MSO5034B [TEKTRONIX]

Mixed Signal Oscilloscopes;
MSO5034B
型号: MSO5034B
厂家: TEKTRONIX, INC.    TEKTRONIX, INC.
描述:

Mixed Signal Oscilloscopes

文件: 总28页 (文件大小:2182K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Mixed Signal Oscilloscopes  
MSO5000B, DPO5000B Series Datasheet  
Key analysis features  
®
Wave inspector controls provide easy navigation and automated  
search of waveform data  
Suite of advanced triggers, with standard Visual Trigger and Search  
53 automated measurements, selectable filtering, waveform math and  
FFT analysis  
Waveform histogram, eye diagram, TIE (jitter/timing) measurement and  
analysis  
User-definable math using MATLAB, Visual Studio and Excel  
Optional analysis for memory, advanced jitter, serial data, power and  
Wideband RF  
Designing with today’s faster data rates and tighter timing margins requires  
an oscilloscope with outstanding signal acquisition performance and  
analysis capabilities. Tektronix MSO/DPO5000B Series oscilloscopes  
provide exceptional signal fidelity, with 2 GHz bandwidth and 10 GS/s  
sample rate, along with advanced analysis and math capabilities, on your  
Key protocol features  
Trigger and decode options for mid-speed (100 Mb/s to 1 Gb/s) buses  
Trigger and decode options for low-speed (<10 Mb/s) buses  
®
bench and in your lab. Run Windows -based analysis software right on the  
Compliance test options for USB2.0, Ethernet, USB power, MOST, and  
Automotive Ethernet  
oscilloscope. Point and click Visual Triggers enable you to capture complex  
signals with ease. MSO models include 16 digital timing channels, and all  
models can be equipped to decode common serial protocols, providing a  
comprehensive view of your systems.  
Mask testing on communication, computing and video standards  
Mixed signal design and analysis (MSO Series)  
Key performance specifications  
16 digital channels (user upgradeable)  
2 GHz, 1 GHz, 500 MHz, and 350 MHz bandwidth models  
MagniVu high-speed acquisition provides 60.6 ps timing resolution on  
all digital channels  
Up to 10 GS/s real-time sample rate on one or two channels and up to  
5 GS/s on all four channels  
Automated triggering, decode, and search on parallel buses  
Per-channel threshold settings  
Up to 250 Megapoint record length with MultiView zoom  
®
>250,000 wfms/s maximum waveform capture rate with FastAcq  
acquisition  
FastFrame segmented memory acquisition mode with up to  
290,000 segments and >310,000 waveforms per second capture rate  
Standard 10 MΩ passive voltage probes with less than 4 pF capacitive  
loading and 500 MHz or 1 GHz analog bandwidth  
>11 bits vertical resolution using HiRes sampling  
User-selectable bandwidth limit and DSP filters for lower noise and  
better measurement accuracy  
www.tek.com/MSO5000  
1
Datasheet  
See the performance difference  
With up to 2 GHz analog bandwidth and sampling rates up to 10 GS/s, the  
MSO/DPO5000B series ensures you have the performance you need to  
capture waveforms with the best possible signal fidelity and resolution for  
seeing small waveform details.  
Probing - Up to 1 GHz bandwidth and less than 4 pF capacitive loading provides active  
probe performance and superior performance over passive probes included with other  
mid-range oscilloscopes.  
Fast discovery  
Performance - With up to 2 GHz bandwidth and 10 GS/s sample rate capture  
USB2.0 480 Mb/s differential signals with true fidelity and 100 ps resolution.  
To debug a design problem, first you must know it exists. Every design  
engineer spends time looking for problems in their design, a time-  
consuming and difficult task without the right debug tools. The MSO/  
DPO5000B Series offers the industry's most complete performance to  
capture and isolate events, providing fast insight into the real operation of  
Accurate high-speed probing  
The TPP Series probes, included standard with every MSO/DPO5000B  
Series oscilloscope, provide up to 1 GHz of analog bandwidth, and less  
than 4 pF of capacitive loading. The extremely low capacitive loading  
minimizes adverse effects on your circuits and is more forgiving of longer  
ground leads. And with the probe's wide bandwidth, you can see the high  
frequency components in your signal, which is critical for high-speed  
applications. The TPP Series passive voltage probes offer all the benefits  
of general-purpose probes like high dynamic range, flexible connection  
options, and robust mechanical design, while providing the performance of  
active probes.  
®
your device. Tektronix proprietary FastAcq technology delivers a fast  
waveform capture - greater than 250,000 waveforms per second - that  
enables you to see glitches and other infrequent transients within seconds,  
revealing the true nature of device faults. A digital phosphor display with  
color intensity grading shows the history of a signal's activity by using color  
to identify areas of the signal that occur more frequently, providing a visual  
display of just how often anomalies occur across all channels.  
Discover – fast waveform capture rate - over 250,000 wfm/s - maximizes the probability  
of capturing elusive glitches and other infrequent events.  
2 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
High vertical resolution  
If the measurement requirement is to capture high-amplitude signals while  
seeing smaller signal details, the MSO/DPO5000B provides the acquisition  
flexibility needed to capture the signals of interest while removing the  
effects of unwanted noise. With HiRes acquisition vertical resolution can be  
increased to over 11 bits while reducing signal noise. Signal fidelity can be  
further increased by using channel input filters or applying a wide choice of  
DSP filters.  
Capture - 100 Meg point acquisition with HiRes acquisition - increase vertical resolution  
to >11 bits with dual zoom of waveform details.  
Segmented memory  
For more efficient data capture, partitioning of memory can extend the total  
time captured. FastFrame Segmented Memory mode enables you to  
select up to 290,000 memory segments with a trigger capture rate of over  
310,000 triggers per second. Beyond memory flexibility, segments are time  
stamped and can be viewed individually or as an overlay and analyzed  
using advanced features like protocol decoding. Signals captured with  
Capture - HiRes acquisition - increased vertical resolution to >11 bits while removing  
noise on a 650 V Pk-Pk signal while seeing the smaller details of less than 1 V Pk-Pk  
with or without apply low-pass filtering.  
FastFrame can also be post-processed using waveform averaging or  
envelope mode.  
Long record length  
With up to a 250 M point record length, you can capture many events of  
interest, even thousands of serial packets, in a single acquisition for further  
analysis while maintaining high resolution to zoom in on fine signal details.  
For complex analysis like Time Interval Error (TIE) measurements the  
longer record length ensures you have enough data captured for handling  
clock recovery and creating jitter profiles. Unlike other oscilloscopes in its  
class, the MSO/DPO5000B provides flexible setup of both record length  
and sampling rate to ensure optimum resolution.  
www.tek.com/MSO5000  
3
Datasheet  
Mixed signal design and analysis (MSO  
Series)  
The MSO5000B Series mixed-signal oscilloscopes provide 16 digital  
channels. These channels are tightly integrated into the oscilloscope's user  
interface, simplifying operation and making it possible to solve mixed-signal  
issues easily. MSO functionality can also be added later as a user upgrade.  
Color-coded digital waveform display  
The MSO5000B Series has redefined the way you view digital waveforms.  
One common problem with other mixed-signal oscilloscopes is determining  
if data is a one or a zero when zoomed in far enough that the digital trace  
stays flat all the way across the display. To avoid this problem, the  
MSO5000B Series has color-coded digital traces, displaying ones in green  
and zeros in blue.  
With the color-coded digital waveform display, low values are shown in blue and high  
values are shown in green, enabling instant understanding of the bus value whether  
transitions are visible or not.  
The multiple transition detection hardware of the MSO5000B Series will  
show you when the system detects more than one transition. This indicates  
that more information is available by zooming in or acquiring at faster  
sampling rates. In most cases zooming in will reveal a glitch that was not  
viewable with the previous settings.  
MagniVu high-speed acquisition  
The main digital acquisition mode on the MSO5000B Series will capture up  
to 40 M points at 500 MS/s (2 ns resolution). In addition to the main record,  
the MSO5000B provides an ultra-high-resolution record called MagniVu  
which acquires 10,000 points at up to 16.5 GS/s (60.6 ps resolution). Both  
the main and MagniVu waveforms are acquired on every trigger and either  
can be displayed at any time, running or stopped. MagniVu provides  
significantly finer timing resolution than comparable mixed-signal  
oscilloscopes on the market, instilling confidence when making critical  
timing measurements on digital waveforms.  
FastFrame - User selectable memory segments allow for efficient memory  
management with time stamped capture of SPI bus data along with analysis of serial bus  
decoding on multiple data packets. Frames 1, 2, and 9 are shown here.  
4 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to  
