MSO5034B [TEKTRONIX]
Mixed Signal Oscilloscopes;型号: | MSO5034B |
厂家: | TEKTRONIX, INC. |
描述: | Mixed Signal Oscilloscopes |
文件: | 总28页 (文件大小:2182K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Mixed Signal Oscilloscopes
MSO5000B, DPO5000B Series Datasheet
Key analysis features
®
Wave inspector controls provide easy navigation and automated
search of waveform data
Suite of advanced triggers, with standard Visual Trigger and Search
53 automated measurements, selectable filtering, waveform math and
FFT analysis
Waveform histogram, eye diagram, TIE (jitter/timing) measurement and
analysis
User-definable math using MATLAB, Visual Studio and Excel
Optional analysis for memory, advanced jitter, serial data, power and
Wideband RF
Designing with today’s faster data rates and tighter timing margins requires
an oscilloscope with outstanding signal acquisition performance and
analysis capabilities. Tektronix MSO/DPO5000B Series oscilloscopes
provide exceptional signal fidelity, with 2 GHz bandwidth and 10 GS/s
sample rate, along with advanced analysis and math capabilities, on your
Key protocol features
Trigger and decode options for mid-speed (100 Mb/s to 1 Gb/s) buses
Trigger and decode options for low-speed (<10 Mb/s) buses
®
bench and in your lab. Run Windows -based analysis software right on the
Compliance test options for USB2.0, Ethernet, USB power, MOST, and
Automotive Ethernet
oscilloscope. Point and click Visual Triggers enable you to capture complex
signals with ease. MSO models include 16 digital timing channels, and all
models can be equipped to decode common serial protocols, providing a
comprehensive view of your systems.
Mask testing on communication, computing and video standards
Mixed signal design and analysis (MSO Series)
Key performance specifications
16 digital channels (user upgradeable)
2 GHz, 1 GHz, 500 MHz, and 350 MHz bandwidth models
™
MagniVu high-speed acquisition provides 60.6 ps timing resolution on
all digital channels
Up to 10 GS/s real-time sample rate on one or two channels and up to
5 GS/s on all four channels
Automated triggering, decode, and search on parallel buses
Per-channel threshold settings
™
Up to 250 Megapoint record length with MultiView zoom
®
>250,000 wfms/s maximum waveform capture rate with FastAcq
acquisition
™
FastFrame segmented memory acquisition mode with up to
290,000 segments and >310,000 waveforms per second capture rate
Standard 10 MΩ passive voltage probes with less than 4 pF capacitive
loading and 500 MHz or 1 GHz analog bandwidth
>11 bits vertical resolution using HiRes sampling
User-selectable bandwidth limit and DSP filters for lower noise and
better measurement accuracy
www.tek.com/MSO5000
1
Datasheet
See the performance difference
With up to 2 GHz analog bandwidth and sampling rates up to 10 GS/s, the
MSO/DPO5000B series ensures you have the performance you need to
capture waveforms with the best possible signal fidelity and resolution for
seeing small waveform details.
Probing - Up to 1 GHz bandwidth and less than 4 pF capacitive loading provides active
probe performance and superior performance over passive probes included with other
mid-range oscilloscopes.
Fast discovery
Performance - With up to 2 GHz bandwidth and 10 GS/s sample rate capture
USB2.0 480 Mb/s differential signals with true fidelity and 100 ps resolution.
To debug a design problem, first you must know it exists. Every design
engineer spends time looking for problems in their design, a time-
consuming and difficult task without the right debug tools. The MSO/
DPO5000B Series offers the industry's most complete performance to
capture and isolate events, providing fast insight into the real operation of
Accurate high-speed probing
The TPP Series probes, included standard with every MSO/DPO5000B
Series oscilloscope, provide up to 1 GHz of analog bandwidth, and less
than 4 pF of capacitive loading. The extremely low capacitive loading
minimizes adverse effects on your circuits and is more forgiving of longer
ground leads. And with the probe's wide bandwidth, you can see the high
frequency components in your signal, which is critical for high-speed
applications. The TPP Series passive voltage probes offer all the benefits
of general-purpose probes like high dynamic range, flexible connection
options, and robust mechanical design, while providing the performance of
active probes.
®
your device. Tektronix proprietary FastAcq technology delivers a fast
waveform capture - greater than 250,000 waveforms per second - that
enables you to see glitches and other infrequent transients within seconds,
revealing the true nature of device faults. A digital phosphor display with
color intensity grading shows the history of a signal's activity by using color
to identify areas of the signal that occur more frequently, providing a visual
display of just how often anomalies occur across all channels.
Discover – fast waveform capture rate - over 250,000 wfm/s - maximizes the probability
of capturing elusive glitches and other infrequent events.
2 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
High vertical resolution
If the measurement requirement is to capture high-amplitude signals while
seeing smaller signal details, the MSO/DPO5000B provides the acquisition
flexibility needed to capture the signals of interest while removing the
effects of unwanted noise. With HiRes acquisition vertical resolution can be
increased to over 11 bits while reducing signal noise. Signal fidelity can be
further increased by using channel input filters or applying a wide choice of
DSP filters.
Capture - 100 Meg point acquisition with HiRes acquisition - increase vertical resolution
to >11 bits with dual zoom of waveform details.
Segmented memory
For more efficient data capture, partitioning of memory can extend the total
™
time captured. FastFrame Segmented Memory mode enables you to
select up to 290,000 memory segments with a trigger capture rate of over
310,000 triggers per second. Beyond memory flexibility, segments are time
stamped and can be viewed individually or as an overlay and analyzed
using advanced features like protocol decoding. Signals captured with
Capture - HiRes acquisition - increased vertical resolution to >11 bits while removing
noise on a 650 V Pk-Pk signal while seeing the smaller details of less than 1 V Pk-Pk
with or without apply low-pass filtering.
™
FastFrame can also be post-processed using waveform averaging or
envelope mode.
Long record length
With up to a 250 M point record length, you can capture many events of
interest, even thousands of serial packets, in a single acquisition for further
analysis while maintaining high resolution to zoom in on fine signal details.
For complex analysis like Time Interval Error (TIE) measurements the
longer record length ensures you have enough data captured for handling
clock recovery and creating jitter profiles. Unlike other oscilloscopes in its
class, the MSO/DPO5000B provides flexible setup of both record length
and sampling rate to ensure optimum resolution.
www.tek.com/MSO5000
3
Datasheet
Mixed signal design and analysis (MSO
Series)
The MSO5000B Series mixed-signal oscilloscopes provide 16 digital
channels. These channels are tightly integrated into the oscilloscope's user
interface, simplifying operation and making it possible to solve mixed-signal
issues easily. MSO functionality can also be added later as a user upgrade.
Color-coded digital waveform display
The MSO5000B Series has redefined the way you view digital waveforms.
One common problem with other mixed-signal oscilloscopes is determining
if data is a one or a zero when zoomed in far enough that the digital trace
stays flat all the way across the display. To avoid this problem, the
MSO5000B Series has color-coded digital traces, displaying ones in green
and zeros in blue.
With the color-coded digital waveform display, low values are shown in blue and high
values are shown in green, enabling instant understanding of the bus value whether
transitions are visible or not.
The multiple transition detection hardware of the MSO5000B Series will
show you when the system detects more than one transition. This indicates
that more information is available by zooming in or acquiring at faster
sampling rates. In most cases zooming in will reveal a glitch that was not
viewable with the previous settings.
™
MagniVu high-speed acquisition
The main digital acquisition mode on the MSO5000B Series will capture up
to 40 M points at 500 MS/s (2 ns resolution). In addition to the main record,
the MSO5000B provides an ultra-high-resolution record called MagniVu
which acquires 10,000 points at up to 16.5 GS/s (60.6 ps resolution). Both
the main and MagniVu waveforms are acquired on every trigger and either
can be displayed at any time, running or stopped. MagniVu provides
significantly finer timing resolution than comparable mixed-signal
oscilloscopes on the market, instilling confidence when making critical
timing measurements on digital waveforms.
™
FastFrame - User selectable memory segments allow for efficient memory
management with time stamped capture of SPI bus data along with analysis of serial bus
decoding on multiple data packets. Frames 1, 2, and 9 are shown here.
4 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to
make critical timing measurements on your digital waveforms.
