DG34-1011-16-5120 [TELEDYNE]
pcb / industrial power relay;型号: | DG34-1011-16-5120 |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | pcb / industrial power relay |
文件: | 总3页 (文件大小:350K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DG34
pcb / industrial power relay
• Up to 40A /240VAC continuous rating
• 110VDC maximum switching voltage
• Industry standard style
• Cost effective
• RoHS Compliant
E325835
Contacts
Contact number & arrangement
Contact material
SPST-NO (1 Normally Open); SPDT ( 1 Changeover)
AgSnO2 (standard), AgCdO
Max. switching voltage
AgSnO2 : 250VAC / 110VDC
AgCdO : 250VAC / 28VDC
Min. switching current / voltage
Max. continuous current
500mA/12VDC (AgCdO, AgSnO2)
AgSnO2 : SPST-NO: 40A / SPDT: 40A (NO), 30A (NC)
AgCdO : SPST-NO: 30A / SPDT: 30A (NO), 20A (NC)
Max. switching current
Max. switching power
Initial resistance
AgSnO2 : SPST-NO: 40A / SPDT: 40A (NO), 30A (NC)
AgSnO2 : 7200VA / 1100W : AgCdO: 6000VA / 560W
≤ 100mΩ, max. at 0.1A/6VDC
Coil
Rated voltage
3...110VDC; 12...220VAC
DC ≥ 0.1Un : AC ≥ 0.3Un
See coil tables 1 & 2
Must release voltage
Operating range of supply voltage
Rated power consumption
Insulation
0.93W (DC), 1.2VA (AC)
Insulation resistance
Dielectric strength
>100MΩ at 500VDC, 50%RH
coil to contact 4000Vrms, 1min (50Hz)
between open contacts 1500Vrms, 1min (50Hz)
creepage / clearance - coil to contact ≥ 3mm
General Data
Operating time (typical)
Release time (typical)
Electrical Life
ms 15
ms 10
ops 1 x 105 (1s on / 1s off)
ops 1 x 106 (300 ops per minute)
L x W x H various - see dimensional drawings. (Figs 1 & 4)
≤ 36g
Mechanical life
Dimensions
Weight
Ambient temperature
storage -40 to 155°C
operating -40 to 125°C
Shock resistance
Drop resistance
Functional: 10g 11mS; Destructive: 100g
1M height drop on to concrete (sealed type only)
10-55Hz: DA 1.5mm
Vibration resistance
Page 1 of 3
Ref: DG34 041515 JHM
www.durakoolrelays.com
Sales Department Tel: (888) 847-6552
Specifications are subject to change without notice. E&OE.
DG34
pcb / industrial power relay
Coil Data
DC Coil
Table 1
Nominal
Operating
Power
Must operate
voltage max.
(VDC)
Must release
voltage min.
(VDC)
Coil Voltage
Code
Nominal Voltage Coil Resistance
Max. allowable
voltage (VDC)
(VDC)
(Ω) ±10%
1003
1005
1006
1009
1012
1018
1024
1048
1110
3
5
10
28
2.25
3.75
0.30
0.50
0.60
0.90
1.20
1.80
2.40
4.80
11.00
6
40
4.50
9
90
6.75
130%
of nominal
12
18
24
48
110
160
360
640
2,560
13,445
0.93W
9.00
13.50
18.00
36.00
82.50
UL Class F Coil insulation standard. (Others to special order)
AC Coil
Nominal
Operating
Power
Must operate
voltage max.
(VAC)
Must release
voltage min.
(VAC)
Coil Voltage
Code
Nominal Voltage Coil Resistance
Max. allowable
voltage (VDC)
(VAC)
(Ω) ±10%
5012
5024
5110
5120
5220
12
24
27
9.00
18.00
82.50
90.00
165.00
3.60
7.20
120
130%
of nominal
110
120
220
2,360
3,040
13,490
1.2VA
33.00
36.00
66.00
UL Class F Coil insulation standard. (Others to special order)
Overall Dimensions - PCB Relays
Fig. 1
PCB Mounting Dimensions
Fig. 2
PCB Open
23.3
4.3 15.6
3.8
14.0
PCB Open + QC
4.3
2 or 3 - 6.4 QC
23.3
25.1
Bottom View (* see note 2 )
PCB Wiring Diagrams
Fig. 3
PCB Covered
20.0
4.3
3
20.2
24.0
27.6
All dimensions in mm
Bottom View
Page 2 of 3
Ref: DG34 041515 JHM
www.durakoolrelays.com
Sales Department Tel: (888) 847-6552
Specifications are subject to change without notice. E&OE.
DG34
pcb / industrial power relay
Overall Dimensions - Chassis Mount Relays
Fig. 4
Wiring Diagrams-Chassis Mount Relays
Fig. 5
*
QC Terminals
6.35 x 0.8 ± 0.03mm for contacts
2.8 x 0.8 ± 0.03mm for coil
All dimensions in mm
Ordering codes
Contact
Material
Contact
arrangement
Cover protec-
tion and
Coil code
Type
mounting
D
G
3
4
-
-
-
Contact Material
10
30
-
-
AgCdO (30A/20A)
AgSnO2 (40A/30A)
(RoHS Compliant)
see Table 1
Contact Arrangement
11
21
-
-
SPDT ( 1 Changeover)
SPST-NO (1 Normally open)
Cover Protection Category
1
3
7
-
-
-
No cover (open frame). Not available with Terminal Option 6
Covered, sealed. IP67
Covered, dust cover
Terminations and mounting
0
5
6
-
-
-
PCB + QC Terminals for contacts (open frame only)
PCB only (no QC Terminals)
Chassis mounting QC terminals for contacts and coil
Notes:
1) All parameters, unless otherwise specified, are measured at an ambient temperature of 23°C.
2) PCB Mounting Holes - the hole is not needed for the SPST-NO version.
“ * ”
3) At an ambient temperature of 85°C, the maximum allowable coil voltage should be reduced to 72%.
4) Electrical life obtained at resistive or inductive load at 30A/15VDC with suitable arc suppression attached and with an operating frequency of 1 op/sec.
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516
Page 3 of 3
Ref: DG34 041515 JHM
www.durakoolrelays.com
Sales Department Tel: (888) 847-6552
Specifications are subject to change without notice. E&OE.
相关型号:
©2020 ICPDF网 联系我们和版权申明