make critical timing measurements on your digital waveforms.  
Visual Trigger- Capture signals on two channels with Visual triggering with multiple  
defined areas and markers showing repeat occurrences.  
Navigation and search  
Versatile trigger and search  
Finding your event of interest in a long waveform record can be time  
consuming without the right search tools. With today's record lengths  
pushing beyond a million data points, locating your event can mean  
scrolling through thousands of screens of signal activity.  
Discovering a device fault is only the first step. Next, you must capture the  
event of interest to identify root cause. The MSO/DPO5000B Series  
provides a complete set of triggers - including runt, glitch, width, timeout,  
transition, pattern, state, setup/hold violation, serial packet, and parallel  
data - to help quickly find your event.  
The MSO/DPO5000B Series offers the industry's most comprehensive  
®
search and waveform navigation with its innovative Wave Inspector  
controls. These controls speed panning and zooming through your record.  
With a unique force-feedback system, you can move from one end of your  
record to the other in just seconds. User marks allow you to mark any  
location that you may want to reference later for further investigation. Or,  
automatically search your record for criteria you define. Wave Inspector will  
instantly search your entire record, including analog, digital, and bus data.  
Along the way it will automatically mark every occurrence of your defined  
event so you can quickly move between events. The standard Advanced  
Search and Mark capability of the MSO/DPO5000B Series can even search  
for up to eight different events simultaneously and stop a live acquisition  
when it finds an event of interest, saving even more time.  
Visual trigger  
Finding the right characteristic of a complex signal can require hours of  
collecting and sorting through thousands of acquisitions for the event of  
interest. Defining a trigger that isolates the desired event and shows data  
only when the event occurs speeds up this process. Visual Trigger and  
Search makes the identification of the desired waveform events quick and  
easy by scanning through all waveform acquisitions and comparing them to  
on-screen areas (geometric shapes). Areas can be created using a variety  
of shapes including triangles, rectangles, hexagons, trapezoids, and user-  
specified shapes to fit the area to the particular trigger behavior desired.  
Set up to eight areas and condition based on Boolean logic conditions.  
www.tek.com/MSO5000  
5
Datasheet  
The standard limit test package enables long-term signal monitoring,  
characterizing signals during design, and production line testing. Limit test  
compares a tested signal to a known good or "golden" version of the same  
signal with user-defined vertical and horizontal tolerances. You can tailor a  
limit test to your specific requirements by defining test duration in a number  
of waveforms, setting a violation threshold that must be met before  
considering a test a failure, counting hits with statistical information, and  
setting actions upon violations, test failure, and test complete.  
Custom analysis  
When signal analysis needs extend beyond the standard or optional  
analysis features, the Microsoft Windows 10 based MSO/DPO5000B series  
has the flexibility to support custom analysis. Apply your custom algorithms  
using custom MATLAB and .NET math plug-ins for analysis functions that  
are integrated in the oscilloscope user interface for more seamless  
operation.  
Search - Results of an advanced search for a runt pulse or a narrow glitch within a long  
waveform record.  
Comprehensive analysis  
Verifying that your prototype's performance matches simulations and meets  
the project's design goals requires analyzing its behavior. Tasks can range  
from simple checks of rise times and pulse widths to sophisticated power  
loss analysis, characterization of system clocks, and investigation of noise  
sources. The MSO/DPO5000B Series offers a comprehensive set of  
integrated analysis tools including waveform- and screen-based cursors,  
53 automated measurements, advanced waveform math including arbitrary  
equation editing, waveform histograms, and FFT analysis.  
Custom analysis - Waterfall display generated from oscilloscope data using MATLAB.  
Jitter analysis  
Every MSO/DPO5000B Series oscilloscope includes the DPOJET  
Essentials jitter and eye pattern analysis software package, extending the  
oscilloscope's measurement capabilities to take measurements over  
contiguous clock and data cycles in a single-shot real-time acquisition. This  
enables measurement of key jitter and timing analysis parameters such as  
Time Interval Error and Phase Noise to help characterize possible system  
timing issues. Analysis tools such as plots for time trends and histograms  
quickly show how timing parameters change over time, and spectrum  
analysis quickly shows the precise frequency and amplitude of jitter and  
modulation sources.  
Analyze - Waveform histogram of the rising and falling edge of a 622 Mb/s signal  
showing the distribution of edge position (jitter) over time. Included are numeric  
measurements made on the waveform histogram data.  
6 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
DDR memory bus analysis (optional)  
The optional DDR memory analysis software package (Option DDRA)  
automatically identifies DDR1, DDR2, LP-DDR, and LP-DDR2 Reads and  
Writes and makes JEDEC conformance measurements with Pass/Fail  
results on all edges in every Read and Write burst, perfect for debugging  
and troubleshooting DDR memory buses. Also provided are common  
measurements of clock, address, and control signals. Used with DPOJET  
(Option DJA), Option DDRA is the fastest way to debug complex memory  
signaling issues.  
Vector signal analysis (optional)  
The optional SignalVu vector signal analysis package (Option SVE) easily  
validates wideband designs and characterizes wideband spectral events.  
By combining the signal analysis engine of Tektronix real-time spectrum  
analyzers with the wide bandwidth acquisition of Tektronix digital  
Jitter analysis - TIE jitter/timing analysis of 622 Mb/s signal  
oscilloscopes, you can now evaluate complex baseband signals directly on  
your oscilloscope. You get the functionality of a vector signal analyzer, a  
spectrum analyzer, and the powerful trigger capabilities of a digital  
oscilloscope - all in a single package. Whether your design validation needs  
include wideband radar, high data-rate satellite links, or frequency hopping  
Extend jitter/timing analysis with the optional DPOJET Advanced software  
package (Option DJA). DPOJET Advanced adds advanced tools such as  
Rj/Dj separation, eye diagram masks, and Pass/Fail limits for conformance  
testing. DPOJET Advanced is also a measurement framework that works  
with standards-specific compliance test packages for applications such as  
DDR memory and USB 2.0.  
communications, SignalVu vector signal analysis software can speed  
your time-to-insight by showing you time-variant behavior of these  
wideband signals.  
Power analysis (optional)  
The optional power analysis software package (Option PWR) enables quick  
and accurate analysis of power quality, switching loss, harmonics, magnetic  
measurements, safe operating area (SOA), modulation, ripple, amplitude  
and timing measurements, and slew rate (di/dt, dv/dt). Automated,  
repeatable power measurements are available with a touch of a button; no  
external PC or complex software setup is required. The package includes a  
report generation tool to automatically create detailed reports to document  
your measurement results.  
Automated power measurements enable quick and accurate analysis of  
common power parameters.  
SignalVu enables detailed analysis in multiple domains.  
Switching Loss measurements.  
www.tek.com/MSO5000  
7
Datasheet  
Event table display  
Protocol triggering and analysis (optional)  
In addition to seeing decoded packet data on the bus waveform itself, you  
can view all captured packets in a tabular view much like you would see in  
a software listing. Packets are time stamped and listed consecutively with  
columns for each component (Address, Data, etc.).  
On a serial bus, a single signal often includes address, control, data, and  
clock information. This can make isolating events of interest difficult. The  
MSO/DPO5000B Series offers a robust set of tools for debugging serial  
buses with automatic trigger and decode on I2C, SPI, CAN, LIN, FlexRay,  
RS-232/422/485/UART, MIL-STD-1553, Ethernet, and USB 2.0, and  
decode for 8b/10b, PCI Express, and MIPI D-PHY DSI-1 and CSI-2 serial  
buses.  
Event table showing decoded SPI serial packet data with bus timing waveform for a long  
acquisition.  
Triggering on a USB full-speed serial bus. A bus waveform provides decoded packet  
content including Start, Sync, PID, Address, End Point, CRC, Data values, and Stop.  
Compliance testing  
Serial bus compliance test (optional)  
Serial triggering  
Software packages for automated compliance test are available for  
Ethernet 10BASE-T, 10BASE-Te, 100BASE-TX, and 1000BASE-T (Option  
ET3), MOST50 and MOST150 electrical (Option MOST), BroadR-Reach/  
100BASE-T1 and 1000BASE-T1 (Option BRR), and USB 2.0 (Option  
USB2) physical-layer devices. These software packages enable you to  
conduct testing using the standard's specified compliance tests.  
