DMM7510-5Y-EW [TEKTRONIX]

DMM 7510 7½-Digit Graphical Sampling Multimeter;
DMM7510-5Y-EW
型号: DMM7510-5Y-EW
厂家: TEKTRONIX, INC.    TEKTRONIX, INC.
描述:

DMM 7510 7½-Digit Graphical Sampling Multimeter

文件: 总27页 (文件大小:1316K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Datasheet  
DMM 7510 7½-Digit Graphical  
Sampling Multimeter  
The DMM7510 combines all the advantages of a precision  
digital multimeter, a graphical touchscreen display, and a  
high speed, high resolution digitizer to create an industry  
first: a graphical sampling multimeter. The digitizer gives  
the DMM7510 unprecedented signal analysis flexibility; the  
five-inch capacitive touchscreen display makes it easy to  
observe, interact with, and explore measurements with  
“pinch and zoom” simplicity. This combination of high  
performance and high ease of use offers unparalleled  
insight into your test results.  
A Tektronix Company  
Capture Waveforms with the Built-in  
1 MS/sec Digitizer  
Key Features  
• Precision multimeter with 3½- to 7½-digit resolution  
Capturing and displaying waveforms and transient events  
just got easier with the DMM7510’s voltage or current  
digitizing function. The built-in 1 MS/sec, 18-bit digitizer  
makes it possible to acquire waveforms without the need  
to use a separate instrument. The digitizing functions  
employ the same ranges that the DC voltage and current  
functions use to deliver exceptional dynamic measurement  
range. In addition, the voltage digitizing function uses the  
same DC voltage input impedance (10 Gor 10 M)  
levels to reduce loading significantly on the DUT.  
• Capture and display waveforms or transients with  
1 MS/sec digitizer  
• Large internal memory buffer; store over 11 million  
readings in standard mode or 27.5 million in  
compact mode  
• 14 PPM basic one-year DCV accuracy  
• 100 mV, 1 , and 10 µA ranges offer the sensitivity  
needed for measuring low level signals such as  
portable device sleep mode currents  
• Make accurate low resistance measurements  
with offset compensated ohms, four-wire, and dry  
circuit functions  
• Auto-calibration feature improves accuracy and  
stability by minimizing temperature and time drift  
• Display more with five-inch, high resolution  
touchscreen interface  
The built-in graphing utility supports displaying and comparing  
measurements or waveforms from up to four reading buffers at once.  
• Readings and screen images can be saved quickly via  
the front panel USB memory port  
• Multiple connectivity options: GPIB, USB, and LXI-  
compliant LAN interfaces  
Advanced triggering  
options make it possible  
to capture a signal at  
precisely the right point.  
• Two-year specifications enable longer  
calibration cycles  
Datasheet  
Accurately Measure  
Make Demanding Measurements  
and Visualize Ultra-Low with Confidence  
Current Drain Levels  
The DMM7510’s design makes the most of Keithley’s low level measurement  
expertise. Features like the low noise input stage and the 32-bit A-to-D converter  
allow this instrument to deliver DC accuracies typically only found in metrology-  
grade instrumentation—but at about half the price of those solutions. The  
DMM7510’s 100 mV, 10 , and 10 µA ranges deliver the sensitivity needed to  
measure low signals with confidence when characterizing today’s demanding  
electronic designs. In addition to one- and two-year accuracy specifications, an  
auto-calibration function ensures greater accuracy between calibration cycles.  
Determine the current drain of  
the components such as the  
microcontroller (MCU) in your low-  
power, battery-operated product as  
well as the product’s total current  
draw. In addition, profile the current  
drain in all of the product’s operating  
states from its sleep mode to its  
transmit mode. Using the enhanced  
accuracy DC current function, the  
DMM7510 can measure a 1 µA sleep  
mode current with 1 pA resolution  
and with 0.375 nA tolerance.  
Furthermore, using the digitizing  
current function, the DMM7510 can  
capture the current wave shapes as  
the product transitions from sleep  
mode to transmit mode.  
The DMM7510 provides noise performance equivalent to  
or better than many 8½-digit DMMs.  
One Power Line Cycle  
Noise Performance  
2µV  
1µV  
0µV  
–1µV  
–2µV  
6½ Digit  
8½ Digit  
DMM7510  
Comparison of the DMM7510’s 1 VDC noise performance with that of typical 6½- and 8½-digit  
multimeters. All data was taken at 1 NPLC with a low thermal short applied to the input.  
Capture the current drain from all the operating  
states – sleep mode to active transmit mode – of  
a component or a product with the DMM7510’s  
digitizing function. Focus in on characteristics of  
the wave shapes with the touchscreen pinch and  
zoom features.  
15 Measurement Functions  
The DMM7510 provides 15 basic measurement functions. In addition to the  
digitizing voltage and current functions, it includes capacitance, ACV and ACI,  
temperature (RTD, thermistor, and thermocouple), 2- and 4-wire resistance,  
dry circuit ohms, period, frequency, diode test, and DC voltage ratio. The  
instrument’s flat menu structure allows for fast configuration and improves  
usability. Its intuitive design lets you to learn how to operate the instrument and  
begin making device measurements faster and with greater confidence.  
RTD, Thermistor, Thermocouple  
2
TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Five-inch touchscreen displays more  
information simultaneously  
Rotary control knob offers an  
alternative to touchscreen navigation  
Online HELP is just a  
button press away  
Store test results  
and screen images  
quickly via the USB 2.0  
memory port  
Lower swipe screen speeds  
access to often-used features  
Front/rear input selector  
Designed for Higher  
Testing Productivity  
DMM7510 Measurement Capabilities  
Logarithmic Scale  
1f  
1p  
1n  
1µ  
1m  
1
1k  
1M  
1010V  
1G  
In addition to its advanced  
DC Voltage  
10nV  
touchscreen, the DMM7510’s front  
panel offers a variety of features that  
enhance its speed, user-friendliness,  
and learnability, including a USB 2.0  
memory I/O port, a HELP key, a rotary  
navigation/control knob, and front/  
rear input selector button. All front-  
panel buttons are backlit to enhance  
visibility.  
AC Voltage  
DC Current  
AC Current  
100nV  
707VRMS  
1pA  
10.1A  
10.1A  
1nA  
Resistance (2-wire)  
Resistance (4-wire)  
Dry Circuit Resistance  
Capacitance  
Ω  
100nΩ  
Ω  
1.2GΩ  
1.2GΩ  
2.4kΩ  
0.1pF  
1.2mF  
Period  
Frequency  
2µs  
330ms  
3Hz  
500kHz  
1010V  
Digitize Voltage  
Digitize Current  
1µV  
0.1nA  
10.1A  
Linear Scale  
The rear panel of the DMM7510  
provides connections and controls  
that simplify configuring multi-  
Thermocouple –200°C  
Thermistor –80°C  
3-Wire RTD –200°C  
4-Wire RTD –200°C  
1820°C  
150°C  
850°C  
850°C  
instrument test solutions, including  
input connectors, remote control  
interfaces (GPIB, USB 2.0 and LXI/  
Ethernet), a D-sub 9-pin digital I/O  
port (for internal/external trigger  
signals and handler control), and TSP-  
Link® jacks for connecting to other  
TSP-enabled instruments.  
–500°  
0°  
500°  
1000°  
1500°  
2000°  
Easily accessible  
current fuses  
Measure Complete and External Trigger  
(8503 BNC Accessory Available)  
LAN/LXI interface  
USB 2.0  
interface  
Six user-defined  
digital I/Os  
GPIB interface  
TEK.COM  
3
Datasheet  
SourceMeter SMU instruments, and the Series 3700A Switch/Multimeter  
systems. TSP-Link supports up to 32 units per GPIB or IP address, so it’s easy  
to scale a system to fit the requirements of an application.  