Visual Trigger- Capture signals on two channels with Visual triggering with multiple
defined areas and markers showing repeat occurrences.
Navigation and search
Versatile trigger and search
Finding your event of interest in a long waveform record can be time
consuming without the right search tools. With today's record lengths
pushing beyond a million data points, locating your event can mean
scrolling through thousands of screens of signal activity.
Discovering a device fault is only the first step. Next, you must capture the
event of interest to identify root cause. The MSO/DPO5000B Series
provides a complete set of triggers - including runt, glitch, width, timeout,
transition, pattern, state, setup/hold violation, serial packet, and parallel
data - to help quickly find your event.
The MSO/DPO5000B Series offers the industry's most comprehensive
®
search and waveform navigation with its innovative Wave Inspector
controls. These controls speed panning and zooming through your record.
With a unique force-feedback system, you can move from one end of your
record to the other in just seconds. User marks allow you to mark any
location that you may want to reference later for further investigation. Or,
automatically search your record for criteria you define. Wave Inspector will
instantly search your entire record, including analog, digital, and bus data.
Along the way it will automatically mark every occurrence of your defined
event so you can quickly move between events. The standard Advanced
Search and Mark capability of the MSO/DPO5000B Series can even search
for up to eight different events simultaneously and stop a live acquisition
when it finds an event of interest, saving even more time.
Visual trigger
Finding the right characteristic of a complex signal can require hours of
collecting and sorting through thousands of acquisitions for the event of
interest. Defining a trigger that isolates the desired event and shows data
only when the event occurs speeds up this process. Visual Trigger and
Search makes the identification of the desired waveform events quick and
easy by scanning through all waveform acquisitions and comparing them to
on-screen areas (geometric shapes). Areas can be created using a variety
of shapes including triangles, rectangles, hexagons, trapezoids, and user-
specified shapes to fit the area to the particular trigger behavior desired.
Set up to eight areas and condition based on Boolean logic conditions.
www.tek.com/MSO5000
5
Datasheet
The standard limit test package enables long-term signal monitoring,
characterizing signals during design, and production line testing. Limit test
compares a tested signal to a known good or "golden" version of the same
signal with user-defined vertical and horizontal tolerances. You can tailor a
limit test to your specific requirements by defining test duration in a number
of waveforms, setting a violation threshold that must be met before
considering a test a failure, counting hits with statistical information, and
setting actions upon violations, test failure, and test complete.
Custom analysis
When signal analysis needs extend beyond the standard or optional
analysis features, the Microsoft Windows 10 based MSO/DPO5000B series
has the flexibility to support custom analysis. Apply your custom algorithms
using custom MATLAB and .NET math plug-ins for analysis functions that
are integrated in the oscilloscope user interface for more seamless
operation.
Search - Results of an advanced search for a runt pulse or a narrow glitch within a long
waveform record.
Comprehensive analysis
Verifying that your prototype's performance matches simulations and meets
the project's design goals requires analyzing its behavior. Tasks can range
from simple checks of rise times and pulse widths to sophisticated power
loss analysis, characterization of system clocks, and investigation of noise
sources. The MSO/DPO5000B Series offers a comprehensive set of
integrated analysis tools including waveform- and screen-based cursors,
53 automated measurements, advanced waveform math including arbitrary
equation editing, waveform histograms, and FFT analysis.
Custom analysis - Waterfall display generated from oscilloscope data using MATLAB.
Jitter analysis
Every MSO/DPO5000B Series oscilloscope includes the DPOJET
Essentials jitter and eye pattern analysis software package, extending the
oscilloscope's measurement capabilities to take measurements over
contiguous clock and data cycles in a single-shot real-time acquisition. This
enables measurement of key jitter and timing analysis parameters such as
Time Interval Error and Phase Noise to help characterize possible system
timing issues. Analysis tools such as plots for time trends and histograms
quickly show how timing parameters change over time, and spectrum
analysis quickly shows the precise frequency and amplitude of jitter and
modulation sources.
Analyze - Waveform histogram of the rising and falling edge of a 622 Mb/s signal
showing the distribution of edge position (jitter) over time. Included are numeric
measurements made on the waveform histogram data.
6 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
DDR memory bus analysis (optional)
The optional DDR memory analysis software package (Option DDRA)
automatically identifies DDR1, DDR2, LP-DDR, and LP-DDR2 Reads and
Writes and makes JEDEC conformance measurements with Pass/Fail
results on all edges in every Read and Write burst, perfect for debugging
and troubleshooting DDR memory buses. Also provided are common
measurements of clock, address, and control signals. Used with DPOJET
(Option DJA), Option DDRA is the fastest way to debug complex memory
signaling issues.
Vector signal analysis (optional)
™
The optional SignalVu vector signal analysis package (Option SVE) easily
validates wideband designs and characterizes wideband spectral events.
By combining the signal analysis engine of Tektronix real-time spectrum
analyzers with the wide bandwidth acquisition of Tektronix digital
Jitter analysis - TIE jitter/timing analysis of 622 Mb/s signal
oscilloscopes, you can now evaluate complex baseband signals directly on
your oscilloscope. You get the functionality of a vector signal analyzer, a
spectrum analyzer, and the powerful trigger capabilities of a digital
oscilloscope - all in a single package. Whether your design validation needs
include wideband radar, high data-rate satellite links, or frequency hopping
Extend jitter/timing analysis with the optional DPOJET Advanced software
package (Option DJA). DPOJET Advanced adds advanced tools such as
Rj/Dj separation, eye diagram masks, and Pass/Fail limits for conformance
testing. DPOJET Advanced is also a measurement framework that works
with standards-specific compliance test packages for applications such as
DDR memory and USB 2.0.
™
communications, SignalVu vector signal analysis software can speed
your time-to-insight by showing you time-variant behavior of these
wideband signals.
Power analysis (optional)
The optional power analysis software package (Option PWR) enables quick
and accurate analysis of power quality, switching loss, harmonics, magnetic
measurements, safe operating area (SOA), modulation, ripple, amplitude
and timing measurements, and slew rate (di/dt, dv/dt). Automated,
repeatable power measurements are available with a touch of a button; no
external PC or complex software setup is required. The package includes a
report generation tool to automatically create detailed reports to document
your measurement results.
Automated power measurements enable quick and accurate analysis of
common power parameters.
™
SignalVu enables detailed analysis in multiple domains.
Switching Loss measurements.
www.tek.com/MSO5000
7
Datasheet
Event table display
Protocol triggering and analysis (optional)
In addition to seeing decoded packet data on the bus waveform itself, you
can view all captured packets in a tabular view much like you would see in
a software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.).
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difficult. The
MSO/DPO5000B Series offers a robust set of tools for debugging serial
buses with automatic trigger and decode on I2C, SPI, CAN, LIN, FlexRay,
RS-232/422/485/UART, MIL-STD-1553, Ethernet, and USB 2.0, and
decode for 8b/10b, PCI Express, and MIPI D-PHY DSI-1 and CSI-2 serial
buses.
Event table showing decoded SPI serial packet data with bus timing waveform for a long
acquisition.
Triggering on a USB full-speed serial bus. A bus waveform provides decoded packet
content including Start, Sync, PID, Address, End Point, CRC, Data values, and Stop.
Compliance testing
Serial bus compliance test (optional)
Serial triggering
Software packages for automated compliance test are available for
Ethernet 10BASE-T, 10BASE-Te, 100BASE-TX, and 1000BASE-T (Option
ET3), MOST50 and MOST150 electrical (Option MOST), BroadR-Reach/
100BASE-T1 and 1000BASE-T1 (Option BRR), and USB 2.0 (Option
USB2) physical-layer devices. These software packages enable you to
conduct testing using the standard's specified compliance tests.
Trigger on packet content such as start of packet, specific addresses,
specific data content, unique identifiers, etc. on popular serial interfaces
such as I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-
STD-1553, Ethernet, and USB 2.0.
Bus display
Provides a higher-level, combined view of the individual signals (clock,
data, chip enable, etc.) that make up your bus, making it easy to identify
where packets begin and end and identifying subpacket components such
as address, data, identifier, CRC, etc.