Trigger on packet content such as start of packet, specific addresses,  
specific data content, unique identifiers, etc. on popular serial interfaces  
such as I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-  
STD-1553, Ethernet, and USB 2.0.  
Bus display  
Provides a higher-level, combined view of the individual signals (clock,  
data, chip enable, etc.) that make up your bus, making it easy to identify  
where packets begin and end and identifying subpacket components such  
as address, data, identifier, CRC, etc.  
Bus decoding  
Tired of having to visually inspect the waveform to count clocks, determine  
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex  
value? Let the oscilloscope do it for you! Once you've set up a bus, the  
MSO/DPO5000B Series will decode each packet on the bus, and display  
the value in hex, binary, decimal (USB only) or ASCII (USB and  
RS-232/422/485/UART only) in the bus waveform.  
USB 2.0 Compliance Testing.  
8 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Mask testing  
Floating licenses  
The optional mask test (Option MTM) software package is useful for long-  
term signal monitoring, characterizing signals during design, and production  
line testing. The mask test software includes a robust set of masks for  
telecommunications and computer standards for easily checking  
compliance to a standard. Additionally, custom masks can be created and  
used for characterizing signals. With mask testing you can tailor a test to  
your specific requirements by defining test duration in a number of  
waveforms, setting a violation threshold that must be met before  
considering a test a failure, counting hits with statistical information, and  
setting actions upon violations, test failure, and test complete.  
Floating licenses offer an alternative method to manage your Tektronix  
asset. Floating licenses allow license-key enabled options to be easily  
moved among all your MSO/DPO5000, DPO7000, and DPO/DSA/  
MSO70000 Series of Tektronix oscilloscopes. Floating licenses are  
available for many license-key enabled options. To order a floating version  
of an option license add “DPOFL-“ prefix to the option name. (e.g. DPOFL-  
ET3)  
Check www.tek.com for additional information about floating license  
options.  
Easy data storage  
Designed to make your work easier  
Two USB 2.0 host ports on the front panel enable easy transfer of  
screenshots, instrument settings, and waveform data to a USB flash drive.  
Large, high-resolution touchscreen display  
The rear panel contains four additional USB 2.0 host ports and a USB  
device port for controlling the oscilloscope remotely from a PC or for  
connecting USB peripherals. An integrated 10/100/1000BASE-T Ethernet  
port enables easy connection to networks and a Video Out port to drive an  
external monitor or projector. A standard ≥ 480 GB removable solid state  
disk drive makes customizing settings for different users easy and enables  
use in secure environments.  
The MSO/DPO5000B Series features a 10.4 in. (264 mm) XGA color  
display with an integrated touch screen for seeing intricate signal details.  
Connectivity and remote operation  
There are many ways to connect to your MSO/DPO5000B Series  
oscilloscope to conduct extended analysis. The first makes use of the  
Windows Remote Desktop capability – connect directly to your oscilloscope  
and operate the user interface remotely through the built-in Remote  
®
Desktop. A second way to connect is through Tektronix OpenChoice  
software which makes use of the fast embedded bus, transferring  
waveform data directly from acquisition to analysis applications on the  
Windows desktop at much faster speeds than conventional GPIB transfers.  
Industry-standard protocols, such as TekVISA interface and ActiveX  
controls are included for using and enhancing Windows applications for  
data analysis and documentation. IVI-COM instrument drivers are included  
to enable easy communication with the oscilloscope using GPIB, serial  
data, and LAN connections from programs running on the instrument or an  
external PC. Or, use the Software Developer's Kit (SDK) to help create  
custom software to automate multistep processes in waveform collection  
and analysis with Visual BASIC, C, C++, MATLAB, LabVIEW,  
LabWindows/CVI, and other common Application Development  
Environments (ADE).  
High resolution display quality with touch screen, mouse and stylus operation.  
Dedicated front panel controls  
Per-channel vertical controls provide simple and intuitive operation. No  
longer do you need to share one set of vertical controls across all four  
channels.  
www.tek.com/MSO5000  
9
Datasheet  
TekScope Anywhere off-line analysis  
For mixed-domain analysis or greater portability, the MDO4000 and  
MDO3000 series offer:  
TekScope Anywhere brings the power of the oscilloscope analysis  
environment to the PC. Users now have the flexibility to perform analysis  
tasks including timing, eye, and jitter analysis outside the lab. Waveform  
data and setups 1 from Tektronix MDO3000, MDO4000, MSO/DPO5000,  
DPO7000C, or MSO/DPO70000C/D/DX/SX Series oscilloscopes can  
quickly be shared among team members and remote sites, resulting in  
improved efficiency.  
100 MHz to 1 GHz bandwidth  
Up to 5 GS/s sampling  
Up to 20 M point record length  
Serial data trigger and decode  
Built-in 3 GHz or 6 GHz spectrum analyzer (optional)  
2 or 4 analog channels and 16 digital channels (optional)  
Tektronix Mid-range Oscilloscopes  
Need more performance or have other application needs? Consider the  
DPO7000, MDO4000, or MDO3000 series.  
For more performance, the DPO7000C series offers:  
500 MHz to 3.5 GHz bandwidth  
Up to 40 GS/s sampling rate  
Up to 500 M point record length  
1 % accuracy  
More analysis and compliance support for higher data rates  
Microsoft Windows 10  
1
Setups for MSO/DPO5000/B, DPO7000C, MSO/DPO70000C/D/DX/SX models only.  
10 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Specifications  
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.  
Model overview  
MSO5034B  
DPO5034B  
MSO5054B  
DPO5054B  
MSO5104B  
DPO5104B  
MSO5204B  
DPO5204B  
Input Channels  
4
Bandwidth  
350 MHz  
1 ns  
500 MHz  
700 ps  
1 GHz  
350 ps  
2 GHz  
175 ps  
Rise Time (Calculated)  
DC Gain Accuracy  
Bandwidth Limits  
±1.5%, derated at 0.10%/°C above 30 °C  
Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, and 20 MHz  
Effective Number of Bits (Typical)  
6 bits (10 divisionp-p sine wave input at instrument bandwidth, 100 mV/div, 50 Ω Input Impedance, maximum sample rate, 1 k  
point record length)  
Random Noise (RMS, typical, sample mode, full BW, 50 Ω)  
1 mV/div  
2 mV/div  
5 mV/div  
10 mV/div  
20 mV/div  
50 mV/div  
100 mV/div  
1 V/div  
173 μV  
216 μV  
231 μV  
305 μV  
504 μV  
1.15 mV  
2.40 mV  
22.96 mV  
178 μV  
236 μV  
281 μV  
340 μV  
523 μV  
1.17 mV  
2.46 mV  
22.98 mV  
5 GS/s  
68 μV  
70 μV  
128 μV  
214 μV  
315 μV  
547 μV  
1.29 mV  
3.08 mV  
23.15 mV  
5 GS/s  
158 μV  
307 μV  
485 μV  
791 μV  
1.82 mV  
4.75 mV  
29.58 mV  
5 GS/s  
Maximum Sample Rate (All channels) 5 GS/s  
Maximum Sample Rate (1 or  
2 channels)  
5 GS/s  
5 GS/s  
10 GS/s  
10 GS/s  
Maximum Equivalent Time Sampling 400 GS/s  
Rate  
Maximum Record Length with  
Standard Configuration  
25 M  
25 M (4 ch)  
50 M (1 or 2 ch)  
Maximum Record Length with Option 50 M  
5RL  
50 M (4 ch)  
125 M (1 or 2 ch)  
Maximum Record Length with Option 125 M  
10RL  
125 M (4 ch)  
250 M (1 or 2 ch)  
Vertical system analog channels  
Input coupling  
AC, DC  
Input resistance  
Input sensitivity range  
1 MΩ ±1%, 50 Ω ±1%  
1 MΩ: 1 mV/div to 10 V/div  
50 Ω: 1 mV/div to 1 V/div  
Vertical resolution  
8 bits (>11 bits with Hi Res)  
www.tek.com/MSO5000 11  
Datasheet  
Vertical system analog channels  
Maximum input voltage, 1 MΩ  
300 VRMS CAT II, with peaks ≤ ±425 V  
For <100 mV/div derate at 20 dB/decade above 100 kHz to 30 VRMS at 1 MHz, 10 dB/decade above 1 MHz  
For ≥100 mV/div derate at 20 dB/decade above 3 MHz to 30 VRMS at 30 MHz, 10 dB/decade above 30 MHz  
Maximum input voltage, 50 Ω  
Position range  
5 VRMS, with peaks ≤ ±20 V  
±5 divisions  
Delay between any Two Channels ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div)  
(Typical)  
Offset range  
1 mV/div - 50 mV/div  
50.5 mV/div - 99.5 mV/div  
100 mV/div - 500 mV/div  
505 mV/div - 995 mV/div  
1 V/div - 5 V/div  
1 MΩ: ±1 V  
50 Ω: ±1 V  
1 MΩ: ±0.5 V  
50 Ω: ±0.5 V  
1 MΩ: ±10 V  
50 Ω: ±10 V  
1 MΩ: ±5 V  
50 Ω: ±5 V  
1 MΩ: ±100 V  
50 Ω: ±5 V  
5.05 V/div - 10 V/div  
1 MΩ: ±50 V  
50 Ω: NA  
Offset Accuracy  
±(0.005 × |offset – position| + DC Balance)  
Note: Both position and constant offset term must be converted to volts by multiplying by the appropriate volts/div term  
Channel-to-channel isolation (Any ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated BW  
two channels at equal vertical  
scale settings) (typical)  
Vertical system digital channels  
Input Channels  
16 Digital (D15 - D0)  
Per-channel Thresholds  
TTL, ECL, User  
Thresholds  
Threshold Selections  
User-defined Threshold Range  
Threshold Accuracy  
Maximum Input Voltage  
Input Dynamic Range  
±40 V  
±(100 mV + 3% of threshold setting)  
±42 Vpeak  
30 Vp-p ≤200 MHz  
10 Vp-p >200 MHz  
Minimum Voltage Swing  
400 mV  
12 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Vertical system digital channels  
Input Impedance  
100 kΩ  
Probe Loading  
3 pF  
1 bit  
Vertical Resolution  