Flexible System  
Integration and  
Programming  
To offer users maximum programming  
flexibility and simplify configuring  
multi-instrument test systems,  
the DMM7510 includes Keithley’s  
powerful Test Script Processor (TSP®)  
system and SCPI programming  
mode. The embedded scripting  
capability allows running powerful  
test scripts directly on the instrument,  
without the need for an external PC  
controller. These test scripts are  
complete test programs based on an  
easy-to-use yet highly efficient and  
compact scripting language, Lua  
(www.lua.org). Scripts are a collection  
of instrument control commands  
and/or program statements.  
A standard SCPI programming mode supports taking advantage of all of  
the DMM7510’s new features when programming remotely. In addition, the  
instrument is code-compatible with the SCPI language, which many other DMMs  
use. This code compatibility avoids the need to rewrite code that is normally  
associated with upgrading to a new instrument with new capabilities.  
Free Instrument Control Startup Software  
Program statements control script  
execution and provide facilities such  
as variables, functions, branching,  
and loop control. This allows you  
to create powerful measurement  
applications with significantly reduced  
development times. Test scripts can  
contain any sequence of routines  
that are executable by conventional  
programming languages (including  
decision-making algorithms), so  
the instrument can manage every  
facet of the test without the need to  
communicate with a PC for decision-  
making. This eliminates delays due  
to GPIB, Ethernet or USB traffic  
congestion and greatly improves  
overall test times.  
Keithley’s KickStart instrument control startup software lets you begin taking measurements  
in minutes.  
KickStart combines a wide range of functions to enhance  
testing productivity:  
• Instrument-specific UI panel  
• Manual instrument configuration  
• Basic reading display and tabular viewing of data  
• Datalogging  
• Native X-Y data graphing  
• Panning and zooming  
• Basic statistics (native to instrument, mX+b)  
• Saving/exporting data  
TSP technology also offers  
• Connect using any remote interface (GPIB, USB, LAN)  
• Saving instrument setups  
“mainframe-less channel expansion.”  
The TSP-Link® channel expansion  
bus and a 100 Base T Ethernet cable  
allow connecting multiple DMM7510s  
with other TSP-enabled instruments  
in a master-slave configuration so they  
operate as a single integrated system.  
These instruments include the 2450  
and 2460 Graphical SourceMeter®  
SMU instruments, Series 2600B  
• Screenshot capture  
• Command line dialog box  
Ready-to-use Instrument Drivers Simplify  
Programming  
Need to create your own customized application software? Native National  
Instruments LabVIEW®, IVI-C, and IVI-COM drivers are available for downloading  
at www.tek.com to simplify the programming process.  
4
TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Specification Conditions  
This document contains specifications and supplemental information for the DMM7510 7½-Digit Graphical Sampling Multimeter instrument.  
Specifications are the standards against which the DMM7510 is tested. Upon leaving the factory, the Model DMM7510 meets these  
specifications. Supplemental and typical values are nonwarranted, apply at 23°C (73°F), and are provided solely as useful information.  
Measurement accuracies are specified at the DMM7510 terminals under these conditions:  
• Temperature 23° 5°C, 5% to 80% relative humidity, noncondensing.  
• After a 90-minute warmup period.  
• 1 PLC or 5 PLC; for NPLC settings less than 1 PLC, add appropriate ppm of range for peak noise uncertainty from the RMS noise table.  
• Autozero enabled unless otherwise noted.  
• Remote sense operation or properly zeroed local operation.  
• Calibration period: One year or two years (calibration period may vary depending on customer requirements).  
• TACAL = Ambient temperature of last automatic calibration.  
• TCAL = Ambient temperature of last external calibration; factory calibration performed at 23° 1°C.  
DC Voltage  
Accuracy (Input impedance AUTO)  
Accuracy (ppm of reading + ppm of range)  
Input  
24 Hour  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 3  
Range 1  
Resolution  
Impedance 2  
TCAL 1°C 2  
>10 Gor  
100.00000 mV 4  
10 nV  
6 + 9  
4 + 1  
12 + 9  
9 + 2  
18 + 9  
15+ 2  
29 + 9  
26 + 2  
0.1 + 2.5  
0.1 + 0.5  
0.1 + 0.05  
10 M1 %  
>10 Gor  
10 M1 %  
1.0000000 V 4  
10.000000 V 4  
100 nV  
1 µV  
>10 Gor  
10 M1 %  
2 + 0.7  
9 + 1.2  
14 + 1.2  
22 + 1.2  
(18 + 5) 5  
35 + 5  
(19 + 5) 5  
(22 + 5) 5  
40 + 5  
(23 + 5) 5  
(30 + 5) 5  
45 + 5  
(31 + 5) 5  
(0.15 + 0.05) 5  
2.0 + 0.5  
(0.15 + 0.05) 5  
100.00000 V 4  
10 µV  
10 M1 %  
10 M1 %  
8 + 3  
8 + 3  
1000.0000 V 4, 6  
100 µV  
35 + 5  
40 + 5  
45 + 4  
2.0 + 0.5  
RMS Noise (additional peak noise uncertainty) 7  
Applies to ppm of range.  
Peak noise uncertainty is included in DC specifications for 1 PLC.  
Add peak noise uncertainty to measurements for <1 PLC.  
Input impedance set to Auto.  
NOTES  
1. 20% overrange on all ranges except 1% for 1000 V range.  
2. Relative to calibration accuracy.  
3. Add per degree from TCAL 5°C.  
4. When properly zeroed using the Rel function with external cables.  
5. Specified within 30 days of autocalibration, TOPER 5°C from TACAL  
6. For signal levels greater than 500 V, add 0.02 ppm/V to the ppm of the readings specification for measurements exceeding 500 V.  
7. Noise values are based on 1000 readings with autozero on and using low thermal 4-wire short. VRMS noise is typical. Additional peak noise is guaranteed.  
.
TEK.COM  
5
Datasheet  
Examples:  
10 V at 0.006 PLC: 1.2 (from Accuracy table) + 11 (additional peak noise uncertainty) = 12.2 ppm of range.  
10 V at 1 PLC: 1.2 + 0 = 1.2 ppm of range.  
NPLC  
5
Digits  
7½  
100 mV  
0.5  
1 V  
10 V  
0.06  
100 V  
0.3  
1000 V  
0.06  
0.08  
1
7½  
0.5  
0.09  
0.07  
0.4  
0.07  
0.2 8  
6½  
2 (10)  
2 (12)  
3 (17)  
6 (42)  
30 (220)  
0.2 (1.6)  
0.2 (1.6)  
0.4 (2.7)  
3 (18)  
0.1 (1.1)  
0.1 (1)  
0.3 (2.1)  
1 (11)  
1.1 (9.4)  
1.1 (8.9)  
3 (17)  
0.1 (1)  
0.2  
6½  
0.2 (1.1)  
0.3 (2.4)  
3 (18)  
0.06  
0.006  
0.0005  
5½  
4½  
20 (100)  
120 (690)  
3½  
20 (150)  
20 (130)  
20 (150)  
DC Voltage Sense Accuracy  
Accuracy (ppm of reading + ppm of range)  
24 Hour  
TCAL 1°C  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 9  
Range  
100.00000 mV  
1.0000000 V  
10.00000 V  
6 + 14  
12 + 14  
9 + 3  
18 + 14  
15 + 3  
29 + 14  
26 + 3  
0.1 + 2.5  
0.1 + 0.5  
0.1 + 0.05  
4 + 1.5  
2 + 1.0  
9 + 1.8  
14 + 1.8  
22 + 1.8  
DC Voltage Ratio  
For input signals 1% of the range, ratio accuracy = [[VINPUT ppm of reading + VINPUT ppm of range * (VINPUT range/VINPUT input)] + [VSENSE ppm of  
reading + VSENSE ppm of range * (VSENSE range/VSENSE input)]].  