Bus decoding
Tired of having to visually inspect the waveform to count clocks, determine
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
value? Let the oscilloscope do it for you! Once you've set up a bus, the
MSO/DPO5000B Series will decode each packet on the bus, and display
the value in hex, binary, decimal (USB only) or ASCII (USB and
RS-232/422/485/UART only) in the bus waveform.
USB 2.0 Compliance Testing.
8 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Mask testing
Floating licenses
The optional mask test (Option MTM) software package is useful for long-
term signal monitoring, characterizing signals during design, and production
line testing. The mask test software includes a robust set of masks for
telecommunications and computer standards for easily checking
compliance to a standard. Additionally, custom masks can be created and
used for characterizing signals. With mask testing you can tailor a test to
your specific requirements by defining test duration in a number of
waveforms, setting a violation threshold that must be met before
considering a test a failure, counting hits with statistical information, and
setting actions upon violations, test failure, and test complete.
Floating licenses offer an alternative method to manage your Tektronix
asset. Floating licenses allow license-key enabled options to be easily
moved among all your MSO/DPO5000, DPO7000, and DPO/DSA/
MSO70000 Series of Tektronix oscilloscopes. Floating licenses are
available for many license-key enabled options. To order a floating version
of an option license add “DPOFL-“ prefix to the option name. (e.g. DPOFL-
ET3)
Check www.tek.com for additional information about floating license
options.
Easy data storage
Designed to make your work easier
Two USB 2.0 host ports on the front panel enable easy transfer of
screenshots, instrument settings, and waveform data to a USB flash drive.
Large, high-resolution touchscreen display
The rear panel contains four additional USB 2.0 host ports and a USB
device port for controlling the oscilloscope remotely from a PC or for
connecting USB peripherals. An integrated 10/100/1000BASE-T Ethernet
port enables easy connection to networks and a Video Out port to drive an
external monitor or projector. A standard ≥ 480 GB removable solid state
disk drive makes customizing settings for different users easy and enables
use in secure environments.
The MSO/DPO5000B Series features a 10.4 in. (264 mm) XGA color
display with an integrated touch screen for seeing intricate signal details.
Connectivity and remote operation
There are many ways to connect to your MSO/DPO5000B Series
oscilloscope to conduct extended analysis. The first makes use of the
Windows Remote Desktop capability – connect directly to your oscilloscope
and operate the user interface remotely through the built-in Remote
®
Desktop. A second way to connect is through Tektronix OpenChoice
software which makes use of the fast embedded bus, transferring
waveform data directly from acquisition to analysis applications on the
Windows desktop at much faster speeds than conventional GPIB transfers.
™
Industry-standard protocols, such as TekVISA interface and ActiveX
controls are included for using and enhancing Windows applications for
data analysis and documentation. IVI-COM instrument drivers are included
to enable easy communication with the oscilloscope using GPIB, serial
data, and LAN connections from programs running on the instrument or an
external PC. Or, use the Software Developer's Kit (SDK) to help create
custom software to automate multistep processes in waveform collection
and analysis with Visual BASIC, C, C++, MATLAB, LabVIEW,
LabWindows/CVI, and other common Application Development
Environments (ADE).
High resolution display quality with touch screen, mouse and stylus operation.
Dedicated front panel controls
Per-channel vertical controls provide simple and intuitive operation. No
longer do you need to share one set of vertical controls across all four
channels.
www.tek.com/MSO5000
9
Datasheet
™
TekScope Anywhere off-line analysis
For mixed-domain analysis or greater portability, the MDO4000 and
MDO3000 series offer:
™
TekScope Anywhere brings the power of the oscilloscope analysis
environment to the PC. Users now have the flexibility to perform analysis
tasks including timing, eye, and jitter analysis outside the lab. Waveform
data and setups 1 from Tektronix MDO3000, MDO4000, MSO/DPO5000,
DPO7000C, or MSO/DPO70000C/D/DX/SX Series oscilloscopes can
quickly be shared among team members and remote sites, resulting in
improved efficiency.
100 MHz to 1 GHz bandwidth
Up to 5 GS/s sampling
Up to 20 M point record length
Serial data trigger and decode
Built-in 3 GHz or 6 GHz spectrum analyzer (optional)
2 or 4 analog channels and 16 digital channels (optional)
Tektronix Mid-range Oscilloscopes
Need more performance or have other application needs? Consider the
DPO7000, MDO4000, or MDO3000 series.
For more performance, the DPO7000C series offers:
500 MHz to 3.5 GHz bandwidth
Up to 40 GS/s sampling rate
Up to 500 M point record length
1 % accuracy
More analysis and compliance support for higher data rates
Microsoft Windows 10
1
Setups for MSO/DPO5000/B, DPO7000C, MSO/DPO70000C/D/DX/SX models only.
10 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Specifications
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
Model overview
MSO5034B
DPO5034B
MSO5054B
DPO5054B
MSO5104B
DPO5104B
MSO5204B
DPO5204B
Input Channels
4
Bandwidth
350 MHz
1 ns
500 MHz
700 ps
1 GHz
350 ps
2 GHz
175 ps
Rise Time (Calculated)
DC Gain Accuracy
Bandwidth Limits
±1.5%, derated at 0.10%/°C above 30 °C
Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, and 20 MHz
Effective Number of Bits (Typical)
6 bits (10 divisionp-p sine wave input at instrument bandwidth, 100 mV/div, 50 Ω Input Impedance, maximum sample rate, 1 k
point record length)
Random Noise (RMS, typical, sample mode, full BW, 50 Ω)
1 mV/div
2 mV/div
5 mV/div
10 mV/div
20 mV/div
50 mV/div
100 mV/div
1 V/div
173 μV
216 μV
231 μV
305 μV
504 μV
1.15 mV
2.40 mV
22.96 mV
178 μV
236 μV
281 μV
340 μV
523 μV
1.17 mV
2.46 mV
22.98 mV
5 GS/s
68 μV
70 μV
128 μV
214 μV
315 μV
547 μV
1.29 mV
3.08 mV
23.15 mV
5 GS/s
158 μV
307 μV
485 μV
791 μV
1.82 mV
4.75 mV
29.58 mV
5 GS/s
Maximum Sample Rate (All channels) 5 GS/s
Maximum Sample Rate (1 or
2 channels)
5 GS/s
5 GS/s
10 GS/s
10 GS/s
Maximum Equivalent Time Sampling 400 GS/s
Rate
Maximum Record Length with
Standard Configuration
25 M
25 M (4 ch)
50 M (1 or 2 ch)
Maximum Record Length with Option 50 M
5RL
50 M (4 ch)
125 M (1 or 2 ch)
Maximum Record Length with Option 125 M
10RL
125 M (4 ch)
250 M (1 or 2 ch)
Vertical system analog channels
Input coupling
AC, DC
Input resistance
Input sensitivity range
1 MΩ ±1%, 50 Ω ±1%
1 MΩ: 1 mV/div to 10 V/div
50 Ω: 1 mV/div to 1 V/div
Vertical resolution
8 bits (>11 bits with Hi Res)
www.tek.com/MSO5000 11
Datasheet
Vertical system analog channels
Maximum input voltage, 1 MΩ
300 VRMS CAT II, with peaks ≤ ±425 V
For <100 mV/div derate at 20 dB/decade above 100 kHz to 30 VRMS at 1 MHz, 10 dB/decade above 1 MHz
For ≥100 mV/div derate at 20 dB/decade above 3 MHz to 30 VRMS at 30 MHz, 10 dB/decade above 30 MHz
Maximum input voltage, 50 Ω
Position range
5 VRMS, with peaks ≤ ±20 V
±5 divisions
Delay between any Two Channels ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)
(Typical)
Offset range
1 mV/div - 50 mV/div
50.5 mV/div - 99.5 mV/div
100 mV/div - 500 mV/div
505 mV/div - 995 mV/div
1 V/div - 5 V/div
1 MΩ: ±1 V
50 Ω: ±1 V
1 MΩ: ±0.5 V
50 Ω: ±0.5 V
1 MΩ: ±10 V
50 Ω: ±10 V
1 MΩ: ±5 V
50 Ω: ±5 V
1 MΩ: ±100 V
50 Ω: ±5 V
5.05 V/div - 10 V/div
1 MΩ: ±50 V
50 Ω: NA
Offset Accuracy
±(0.005 × |offset – position| + DC Balance)