Horizontal system analog channels  
Maximum Duration at Highest  
Real-Time Sample Rate  
25 ms  
Time Base Range  
12.5 ps/div to 8,000,000 s/div  
2.5 ps/div  
Time resolution (in ET/IT mode)  
Time base delay time range  
–10 divisions to 1000 s  
Channel-to-channel deskew range ±75 ns  
Time base accuracy  
±5 ppm over any ≥1 ms interval  
Horizontal system digital channels  
Maximum Sample Rate (Main)  
Maximum record length (main)  
500 MS/s (2 ns resolution)  
25 M Standard  
Up to 40 M with Record Length options  
Maximum sample rate (MagniVu)  
16.5 GS/s (60.6 ps resolution)  
Maximum record length (MagniVu) 10k points centered around the trigger  
Minimum detectable pulse width 1 ns  
Channel-to-channel skew (typical) 200 ps  
Maximum input toggle rate  
500 MHz at minimum input swing; higher toggle rates can be achieved at higher amplitudes  
Trigger system  
Main trigger modes  
Auto, Normal, and Single  
Trigger coupling  
Trigger holdoff range  
Enhanced triggering  
Trigger jitter  
DC, AC, HF Rej (attenuates >50 kHz), LF Rej (attenuates <50 kHz), Noise Reject (reduces sensitivity)  
250 ns to 8 s  
User-selectable; corrects the difference in timing between the trigger path and the acquired data (not available in FastAcq)  
≤100 fsRMS using Enhanced Trigger  
≤10 psRMS without Enhanced Trigger and in Fast Acq mode  
≤100 psRMS for non-Edge-type trigger modes  
www.tek.com/MSO5000 13  
Datasheet  
Trigger system  
Trigger sensitivity  
Internal DC coupled  
For 1 MΩ: 1 mV/div to 4.98 mV/div: 0.75 div from DC to 50MHz, increasing to 1.3 div at instrument bandwidth ≥5 mV/div: 0.40 div  
from DC to 50 MHz, increasing to 1 div at instrument bandwidth  
For 50 Ω (MSO5204, DPO5204, MSO5104, DPO5104): 0.40 div from DC to 50 MHz, increasing to 1 div at instrument bandwidth  
For 50 Ω (MSO5054, DPO5054, MSO5034, DPO5034): 1 mV/div to 4.98 mV/div: 0.75 div from DC to 50MHz, increasing to 1.3 div  
at instrument bandwidth ≥5 mV/div: 0.40 div from DC to 50 MHz, increasing to 1 div at instrument bandwidth  
External (auxiliary input) 1 MΩ 200 mV from DC to 50 MHz, increasing to 500 mV at 250 MHz  
Trigger level range  
Any channel  
±8 divisions from center of screen  
±8 V  
External (auxiliary input)  
Line  
Fixed at about 50% of line voltage  
Trigger modes  
Edge  
Positive, negative, or either slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and  
noise reject  
Glitch  
Trigger on or reject glitches of positive, negative, or either polarity. Programmable glitch width is 4 ns minimum to 8 s maximum  
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again  
Trigger on width of positive or negative pulse either within or outside selectable limits (4 ns to 8 s)  
Runt  
Width  
Timeout  
Transition  
Setup/Hold  
Pattern  
Trigger on an event which remains high, low, or either, for a specified time period (4 ns to 8 s)  
Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either  
Trigger on violations of both setup time and hold time between clock and data present on any two input channels  
Trigger when any logical pattern of signals goes false or stays true for specified period of time (4 ns to 1 s). Pattern (AND, OR,  
NAND, NOR) specified for all analog and digital input channels defined as High, Low, or Don't Care  
Parallel Bus  
State  
Trigger on specified data value on defined parallel bus  
Any logical pattern of analog channels and digital channels (MSO models) clocked by edge on another channel. Trigger on rising  
or falling clock edge  
Video  
Trigger on all lines, specific line number, odd, even, or all fields on NTSC, PAL, SECAM, and HDTV 480p/60, 576p/50, 875i/60,  
720p/30, 720p/50, 720p/60, 1080/24sF, 1080i/50, 1080p/25, 1080i/60, 1080p/24, 1080p/25, 1080p/50, 1080p/60, Bi-level, Tri-level  
Trigger Sequences  
Main, Delayed by Time, Delayed by Events. All sequences can include separate horizontal delay after the trigger event to position  
the acquisition window in time  
A/B Sequence Event Trigger  
Types  
Edge  
Trigger Delay by Time  
Trigger Delay by Events  
Visual Trigger  
4 ns to 8 s  
1 to 4,000,000 events  
Trigger on up to 8 user-specified areas, including rectangle, triangle, trapezoid, hexagon, and user-specified shapes on any of the  
analog channels  
I2C (Optional)  
Provided as part of Opt. SR-EMBD. Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address  
and Data on I2C buses up to 10 Mb/s  
SPI (Optional)  
CAN (Optional)  
Provided as part of Opt. SR-EMBD. Trigger on Slave Select, Idle Time, or Data (1-16 words) on SPI buses up to 10 Mb/s  
Provided as part of Opt. SR-AUTO. Trigger on Start of Frame, Type of Frame (Data, Remote, Error, or Overload), Identifier, Data,  
Identifier and Data, EOF, Missing Ack, Bit Stuff Error, and CRC Error on CAN buses up to 1 Mb/s  
LIN (Optional)  
Provided as part of Opt. SR-AUTO. Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, and Error  
on LIN buses up to 1 Mb/s  
FlexRay (Optional)  
Provided as part of Opt. SR-AUTO. Trigger on Indicator Bits (Normal, Payload, Null, Sync, Startup), Cycle Count, Header Fields  
(Indicator Bits, Identifier, Payload Length, Header CRC, and Cycle Count), Identifier, Data, Identifier and Data, End Of Frame, and  
Error on FlexRay buses up to 10 Mb/s  
MIL-STD-1553 (Optional)  
Provided as part of Opt. SR-AERO. Trigger on Sync, Command Word, Status Word, Data Word, Idle Time, and Error on MIL-  
STD-1553 buses up to 1 Mb/s  
14 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Trigger system  
Ethernet (Optional)  
Provided as part of Opt. SR-ENET. Trigger on Start of Packet, MAC Address, MAC Q-tag, MAC Length/Type, MAC Data, IP  
Header, TCP Header,  
TCP/IPV4 Data, End of Packet, and FCS(CRC) Error on 10BASE-T and 100BASE-TX buses.  
RS-232/422/485/UART  
(Optional)  
Provided as part of Opt. SR-COMP. Trigger on Start Bit, End of Packet, Data, and Parity Error up to 10 Mb/s  
USB 2.0 Low Speed:  
(Optional)  
Provided as part of Opt. SR-USB.  
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special  
Packet, Error.  
Token Packet Trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any, OUT, IN, and SETUP token  
types. Address can be further specified to trigger on ≤, <, =, >, ≥, != a particular value, or inside or outside a range. Frame number  
can be specified for SOF token using Binary, Hex, Unsigned Decimal, and Don't Care digits.  
Data Packet Trigger – Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, != a particular data  
value, or inside or outside a range.  
Handshake Packet Trigger – Any handshake type, ACK, NAK, STALL.  
Special Packet Trigger – Any special type, Reserved.  
Error Trigger – PID Check, CRC5 or CRC16, Bit Stuffing.  
USB 2.0 Full Speed: (Optional) Provided as part of Opt. SR-USB.  
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special  
Packet, Error.  
Token Packet Trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any, OUT, IN, and SETUP token  
types. Address can be further specified to trigger on ≤, <, =, >, ≥, != a particular value, or inside or outside a range. Frame number  
can be specified for SOF token using Binary, Hex, Unsigned Decimal, and Don't Care digits.  
Data Packet Trigger – Any data type, DATA0, DATA1; Data can be further specified to trigger on ≤, <, =, >, ≥, != a particular data  
value, or inside or outside a range.  
Handshake Packet Trigger – Any handshake type, ACK, NAK, STALL.  
Special Packet Trigger – Any special type, PRE, Reserved.  
Error Trigger – PID Check, CRC5 or CRC16, Bit Stuffing.  
Provided as part of Opt. SR-USB.  
USB 2.0 High Speed:  
(Optional)  
Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special  
Packet, Error.  
Token Packet Trigger – Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any, OUT, IN, and SETUP token  
types. Address can be further specified to trigger on ≤, <, =, >, ≥, != a particular value, or inside or outside a range. Frame number  
can be specified for SOF token using Binary, Hex, Unsigned Decimal, and Don't Care digits.  
Data Packet Trigger – Any data type, DATA0, DATA1, DATA2, DATAM; Data can be further specified to trigger on ≤, <, =, >, ≥, !=  
a particular data value, or inside or outside a range.  
Handshake Packet Trigger – Any handshake type, ACK, NAK, STALL, NYET.  
Special Packet Trigger – Any special type, ERR, SPLIT, PING, Reserved. SPLIT packet components that can be specified include:  
Hub Address  
Start/Complete – Don't Care, Start (SSPLIT), Complete (CSPLIT) Port Address  
Start and End bits – Don't Care, Control/Bulk/Interrupt (Full-speed Device, Low-speed Device), Isochronous (Data is Middle, Data  
is End, Data is Start, Data is All)  
Endpoint Type – Don't Care, Control, Isochronous, Bulk, Interrupt  
Error Trigger – PID Check, CRC5, CRC16, Any.  
Note: USB 2.0 High-speed triggering, decoding, and search only available on 1 GHz and 2 GHz models.  
www.tek.com/MSO5000 15  
Datasheet  
Acquisition system  
Acquisition modes  
Sample  
Acquire sampled values  
Peak detect  
Captures narrow glitches as narrow as 100 ps (2 GHz and 1 GHz models) or 200 ps (500 MHz and 350 MHz models) at all real-  
time sampling rates  
Averaging  
Envelope  
Hi-Res  
From 2 to 10,000 waveforms included in average  
Min-Max envelope reflecting Peak Detect data over multiple acquisitions  
Real-time boxcar averaging reduces random noise and increases resolution  
Roll mode  
Scrolls sequential waveform points across the display in a right-to-left rolling motion at sweep speeds slower than 50 ms/div. Up to  
20 MS/s with a maximum record length of 10 M  
®
FastAcq  
FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events  
Maximum FastAcq waveform >250,000 wfms/s on all 4 channels simultaneously  
capture rate  
Waveform database  
Accumulate waveform database providing three-dimensional array of amplitude, time, and counts  
FastFrame  
Acquisition memory divided into segments; maximum trigger rate >310,000 waveforms per second. Time of arrival recorded with  
each event. Frame finder tool helps to visually identify transients  
Automated Search and Mark  
Automatically mark events and document waveforms. Search positive/negative slopes or both, glitches, runts, pulse widths,  
transition rate, setup and hold, timeout, windows, or find any logic or state pattern, up to 8 different event types on any of the  
4 analog channels. Search DDR Read or Write bursts with Opt. DDRA. Event table summarizes all found events. All events are  
time stamped in reference to trigger position. Stop acquisitions when an event is found  
Waveform analysis  
Waveform measurements  
Cursors  
Waveform and Screen  
Automatic measurements  
53, of which 8 can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time, Fall  
Time, Positive Duty Cycle, Negative Duty Cycle, Positive Width, Negative Width, Burst Width, Phase, Positive Overshoot, Negative  
Overshoot, Peak-to-Peak, Amplitude, High, Low, Maximum, Minimum, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area  
Eye-pattern measurements  
Extinction Ratio (absolute, %, dB), Eye Height, Eye Width, Eye Top, Eye Base, Crossing %, Jitter (p-p, RMS, 6sigma), Noise (p-p,  
RMS), Signal/Noise Ratio, Cycle Distortion, Q-Factor  
Measurement statistics  
Reference levels  
Gating  
Mean, Minimum, Maximum, Standard Deviation  
User-definable reference levels for automatic measurements can be specified in either percent or units  
Isolate the specific occurrence within an acquisition to take measurements on, using either screen or waveform cursors  
Waveform histogram  
A waveform histogram provides an array of data values representing the total number of hits inside a user-defined region of the  
display. A waveform histogram is both a visual graph of the hit distribution and a numeric array of values that can be measured.  
Sources – Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math 1, Math 2, Math 3, Math 4  
Types – Vertical, Horizontal  
Waveform histogram  
measurements  
Waveform Count, Hits in Box, Peak Hits, Median, Maximum, Minimum, Peak-to-Peak, Mean (μ), Standard Deviation (sigma),  
μ +1sigma, μ +2sigma, μ +3sigma  
Waveform processing/math  
Arithmetic  
Add, Subtract, Multiply, Divide waveforms and scalars  
Algebraic expressions  
Define extensive algebraic expressions including waveforms, scalars, user-adjustable variables, and results of parametric  
measurements. Perform math on math using complex equations. e.g. (Integral (CH1 – Mean(CH1)) × 1.414 × VAR1)  
Math functions  
Relational  
Average, Invert, Integrate, Differentiate, Square Root, Exponential, Log10, Log e, Abs, Ceiling, Floor, Min, Max, Sin, Cos, Tan,  
ASin, ACos, ATan, Sinh, Cosh, Tanh  
Boolean result of comparison >, <, ≥, ≤, ==, !=  
Frequency domain functions Spectral Magnitude and Phase, Real and Imaginary Spectra  
(FFT)  
FFT vertical units  
Magnitude: Linear, dB, dBm  
Phase: Degrees, radians, group delay  
16 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Waveform analysis  
FFT window functions  
Waveform definition  
Filtering functions  
Custom math functions  
Mask function  
Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential  
As an arbitrary math expression  
User-definable filters. Users specify a filter containing the coefficients of the filter. Filter files provided  
Custom MATLAB and .NET plug-ins can be included in the math waveform definition  
A function that generates a waveform database pixmap from a sample waveform. Sample count can be defined  
Software  
IVI driver  
Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI,  
Microsoft .NET and MATLAB. IVI-COM standard  
LXI Class C web interface  
Connect to the MSO/DPO5000B Series through a standard Web browser by simply entering the oscilloscope's IP address in the  
address bar of the browser. The web interface enables viewing of instrument status and configuration, as well as status and  
modification of network settings. All web interaction conforms to LXI Class C specification  
Display system  
Display type  
10.4 in. (264 mm) liquid-crystal active-matrix color display with touch screen  
1024 horizontal × 768 vertical pixels (XGA)  
Display resolution  
Waveform styles  
Color palettes  
Vectors, dots, variable persistence, infinite persistence  
Normal, green, gray, temperature, spectral, and user defined  
YT, XY  
Display format  
Computer system  
Operating system  
Microsoft Windows 10 Enterprise IoT Edition  
Intel i5-4400E 2.7 GHz processor  
CPU  
PC system memory  
Solid state disk drive  
Mouse  
≥4 GB  
Removable solid state disk drive, 512 GB  
Optical wheel mouse, USB interface  
Order 119-7083-xx for small keyboard; USB interface and hub  
Keyboard  
www.tek.com/MSO5000 17  
Datasheet  
Input output ports  
USB 2.0 High-speed host ports  
Supports USB mass storage devices, printers, keyboard, and mouse. Two ports on front and four ports on rear of instrument. Can  
be disabled individually  
USB 1.1 Full-speed device port  
LAN port  
Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488 adapter)  
RJ-45 connector, supports 10/100/1000BASE-T  
Video out port  
DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector. Support for extended  
desktop and clone mode  
Audio ports  
Miniature phono jacks  
Keyboard port  
Mouse port  
PS/2 compatible  
PS/2 compatible  
Auxiliary input  
Front-panel BNC connector. Input impedance 1 MΩ. Max input 300 VRMS with peaks ≤ ±425 V  
Auxiliary out (software switchable) Trigger Out: A TTL compatible pulse when the oscilloscope triggers  
Time Base Reference Out: A TTL compatible output of internal 10 MHz reference oscillator  
External reference in  
Time base system can phase lock to an external 10 MHz reference (10 MHz ±1%)  
Probe compensator output  
Front-panel pins  
Amplitude: 2.5 V  
Frequency: 1 kHz  
LAN eXtensions for  
Instrumentation (LXI)  
Class: LXI Class C Version: 1.3  
®
Optional TekVPI external power  
Required when total oscilloscope probe power usage exceeds 15 W.  
supply  
Output Voltage  
Output Current  
Power Consumption  
12 V  
5 A  
50 W  
Power source  
Power source voltage  
100 to 240 V ±10%  
Power source frequency  
Power consumption  
45 Hz to 66 Hz (85 to 264 V)  
360 Hz to 440 Hz (100 to 132 V)  
275 W maximum  
18 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Physical characteristics  
Dimensions  
mm  
233  
439  
206  
in.  
Height  
Width  
Depth  
9.16  
17.29  
8.12  
Weight  
kg  
lb.  
Net  
6.7  
12.5  
14.9  
27.5  
Shipping  
Rackmount configuration  
Cooling clearance  
5U  
in.  
0
mm  
0
Top  
Bottom  
Left Side  
Right Side  
Front  
0
0
2
51  
0
0
0
0
Rear  
2
51  
EMC environmental and safety  
Temperature  
Operating  
0 °C to +50 °C  
–20 °C to +60 °C  
Nonoperating  
Humidity  
Operating  
8% to 90% relative humidity with a maximum wet-bulb temperature of 29 °C at or below +50 °C (upper limit de-rates to 20.6%  
relative humidity at +50 °C). Noncondensing  
Nonoperating  
5% to 98% relative humidity with a maximum wet-bulb temperature of 40 °C at or below +60 °C (upper limit de-rates to 29.8%  
relative humidity at +60 °C). Noncondensing  
Altitude  
Operating  
3,000 m (9,843 ft.)  
9,144 m (30,000 ft.)  
Nonoperating  
Regulatory  
Electromagnetic compatibility 2004/108/EC  
Certifications UL61010-1; CSA61010-1, EN61010-1; IEC 61010-1  
www.tek.com/MSO5000 19  
Datasheet  
Ordering information  
DPO5000B models  
DPO5034B  
DPO5054B  
DPO5104B  
DPO5204B  
350 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscope  
500 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscope  
1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscope  
2 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscope  
MSO5000B models  
MSO5034B  
350 MHz, 5 GS/s, 25 M record length, 4+16 channel mixed signal oscilloscope  
500 MHz, 5 GS/s, 25 M record length, 4+16 channel mixed signal oscilloscope  
1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4+16 channel mixed signal oscilloscope  
2 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4+16 channel mixed signal oscilloscope  
MSO5054B  
MSO5104B  
MSO5204B  
Standard accessories  
TPP0500B  
One passive voltage probe per analog channel (500 MHz, 10X, 3.9 pF) for 500 MHz and 350 MHz models  
TPP1000  
One passive voltage probe per analog channel (1 GHz, 10X, 3.9 pF) for 2 GHz and 1 GHz models  
200-5130-xx  
Front cover  
119-6107-xx  
Touch-screen stylus  
071-298x-xx  
User Manual (please specify language when ordering)  
Advanced Search and Mark, DPOJET Essentials, Visual Trigger and Search, and Limit Test all included standard  
Accessory pouch  
Mouse  
Calibration Certificate documenting measurement traceability to National Metrology Institute(s), Z 540-1 Compliance and ISO9001  
Power Cord (please specify power plug option when ordering)  
One-year warranty  
P6616  
16-channel logic probe for MSO Models  
Logic probe accessory kit for MSO Models  
020-2662-xx  
Options  
Record length options  
Option  
MSO5034B  
DPO5034B  
MSO5054B  
DPO5054B  
MSO5104B  
DPO5104B  
MSO5204B  
DPO5204B  
Opt. 5RL  
50 M/Ch  
125 M max, 50 M/Ch  
250 M max, 125 M/Ch  
Opt. 10RL  
125 M/Ch  