DC Voltage Characteristics  
ADC Linearity  
1.0 ppm of reading + 1.0 ppm of range.  
Input Impedance  
100 mV to 10 V Ranges: Selectable >10 G|| <400 pF (auto) or 10 M1% (10 M).  
100 V to 1000 V Ranges: 10 M1%.  
Input Bias Current  
<50 pA at 23°C under the following conditions: Autozero off or input impedance 10 M.  
Common Mode Current  
<2.1 µA peak-peak in 1 MHz bandwidth.  
<100 nA peak-peak in 1 kHz bandwidth.  
Common Mode Voltage  
500 Vpeak LO terminal to chassis maximum.  
DC Voltage Autozero Off Error  
For 1°C and 10 minutes, add (8 ppm of reading + 15 µV).  
Normal Mode Rejection  
For DC voltage, line frequency 0.1%.  
5 PLC  
110 dB  
60 dB  
1 PLC  
90 dB  
60 dB  
0.2 PLC  
45 dB  
0.01 PLC  
Line Sync On  
Line Sync Off  
NOTES  
8. With line sync on.  
9. Add per degree from TCAL 5°C.  
6
TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Common Mode Rejection  
For DC voltage and 1kunbalanced in LO terminal; AC CMRR is 70 dB.  
NPLC  
Line Sync  
CMRR  
5
1
0.2  
On  
0.2  
Off  
On  
On  
140 dB  
140 dB  
120 dB  
80 dB  
Resistance  
10  
Enhanced Accuracy (within 30 days of autocalibration, TOPER 5°C from TACAL  
)
Accuracy (ppm of reading + ppm of range)  
Test Current 12  
( 5%)  
24 Hour  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 14  
Range 11  
Resolution  
0.1 µΩ  
1 µΩ  
TCAL 1°C 13  
1.0000000 Ω  
10 mA  
10 mA  
1 mA  
15 + 50  
15 + 5  
30 + 50  
30 + 5  
30 + 50  
30 + 5  
30 + 50  
30 + 5  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
70 + 1  
10.000000 Ω  
100.00000 Ω  
10 µΩ  
100 µΩ  
1 mΩ  
12 + 4  
27 + 4  
27 + 4  
27 + 4  
1.0000000 kΩ  
10.000000 k15  
100.00000 k15, 16  
1.0000000 M15, 17  
10.000000 M18  
100.00000 M18  
1.0000000 G18  
1 mA  
12 + 3  
24 + 3  
24 + 3  
24 + 3  
100 µA  
10 µA  
10 µA  
13 + 3  
30 + 3  
30 + 3  
30 + 3  
10 mΩ  
100 mΩ  
1 Ω  
13 + 3  
30 + 3  
30 + 3  
30 + 3  
14 + 3  
30 + 4  
30 + 4  
30 + 4  
||  
0.69 µA 10 MΩ  
150 + 6  
800 + 30  
9000 + 100  
200 + 10  
2000 + 30  
9000 + 100  
200 + 10  
2000 + 30  
9000 + 100  
200 + 10  
2000 + 30  
9000 + 100  
||  
10 Ω  
0.69 µA 10 MΩ  
385 + 1  
||  
100 Ω  
0.69 µA 10 MΩ  
3000 + 1  
Accuracy 19  
Accuracy (ppm of reading + ppm of range)  
Test Current 21  
( 5%)  
24 Hour  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 23  
Range 20  
1 Ω  
Resolution  
TCAL 1°C 22  
0.1 µΩ  
1 µΩ  
10 mA  
10 mA  
1 mA  
15 + 50  
15 + 5  
40 + 50  
40 + 5  
50 + 50  
50 + 5  
70 + 50  
70 + 5  
2.5 + 5  
2.5 + 0.5  
5 + 0.25  
5 + 0.25  
2.5 + 0.25  
5 + 1  
10 Ω  
100 Ω  
10 µΩ  
100 µΩ  
1 mΩ  
10 mΩ  
100 mΩ  
1 Ω  
12 + 4  
35 + 4  
47 + 4  
65 + 4  
1 kΩ  
1 mA  
12 + 3  
30 + 3  
41 + 3  
65 + 3  
10 k24  
100 k24, 25  
1 M24, 26  
10 M27  
100 M27  
1 G27  
100 µA  
10 µA  
10 µA  
10 + 3  
30 + 3  
42 + 3  
65 + 3  
13 + 3  
38 + 3  
50 + 3  
65 + 3  
14 + 3  
38 + 5  
50 + 5  
65 + 5  
5 + 1  
||  
0.69 µA 10 MΩ  
150 + 6  
800 + 30  
9000 + 200  
200 + 10  
2000 + 30  
9000 + 200  
400 + 10  
2000 + 30  
13000 + 200  
600 + 12  
2600 + 30  
14000 + 200  
70 + 1  
||  
10 Ω  
0.69 µA 10 MΩ  
385 + 1  
3000 + 1  
||  
100 Ω  
0.69 µA 10 MΩ  
NOTES  
10. Specifications are for 4-wire resistance, offset compensation on for 10 kmeasurements, and offset compensation off for 10 kmeasurements. 1 range is 4-wire only. For 2-wire,  
with Rel, add 50 mto ppm of range uncertainty. Without Rel and with 1756 test leads, add 100 mto ppm of range uncertainty.  
11. 20% overrange on all ranges.  
12. Test current with offset compensation off, 5%.  
13. Relative to calibration accuracy.  
14. Add per degree from TCAL 5°C.  
15. Specifications are for external cable and load capacitance <1nF.  
16. For offset compensation on, add 10ppm uncertainty to ppm of reading.  
17. For 4-wire 1 M, open lead detector on, add 10 ppm uncertainty to ppm of reading.  
18. Specified for <10% lead resistance mismatch in HI and LO.  
19. Specifications are for 4-wire resistance, offset compensation on for 10 kmeasurements, and offset compensation off for 10 kmeasurements. 1range is 4-wire only. For 2-wire, with  
Rel, add 50 mto ppm of range uncertainty. Without Rel and with 1756 test leads, add 100 mto ppm of range uncertainty.  
20. 20% overrange on all ranges.  
21. Test current with offset compensation off.  
22. Relative to calibration accuracy.  
23. Add per degree from TCAL 5°C.  
24. Specifications are for external cable and load capacitance <1 nF.  
25. For offset compensation on, add 10ppm of uncertainty to ppm of reading.  
26. For 4-wire, 1 M, open lead detection on, add 10ppm uncertainty to ppm of reading.  
27. Specified for <10% lead resistance mismatch in HI and LO.  
TEK.COM  
7
Datasheet  
Resistance Open Circuit DC Voltage 28  
Offset Compensation Off  
Offset Compensation On  
Range 20  
1 Ω  
2-wire  
4-wire  
9.2 V  
4-wire  
9.5 V  
10 Ω  
9.2 V  
14.0 V  
9.5 V  
12.7 V  
6.9 V  
9.2 V  
9.5 V  
100 , 1 kΩ  
10 kΩ  
14.2 V  
9.5 V  
14.3 V  
0.0 V  
100 k, 1 MΩ  
10 Mto 1 GΩ  
14.3 V  
6.9 V  
0.0 V (100 krange only)  
4-Wire Ohms (10k) Offset Compensation On  
RMS Noise (additional peak noise uncertainty) 29  
Applies to ppm of range.  
Peak noise uncertainty is included in DC specifications for 1 PLC.  
Add peak noise uncertainty to measurements for <1 PLC.  
Examples  
1 kat 0.006 PLC: 3 (from Accuracy table) + 26 (additional peak noise uncertainty) = 29 ppm of range.  
1 kat 1 PLC: 3 + 0 = 3 ppm of range.  