Note: Both position and constant offset term must be converted to volts by multiplying by the appropriate volts/div term
Channel-to-channel isolation (Any ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated BW
two channels at equal vertical
scale settings) (typical)
Vertical system digital channels
Input Channels
16 Digital (D15 - D0)
Per-channel Thresholds
TTL, ECL, User
Thresholds
Threshold Selections
User-defined Threshold Range
Threshold Accuracy
Maximum Input Voltage
Input Dynamic Range
±40 V
±(100 mV + 3% of threshold setting)
±42 Vpeak
30 Vp-p ≤200 MHz
10 Vp-p >200 MHz
Minimum Voltage Swing
400 mV
12 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Vertical system digital channels
Input Impedance
100 kΩ
Probe Loading
3 pF
1 bit
Vertical Resolution
Horizontal system analog channels
Maximum Duration at Highest
Real-Time Sample Rate
25 ms
Time Base Range
12.5 ps/div to 8,000,000 s/div
2.5 ps/div
Time resolution (in ET/IT mode)
Time base delay time range
–10 divisions to 1000 s
Channel-to-channel deskew range ±75 ns
Time base accuracy
±5 ppm over any ≥1 ms interval
Horizontal system digital channels
Maximum Sample Rate (Main)
Maximum record length (main)
500 MS/s (2 ns resolution)
25 M Standard
Up to 40 M with Record Length options
Maximum sample rate (MagniVu)
16.5 GS/s (60.6 ps resolution)
Maximum record length (MagniVu) 10k points centered around the trigger
Minimum detectable pulse width 1 ns
Channel-to-channel skew (typical) 200 ps
Maximum input toggle rate
500 MHz at minimum input swing; higher toggle rates can be achieved at higher amplitudes
Trigger system
Main trigger modes
Auto, Normal, and Single
Trigger coupling
Trigger holdoff range
Enhanced triggering
Trigger jitter
DC, AC, HF Rej (attenuates >50 kHz), LF Rej (attenuates <50 kHz), Noise Reject (reduces sensitivity)
250 ns to 8 s
User-selectable; corrects the difference in timing between the trigger path and the acquired data (not available in FastAcq)
≤100 fsRMS using Enhanced Trigger
≤10 psRMS without Enhanced Trigger and in Fast Acq mode
≤100 psRMS for non-Edge-type trigger modes
www.tek.com/MSO5000 13
Datasheet
Trigger system
Trigger sensitivity
Internal DC coupled
For 1 MΩ: 1 mV/div to 4.98 mV/div: 0.75 div from DC to 50MHz, increasing to 1.3 div at instrument bandwidth ≥5 mV/div: 0.40 div
from DC to 50 MHz, increasing to 1 div at instrument bandwidth
For 50 Ω (MSO5204, DPO5204, MSO5104, DPO5104): 0.40 div from DC to 50 MHz, increasing to 1 div at instrument bandwidth
For 50 Ω (MSO5054, DPO5054, MSO5034, DPO5034): 1 mV/div to 4.98 mV/div: 0.75 div from DC to 50MHz, increasing to 1.3 div
at instrument bandwidth ≥5 mV/div: 0.40 div from DC to 50 MHz, increasing to 1 div at instrument bandwidth
External (auxiliary input) 1 MΩ 200 mV from DC to 50 MHz, increasing to 500 mV at 250 MHz
Trigger level range
Any channel
±8 divisions from center of screen
±8 V
External (auxiliary input)
Line
Fixed at about 50% of line voltage
Trigger modes
Edge
Positive, negative, or either slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and
noise reject
Glitch
Trigger on or reject glitches of positive, negative, or either polarity. Programmable glitch width is 4 ns minimum to 8 s maximum
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again
Trigger on width of positive or negative pulse either within or outside selectable limits (4 ns to 8 s)
Runt
Width
Timeout
Transition
Setup/Hold
Pattern
Trigger on an event which remains high, low, or either, for a specified time period (4 ns to 8 s)
Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either
Trigger on violations of both setup time and hold time between clock and data present on any two input channels
Trigger when any logical pattern of signals goes false or stays true for specified period of time (4 ns to 1 s). Pattern (AND, OR,
NAND, NOR) specified for all analog and digital input channels defined as High, Low, or Don't Care
Parallel Bus
State
Trigger on specified data value on defined parallel bus
Any logical pattern of analog channels and digital channels (MSO models) clocked by edge on another channel. Trigger on rising
or falling clock edge
Video
Trigger on all lines, specific line number, odd, even, or all fields on NTSC, PAL, SECAM, and HDTV 480p/60, 576p/50, 875i/60,
720p/30, 720p/50, 720p/60, 1080/24sF, 1080i/50, 1080p/25, 1080i/60, 1080p/24, 1080p/25, 1080p/50, 1080p/60, Bi-level, Tri-level
Trigger Sequences
Main, Delayed by Time, Delayed by Events. All sequences can include separate horizontal delay after the trigger event to position
the acquisition window in time
A/B Sequence Event Trigger
Types
Edge
Trigger Delay by Time
Trigger Delay by Events
Visual Trigger
4 ns to 8 s
1 to 4,000,000 events
Trigger on up to 8 user-specified areas, including rectangle, triangle, trapezoid, hexagon, and user-specified shapes on any of the
analog channels
I2C (Optional)
Provided as part of Opt. SR-EMBD. Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address
and Data on I2C buses up to 10 Mb/s
SPI (Optional)
CAN (Optional)
Provided as part of Opt. SR-EMBD. Trigger on Slave Select, Idle Time, or Data (1-16 words) on SPI buses up to 10 Mb/s
Provided as part of Opt. SR-AUTO. Trigger on Start of Frame, Type of Frame (Data, Remote, Error, or Overload), Identifier, Data,
Identifier and Data, EOF, Missing Ack, Bit Stuff Error, and CRC Error on CAN buses up to 1 Mb/s
LIN (Optional)
Provided as part of Opt. SR-AUTO. Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, and Error
on LIN buses up to 1 Mb/s
FlexRay (Optional)
Provided as part of Opt. SR-AUTO. Trigger on Indicator Bits (Normal, Payload, Null, Sync, Startup), Cycle Count, Header Fields
(Indicator Bits, Identifier, Payload Length, Header CRC, and Cycle Count), Identifier, Data, Identifier and Data, End Of Frame, and
Error on FlexRay buses up to 10 Mb/s
MIL-STD-1553 (Optional)
Provided as part of Opt. SR-AERO. Trigger on Sync, Command Word, Status Word, Data Word, Idle Time, and Error on MIL-
STD-1553 buses up to 1 Mb/s
14 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Trigger system
Ethernet (Optional)
Provided as part of Opt. SR-ENET. Trigger on Start of Packet, MAC Address, MAC Q-tag, MAC Length/Type, MAC Data, IP
Header, TCP Header,
TCP/IPV4 Data, End of Packet, and FCS(CRC) Error on 10BASE-T and 100BASE-TX buses.
RS-232/422/485/UART
(Optional)
Provided as part of Opt. SR-COMP. Trigger on Start Bit, End of Packet, Data, and Parity Error up to 10 Mb/s
USB 2.0 Low Speed:
(Optional)
Provided as part of Opt. SR-USB.
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token Packet Trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any, OUT, IN, and SETUP token
types. Address can be further specified to trigger on ≤, <, =, >, ≥, != a particular value, or inside or outside a range. Frame number
can be specified for SOF token using Binary, Hex, Unsigned Decimal, and Don't Care digits.
Data Packet Trigger – Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, != a particular data
value, or inside or outside a range.
Handshake Packet Trigger – Any handshake type, ACK, NAK, STALL.
Special Packet Trigger – Any special type, Reserved.
Error Trigger – PID Check, CRC5 or CRC16, Bit Stuffing.
USB 2.0 Full Speed: (Optional) Provided as part of Opt. SR-USB.
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token Packet Trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any, OUT, IN, and SETUP token
types. Address can be further specified to trigger on ≤, <, =, >, ≥, != a particular value, or inside or outside a range. Frame number
can be specified for SOF token using Binary, Hex, Unsigned Decimal, and Don't Care digits.
Data Packet Trigger – Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, != a particular data
value, or inside or outside a range.
Handshake Packet Trigger – Any handshake type, ACK, NAK, STALL.
