TMXS124P [TEMEX]
SAW Filter, 1 Function(s), 465MHz,;型号: | TMXS124P |
厂家: | TEMEX |
描述: | SAW Filter, 1 Function(s), 465MHz, |
文件: | 总5页 (文件大小:514K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SAW Filters
TMX S124P
SAW Bandpass Filter - CDMA450 - Rx RF
Preliminary Specification (Rev-3)
Technical overview ..............................................................P01
Matching Network Configuration ..........................................P01
Typical Response (Measurement) .......................................P03
Package Drawing..................................................................P04
TMX S124P
SAW Bandpass Filter – CDMA450 – Rx RF
Specification (Rev 3)
June 8th, 2006
Operating temperature range : [-10°C; +85°C]
Electrical Parameters
Unit
Minimum
Typical (1)
Maximum
Source Impedance (single ended)
Load Impedance (single ended)
-
-
-
50(2)
50(2)
465
-
-
-
Ω
Ω
Center Frequency fo
Absolute Attenuation
300 kHz to 452.5 MHz
452.5 MHz to 457.5 MHz
MHz
dB
dB
48
35
55
39
-
-
452.5 MHz to 457.5 MHz within
[ + 15°C ; + 40°C ]
dB
40
44
-
485 MHz to 507.5 MHz
507.5 MHz to 1200 MHz
1200 MHz to 1700 MHz
1700 MHz to 2000 MHz
dB
dB
dB
dB
40
40
30
15
53
45
40
25
-
-
-
-
Maximum Insertion Loss in 462.5 MHz – 467.5
MHz
dB
-
2.6
3.8
Input VSWR in 462.5 MHz – 467.5 MHz @ 21°C
Output VSWR in 462.5 MHz – 467.5 MHz @ 21°C
Input Power in 462.5 MHz-467.5 MHz (3)
Temperature Coefficient
Package type & size
-
-
-
-
-
-
1.5 : 1
1.5 : 1
-
2.1 : 1
2.1 : 1
28
dBm
ppm/°C
-32
-
Length x Width
mm²
mm
-
-
3.8 x 3.8
1.1
-
Height
1.375
Pin Out
Input
Output
2
5
Case Ground
To Be Grounded
1,3,4,6
1,3,4,6
Notes :
(1) Typical values are nominal performances at room temperature
(2) No external matching circuit is required
(3) Minimum life time at 50°c superior to 50 000 hours.
50 Ω / 50 Ω CONFIGURATION
Input
50 Ω
Single
Output
50 Ω
Single
GND
1
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.
TMX S124P
SAW Bandpass Filter – CDMA450 – Rx RF
Specification (Rev 3)
June 8th, 2006
Operating Temperature range : [-30°C ; +80°C]
Electrical Parameters
Unit
Minimum
Typical (1)
Maximum
Source Impedance (single ended)
Load Impedance (single ended)
-
-
-
50(2)
50(2)
465
-
-
-
Ω
Ω
Center Frequency fo
Absolute Attenuation
300 kHz to 452.5 MHz
452.5 MHz to 457.5 MHz
MHz
dB
dB
48
37
55
39
-
-
452.5 MHz to 457.5 MHz within
[ + 15°C ; + 40°C ]
dB
40
44
-
485 MHz to 507.5 MHz
507.5 MHz to 1200 MHz
1200 MHz to 1700 MHz
1700 MHz to 2000 MHz
dB
dB
dB
dB
40
40
30
15
53
45
40
25
-
-
-
-
Maximum Insertion Loss in 462.5 MHz – 467.5
MHz
dB
-
2.6
4.8
Input VSWR in 462.5 MHz – 467.5 MHz @ 21°C
Output VSWR in 462.5 MHz – 467.5 MHz @ 21°C
Input Power in 462.5 MHz-467.5 MHz (3)
Temperature Coefficient
Package type & size
-
-
-
-
-
-
1.5 : 1
1.5 : 1
-
2.1 : 1
2.1 : 1
28
dBm
ppm/°C
-32
-
Length x Width
mm²
mm
-
-
3.8 x 3.8
1.1
-
Height
1.375
Pin Out
Input
Output
2
5
Case Ground
To Be Grounded
1,3,4,6
1,3,4,6
Notes :
(1) Typical values are nominal performances at room temperature
(2) No external matching circuit is required
(3) Minimum life time at 50°c superior to 50 000 hours.
2
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.
TMX S124P
SAW Bandpass Filter – CDMA450 – Rx RF
Specification (Rev 3)
June 8th, 2006
TYPICAL S21 RESPONSE
The template indicated is linked to the specification over [-10; +85°C] temperature range.
3
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.
TMX S124P
SAW Bandpass Filter – CDMA450 – Rx RF
Specification (Rev 3)
June 8th, 2006
P
ACKAGE DRAWING
S124
4
TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum performance and cost.
相关型号:
©2020 ICPDF网 联系我们和版权申明