NPLC  
5
Digits  
7½  
1 Ω  
2.8  
10 Ω  
0.3  
100 Ω  
0.3  
1 kΩ  
0.07  
10 kΩ  
0.3  
1
7½  
4.2  
0.4  
0.4  
0.12  
0.5  
0.2 30  
6½  
30 (160)  
50 (250)  
110 (490)  
110 (710)  
520 (3420)  
3 (13)  
5 (22)  
11 (47)  
10 (70)  
50 (340)  
3 (13)  
5 (22)  
11 (46)  
10 (70)  
50 (340)  
0.4 (2.6)  
0.6 (3.2)  
1.1 (6.6)  
4 (26)  
1.2 (8.2)  
1.2 (8.3)  
2 (16)  
0.2  
6½  
0.06  
0.006  
0.0005  
5½  
4½  
10 (60)  
50 (300)  
3½  
40 (220)  
2-Wire Ohms  
RMS Noise (additional peak noise uncertainty) 29  
Applies to ppm of range.  
Peak noise uncertainty is included in DC specifications for 1 PLC.  
Add peak noise uncertainty to measurements for <1 PLC.  
Examples  
10 kat 0.006 PLC: 3 (from Accuracy table) + 5 (50 mwith Rel ) + 43 (additional peak noise uncertainty)  
= 51 ppm of range.  
10 kat 1 PLC: 3 + 5 + 0 = 8 ppm of range.  
NPLC  
5
Digits  
7½  
10 Ω  
1.1  
100 Ω  
0.8  
1 kΩ  
0.1  
10 kΩ  
0.2  
1
7½  
0.6  
0.6  
0.09  
0.4  
0.2 30  
6½  
2 (17)  
2 (17)  
3 (22)  
6 (50)  
30 (300)  
2 (10)  
2 (14)  
3 (19)  
6 (50)  
30 (230)  
0.2 (1.5)  
0.3 (1.6)  
0.4 (3.7)  
3 (21)  
0.8 (6.3)  
0.8 (6.4)  
2 (12)  
0.2  
6½  
0.06  
0.006  
0.0005  
5½  
4½  
6 (43)  
30 (210)  
3½  
20 (150)  
NOTES  
28. Open circuit voltage is typical, measured from input HI to LO, SHI and SLO open. For 1 to 1 Mranges using an external digital multimeter (DMM) set to 10 Minput impedance; for  
10 Mto 1 Granges, set external DMM to >10 Ginput impedance.  
29. Noise values are based on 1000 readings with autozero on and using low thermal 4-wire short. RMS noise is typical. Additional peak noise is guaranteed.  
30. With line sync on.  
8
TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Resistance Characteristics  
Maximum 4-Wire Ohms Lead Resistance  
5 per lead for 1range, 10% of range per lead for 10 to 1 kranges; 1 kper lead for all other  
ranges.  
Offset Compensation  
Open Lead Detector  
Autozero Off Error  
Selectable on 4-wire, 1 to 100 kranges.  
Default is off.  
For 2-wire ohms, 1°C and 10 minutes, add (8ppm of reading) + 1.5 mfor 10 , 15 mfor 100 and  
1 kranges, 150 mfor 10 krange, 1.5 for 100 krange, and 15 for all other ranges.  
For 4-wire ohms, 1°C and 10 minutes, add (8 ppm of reading).  
Input Current Limit  
For signals with a magnitude of +12 V to +40 V or –12 V to –40 V: 13 mA source or sink, typical.  
For signals with a magnitude of greater than +40 V or –40 V: 130 µA source or sink, typical.  
Dry Circuit Resistance  
Enhanced Accuracy (within 30 days of autocalibration, TOPER 5ºC from TACAL  
)
Accuracy (ppm of reading + ppm of range)  
Test  
Current 35  
( 5%)  
Open Circuit  
24 Hour  
90 Day  
1 Year  
TCAL 5°C  
2 years  
TCAL 5°C  
Temperature  
Coefficient 34  
Range 31  
Resolution  
1 µΩ  
DUT Voltage 32 TCAL 1°C 33  
TCAL 5°C  
1.000000 Ω  
10.00000 Ω  
100.0000 Ω  
1.000000 kΩ  
10.00000 kΩ  
10 mA  
1 mA  
25 mV  
25 mV  
25 mV  
25 mV  
25 mV  
25 + 80  
25 + 80  
25 + 80  
25 + 80  
25 + 80  
50 + 80  
50 + 80  
90 + 80  
180 + 80  
320 + 80  
50 + 80  
50 + 80  
90 + 80  
180 + 80  
320 + 80  
50 + 80  
50 + 80  
90 + 80  
180 + 80  
320 + 80  
1.5 + 0.1  
1.5 + 0.1  
1.5 + 0.1  
1.5 + 0.1  
1.5 + 0.1  
10 µΩ  
100 µΩ  
1 mΩ  
100 µA  
10 µA  
5 µA  
10 mΩ  
Accuracy  
Accuracy (ppm of reading + ppm of range)  
Test  
Current 35  
( 5%)  
Open Circuit  
24 Hour  
90 Day  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 34  
Range 31  
Resolution  
1 µΩ  
DUT Voltage 32 TCAL 1°C 33  
TCAL °C  
1.000000 Ω  
10.00000 Ω  
100.0000 Ω  
1.000000 kΩ  
10.00000 kΩ  
10 mA  
1 mA  
25 mV  
25 mV  
25 mV  
25 mV  
25 mV  
25 + 80  
25 + 80  
25 + 80  
25 + 80  
25 + 80  
50 + 80  
50 + 80  
90 + 80  
180 + 80  
320 + 80  
70 + 80  
70 + 80  
90 + 80  
90 + 80  
2.5 + 1  
5 + 1  
10 µΩ  
100 µΩ  
1 mΩ  
100 µA  
10 µA  
5 µA  
140 + 80  
400 + 80  
800 + 80  
200 + 80  
600 + 80  
1300 + 80  
2.5 + 1  
5 + 1  
10 mΩ  
8 + 1  
RMS Noise (additional peak noise uncertainty) 36  
Applies to ppm of range.  
Peak noise uncertainty is included in DC specifications for 1 PLC.  
Add peak noise uncertainty to measurements when < 1 PLC.  
NOTES  
31. 20% overrange on all ranges, except 2.4 k for the 10 k range.  
32. Maximum clamp voltages are DC, typical accuracy is 20%. Add 20% for offset compensation on.  
33. Relative to calibration accuracy.  
34. Add per degree from TCAL 5°C.  
35. Test current with offset compensation off.  
36. Noise values are based on 1000 readings with autozero on and using low thermal 4-wire short. RMS noise is typical. Additional peak noise is guaranteed.  
TEK.COM  
9
Datasheet  
Examples:  
10 at 0.2 PLC: 80 (from Accuracy table) + 230 (additional peak noise uncertainty) = 310 ppm of range.  
10 at 1 PLC: 80 + 0 = 80 ppm of range.  
NPLC  
5
Digits  
7½  
1 Ω  
10  
10 Ω  
11  
100 Ω  
6
1 kΩ  
5
10 kΩ  
0.9  
1
7½  
9
9
7
7
0.8  
0.2 37  
6½  
30 (130)  
60 (220)  
70 (350)  
130 (750)  
520 (3550)  
30 (120)  
60 (230)  
70 (350)  
120 (830)  
530 (3520)  
30 (120)  
50 (190)  
50 (290)  
110 (700)  
530 (3380)  
30 (120)  
50 (190)  
50 (280)  
100 (690)  
500 (3370)  
3 (16)  
0.2  
6½  
9 (35)  
20 (90)  
20 (110)  
100 (670)  
0.06  
0.006  
0.0005  
5½  
4½  
3½  
Dry Circuit Resistance Characteristics  
Maximum 4-Wire Ohms Lead Resistance  
0.5 per lead for 1 range.  
10% of range per lead for 10 to 100 ranges.  