Special Packet Trigger – Any special type, PRE, Reserved.
Error Trigger – PID Check, CRC5 or CRC16, Bit Stuffing.
Provided as part of Opt. SR-USB.
USB 2.0 High Speed:
(Optional)
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token Packet Trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any, OUT, IN, and SETUP token
types. Address can be further specified to trigger on ≤, <, =, >, ≥, != a particular value, or inside or outside a range. Frame number
can be specified for SOF token using Binary, Hex, Unsigned Decimal, and Don't Care digits.
Data Packet Trigger – Any data type, DATA0, DATA1, DATA2, DATAM; Data can be further specified to trigger on ≤, <, =, >, ≥, !=
a particular data value, or inside or outside a range.
Handshake Packet Trigger – Any handshake type, ACK, NAK, STALL, NYET.
Special Packet Trigger – Any special type, ERR, SPLIT, PING, Reserved. SPLIT packet components that can be specified include:
Hub Address
Start/Complete – Don't Care, Start (SSPLIT), Complete (CSPLIT) Port Address
Start and End bits – Don't Care, Control/Bulk/Interrupt (Full-speed Device, Low-speed Device), Isochronous (Data is Middle, Data
is End, Data is Start, Data is All)
Endpoint Type – Don't Care, Control, Isochronous, Bulk, Interrupt
Error Trigger – PID Check, CRC5, CRC16, Any.
Note: USB 2.0 High-speed triggering, decoding, and search only available on 1 GHz and 2 GHz models.
www.tek.com/MSO5000 15
Datasheet
Acquisition system
Acquisition modes
Sample
Acquire sampled values
Peak detect
Captures narrow glitches as narrow as 100 ps (2 GHz and 1 GHz models) or 200 ps (500 MHz and 350 MHz models) at all real-
time sampling rates
Averaging
Envelope
Hi-Res
From 2 to 10,000 waveforms included in average
Min-Max envelope reflecting Peak Detect data over multiple acquisitions
Real-time boxcar averaging reduces random noise and increases resolution
Roll mode
Scrolls sequential waveform points across the display in a right-to-left rolling motion at sweep speeds slower than 50 ms/div. Up to
20 MS/s with a maximum record length of 10 M
®
FastAcq
FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events
Maximum FastAcq waveform >250,000 wfms/s on all 4 channels simultaneously
capture rate
Waveform database
Accumulate waveform database providing three-dimensional array of amplitude, time, and counts
™
FastFrame
Acquisition memory divided into segments; maximum trigger rate >310,000 waveforms per second. Time of arrival recorded with
each event. Frame finder tool helps to visually identify transients
Automated Search and Mark
Automatically mark events and document waveforms. Search positive/negative slopes or both, glitches, runts, pulse widths,
transition rate, setup and hold, timeout, windows, or find any logic or state pattern, up to 8 different event types on any of the
4 analog channels. Search DDR Read or Write bursts with Opt. DDRA. Event table summarizes all found events. All events are
time stamped in reference to trigger position. Stop acquisitions when an event is found
Waveform analysis
Waveform measurements
Cursors
Waveform and Screen
Automatic measurements
53, of which 8 can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time, Fall
Time, Positive Duty Cycle, Negative Duty Cycle, Positive Width, Negative Width, Burst Width, Phase, Positive Overshoot, Negative
Overshoot, Peak-to-Peak, Amplitude, High, Low, Maximum, Minimum, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area
Eye-pattern measurements
Extinction Ratio (absolute, %, dB), Eye Height, Eye Width, Eye Top, Eye Base, Crossing %, Jitter (p-p, RMS, 6sigma), Noise (p-p,
RMS), Signal/Noise Ratio, Cycle Distortion, Q-Factor
Measurement statistics
Reference levels
Gating
Mean, Minimum, Maximum, Standard Deviation
User-definable reference levels for automatic measurements can be specified in either percent or units
Isolate the specific occurrence within an acquisition to take measurements on, using either screen or waveform cursors
Waveform histogram
A waveform histogram provides an array of data values representing the total number of hits inside a user-defined region of the
display. A waveform histogram is both a visual graph of the hit distribution and a numeric array of values that can be measured.
Sources – Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math 1, Math 2, Math 3, Math 4
Types – Vertical, Horizontal
Waveform histogram
measurements
Waveform Count, Hits in Box, Peak Hits, Median, Maximum, Minimum, Peak-to-Peak, Mean (μ), Standard Deviation (sigma),
μ +1sigma, μ +2sigma, μ +3sigma
Waveform processing/math
Arithmetic
Add, Subtract, Multiply, Divide waveforms and scalars
Algebraic expressions
Define extensive algebraic expressions including waveforms, scalars, user-adjustable variables, and results of parametric
measurements. Perform math on math using complex equations. e.g. (Integral (CH1 – Mean(CH1)) × 1.414 × VAR1)
Math functions
Relational
Average, Invert, Integrate, Differentiate, Square Root, Exponential, Log10, Log e, Abs, Ceiling, Floor, Min, Max, Sin, Cos, Tan,
ASin, ACos, ATan, Sinh, Cosh, Tanh
Boolean result of comparison >, <, ≥, ≤, ==, !=
Frequency domain functions Spectral Magnitude and Phase, Real and Imaginary Spectra
(FFT)
FFT vertical units
Magnitude: Linear, dB, dBm
Phase: Degrees, radians, group delay
16 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Waveform analysis
FFT window functions
Waveform definition
Filtering functions
Custom math functions
Mask function
Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential
As an arbitrary math expression
User-definable filters. Users specify a filter containing the coefficients of the filter. Filter files provided
Custom MATLAB and .NET plug-ins can be included in the math waveform definition
A function that generates a waveform database pixmap from a sample waveform. Sample count can be defined
Software
IVI driver
Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI,
Microsoft .NET and MATLAB. IVI-COM standard
LXI Class C web interface
Connect to the MSO/DPO5000B Series through a standard Web browser by simply entering the oscilloscope's IP address in the
address bar of the browser. The web interface enables viewing of instrument status and configuration, as well as status and
modification of network settings. All web interaction conforms to LXI Class C specification
Display system
Display type
10.4 in. (264 mm) liquid-crystal active-matrix color display with touch screen
1024 horizontal × 768 vertical pixels (XGA)
Display resolution
Waveform styles
Color palettes
Vectors, dots, variable persistence, infinite persistence
Normal, green, gray, temperature, spectral, and user defined
YT, XY
Display format
Computer system
Operating system
Microsoft Windows 10 Enterprise IoT Edition
Intel i5-4400E 2.7 GHz processor
CPU
PC system memory
Solid state disk drive
Mouse
≥4 GB
Removable solid state disk drive, 512 GB
Optical wheel mouse, USB interface
Order 119-7083-xx for small keyboard; USB interface and hub
Keyboard
www.tek.com/MSO5000 17
Datasheet
Input output ports
USB 2.0 High-speed host ports
Supports USB mass storage devices, printers, keyboard, and mouse. Two ports on front and four ports on rear of instrument. Can
be disabled individually
USB 1.1 Full-speed device port
LAN port
Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488 adapter)
RJ-45 connector, supports 10/100/1000BASE-T
Video out port
DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector. Support for extended
desktop and clone mode
Audio ports
Miniature phono jacks
Keyboard port
Mouse port
PS/2 compatible
PS/2 compatible
Auxiliary input
Front-panel BNC connector. Input impedance 1 MΩ. Max input 300 VRMS with peaks ≤ ±425 V
Auxiliary out (software switchable) Trigger Out: A TTL compatible pulse when the oscilloscope triggers
Time Base Reference Out: A TTL compatible output of internal 10 MHz reference oscillator
External reference in
Time base system can phase lock to an external 10 MHz reference (10 MHz ±1%)
Probe compensator output
Front-panel pins
Amplitude: 2.5 V
Frequency: 1 kHz
LAN eXtensions for
Instrumentation (LXI)
Class: LXI Class C Version: 1.3
®
Optional TekVPI external power
Required when total oscilloscope probe power usage exceeds 15 W.
supply
Output Voltage
Output Current
Power Consumption
12 V
5 A
50 W
Power source
Power source voltage
100 to 240 V ±10%
Power source frequency
Power consumption
45 Hz to 66 Hz (85 to 264 V)
360 Hz to 440 Hz (100 to 132 V)
275 W maximum
18 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Physical characteristics
Dimensions
mm
233
439
206
in.