20 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Advanced analysis options  
Option  
Description  
Opt. BRR  
BroadR-Reach/100BASE-T1 and 1000BASE-T1 Compliance Testing (Requires TF-GBE-BTP and TF-BRR-CFD Test Fixtures) (Available on  
1 GHz and 2 GHz models only.)  
Opt. DDRA  
Opt. DJA  
DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only.)  
Jitter and Eye Analysis Tools – Advanced (DPOJET)  
Opt. DJAN  
Opt. CMENET3  
Opt. ET3  
DPOJET Noise, jitter, and eye analysis tools (Requires Opt. DJA)  
TekExpress Ethernet Automated 10/100/1000 BASE-T Solution (or purchase Opt. CMENET3A if you already have Opt. ET3)  
Ethernet compliance test (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)  
MOST Essentials – Electrical compliance and debug test solution for MOST50 and MOST150 (Requires Opt. DJA)  
Opt. MOST  
Opt. MTM  
Mask testing  
– ITU-T (64 Kb/s to 155 Mb/s)  
– ANSI T1.102 (1.544 Mb/s to 155 Mb/s)  
– Ethernet IEEE 802.3, ANSI X3.263 (125 Mb/s to  
1.25 Gb/s)  
– SONET/SDH (51.84 Mb/s to 622 Mb/s)  
– Fibre Channel (133 Mb/s to 2.125 Gb/s)  
– Fibre Channel Electrical (133 Mb/s to 1.06 Gb/s)  
– USB (12 Mb/s to 480 Mb/s)  
– IEEE 1394b (491.5 Mb/s to 1.966 Gb/s)  
– Rapid I/O Serial (up to 1.25 Gb/s)  
– Rapid I/O LP-LVDS (500 Mb/s to 1 Gb/s)  
– OIF Standards (1.244 Gb/s)  
– CPRI, V4.0 (1.228 Gb/s)  
– Video (143.18 Mb/s to 360 Mb/s)  
Opt. PWR  
Power measurement and analysis  
Opt. SR-AERO  
Aerospace serial triggering and analysis (MIL-STD-1553).  
Enables triggering on packet-level information on MIL-STD-1553 buses and analytical tools such as bus views, packet decoding, search tools,  
and packet decode tables with time stamp information.  
Signal Inputs – Any Ch1 - Ch4  
Recommended probing – Differential  
Opt. SR-AUTO  
Opt. SR-COMP  
Opt. SR-DPHY  
Opt. SR-EMBD  
Opt. SR-ENET  
Automotive serial triggering and analysis (CAN/LIN/FlexRay).  
Enables triggering on packet-level information on CAN, LIN, and FlexRay buses and analytical tools such as digital views of the signal, bus views,  
packet decoding, search tools, and packet decode tables with time stamp information.  
Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models)  
Recommended probing – LIN: single-ended; CAN/FlexRay: differential  
Computer serial triggering and analysis (RS-232/422/485/UART)  
Enables triggering on packet-level information on RS-232/422/485/UART buses and analytical tools such as digital views of the signal, bus views,  
packet decoding, search tools, and packet decode tables with time stamp information.  
Signal Inputs – Any Ch1 - Ch4 (and any D0 - D15 on MSO models)  
Recommended probing – RS-232/UART: single ended; RS-422/485: differential  
®
MIPI D-PHY serial analysis.  
Enables analysis of MIPI DSI-1 and CSI-2 buses with analytical tools such as digital views of the signal, bus views, packet decoding, search  
tools, and packet decode tables with time stamp information.  
Signal Inputs – Any Ch1 - Ch4  
Recommended probing – Differential  
Embedded serial triggering and analysis (I2C, SPI)  
Enables triggering on packet-level information on I2C and 2-wire and 3-wire SPI buses and analytical tools such as digital views of the signal, bus  
views, packet decoding, search tools, and packet decode tables with time stamp information.  
Signal Inputs – I2C: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); SPI: Any Ch1 - Ch4 (and any D0 - D15 on MSO models)  
Recommended probing – I2C, SPI: single ended  
Ethernet serial triggering and analysis (10BASE-T, 100BASE-TX)  
Enables triggering on packet-level information on Ethernet buses as well as analytical tools such as bus views, packet decoding, search tools,  
and packet decode tables with time stamp information.  
Signal Inputs – Any Ch1 - Ch4.  
Recommended probing – Differential  
www.tek.com/MSO5000 21  
Datasheet  
Option  
Description  
Opt. SR-USB  
USB 2.0 serial triggering and analysis (LS, FS, HS)  
Enables triggering on packet-level content for low-speed, full-speed, and high-speed USB serial buses. Also enables analytical tools such as bus  
views, packet decoding, search tools, and packet decode tables with time stamp information for low-speed, full-speed, and high-speed USB serial  
buses.  
Signal Inputs – Low-speed and Full-speed: Any Ch1 - Ch4 (and any D0 - D15 on MSO models) for single ended, Any Ch1 - Ch4 for differential;  
High-speed: Any Ch1 - Ch4  
Recommended probing – Low-speed and Full-speed: Single ended or differential; High-speed: Differential (USB high-speed supported only on  
1 GHz and 2 GHz models.)  
Opt. SSD  
Opt. SVA  
Opt. SVE  
Opt. SVM  
Opt. SVP  
Opt. SVT  
Additional customer-installable removable Solid State Drive with Microsoft Windows 10 OS, TekScope, and applications software installed  
AM/FM/PM Audio Signal Analysis (Requires Opt. SVE)  
®
SignalVu Essentials – Vector signal analysis software  
®
SignalVu General Purpose Modulation Analysis (Requires Opt. SVE)  
®
SignalVu Advanced Signal Analysis (including pulse measurements) (Requires Opt. SVE)  
®
SignalVu Frequency and Phase Settling Time Measurements (Requires Opt. SVE)  
®
Opt. SV26  
Opt. USB2  
Opt. USBPWR  
SignalVu APCO P25 measurements (Requires Opt. SVE)  
USB 2.0 Automated Compliance Test Application (Requires TDSUSBF USB Test Fixture. 2 GHz bandwidth required for high-speed USB)  
Automated compliance test solution for USB power adapters  
Bundle options  
These bundled items must be purchased at the same time as the instrument purchase.  
Option  
Description  
Opt. PS2  
Opt. PS3  
Power Solution Bundle: DPOPWR, THDP0200, TCP0030A, 067-1686-xx (Deskew fixture)  
Power Solution Bundle: DPOPWR, TMDP0200, TCP0020, 067-1686-xx (Deskew fixture)  
Floating options  
Floating licenses offer an alternative method to manage your Tektronix asset. Floating licenses allow license-key enabled options to be easily moved among all your MSO/  
DPO5000, DPO7000, and DPO/DSA/MSO70000 Series Tektronix oscilloscopes. Floating licenses are available for the following license-key enabled options.  
Check http://www.tek.com/products/oscilloscopes/floatinglicenses for additional information about floating license options.  
Option  
Description  
DPOFL-BRR  
BroadR-Reach/100BASE-T1 and 1000BASE-T1 Compliance Testing (Requires TF-GBE-BTP and TF-BRR-CFD Test Fixtures)  
(Available on 1 GHz and 2 GHz models only)  
DPOFL-DDRA  
DPOFL-DJA  
DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only)  
Jitter and Eye Analysis Tools – Advanced (DPOJET)  
DPOFL-DJAN  
DPOFL-CMENET3  
DPOJET Noise, jitter, and eye analysis tools (Requires Opt. DJA)  
TekExpress Ethernet Automated 10/100/1000 BASE-T Solution (or purchase DPOFL-CMENET3A if you already have DPOFL-  
CMENET3A)  
DPOFL-ET3  
Ethernet compliance testing (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet test fixture.)  
MOST Essentials – Electrical compliance and debug test solution (MOST50, MOST150) (Requires Opt. DJA)  
Mask testing  
DPOFL-MOST  
DPOFL-MTM  
DPOFL-PWR  
Power measurement and analysis  
DPOFL-SR-AERO  
DPOFL-SR-AUTO  
DPOFL-SR-COMP  
DPOFL-SR-DPHY  
DPOFL-SR-EMBD  
Aerospace serial triggering and analysis (MIL-STD-1553)  
Automotive serial triggering and analysis (CAN/LIN/FlexRay)  
Computer serial triggering and analysis (RS-232/422/485/UART)  
®
MIPI D-PHY serial analysis  
Embedded serial triggering and analysis (I2C, SPI)  
22 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
Option  
Description  
DPOFL-SR-ENET  
DPOFL-SR-PCIE  
DPOFL-SR-USB  
DPOFL-SR-810B  
DPOFL-SVA  
Ethernet serial triggering and analysis (10BASE-T and 100BASE-TX)  
PCI Express serial analysis (Available on ≥1 GHz models only)  
USB 2.0 serial triggering and analysis (LS, FS, HS)  
8b/10b serial analysis  
®
SignalVu AM/FM/PM/Direct Audio measurements (Requires Opt. SVE)  
®
DPOFL-SVE  
SignalVu Essentials – Vector signal analysis software  
®
DPOFL-SVM  
DPOFL-SVP  
SignalVu General purpose modulation analysis (Requires Opt. SVE)  
®
SignalVu Pulse – Advanced signal analysis (Requires Opt. SVE)  
®
DPOFL-SVT  
SignalVu Settling time measurements (Requires Opt. SVE)  
®
DPOFL-SV26  
DPOFL-USB2  
SignalVu APCO P25 measurements (Requires Opt. SVE)  
USB 2.0 Automated Compliance Test Application (Requires TDSUSBF USB Test Fixture. 2 GHz bandwidth required for high-  
speed USB)  
DPOFL-USBPWR  
Automated compliance test solution for USB power adapters  
Power plug options  
Opt. A0  
Opt. A1  
Opt. A2  
Opt. A3  
Opt. A5  
Opt. A6  
Opt. A10  
Opt. A11  
Opt. A12  
Opt. A99  
North America power plug (115 V, 60 Hz)  
Universal Euro power plug (220 V, 50 Hz)  
United Kingdom power plug (240 V, 50 Hz)  
Australia power plug (240 V, 50 Hz)  
Switzerland power plug (220 V, 50 Hz)  
Japan power plug (100 V, 50/60 Hz)  
China power plug (50 Hz)  
India power plug (50 Hz)  
Brazil power plug (60 Hz)  
No power cord  
User manual options  
Opt. L0  
Opt. L1  
Opt. L3  
Opt. L5  
Opt. L7  
Opt. L8  
Opt. L9  
Opt. L10  
English manual  
French manual  
German manual  
Japanese manual  
Simplified Chinese manual  
Traditional Chinese manual  
Korean manual  
Russian manual  
www.tek.com/MSO5000 23  
Datasheet  
Service options  
Opt. C3  
Calibration Service 3 Years  
Opt. C5  
Calibration Service 5 Years  
Opt. D1  
Calibration Data Report  
Opt. D3  
Calibration Data Report 3 Years (with Opt. C3)  
Calibration Data Report 5 Years (with Opt. C5)  
Repair Service 3 Years (including warranty)  
Repair Service 5 Years (including warranty)  
Opt. D5  
Opt. R3  
Opt. R5  
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty  