50 per lead for 1 kto 10 kranges.  
Input Current Limit  
Offset Compensation  
Autozero Off Error  
For signals greater than 20 mV, current limited, 13 mA typical.  
Selectable on 1 to 10 kranges.  
For 1°C and 10 minutes, add 8 ppm of reading.  
DC Current  
Enhanced Accuracy (within 30 days of autocalibration, TOPER 5°C from TACAL  
)
Accuracy (ppm of reading + ppm of range)  
Maximum  
Burden Voltage  
24 Hour  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 40  
Range 38  
Resolution  
1 pA  
TCAL 1°C 39  
10.000000 µA  
100.00000 µA  
1.0000000 mA  
10.000000 mA  
100.00000 mA  
1.0000000 A  
3.000000 A  
15 mV  
15 mV  
30 + 30  
20 + 5  
75 + 30  
60 + 9  
75 + 30  
60 + 9  
75 + 30  
60 + 9  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
0.15 + 0.1  
50 + 10  
10 pA  
100 pA  
1 nA  
15 mV  
30 + 5  
60 + 9  
60 + 9  
60 + 9  
20 mV  
40 + 5  
60 + 9  
60 + 9  
60 + 9  
10 nA  
100 nA  
1 µA  
200 mV  
400 mV  
1300 mV  
650 mV  
50 + 18  
150 + 50  
200 + 40  
700 + 275  
150 + 30  
400 + 50  
400 + 40  
800 + 275  
150 + 30  
400 + 50  
400 + 40  
1500 + 275  
150 + 30  
400 + 50  
400 + 40  
2000 + 275  
10.000000A 41  
1 µA  
NOTES  
37. With line sync on.  
38. 20% overrange supported for all ranges except for 3 A and 10 A, which are 1% supported.  
39. Relative to calibration accuracy.  
40. Add per degree from TCAL 5°C.  
41. Rear input terminals only.  
10 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Accuracy  
Accuracy (ppm of reading + ppm of range)  
Maximum  
Burden Voltage  
24 Hour  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 40  
Range 38  
Resolution  
1 pA  
TCAL 1°C 39  
10.000000 µA  
100.00000 µA  
1.0000000 mA  
10.000000 mA  
100.00000 mA  
1.0000000 A  
3.000000 A  
15 mV  
15 mV  
30 + 30  
20 + 5  
100 + 30  
75 + 12  
125 + 40  
100 + 15  
100 + 15  
100 + 15  
400 + 30  
450 + 50  
450 + 40  
1500 + 275  
175 + 50  
150 + 20  
150 + 20  
150 + 20  
500 + 30  
500 + 50  
500 + 40  
2000 + 275  
10 + 8  
10 + 3  
10 + 3  
10 + 3  
50 + 5  
10 + 10  
10 + 10  
50 + 10  
10 pA  
100 pA  
1 nA  
15 mV  
30 + 5  
75 + 12  
20 mV  
40 + 5  
75 + 12  
10 nA  
100 nA  
1 µA  
200 mV  
400 mV  
1300 mV  
650 mV  
50 + 18  
150 + 50  
200 + 40  
700 + 275  
300 + 30  
400 + 50  
400 + 40  
800 + 275  
10.000000 A 41  
1 µA  
RMS Noise (additional peak noise uncertainty) 42  
Applies to ppm of range.  
Peak noise uncertainty is included in DC specifications for 1 PLC.  
Add peak noise uncertainty to measurements when <1 PLC.  
Examples  
1 mA at 0.006 PLC: 9 (from Accuracy table) + 20 (additional peak noise uncertainty) = 29 ppm of range.  
1 mA at 1 PLC: 9 +0 = 9 ppm of range.  
NPLC  
5
Digits  
7½  
10 µA  
0.15  
100 µA  
0.14  
1 mA  
0.09  
10 mA  
0.1  
100 mA  
0.3  
1A  
0.3  
3A  
0.2  
10A 43  
0.8  
1
7½  
0.4  
0.13  
0.1  
0.1  
0.5  
0.5  
0.3  
1.2  
0.2  
6½  
0 (220)  
0 (23)  
0.2 (3.4)  
1.2 (3.8)  
1.3 (5.6)  
3 (20)  
0.2 (1.6)  
0.3 (1.8)  
0.4 (3.9)  
2 (20)  
2 (10)  
1.9 (9.8)  
2 (14)  
2 (11)  
2 (10)  
2 (14)  
4 (31)  
30 (190)  
0.7 (4.6)  
0.8 (5)  
1.2 (7.7)  
7 (51)  
4 (32)  
8 (37)  
10 (59)  
20 (110)  
60 (420)  
0.2 44  
0.06  
0.006  
0.0005  
6½  
120 (260)  
130 (280)  
130 (350)  
260 (2110)  
12 (26)  
12 (29)  
14 (42)  
30 (300)  
5½  
4½  
4 (30)  
30 (190)  
3½  
20 (150)  
20 (160)  
70 (510)  
DC Current Characteristics  
Range  
10 µA  
100 µA  
1 mA  
10 mA  
100 mA  
1 A  
3 A  
10 A 43  
Effective Internal Shunt Value 45  
1 kΩ  
100 Ω  
10 Ω  
1 Ω  
0.1 Ω  
0.1 Ω  
0.1 Ω  
0.005 Ω  
Autozero Off Error: For 1°C and 10 minutes add  
(8 ppm of reading + range error)  
150 pA  
1.5 nA  
15 nA  
150 nA  
15 µA  
150 µA  
150 µA  
3 mA  
Overload Recovery: For each additional sustained amp  
beyond 1.5 A, add the following initial ppm of range  
error until thermally settled after overload recovery  
15500  
1800  
150  
150  
6500  
200  
NOTES  
42. Noise values are based on 1000 readings with autozero on and AMPS terminal open. RMS noise is typical. Additional peak noise is guaranteed.  
43. Rear input terminals only.  
44. With line sync on.  
45. Values are typical and guaranteed by design.  
TEK.COM 11  
Datasheet  
Temperature  
4-Wire RTD or 3-Wire RTD  
Types: 100 platinum PT100, D100, F100, PT385, PT3916; or user-configurable 0 to 10 k.  
Accuracy °C  
Temperature Coefficient 46  
Type  
Range  
Resolution  
0.01 °C  
2 Year, TCAL 5°C  
0.06 °C  
4-Wire RTD  
3-Wire RTD 47 –200 to 850 °C  
–200 to 850 °C  
0.003 °C/°C  
0.003 °C/°C  
0.01 °C  
0.75 °C  
Thermistor  
Types: 2.252 k, 5 k, and 10 k.  
Accuracy °C  
Type  
Range  
Resolution  
2 Year, TCAL 5°C  
Temperature Coefficient 46  
Thermistor  
–80 to +150 °C  
0.01 °C  
0.08 °C  
0.002 °C/°C  
Thermocouple  
Types: B, E, J, K, N, R, S, T  
Accuracy °C  
2 Year, TCAL 5°C 48  
Simulated  
Reference Junction  
Temperature  
Coefficient 46  
Type  
Range  
Resolution  
0.1 °C  
B
E
J
350 to +1820 °C  
−200 to +1000 °C  
−200 to +760 °C  
−200 to +1372 °C  
−200 to +1300 °C  
0 to +1768 °C  
0.6 °C  
0.03 °C/°C  
0.03 °C/°C  
0.03 °C/°C  
0.03 °C/°C  
0.03 °C/°C  
0.03 °C/°C  
0.03 °C/°C  
0.03 °C/°C  
0.001 °C  
0.001 °C  
0.001 °C  
0.001 °C  
0.1 °C  
0.2 °C  
0.2 °C  
K
N
R
S
T
0.2 °C  
0.2 °C  
0.6 °C  
0 to +1768 °C  
0.1 °C  
0.6 °C  
−100 to +400 °C  
0.001 °C  
0.2 °C  
Continuity  
Accuracy (ppm of reading + ppm of range)  
Range 49  
Resolution  
Test Current  
Open Circuit Voltage  
14.0 V  
2 Year, TCAL 5°C  
100 + 100  
Temperature Coefficient 50  
1.0000 kΩ  
100 mΩ  
1 mA  
2.5 + 1  
Continuity Characteristics  
Continuity High Limit  
User-selectable; default 10 .  