Height
Width
Depth
9.16
17.29
8.12
Weight
kg
lb.
Net
6.7
12.5
14.9
27.5
Shipping
Rackmount configuration
Cooling clearance
5U
in.
0
mm
0
Top
Bottom
Left Side
Right Side
Front
0
0
2
51
0
0
0
0
Rear
2
51
EMC environmental and safety
Temperature
Operating
0 °C to +50 °C
–20 °C to +60 °C
Nonoperating
Humidity
Operating
8% to 90% relative humidity with a maximum wet-bulb temperature of 29 °C at or below +50 °C (upper limit de-rates to 20.6%
relative humidity at +50 °C). Noncondensing
Nonoperating
5% to 98% relative humidity with a maximum wet-bulb temperature of 40 °C at or below +60 °C (upper limit de-rates to 29.8%
relative humidity at +60 °C). Noncondensing
Altitude
Operating
3,000 m (9,843 ft.)
9,144 m (30,000 ft.)
Nonoperating
Regulatory
Electromagnetic compatibility 2004/108/EC
Certifications UL61010-1; CSA61010-1, EN61010-1; IEC 61010-1
www.tek.com/MSO5000 19
Datasheet
Ordering information
DPO5000B models
DPO5034B
DPO5054B
DPO5104B
DPO5204B
350 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscope
500 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscope
1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscope
2 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscope
MSO5000B models
MSO5034B
350 MHz, 5 GS/s, 25 M record length, 4+16 channel mixed signal oscilloscope
500 MHz, 5 GS/s, 25 M record length, 4+16 channel mixed signal oscilloscope
1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4+16 channel mixed signal oscilloscope
2 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4+16 channel mixed signal oscilloscope
MSO5054B
MSO5104B
MSO5204B
Standard accessories
TPP0500B
One passive voltage probe per analog channel (500 MHz, 10X, 3.9 pF) for 500 MHz and 350 MHz models
TPP1000
One passive voltage probe per analog channel (1 GHz, 10X, 3.9 pF) for 2 GHz and 1 GHz models
200-5130-xx
Front cover
119-6107-xx
Touch-screen stylus
071-298x-xx
User Manual (please specify language when ordering)
—
Advanced Search and Mark, DPOJET Essentials, Visual Trigger and Search, and Limit Test all included standard
—
Accessory pouch
—
Mouse
—
Calibration Certificate documenting measurement traceability to National Metrology Institute(s), Z 540-1 Compliance and ISO9001
—
Power Cord (please specify power plug option when ordering)
One-year warranty
—
P6616
16-channel logic probe for MSO Models
Logic probe accessory kit for MSO Models
020-2662-xx
Options
Record length options
Option
MSO5034B
DPO5034B
MSO5054B
DPO5054B
MSO5104B
DPO5104B
MSO5204B
DPO5204B
Opt. 5RL
50 M/Ch
125 M max, 50 M/Ch
250 M max, 125 M/Ch
Opt. 10RL
125 M/Ch
20 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Advanced analysis options
Option
Description
Opt. BRR
BroadR-Reach/100BASE-T1 and 1000BASE-T1 Compliance Testing (Requires TF-GBE-BTP and TF-BRR-CFD Test Fixtures) (Available on
1 GHz and 2 GHz models only.)
Opt. DDRA
Opt. DJA
DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only.)
Jitter and Eye Analysis Tools – Advanced (DPOJET)
Opt. DJAN
Opt. CMENET3
Opt. ET3
DPOJET Noise, jitter, and eye analysis tools (Requires Opt. DJA)
TekExpress Ethernet Automated 10/100/1000 BASE-T Solution (or purchase Opt. CMENET3A if you already have Opt. ET3)
Ethernet compliance test (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)
MOST Essentials – Electrical compliance and debug test solution for MOST50 and MOST150 (Requires Opt. DJA)
Opt. MOST
Opt. MTM
Mask testing
– ITU-T (64 Kb/s to 155 Mb/s)
– ANSI T1.102 (1.544 Mb/s to 155 Mb/s)
– Ethernet IEEE 802.3, ANSI X3.263 (125 Mb/s to
1.25 Gb/s)
– SONET/SDH (51.84 Mb/s to 622 Mb/s)
– Fibre Channel (133 Mb/s to 2.125 Gb/s)
– Fibre Channel Electrical (133 Mb/s to 1.06 Gb/s)
– USB (12 Mb/s to 480 Mb/s)
– IEEE 1394b (491.5 Mb/s to 1.966 Gb/s)
– Rapid I/O Serial (up to 1.25 Gb/s)
– Rapid I/O LP-LVDS (500 Mb/s to 1 Gb/s)
– OIF Standards (1.244 Gb/s)
– CPRI, V4.0 (1.228 Gb/s)
– Video (143.18 Mb/s to 360 Mb/s)
Opt. PWR
Power measurement and analysis
Opt. SR-AERO
Aerospace serial triggering and analysis (MIL-STD-1553).
Enables triggering on packet-level information on MIL-STD-1553 buses and analytical tools such as bus views, packet decoding, search tools,
and packet decode tables with time stamp information.
Signal Inputs – Any Ch1 - Ch4
Recommended probing – Differential
Opt. SR-AUTO
Opt. SR-COMP
Opt. SR-DPHY
Opt. SR-EMBD
Opt. SR-ENET
Automotive serial triggering and analysis (CAN/LIN/FlexRay).
Enables triggering on packet-level information on CAN, LIN, and FlexRay buses and analytical tools such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode tables with time stamp information.
Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models)
Recommended probing – LIN: single-ended; CAN/FlexRay: differential
Computer serial triggering and analysis (RS-232/422/485/UART)
Enables triggering on packet-level information on RS-232/422/485/UART buses and analytical tools such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode tables with time stamp information.
Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models)
Recommended probing – RS-232/UART: single ended; RS-422/485: differential
®
MIPI D-PHY serial analysis.
Enables analysis of MIPI DSI-1 and CSI-2 buses with analytical tools such as digital views of the signal, bus views, packet decoding, search
tools, and packet decode tables with time stamp information.
Signal Inputs – Any Ch1 - Ch4
Recommended probing – Differential
Embedded serial triggering and analysis (I2C, SPI)
Enables triggering on packet-level information on I2C and 2-wire and 3-wire SPI buses and analytical tools such as digital views of the signal, bus
views, packet decoding, search tools, and packet decode tables with time stamp information.
Signal Inputs – I2C: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); SPI: Any Ch1 - Ch4 (and any D0 - D15 on MSO models)
Recommended probing – I2C, SPI: single ended
Ethernet serial triggering and analysis (10BASE-T, 100BASE-TX)
Enables triggering on packet-level information on Ethernet buses as well as analytical tools such as bus views, packet decoding, search tools,
and packet decode tables with time stamp information.
Signal Inputs – Any Ch1 - Ch4.
Recommended probing – Differential
www.tek.com/MSO5000 21
Datasheet
Option
Description
Opt. SR-USB
USB 2.0 serial triggering and analysis (LS, FS, HS)
Enables triggering on packet-level content for low-speed, full-speed, and high-speed USB serial buses. Also enables analytical tools such as bus
views, packet decoding, search tools, and packet decode tables with time stamp information for low-speed, full-speed, and high-speed USB serial
buses.
Signal Inputs – Low-speed and Full-speed: Any Ch1 - Ch4 (and any D0 - D15 on MSO models) for single ended, Any Ch1 - Ch4 for differential;
High-speed: Any Ch1 - Ch4
Recommended probing – Low-speed and Full-speed: Single ended or differential; High-speed: Differential (USB high-speed supported only on
1 GHz and 2 GHz models.)
Opt. SSD
Opt. SVA
Opt. SVE
Opt. SVM
Opt. SVP
Opt. SVT
Additional customer-installable removable Solid State Drive with Microsoft Windows 10 OS, TekScope, and applications software installed
AM/FM/PM Audio Signal Analysis (Requires Opt. SVE)
®
SignalVu Essentials – Vector signal analysis software
®
SignalVu General Purpose Modulation Analysis (Requires Opt. SVE)
®
SignalVu Advanced Signal Analysis (including pulse measurements) (Requires Opt. SVE)
®
SignalVu Frequency and Phase Settling Time Measurements (Requires Opt. SVE)
®
Opt. SV26
Opt. USB2
Opt. USBPWR
SignalVu APCO P25 measurements (Requires Opt. SVE)
USB 2.0 Automated Compliance Test Application (Requires TDSUSBF USB Test Fixture. 2 GHz bandwidth required for high-speed USB)
Automated compliance test solution for USB power adapters
Bundle options
These bundled items must be purchased at the same time as the instrument purchase.
