CCR-33S3C [TELEDYNE]
Failsafe SPDT Coaxial Switch;型号: | CCR-33S3C |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | Failsafe SPDT Coaxial Switch 光电二极管 |
文件: | 总8页 (文件大小:595K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
PART NUMBER DESCRIPTION
CCR-33S
CR-33S
Commercial Failsafe SPDT, DC-18GHz
Elite Failsafe SPDT, DC-22GHz
Available with
USB & Ethernet
Control!
The CCR-33S/CR-33S is a broadband, SPDT, electromechanical, coaxial switch designed to switch
a microwave signal from a common input to either of two outputs. The characteristic impedance is 50
Ohms. The small switches incorporate SMA connectors.
The CCR-33S/CR-33S series switch is offered with a failsafe actuator. This design is compatible with the
two most common mounting hole patterns. The CCR-33S/CR-33S series switch is interchangeable with
a variety of switches.
Click here
MMA SERIES
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Form Factor
SPDT,
Commercial Model, CCR-33S
Elite Model, CR-33S
–40°C to 65°C
–55°C to 85°C
break before make
Frequency Range
CCR-33S
CR-33S
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
DC–18 GHz
DC–22 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
Operate Time
50 Ohms
10 ms (max.)
10 ms (max.)
12 15 24 28
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Release Time
Actuation Voltage Available
Actuation Current, max. @ ambient
V
Connector Type
Humidity (Moisture Seal)
Weight
SMA
200 250 120 90 mA
Available
1.65 oz. (46.78g) (max.)
TYPICAL PERFORMANCE CHARACTERISTICS
Frequency
DC–4 GHz
4–8 GHz
8–12 GHz
12–16 GHz
16-20 GHz
20-22 GHz
Insertion Loss, dB,
typcial.
0.1
0.2
0.2
0.3
0.4
0.4
Isolation, dB, typical.
VSWR , typical.
90
90
80
70
65
65
1.1:1
1.1:1
1.1:1
1.2:1
1.2:1
1.2:1
For maximum limits, please see charts on page 3-5
PART NUMBERING SYSTEM
CCR-33
S
1
C
-
T **
Series
Options
Connectors
Actuator Voltage
Actuator Type
Connector
S: SMA Female
Actuator Voltage
Actuator Type
0: Standard Contacts
C: Indicator Contacts
Options
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
N: Narrow Body
**SEE PARTS LIST ON PAGE 8
M: Moisture Seal
S: 9 Pin D-Sub Connector
For other options, contact factory.
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 1
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
SCHEMATICS AND MECHANICAL OUTLINE
Analog
Indicators
TTL
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
H = 1.30 MAX. STD MODEL
H = 1.80 MAX. TTL MODEL
H = 1.30 MAX. STD MODEL
H = 1.80 MAX. TTL MODEL
Optional Narrow Width Body
Standard Width Body
1
6
“-s option” 9-pin d-sub connector (example: ccr-33s10-s)
9 PIN D-SUB PINOUT FOR FAILSAFE SPDT
TRUTH TABLE (with TTL option)
OPTIONS
Logic
Input
Indicator
(if applicable)
RF Path
Pin
No.