NOTES  
46. Add per degree from TCAL 5°C; specifications without autocalibration.  
47. For 3-wire RTD, accuracy is for <0.1 lead resistance mismatch for input HI and LO. Add 0.25°C/0.1 of HI-LO lead resistance mismatch.  
48. Exclusive of cold-junction errors.  
49. Specifications exclude lead resistance.  
50. Add per degree from TCAL 5°C; specifications without autocalibration.  
12 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Capacitance  
Accuracies specified for additional cable and stray capacitance properly zeroed with the Rel function.  
Accuracy  
Accuracy  
(% of reading + % of range)  
Charge  
Maximum  
Circuit Voltage  
2 years  
TCAL 5°C  
Temperature  
Coefficient 50  
Range 51  
1.0000 nF  
10.000 nF  
100.00 nF  
1.0000 µF  
10.000 µF  
100.00 µF  
1000.0 µF  
Resolution  
0.1 pF  
1 pF  
Current 52, 53  
1.1 µA  
1.1 µA  
10 µA  
100 µA  
100 µA  
1 mA  
2.8 V  
2.8 V  
3 V  
1 + 0.2  
1 + 0.1  
0.15 + 0.05  
0.15 + 0.01  
0.01 + 0.01  
0.01 + 0.01  
0.01 + 0.01  
0.01 + 0.01  
0.01 + 0.01  
10 pF  
0.4 + 0.1  
0.4 + 0.1  
0.4 + 0.1  
0.4 + 0.1  
0.5 + 0.1  
0.1 nF  
1 nF  
3 V  
3 V  
10 nF  
3 V  
0.1 µF  
10 mA  
3 V  
Diode  
Accuracy (ppm of reading + ppm of range)  
Voltage  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 50  
Measure Range 51  
Resolution  
Bias Level (Selectable)  
10.000000 V  
1 µV  
10 µA / 100 µA / 1 mA  
20 + 5  
30 + 5  
45 + 5  
2.5 + 1  
Digitize Voltage  
Accuracy (Input Impedance AUTO)  
Accuracy (ppm of reading + ppm of range)  
90 Day  
TCAL 5°C  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 58  
Range 54, 55  
100.000 mV  
1.00000 V  
Resolution 56  
1 µV  
Input Impedance 57  
>10 Gor 10 M1%  
>10 Gor 10 M1%  
>10 Gor 10 M1%  
10 M1%  
210 + 100  
110 + 75  
110 + 75  
110 + 75  
110 + 75  
220 + 100  
120 + 75  
120 + 75  
120 + 75  
120 + 75  
230 + 100  
130 + 75  
130 + 75  
130 + 75  
130 + 75  
15 + 20  
15 + 20  
10 + 20  
15 + 20  
10 + 20  
10 µV  
10.0000 V  
0.1 mV  
1 mV  
100.000 V 59  
1000.00 V 60  
10 mV  
10 M1%  
NOTES  
51. 20% overrange on all ranges.  
52. Charging current values are typical, guaranteed by design.  
53. Discharge current limited to <13 mA.  
54. For DC coupling, 20% overrange for 100 mV to 100 V. For AC coupling, 500% overrange 100 mV to 100 V. 1% for 1000 V range DC and AC coupling.  
55. Accuracy with sample rate 1k per second, aperture auto, and 100 reading buffer average.  
56. Power up default is 4½ digits.  
57. User-selectable.  
58. Add per degree from TCAL 5%.  
59. For 100 V range, input impedance auto and without ACAL, add 100ppm of range additional uncertainty and 15 ppm/°C additional uncertainty for “of range” temperature coefficient for  
operation outside of TCAL 5°C.  
60. For signal levels greater than 500 V, add 0.02 ppm/V to the ppm of the readings specification for measurements exceeding 500 V.  
TEK.COM 13  
Datasheet  
Signal Characteristics 61, 62, 63  
Typical AC and DC Coupled  
Analog  
Maximum  
THD  
DC-coupled AC-coupled Filter AC-coupled Filter  
AC Coupling  
Bandwidth Flatness Error 20 kHz Signal  
Settling  
FAST Settling  
Time (0.5%)  
SLOW Settling Time Low Frequency  
Range  
(–3dB)  
600 kHz  
600 kHz  
600 kHz  
3 Hz to 20 kHz 64 (–1dB FS) 65  
Time (0.5%)  
(0.5%)  
2.3 s  
2.5 s  
2.5 s  
(–3dB) point 66  
1 Hz  
100.000 mV  
1.00000 V  
10.0000 V  
0.015 dB  
0.01 dB  
0.01 dB  
0.04 %  
0.03 %  
0.01 %  
5 µs  
6 µs  
4 µs  
80 ms  
80 ms  
80 ms  
1 Hz  
1 Hz  
Typical DC Coupled  
Total Harmonic  
Distortion (THD)  
1 kHz Signal  
Maximum  
Analog Bandwidth  
(–3dB)  
Flatness Error  
Settling Time  
(0.5%)  
Range  
3 Hz to 1 kHz 64  
(–1dB FS) 65  
100.000 V  
1000.00 V  
20 kHz 67  
0.1 dB  
0.1 dB  
1.3 %  
1.8 %  
160 µs  
80 µs  
20 kHz  
Typical AC Coupled  
Analog  
Bandwidth  
(–3dB)  
Maximum  
Flatness Error  
3 Hz to 20 kHz  
Filter FAST  
Filter SLOW  
Low Frequency  
Settling Time Settling Time Coupling Point 66  
Range  
(0.5%)  
80 ms  
80 ms  
(0.5%)  
(–3dB)  
100.000 V  
1000.00 V  
600 kHz  
600 kHz  
0.1 dB  
0.1 dB  
2.3 s  
1 Hz  
2.3 s  
1 Hz  
DC-Coupled Additional Noise Uncertainty,  
Typical 68  
DC-coupled Total Harmonic Distortion (THD),  
Typical 69  
Total Harmonic Distortion, Digitize Voltage  
RMS Noise, Digitize Voltage  
1000  
-50  
-60  
-70  
100  
100mV  
100mV  
1V  
-80  
1V  
10  
1
-90  
-100  
-110  
-120  
10V  
10V  
100V  
1000V  
100V  
1000V  
0.1  
1k  
2k  
5k 10k 20k 50k 100k 200k 500k 1M  
1k  
2k  
5k  
10k  
20k  
50k  
100k  
200k  
Samples per Second  
Samples per Second  
NOTES  
61. Accuracy with sample rate 1M per second and aperture 1 µs.  
62. Verified with sine wave input and DC content 3% of range.  
63. For AC coupling, maximum crest factor of 5.  
64. For DC coupled, 0dB reference frequency is 3 Hz. For AC coupled, 0dB reference frequency is 1 kHz. For AC coupled operation below 1 kHz, add 0.1 dB.  
65. Exclusive of source input noise.  
66. With AC coupling frequency = 3 Hz and AC coupling filter = Slow.  
67. For input impedance auto, bandwidth is 6 kHz.  
68. Specified with aperture auto and 4-wire short on input terminals. For 100 V range, input impedance 10 M , multiply by 2.5. For all ranges and sample rate >1 k, add an additional 3× RMS  
noise uncertainty to ppm of range.  
