutout (back mount)
Tolerance ±.005 [0.13]
77
Catalog 1654001
Revised 03-04
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
1-508-992-4495
www.cor.com