1
Indicators &
TTL
Basic
Indicators
TTL
1
IN
IN
A
B
+
-
+
-
to 1
On
Off
to 2
2
0
1
Off
On
C
0
0
3
4
Common
1
Common
1
C
5
6
7
8
9
Vsw
Vsw
A
B
A
B
C
C
CCR-33S/CR-33S Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( DC-4 GHz )
0.0
Insertion Loss ( 4-8 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0
0.5
1
1.5
2
2.5
3
3.5
4
4
4.5
5
5.5
6
6.5
7
7.5
8
Frequency ( GHz )
Frequency ( GHz )
Insertion Loss ( 8-12 GHz )
Insertion Loss ( 12-16 GHz )
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
8
8.5
9
9.5
10
10.5
11
11.5
12
12
12.5
13
13.5
14
14.5
15
15.5
16
Frequency ( GHz )
Frequency ( GHz )
Insertion Loss ( 16-20 GHz )
Insertion Loss ( 20-22 GHz )
0.0
0.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
16
16.5
17
17.5
18
18.5
19
19.5
20
20
20.5
21
21.5
22
Frequency ( GHz )
Frequency ( GHz )
elite model only
typical
maximum test limit
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 3
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( DC-4 GHz )
0.0
Isolation ( 4-8 GHz )
0.0
-20.0
-20.0
-40.0
-40.0
-60.0
-60.0
-80.0
-80.0
-100.0
-120.0
-140.0
-100.0
-120.0
-140.0
0
0.5
1
1.5
2
2.5
3
3.5
4
4
4.5
5
5.5
6
6.5
7
7.5
8
Frequency ( GHz )
Frequency ( GHz )
Isolation ( 8-12 GHz )
Isolation ( 12-16 GHz )
0.0
-20.0
0.0
-20.0
-40.0
-40.0
-60.0
-60.0
-80.0
-80.0
-100.0
-120.0
-140.0
-100.0
-120.0
-140.0
8
8.5
9
9.5
10
10.5
11
11.5
12
12
12.5
13
13.5
14
14.5
15
15.5
16
Frequency ( GHz )
Frequency ( GHz )
Isolation ( 16-20 GHz )
Isolation ( 20-22 GHz )
0.0
-20.0
0.0
-20.0
-40.0
-40.0
-60.0
-60.0
-80.0
-80.0
-100.0
-120.0
-140.0
-100.0
-120.0
-140.0
16
16.5
17
17.5
18
18.5
19
19.5
20
20
20.5
21
21.5
22
Frequency ( GHz )
Frequency ( GHz )
elite model only
typical
maximum test limit
CCR-33S/CR-33S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( DC-4 GHz )
VSWR ( 4-8 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0
0.5
1
1.5
2
2.5
3
3.5
4
4
4.5
5
5.5
6
6.5
7
7.5
8
Frequency ( GHz )
Frequency ( GHz )
VSWR ( 8-12 GHz )
VSWR ( 12-16 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
8
8.5
9
9.5
10
10.5
11
11.5
12
12
12.5
13
13.5
14
14.5
15
15.5
16
Frequency ( GHz )
Frequency ( GHz )
VSWR ( 16-20 GHz )
VSWR ( 20-22 GHz )
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
16
16.5
17
17.5
18
18.5
19
19.5
20
20
20.5
21
21.5
22
Frequency ( GHz )
Frequency ( GHz )
elite model only
typical
maximum test limit
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 5
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
1000
800
600
400
300
200
100
80
60
40
30
20
10
.1
.2 .3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCR-33S/CR-33S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
GLOSSARY
Actuator
TTL Switch Driver Option
An actuator is the electromechanical mechanism that As a special option, switch drivers can be provided for both
transfers the RF contacts from one position to another upon failsafe and latching switches, which are compatible with
DC command.
industry-standard low-power Schottky TTL circuits.
Arc Suppression Diode
Performance Parameters vs Frequency
A diode is connected in parallel with the coil. This diode Generally speaking, the RF performance of coaxial switches
limits the “reverse EMF spike” generated when the coil de- is frequency dependent. With increasing frequency, VSWR
energizes to 0.7 volts. The diode cathode is connected to and insertion loss increase while isolation decreases. All
the positive side of the coil and the anode is connected to data sheets specify these three parameters as “worst case”
the negative side.
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Date Code
All switches are marked with either a unique serial number
or a date code. Date codes are in accordance with MIL- Actuator Current vs Temperature
STD-1285 Paragraph 5.2.5 and consist of four digits. The resistance of the actuator coil varies as a function of
The first two digits define the year and the last two digits temperature. There is an inverse relationship between the
define the week of the year (YYWW). Thus, 1032 identifies operating temperature of the switch and the actuator drive
switches that passed through final inspection during the current. For switches operating at 28 VDC, the approximate
32nd week of 2010.
actuator drive current at temperature, T, can be calculated
using the equation:
Failsafe
I
A
A failsafe switch reverts to the default or failsafe position
when actuating voltage is removed. This is realized by a
return spring within the drive mechanism. This type of switch
requires the continuous application of operating voltage to
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
I
=
T
[1 + .00385 (T-20)]
Where:
I
I
=
=
Actuator current at temperature, T
T
Room temperature actuator current –
see data sheet
A
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
T
=
Temperature of interest in °C
circuit. Indicators are usually a set of internally mounted DC Magnetic Sensitivity
contacts linked to the actuator. They can be wired to digital An electro-mechanical switch can be sensitive to ferrous
input lines, status lights, or interlocks. Unless otherwise materials and external magnetic fields. Neighboring ferrous
specified, the maximum indicator contact rating is 30 Vdc, materials should be permitted no closer than 0.5 inches and
50 mA, or 1.5 Watts into a resistive load.
adjacent external magnetic fields should be limited to a flux
density of less than 5 Gauss.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
SPECIAL FEATURE
SPDT Switch
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
A single-pole double-throw, bi-directional switch that can
be used as having one input and two outputs or two inputs
and one output.