69. Specified with aperture auto and 1 kHz sine wave input. Distortion is calculated using first five harmonics.  
14 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
DC-Coupled Effective Number Of Bits (ENOB), Typical 70  
Effective Number of Bits (ENOB), Digitize Voltage  
18  
16  
14  
12  
10  
8
100mV  
1V  
10V  
1k  
2k  
5k  
10k  
20k  
50k  
100k  
200k  
Samples per Second  
Digitize Current  
DC Accuracy 71  
Accuracy (ppm of reading + ppm of range)  
90 Day  
1 Year  
TCAL 5°C  
2 Year  
TCAL 5°C  
Temperature  
Coefficient 74  
Range 72  
10.0000 µA  
100.000 µA  
1.00000 mA  
10.0000 mA  
100.000 mA  
1.00000 A  
Resolution 73  
Burden Voltage  
15 mV  
TCAL 5°C  
150 + 75  
150 + 75  
150 + 75  
150 + 75  
340 + 100  
400 + 110  
650 + 150  
950 + 350  
0.1 nA  
1 nA  
160 + 75  
160 + 75  
170 + 75  
170 + 75  
30 + 15  
30 + 15  
30 + 15  
30 + 15  
50 + 20  
50 + 25  
50 + 25  
50 + 25  
15 mV  
10 nA  
100 nA  
1 µA  
15 mV  
160 + 75  
170 + 75  
20 mV  
160 + 75  
170 + 75  
200 mV  
400 mV  
1300 mV  
650 mV  
450 + 100  
500 + 110  
900 + 150  
1500 + 350  
560 + 100  
600 + 110  
900 + 150  
2000 + 350  
10 µA  
100 µA  
100 µA  
3.00000 A  
10.0000 A 75  
NOTES  
70. Specified with aperture Auto, 100Hz sine wave for sample rate 5k, and 1kHz sine wave for sample rate 10k. For the 100V and 1000V ranges, use the 1V and 10V range ENOB,  
respectively; guaranteed by design.  
71. Accuracy with sample rate 1k per second, aperture auto, and 100 reading buffer average.  
72. 20% overrange on all ranges except 3.3% for 3A and 10A ranges.  
73. Power up default is 4½ digits.  
74. Add per degree from TCAL 5°C.  
75. Rear input terminals only.  
TEK.COM 15  
Datasheet  
Signal Characteristics, Typical 76  
Total Harmonic  
Distortion (THD)  
20 kHz Signal  
(–1dB FS)  
DC-coupled  
Settling Time  
(0.5%)  
Maximum Flatness Error  
Analog Bandwidth  
(–3dB)  
Range 72  
10.0000 µA  
100.000 µA  
1.00000 mA  
10.0000 mA  
100.000 mA  
1.00000 A 77  
3.0000 A 77  
3 Hz to 20 kHz  
0.15 dB  
0.15 dB  
0.1 dB  
100 kHz  
100 kHz  
100 kHz  
100 kHz  
100 kHz  
100 kHz  
100 kHz  
100 kHz  
0.02 %  
0.01 %  
0.01 %  
0.01 %  
0.02 %  
0.02 %  
0.02 %  
0.02 %  
8 µs  
7 µs  
3 µs  
8 µs  
5 µs  
6 µs  
6 µs  
6 µs  
0.1 dB  
0.1 dB  
0.1 dB  
0.1 dB  
10.0000 A 75, 77, 78  
0.1 dB  
Additional Noise Uncertainty, Typical 79  
Total Harmonic Distortion (THD), Typical 80  
RMS Noise, Digitize Current  
Total Harmonic Distortion, Digitize Current  
1000  
-70  
-80  
100  
10  
1
10µA  
100µA  
1mA  
-90  
-100  
-110  
-120  
10µA  
100µA  
1mA  
10mA  
100mA, 1A  
3A  
10mA  
100mA  
10A  
1k  
2k  
5k  
10k  
20k  
50k  
100k 200k  
1k  
2k 5k 10k 20k 50k 100k 200k 500k 1M  
Samples per Second  
Samples per Second  
NOTES  
76. Verified with sine wave input and DC content 3% of range.  
77. 10A range is available only on the rear input terminals.  
78. 10A flatness verified to 10kHz; 100kHz guaranteed by design.  
79. Specified with aperture Auto and open input terminals. For all ranges and for 1k sample rate, add an additional 3× RMS noise uncertainty to ppm of range.  
80. Specified with aperture Auto and 1kHz sine wave input. Distortion is calculated using first five harmonics. For the 1A, 3A, and 10A ranges, use the 100mA range accuracy; guaranteed  
by design.  
16 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Effective Number Of Bits (ENOB), Typical 81  
Effective Number of Bits (ENOB), Digitize Current  
18  
16  
14  
10uA  
100uA  
1mA  
12  
10  
8
10mA  
100mA  
1k  
2k  
5k  
10k  
20k  
50k  
100k  
200k  
Samples per Second  
Digitizer Characteristics  
Maximum Resolution  
Measurement Input Coupling  
Sampling Rate 82  
18 bits.  
DC or AC (voltage only).  
Programmable 1 k through 1 million.  
Volatile Sample Memory with Timestamp  
27.5 million.  
Minimum Record Time  
Timestamp Resolution  
Timestamp Accuracy  
1 µs.  
1 ns with standard or full buffer style. 1 µs with compact buffer style.  
With standard or full buffer style, 20 ns between adjacent readings, with total buffer time <2 s.  
With compact buffer style, 2 µs adjacent readings, with total buffer buffer time <2 s.  
Maximum Record Length  
8 million.  
NOTES  
81. Specified with aperture Auto, 100 Hz sine wave for sample rate 5 k, and 1 kHz sine wave for sample rate 10 k. For the 1 A, 3 A, and 10 A ranges, use the 100 mA ENOB; guaranteed  
by design.  
82. Sample rate is not continuously adjustable. For valid discrete settings, see the DMM7510 Reference Manual.  
TEK.COM 17  
Datasheet  
True RMS AC Voltage and AC Current  
1-Year Accuracy: (% of reading + % of range) TCAL 5°C  
3 Hz to  
5 Hz  
5 Hz to  
10 Hz  
10 Hz to  
20 kHz  
20 kHz to  
50 kHz  
50 kHz to  
100 kHz  
100 kHz to  
300 kHz  
Function  
Range 83  
100.0000 mV  
1.000000 V  
10.00000 V  
100.0000 V  
700.000 V  
Resolution  
0.1 µV  
1 µV  
1.0 + 0.03  
1.0 + 0.03  
1.0 + 0.03  
1.0 + 0.03  
1.0 + 0.03  
0.30 + 0.03  
0.30 + 0.03  
0.30 + 0.03  
0.30 + 0.03  
0.30 + 0.03  
0.06 + 0.03  
0.06 + 0.03  
0.06 + 0.03  
0.06 + 0.03  
0.06 + 0.03  
0.14 + 0.05  
0.14 + 0.05  
0.14 + 0.05  
0.14 + 0.05  
0.14 + 0.05  
0.6 + 0.08  
0.6 + 0.08  
0.6 + 0.08  
0.6 + 0.08  
0.6 + 0.08  
4.0 + 0.5  
4.0 + 0.5  
4.0 + 0.5  
4.0 + 0.5  
4.0 + 0.5  
Voltage 84  
10 µV  
100 µV  
1 mV  
Temperature  
Coefficient/°C  
(all ranges)  
0.01 + 0.003 0.03 + 0.003 0.005 + 0.003 0.006 + 0.005 0.01 + 0.006  
0.03 + 0.01  
1-Year Accuracy: (% of reading + % of range) TCAL 5°C  
Function  
Range 83  
Resolution 3 Hz to 5 Hz 5 Hz to 10 Hz  
10 Hz to 2 kHz  
0.08 + 0.03  
0.08 + 0.03  
0.08 + 0.03  
0.20 + 0.04  
0.20 + 0.05  
0.40 + 0.05  
2 kHz to 5 kHz  
0.09 + 0.03  
0.09 + 0.03  
0.09 + 0.03  
0.88 + 0.04  
0. 88 + 0.05  
0. 88 + 0.05  
5 kHz to 10 kHz  
0.09 + 0.03  
0.09 + 0.03  
0.01 + 0.006  
0.01 + 0.006  
2.0 + 0.04  
1.000000 mA  
10.00000 mA  
100.0000 mA  
1.000000 A  
3.000000 A  
10.00000 A 85  
1 nA  
10 nA  
100 nA  
1 µA  
1.0 + 0.04  
1.0 + 0.04  
1.0 + 0.04  
1.0 + 0.04  
1.0 + 0.05  
1.0 + 0.05  
0.30 + 0.04  
0.30 + 0.04  
0.30 + 0.04  
0.30 + 0.04  
0.30 + 0.05  
0.40 + 0.05  
Current 84  
1 µA  
10 µA  
2.0 + 0.05  
Temperature  
Coefficient/°C  
(all ranges)  
0.10 + 0.004 0.030 + 0.004  
0.005 + 0.003  
0.006 + 0.005  
0.006 + 0.005  
Additional AC Uncertainties – Low Frequency Uncertainty  
Detector Bandwidth (BW)  
Additional Uncertainty  
(% of reading), Lower  
Frequency Uncertainty  
3 BW  
(3 Hz to 300 kHz)  
30 BW  
(30 Hz to 300 kHz)  
300 BW  
(300 Hz to 300 kHz)  
20 Hz to 30 Hz  
30 Hz to 50 Hz  
50 Hz to 100 Hz  
100 Hz to 200 Hz  
200 Hz to 300 Hz  
300 Hz to 500 Hz  
> 500 Hz  
0
0
0
0
0
0
0
0.3  
0
0
4.0  
0.72  
0.18  
0.07  
0
0
0
0
0
NOTES  
83. 20% overrange on AC functions except 1% on 700 V, 3.33% on 3 A, and 1% on 10 A. Default resolution is 6½ digits.  