and calibration terms.  
Upgrade options  
To upgrade your MSO/DPO5000B Series oscilloscope, order DPO-UP and an option listed below. For example, to add option DDRA, DDR Memory Technology Analysis  
Package, order DPO-UP DDRA.  
To upgrade record length:  
RL25E  
From standard 25 M/channel configuration to Opt. 5RL configuration  
From standard 25 M/channel configuration to Opt. 10RL configuration  
From Opt. 5RL configuration to Opt. 10RL configuration  
RL210E  
RL510E  
To add a solid state hard disk  
drive:  
SSDE  
Add an additional customer-installable removable Solid State Drive assembly with Microsoft Windows 7 OS, TekScope, and  
applications software installed  
DPO5SSD-W10  
Add an additional customer-installable removable Solid State Drive assembly with Microsoft Windows 10 OS, TekScope, and  
applications software installed. Note: order DPO5SSD-W10, do not order DPO-UP for this SSD.  
To upgrade MSO/DPO5000B Series  
with:  
BRR  
Add Opt. BRR - BroadR-Reach/100BASE-T1 and 1000BASE-T1 Compliance Testing (Requires TF-GBE-BTP and TF-BRR-CFD  
Test Fixtures) (Available on 1 GHz and 2 GHz models only)  
DDRA  
Add Opt. DDRA (Requires Opt. DJA.) (Available on 1 GHz and 2 GHz models only)  
Add Opt. DJA – Jitter and Eye Analysis Tools - Advanced (DPOJET)  
DJAE  
DJAN  
Add Opt. DJAN - DPOJET Noise, jitter, and eye analysis tools (Requires Opt. DJA)  
CMENET3  
Add Opt. CMENET3 - TekExpress Ethernet Automated 10/100/1000 BASE-T Solution (or purchase CMENET3A if you already  
have Opt. ET3)  
ET3  
Add Opt. ET3 – Ethernet Compliance Testing (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)  
Add Opt. MOST – MOST Essentials - Electrical Compliance and Debug Test Solution (MOST50, MOST150) (Requires Opt. DJA)  
Add Opt. MTM – Mask Testing  
MOST  
MTM  
PWR  
Add Opt. PWR – Power Measurement and Analysis  
SR-AERO  
SR-AUTO  
SR-COMP  
SR-DPHY  
SR-EMBD  
SR-ENET  
SR-PCIE  
SR-USB  
Add Opt. SR-AERO – Aerospace Serial Triggering and Analysis (MIL-STD-1553)  
Add Opt. SR-AUTO – Automotive Serial Triggering and Analysis (CAN/LIN/FlexRay)  
Add Opt. SR-COMP – Computer Serial Triggering and Analysis (RS-232/422/485/UART)  
Add Opt. SR-DPHY – MIPI D-PHY Serial Analysis (DSI-1, CSI-2)  
Add Opt. SR-EMBD – Embedded Serial Triggering and Analysis (I2C, SPI)  
Add Opt. SR-ENET – Ethernet Serial Triggering and Analysis (10BASE-T and 100BASE-TX)  
Add PCI Express Serial Analysis (Available on ≥1 GHz models only.)  
Add Opt. SR-USB – USB 2.0 Serial Triggering and Analysis (LS, FS, HS)  
24 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
SR-810B  
SVA  
Add 8b/10b Serial Analysis  
Add SignalVu AM/FM/Direct Audio Measurements (Requires Opt. SVE)  
Add Opt. SVE – SignalVu Essentials - Vector Signal Analysis Software  
Add SignalVu General-purpose Modulation Analysis (Requires Opt. SVE)  
Add SignalVu Pulse - Advanced Signal Analysis (Requires Opt. SVE)  
Add SignalVu Settling Time Measurements - Frequency and Phase (Requires Opt. SVE)  
SVEE  
SVM  
SVP  
SVT  
®
SV26  
USB2  
Add Opt. SV26 - SignalVu APCO P25 measurements (Requires Opt. SVE)  
Add Opt. USB2 – USB 2.0 Automated Compliance Test Application (Requires TDSUSBF USB Test Fixture) (2 GHz bandwidth  
required for high-speed USB)  
USBPWR  
Add Opt. USBPWR - Automated compliance test solution for USB power adapters  
Add 16 digital channels to a DPO5000B  
To upgrade DPO5000B Series to  
MSO:  
MSOE  
Recommended accessories  
Accessories  
077-0076-xx  
077-0010-xx  
077-0063-xx  
TPA-BNC  
Service manual (PDF only)  
Programmer manual (PDF only)  
Performance verification and specifications manual (PDF only)  
TekVPI-to-TekProbe BNC adapter  
Deskew Pulse Generator  
TEK-DPG  
TEK-USB-488  
HCTEK54  
GPIB-to-USB adapter  
Hard transit case  
RMD5000  
Rackmount kit  
119-7275-xx  
119-8726-xx  
Mini multimedia keyboard  
TekVPI external power supply – Required when probe power usage exceeds 15 W. Power cord not included. Specify power cord  
when ordering.  
020-3071-xx  
NEX-HD2HEADER2  
DPO Demo 3 board with dual-A to single-B USB cable  
Mictor connector to square pin adapter  
Test fixtures  
067-1686-xx  
TDSUSBF  
Probe Calibration / Power Deskew test fixture  
Test fixture for use with Opt. USB2  
TF-BRR-CFD  
TF-GBE-BTP  
TF-GBE-ATP  
TF-GBE-EE  
Automotive Ethernet Compliance Clock Frequency Divider fixture  
Basic test package for 10/100/1000BASE-T Ethernet tests  
Advanced test package for 10/100/1000BASE-T Ethernet (includes 1000BASE-T jitter test channel cable)  
Additional test fixture for Energy Efficient Ethernet measurements. Order through Crescent Heart Software (http://www.c-h-s.com)  
Adapters  
®
P6701B  
P6703B  
Optical/Electrical converter (multi mode). Requires TekVPI to TekProbe BNC adapter (TPA-BNC).  
®
Optical/Electrical converter (single mode). Requires TekVPI to TekProbe BNC adapter (TPA-BNC).  
2
Notice to EU customers: This product is not updated to comply with the RoHS 2 Directive 2011/65/EU and will not be shipped to the EU. Customers may be able to purchase products from  
inventory that were placed on the EU market prior to July 22, 2017 until supplies are depleted. Tektronix is committed to helping you with your solution needs. Please contact your local sales  
representative for further assistance or to determine if alternative product(s) are available. Tektronix will continue service to the end of worldwide support life.  
www.tek.com/MSO5000 25  
Datasheet  
Probes  
Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please  
visit www.tek.com/probes.  
®
TPP0500B  
500 MHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance  
TPP1000  
TPP0502  
TAP2500  
TAP1500  
TDP3500  
TDP1500  
TDP1000  
TDP0500  
TIVM1  
1 GHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance  
500 MHz, 2X TekVPI passive voltage probe  
2.5 GHz TekVPI active single-ended voltage probe  
1.5 GHz TekVPI active single-ended voltage probe  
3.5 GHz TekVPI differential voltage probe with ±2 V differential input voltage  
1.5 GHz TekVPI differential voltage probe with ±8.5 V differential input voltage  
1 GHz TekVPI differential voltage probe with ±42 V differential input voltage  
500 MHz TekVPI differential voltage probe with ±42 V differential input voltage  
Differential Probe; 1 GHz, Up to 50X, ±50 V, TekVPI, 3 Meter Cable  
Differential Probe; 1 GHz, Up to 50X, ±50 V, TekVPI, 10 Meter Cable  
Differential Probe; 800 MHz, Up to 2500X, ±2.5 kV, TekVPI, 3 Meter Cable  
Differential Probe; 800 MHz, Up to 2500X, ±2.5 kV, TekVPI, 10 Meter Cable  
Differential Probe; 500 MHz, Up to 2500X, ±2.5 kV, TekVPI, 3 Meter Cable  
Differential Probe; 500 MHz, Up to 2500X, ±2.5 kV, TekVPI, 10 Meter Cable  
Differential Probe; 200 MHz, Up to 2500X, ±2.5 kV, TekVPI, 3 Meter Cable  
Differential Probe; 200 MHz, Up to 2500X, ±2.5 kV, TekVPI, 10 Meter Cable  
20 MHz TekVPI 150 Ampere AC/DC current probe  
TIVM1L  
TIVH08  
TIVH08L  
TIVH05  
TIVH05L  
TIVH02  
TIVH02L  
TCP0150  
TCP0030A  
TCP0020  
TPP0850  
TRCP0300  
TRCP0600  
TRCP3000  
TMDP0200  
THDP0200  
THDP0100  
P5100A  
120 MHz TekVPI 30 Ampere AC/DC current probe  
50 MHz TekVPI 20 Ampere AC/DC current probe  
2.5 kV, 800 MHz TekVPI high-voltage passive probe  
30 MHz, 250 mA to 300 A, AC current probe  
30 MHz, 500 mA to 600 A, AC current probe  
16 MHz, 500 mA to 3000 A, AC current probe  
±750 V, 200 MHz high-voltage differential probe  
±1.5 kV, 200 MHz high-voltage differential probe  
±6 kV, 100 MHz high-voltage differential probe  
2.5 kV, 500 MHz, 100X high-voltage passive probe  
Recommended software  
TekScopeNL-BAS  
TekScope Anywhere Waveform Analysis and Visualization Node locked license.  
TekScopeFL-BAS  
TekScope Anywhere Waveform Analysis and Visualization floating license.  
TekScopeNL-DJA  
Advanced Jitter Analysis for TekScope Anywhere Node locked license.  
TekScopeFL-DJA  
Advanced Jitter Analysis for TekScope Anywhere floating license.  
GRL-USB-PD  
USB Power Delivery electrical compliance and decode.  
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.  
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.  
26 www.tek.com/MSO5000  
Mixed Signal Oscilloscopes - MSO5000B, DPO5000B Series  
www.tek.com/MSO5000 27  
Datasheet  
ASEAN / Australasia (65) 6356 3900  
Belgium 00800 2255 4835*  
Austria 00800 2255 4835*  
Brazil +55 (11) 3759 7627  
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777  
Canada 1 800 833 9200  
Central East Europe and the Baltics +41 52 675 3777  
Finland +41 52 675 3777  
Central Europe & Greece +41 52 675 3777  
France 00800 2255 4835*  
Denmark +45 80 88 1401  
Germany 00800 2255 4835*  
Hong Kong 400 820 5835  
India 000 800 650 1835  
Italy 00800 2255 4835*  
Japan 81 (3) 6714 3086  
Luxembourg +41 52 675 3777  
The Netherlands 00800 2255 4835*  
Poland +41 52 675 3777  
Russia & CIS +7 (495) 6647564  
Sweden 00800 2255 4835*  
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90  
Norway 800 16098  
Portugal 80 08 12370  
South Africa +41 52 675 3777  
Switzerland 00800 2255 4835*  
USA 1 800 833 9200  
Middle East, Asia, and North Africa +41 52 675 3777  
People's Republic of China 400 820 5835  
Republic of Korea +822 6917 5084, 822 6917 5080  
Spain 00800 2255 4835*  
Taiwan 886 (2) 2656 6688  
United Kingdom & Ireland 00800 2255 4835*  
* European toll-free number. If not accessible, call: +41 52 675 3777  
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com.  
©
Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and  
price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.  
20 Oct 2019 48W-29560-10  
www.tek.com/MSO5000  