Option
Description
Opt. PS2
Opt. PS3
Power Solution Bundle: DPOPWR, THDP0200, TCP0030A, 067-1686-xx (Deskew fixture)
Power Solution Bundle: DPOPWR, TMDP0200, TCP0020, 067-1686-xx (Deskew fixture)
Floating options
Floating licenses offer an alternative method to manage your Tektronix asset. Floating licenses allow license-key enabled options to be easily moved among all your MSO/
DPO5000, DPO7000, and DPO/DSA/MSO70000 Series Tektronix oscilloscopes. Floating licenses are available for the following license-key enabled options.
Check http://www.tek.com/products/oscilloscopes/floatinglicenses for additional information about floating license options.
Option
Description
DPOFL-BRR
BroadR-Reach/100BASE-T1 and 1000BASE-T1 Compliance Testing (Requires TF-GBE-BTP and TF-BRR-CFD Test Fixtures)
(Available on 1 GHz and 2 GHz models only)
DPOFL-DDRA
DPOFL-DJA
DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only)
Jitter and Eye Analysis Tools – Advanced (DPOJET)
DPOFL-DJAN
DPOFL-CMENET3
DPOJET Noise, jitter, and eye analysis tools (Requires Opt. DJA)
TekExpress Ethernet Automated 10/100/1000 BASE-T Solution (or purchase DPOFL-CMENET3A if you already have DPOFL-
CMENET3A)
DPOFL-ET3
Ethernet compliance testing (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet test fixture.)
MOST Essentials – Electrical compliance and debug test solution (MOST50, MOST150) (Requires Opt. DJA)
Mask testing
DPOFL-MOST
DPOFL-MTM
DPOFL-PWR
Power measurement and analysis
DPOFL-SR-AERO
DPOFL-SR-AUTO
DPOFL-SR-COMP
DPOFL-SR-DPHY
DPOFL-SR-EMBD
Aerospace serial triggering and analysis (MIL-STD-1553)
Automotive serial triggering and analysis (CAN/LIN/FlexRay)
Computer serial triggering and analysis (RS-232/422/485/UART)
®
MIPI D-PHY serial analysis
Embedded serial triggering and analysis (I2C, SPI)
22 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
Option
Description
DPOFL-SR-ENET
DPOFL-SR-PCIE
DPOFL-SR-USB
DPOFL-SR-810B
DPOFL-SVA
Ethernet serial triggering and analysis (10BASE-T and 100BASE-TX)
PCI Express serial analysis (Available on ≥1 GHz models only)
USB 2.0 serial triggering and analysis (LS, FS, HS)
8b/10b serial analysis
®
SignalVu AM/FM/PM/Direct Audio measurements (Requires Opt. SVE)
®
DPOFL-SVE
SignalVu Essentials – Vector signal analysis software
®
DPOFL-SVM
DPOFL-SVP
SignalVu General purpose modulation analysis (Requires Opt. SVE)
®
SignalVu Pulse – Advanced signal analysis (Requires Opt. SVE)
®
DPOFL-SVT
SignalVu Settling time measurements (Requires Opt. SVE)
®
DPOFL-SV26
DPOFL-USB2
SignalVu APCO P25 measurements (Requires Opt. SVE)
USB 2.0 Automated Compliance Test Application (Requires TDSUSBF USB Test Fixture. 2 GHz bandwidth required for high-
speed USB)
DPOFL-USBPWR
Automated compliance test solution for USB power adapters
Power plug options
Opt. A0
Opt. A1
Opt. A2
Opt. A3
Opt. A5
Opt. A6
Opt. A10
Opt. A11
Opt. A12
Opt. A99
North America power plug (115 V, 60 Hz)
Universal Euro power plug (220 V, 50 Hz)
United Kingdom power plug (240 V, 50 Hz)
Australia power plug (240 V, 50 Hz)
Switzerland power plug (220 V, 50 Hz)
Japan power plug (100 V, 50/60 Hz)
China power plug (50 Hz)
India power plug (50 Hz)
Brazil power plug (60 Hz)
No power cord
User manual options
Opt. L0
Opt. L1
Opt. L3
Opt. L5
Opt. L7
Opt. L8
Opt. L9
Opt. L10
English manual
French manual
German manual
Japanese manual
Simplified Chinese manual
Traditional Chinese manual
Korean manual
Russian manual
www.tek.com/MSO5000 23
Datasheet
Service options
Opt. C3
Calibration Service 3 Years
Opt. C5
Calibration Service 5 Years
Opt. D1
Calibration Data Report
Opt. D3
Calibration Data Report 3 Years (with Opt. C3)
Calibration Data Report 5 Years (with Opt. C5)
Repair Service 3 Years (including warranty)
Repair Service 5 Years (including warranty)
Opt. D5
Opt. R3
Opt. R5
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty
and calibration terms.
Upgrade options
To upgrade your MSO/DPO5000B Series oscilloscope, order DPO-UP and an option listed below. For example, to add option DDRA, DDR Memory Technology Analysis
Package, order DPO-UP DDRA.
To upgrade record length:
RL25E
From standard 25 M/channel configuration to Opt. 5RL configuration
From standard 25 M/channel configuration to Opt. 10RL configuration
From Opt. 5RL configuration to Opt. 10RL configuration
RL210E
RL510E
To add a solid state hard disk
drive:
SSDE
Add an additional customer-installable removable Solid State Drive assembly with Microsoft Windows 7 OS, TekScope, and
applications software installed
DPO5SSD-W10
Add an additional customer-installable removable Solid State Drive assembly with Microsoft Windows 10 OS, TekScope, and
applications software installed. Note: order DPO5SSD-W10, do not order DPO-UP for this SSD.
To upgrade MSO/DPO5000B Series
with:
BRR
Add Opt. BRR - BroadR-Reach/100BASE-T1 and 1000BASE-T1 Compliance Testing (Requires TF-GBE-BTP and TF-BRR-CFD
Test Fixtures) (Available on 1 GHz and 2 GHz models only)
DDRA
Add Opt. DDRA (Requires Opt. DJA.) (Available on 1 GHz and 2 GHz models only)
Add Opt. DJA – Jitter and Eye Analysis Tools - Advanced (DPOJET)
DJAE
DJAN
Add Opt. DJAN - DPOJET Noise, jitter, and eye analysis tools (Requires Opt. DJA)
CMENET3
Add Opt. CMENET3 - TekExpress Ethernet Automated 10/100/1000 BASE-T Solution (or purchase CMENET3A if you already
have Opt. ET3)
ET3
Add Opt. ET3 – Ethernet Compliance Testing (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)
Add Opt. MOST – MOST Essentials - Electrical Compliance and Debug Test Solution (MOST50, MOST150) (Requires Opt. DJA)
Add Opt. MTM – Mask Testing
MOST
MTM
PWR
Add Opt. PWR – Power Measurement and Analysis
SR-AERO
SR-AUTO
SR-COMP
SR-DPHY
SR-EMBD
SR-ENET
SR-PCIE
SR-USB
Add Opt. SR-AERO – Aerospace Serial Triggering and Analysis (MIL-STD-1553)
Add Opt. SR-AUTO – Automotive Serial Triggering and Analysis (CAN/LIN/FlexRay)
Add Opt. SR-COMP – Computer Serial Triggering and Analysis (RS-232/422/485/UART)
Add Opt. SR-DPHY – MIPI D-PHY Serial Analysis (DSI-1, CSI-2)
Add Opt. SR-EMBD – Embedded Serial Triggering and Analysis (I2C, SPI)
Add Opt. SR-ENET – Ethernet Serial Triggering and Analysis (10BASE-T and 100BASE-TX)
Add PCI Express Serial Analysis (Available on ≥1 GHz models only.)