Switching Time
Carrier
Frequency 1
Carrier
Frequency 2
PIM 3rd Order
Frequency
PIM 5th
Order Fre-
quency
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
870 MHz
SPDT
893 MHz
847 MHz
824 MHz
3rd Order
Intermodulation
5th Order
Intermodulation
–91 dBm
–110 dBm
–134 dBc
–153 dBc
© 2015 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCR-33S/CR-33S Page 7
CCR-33S\CR-33S\092015\Q3
Series CCR-33S/CR-33S
Miniature DC–18 GHz/DC-22 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
FAILSAFE CCR-33S/CR-33S PART NUMBER LIST
part no.
part no.
part no.
1
CCR-33SXC
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
CCR-33SX0-TMS
CCR-33SX0-TN
CCR-33SX0-TNM
CCR-33SX0-TNMS
CCR-33SX0-TNS
CCR-33SX0-TS
CR-33SXC
85
86
87
88
89
90
91
92
93
94
95
96
CR-33SX0-NM
CR-33SX0-NMS
CR-33SX0-NS
CR-33SX0-S
2
CCR-33SXC-D
CCR-33SXC-DM
CCR-33SXC-DMS
CCR-33SXC-DN
CCR-33SXC-DNM
CCR-33SXC-DNMS
CCR-33SXC-DNS
CCR-33SXC-DS
CCR-33SXC-M
CCR-33SXC-MS
CCR-33SXC-N
CCR-33SXC-NM
CCR-33SXC-NMS
CCR-33SXC-NS
CCR-33SXC-S
CCR-33SXC-T
3
4
5
CR-33SX0-T
6
CR-33SX0-TM
CR-33SX0-TMS
CR-33SX0-TN
CR-33SX0-TNM
CR-33SX0-TNMS
CR-33SX0-TNS
CR-33SX0-TS
7
8
CR-33SXC-D
9
CR-33SXC-DM
CR-33SXC-DMS
CR-33SXC-DN
CR-33SXC-DNM
CR-33SXC-DNMS
CR-33SXC-DNS
CR-33SXC-DS
CR-33SXC-M
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
CR-33SXC-MS
CR-33SXC-N
CCR-33SXC-TM
CCR-33SXC-TMS
CCR-33SXC-TN
CCR-33SXC-TNM
CCR-33SXC-TNMS
CCR-33SXC-TNS
CCR-33SXC-TS
CCR-33SX0
CR-33SXC-NM
CR-33SXC-NMS
CR-33SXC-NS
CR-33SXC-S
CR-33SXC-T
CR-33SXC-TM
CR-33SXC-TMS
CR-33SXC-TN
CR-33SXC-TNM
CR-33SXC-TNMS
CR-33SXC-TNS
CR-33SXC-TS
CR-33SX0
CCR-33SX0-D
CCR-33SX0-DM
CCR-33SX0-DMS
CCR-33SX0-DN
CCR-33SX0-DNM
CCR-33SX0-DNMS
CCR-33SX0-DNS
CCR-33SX0-DS
CCR-33SX0-M
CCR-33SX0-MS
CCR-33SX0-N
CR-33SX0-D
CR-33SX0-DM
CR-33SX0-DMS
CR-33SX0-DN
CR-33SX0-DNM
CR-33SX0-DNMS
CR-33SX0-DNS
CR-33SX0-DS
CR-33SX0-M
CCR-33SX0-NM
CCR-33SX0-NMS
CCR-33SX0-NS
CCR-33SX0-S
CCR-33SX0-T
CR-33SX0-MS
CR-33SX0-N
CCR-33SX0-TM
*
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCR-33S/CR-33S Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2015 TELEDYNE COAX SWITCHES
CCR-33S\CR-33S\092015\Q3