相关型号:

MSO5054B

Mixed Signal Oscilloscopes
TEKTRONIX

MSO50MPK1E1T

Telecom and Datacom Connector, 50 Contact(s), Male, Straight, Plug
AMPHENOL

MSO50MPK1SE1T

Telecom and Datacom Connector, 50 Contact(s), Male, Straight, Plug
AMPHENOL

MSO50MPK58E1T

Telecom and Datacom Connector, 50 Contact(s), Male, Straight, Plug
AMPHENOL

MSO50MPK58SE1T

Telecom and Datacom Connector, 50 Contact(s), Male, Straight, Plug
AMPHENOL

MSO50MRK1E1J

Telecom and Datacom Connector, 50 Contact(s), Female, Straight, Receptacle
AMPHENOL

MSO50MRK1E1T

Telecom and Datacom Connector, 50 Contact(s), Female, Straight, Receptacle
AMPHENOL

MSO50MRK58E1J

Telecom and Datacom Connector, 50 Contact(s), Female, Straight, Receptacle
AMPHENOL

MSO50MRK58E1T

Telecom and Datacom Connector, 50 Contact(s), Female, Straight, Receptacle
AMPHENOL

MSO50MRK58SE1T

Telecom and Datacom Connector, 50 Contact(s), Female, Straight, Receptacle
AMPHENOL

MSO50MRM1E1

Telecom and Datacom Connector, 50 Contact(s), Female, Wire Wrap Terminal, Receptacle
AMPHENOL

MSO50MRM58E1

Telecom and Datacom Connector, 50 Contact(s), Female, Wire Wrap Terminal, Receptacle
AMPHENOL