Add Opt. SR-USB – USB 2.0 Serial Triggering and Analysis (LS, FS, HS)
24 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
SR-810B
SVA
Add 8b/10b Serial Analysis
Add SignalVu AM/FM/Direct Audio Measurements (Requires Opt. SVE)
Add Opt. SVE – SignalVu Essentials - Vector Signal Analysis Software
Add SignalVu General-purpose Modulation Analysis (Requires Opt. SVE)
Add SignalVu Pulse - Advanced Signal Analysis (Requires Opt. SVE)
Add SignalVu Settling Time Measurements - Frequency and Phase (Requires Opt. SVE)
SVEE
SVM
SVP
SVT
®
SV26
USB2
Add Opt. SV26 - SignalVu APCO P25 measurements (Requires Opt. SVE)
Add Opt. USB2 – USB 2.0 Automated Compliance Test Application (Requires TDSUSBF USB Test Fixture) (2 GHz bandwidth
required for high-speed USB)
USBPWR
Add Opt. USBPWR - Automated compliance test solution for USB power adapters
Add 16 digital channels to a DPO5000B
To upgrade DPO5000B Series to
MSO:
MSOE
Recommended accessories
Accessories
077-0076-xx
077-0010-xx
077-0063-xx
TPA-BNC
Service manual (PDF only)
Programmer manual (PDF only)
Performance verification and specifications manual (PDF only)
TekVPI-to-TekProbe BNC adapter
Deskew Pulse Generator
TEK-DPG
TEK-USB-488
HCTEK54
GPIB-to-USB adapter
Hard transit case
RMD5000
Rackmount kit
119-7275-xx
119-8726-xx
Mini multimedia keyboard
TekVPI external power supply – Required when probe power usage exceeds 15 W. Power cord not included. Specify power cord
when ordering.
020-3071-xx
NEX-HD2HEADER2
DPO Demo 3 board with dual-A to single-B USB cable
Mictor connector to square pin adapter
Test fixtures
067-1686-xx
TDSUSBF
Probe Calibration / Power Deskew test fixture
Test fixture for use with Opt. USB2
TF-BRR-CFD
TF-GBE-BTP
TF-GBE-ATP
TF-GBE-EE
Automotive Ethernet Compliance Clock Frequency Divider fixture
Basic test package for 10/100/1000BASE-T Ethernet tests
Advanced test package for 10/100/1000BASE-T Ethernet (includes 1000BASE-T jitter test channel cable)
Additional test fixture for Energy Efficient Ethernet measurements. Order through Crescent Heart Software (http://www.c-h-s.com)
Adapters
®
P6701B
P6703B
Optical/Electrical converter (multi mode). Requires TekVPI to TekProbe BNC adapter (TPA-BNC).
®
Optical/Electrical converter (single mode). Requires TekVPI to TekProbe BNC adapter (TPA-BNC).
2
Notice to EU customers: This product is not updated to comply with the RoHS 2 Directive 2011/65/EU and will not be shipped to the EU. Customers may be able to purchase products from
inventory that were placed on the EU market prior to July 22, 2017 until supplies are depleted. Tektronix is committed to helping you with your solution needs. Please contact your local sales
representative for further assistance or to determine if alternative product(s) are available. Tektronix will continue service to the end of worldwide support life.
www.tek.com/MSO5000 25
Datasheet
Probes
Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please
visit www.tek.com/probes.
®
TPP0500B
500 MHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance
TPP1000
TPP0502
TAP2500
TAP1500
TDP3500
TDP1500
TDP1000
TDP0500
TIVM1
1 GHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance
500 MHz, 2X TekVPI passive voltage probe
2.5 GHz TekVPI active single-ended voltage probe
1.5 GHz TekVPI active single-ended voltage probe
3.5 GHz TekVPI differential voltage probe with ±2 V differential input voltage
1.5 GHz TekVPI differential voltage probe with ±8.5 V differential input voltage
1 GHz TekVPI differential voltage probe with ±42 V differential input voltage
500 MHz TekVPI differential voltage probe with ±42 V differential input voltage
Differential Probe; 1 GHz, Up to 50X, ±50 V, TekVPI, 3 Meter Cable
Differential Probe; 1 GHz, Up to 50X, ±50 V, TekVPI, 10 Meter Cable
Differential Probe; 800 MHz, Up to 2500X, ±2.5 kV, TekVPI, 3 Meter Cable
Differential Probe; 800 MHz, Up to 2500X, ±2.5 kV, TekVPI, 10 Meter Cable
Differential Probe; 500 MHz, Up to 2500X, ±2.5 kV, TekVPI, 3 Meter Cable
Differential Probe; 500 MHz, Up to 2500X, ±2.5 kV, TekVPI, 10 Meter Cable
Differential Probe; 200 MHz, Up to 2500X, ±2.5 kV, TekVPI, 3 Meter Cable
Differential Probe; 200 MHz, Up to 2500X, ±2.5 kV, TekVPI, 10 Meter Cable
20 MHz TekVPI 150 Ampere AC/DC current probe
TIVM1L
TIVH08
TIVH08L
TIVH05
TIVH05L
TIVH02
TIVH02L
TCP0150
TCP0030A
TCP0020
TPP0850
TRCP0300
TRCP0600
TRCP3000
TMDP0200
THDP0200
THDP0100
P5100A
120 MHz TekVPI 30 Ampere AC/DC current probe
50 MHz TekVPI 20 Ampere AC/DC current probe
2.5 kV, 800 MHz TekVPI high-voltage passive probe
30 MHz, 250 mA to 300 A, AC current probe
30 MHz, 500 mA to 600 A, AC current probe
16 MHz, 500 mA to 3000 A, AC current probe
±750 V, 200 MHz high-voltage differential probe
±1.5 kV, 200 MHz high-voltage differential probe
±6 kV, 100 MHz high-voltage differential probe
2.5 kV, 500 MHz, 100X high-voltage passive probe
Recommended software
TekScopeNL-BAS
™
TekScope Anywhere Waveform Analysis and Visualization Node locked license.
™
TekScopeFL-BAS
TekScope Anywhere Waveform Analysis and Visualization floating license.
™
TekScopeNL-DJA
Advanced Jitter Analysis for TekScope Anywhere Node locked license.
™
TekScopeFL-DJA
Advanced Jitter Analysis for TekScope Anywhere floating license.
GRL-USB-PD
USB Power Delivery electrical compliance and decode.
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
26 www.tek.com/MSO5000
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series
www.tek.com/MSO5000 27
Datasheet
ASEAN / Australasia (65) 6356 3900
Belgium 00800 2255 4835*
Austria 00800 2255 4835*
Brazil +55 (11) 3759 7627
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Canada 1 800 833 9200
Central East Europe and the Baltics +41 52 675 3777
Finland +41 52 675 3777
Central Europe & Greece +41 52 675 3777
France 00800 2255 4835*
Denmark +45 80 88 1401
Germany 00800 2255 4835*
Hong Kong 400 820 5835
India 000 800 650 1835
Italy 00800 2255 4835*
Japan 81 (3) 6714 3086
Luxembourg +41 52 675 3777
The Netherlands 00800 2255 4835*
Poland +41 52 675 3777
Russia & CIS +7 (495) 6647564
Sweden 00800 2255 4835*
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Norway 800 16098
Portugal 80 08 12370
South Africa +41 52 675 3777
Switzerland 00800 2255 4835*
USA 1 800 833 9200
Middle East, Asia, and North Africa +41 52 675 3777
People's Republic of China 400 820 5835
Republic of Korea +822 6917 5084, 822 6917 5080
Spain 00800 2255 4835*
Taiwan 886 (2) 2656 6688
United Kingdom & Ireland 00800 2255 4835*
* European toll-free number. If not accessible, call: +41 52 675 3777
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com.
©
Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and
price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
20 Oct 2019 48W-29560-10
www.tek.com/MSO5000
相关型号:
MSO50MRM1E1
Telecom and Datacom Connector, 50 Contact(s), Female, Wire Wrap Terminal, Receptacle
AMPHENOL
MSO50MRM58E1
Telecom and Datacom Connector, 50 Contact(s), Female, Wire Wrap Terminal, Receptacle
AMPHENOL
©2020 ICPDF网 联系我们和版权申明