84. Specifications are for detector bandwidth of 3Hz and sine wave inputs >5% of range. Detector bandwidth of 3 Hz and 30 Hz are multisample A/D conversions. Detector bandwidth of  
300 Hz is a single A/D conversion, programmable from 0.0005 PLC to 15 PLC (60 Hz), 12 PLC (50 Hz). Default condition set to 1 PLC.  
85. Rear terminals only.  
18 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Additional AC Voltage Crest Factor Uncertainties 86  
Additional Uncertainty  
(% of reading)  
Maximum Crest Factor:  
5 at Range Full Scale  
Input Signal Frequency Detector Bandwidth  
1 to 2  
1.00  
0.50  
0.20  
0.20  
0.05  
0.50  
0.05  
2 to 3  
4.00  
1.20  
0.30  
0.30  
0.15  
3 to 4  
4.80  
1.30  
0.60  
0.60  
0.30  
1.30  
0.30  
4 to 5  
5.00  
1.40  
0.90  
0.90  
0.40  
1.50  
1.20  
3 Hz to 5 Hz  
5 Hz to 10 Hz  
3 Hz  
3 Hz  
10 Hz to 30 Hz  
5 Hz to 100 Hz  
100 Hz to 300 Hz  
100 Hz to 300 Hz  
500 Hz to 10 kHz  
3 Hz  
30 Hz  
30 Hz  
300 Hz  
300 Hz  
1.20  
0.15  
AC Voltage Characteristics  
Measurement Method  
AC-coupled, true RMS.  
Input Impedance  
1 M2% || <150 pF.  
Volt*Hertz Product  
<2.1 × 107 V*Hz verified; input frequency verified for <300 kHz.  
AC Current Characteristics  
Measurement Method  
AC-coupled, true RMS.  
Range  
1 mA  
10 mA 100 mA  
1 A  
3 A  
10 A 87  
Burden Voltage (RMS)  
<16 mV <20 mV <0.2 V  
<0.4 V  
<1.3 V <0.65 V  
Overload Recovery: For each additional  
sustained ampere beyond 1.5 A, add  
the following initial % of range error until  
thermally settled after overload recovery  
0.006  
0.006  
0.12  
0.05  
Frequency and Period  
Measurement Accuracy 88  
Accuracy, (ppm of reading + ppm of aperture time)  
Frequency: 3 Hz to 500 kHz  
Period: 333 ms to 2 µs  
Measurement  
Resolution  
Aperture  
250 ms  
100 ms  
10 ms  
1 Year, TCAL 5°C  
80 + 0.333  
80 + 3.33  
2 Year, TCAL 5°C  
160 + 0.333  
160 + 3.33  
0.1 ppm  
0.1 ppm  
0.1 ppm  
80 + 33.3  
160 + 33.3  
NOTES  
86. Applies for non-sine wave inputs, DC content 3% of range, maximum crest factor 5.0. For bandwidth 30Hz, autozero off, 6½ digits at 1 PLC, 3½ digits at 0.0005 PLC.  
87. Rear input terminals only.  
88. Specified for square wave inputs. Input signal must be >10% of ACV range. If input is <20 mV on the 100 mV range, then the frequency must be >10 Hz. For sine wave inputs, frequency  
must be >100 Hz. For frequencies 100 Hz, threshold level 50% of input signal and 7 Hz, threshold level 3% of range.  
TEK.COM 19  
Datasheet  
Threshold Level Accuracy 89  
Accuracy (% of reading)  
2 Year, TCAL 5°C  
Threshold Range  
Threshold Resolution  
100 mV to 700 V  
0.05%  
1.0%  
Frequency and Period Characteristics  
Measurement Method  
Reciprocal counting technique.  
Aperture  
10 ms to 273 ms; default is 10 ms.  
Typical Reading Rates, 60 Hz (50 Hz) Operation 90, 91, 92, 93  
Functions:  
DC Voltage (10 V),  
2-wire Ohms (10 k),  
DC Current (1 mA)  
Functions:  
4-wire ohms (1 k),  
4-wire/3-wire RTD  
Functions:  
Thermistor  
Functions:  
Dry Circuit (1 k)  
Measurements Measurements Measurements Measurements Measurements Measurements Measurements Measurements  
NPLC  
1
Digits  
7½  
Into Buffer  
59.8 (49.8)  
295 (240)  
Into Computer  
Into Buffer  
Into Computer  
Into Buffer  
Into Computer  
Into Buffer  
Into Computer  
58 (48)  
29 (24)  
28 (24)  
57 (48)  
57 (48)  
27 (23)  
26 (22)  
0.2  
6½  
250 (210)  
128 (109)  
310 (280)  
750 (730)  
860 (860)  
119 (100)  
230 (200)  
230 (200)  
100 (89)  
96 (85)  
0.06  
0.006  
0.0005  
5½  
965 (810)  
950 (800)  
315 (280)  
740 (720)  
860 (860)  
900 (750)  
900 (750)  
190 (180)  
295 (290)  
310 (310)  
190 (180)  
295 (290)  
310 (310)  
4½  
7500 (6700)  
26000 (26000)  
7300 (6500)  
24000 (24000)  
6800 (6000)  
18000 (18000)  
6800 (6000)  
18000 (18000)  
3½  
Functions: ACV, ACI  
Measurements Measurements  
Detector  
Bandwidth (Hz)  
Digits  
6½  
Into Buffer  
Into Computer  
3
0.5 (0.5)  
0.5 (0.5)  
30  
6½  
3.3 (3.3)  
3.3 (3.3)  
300 94  
300 94  
6½  
59.8 (49.8)  
26200 (26200)  
55 (46)  
3½  
24500 (24500)  
Digitize, Typical  
Measurements Into  
Computer 93  
Sampling Rate  
10 kS/s  
Digits  
5½  
Resolution  
18  
16  
16  
15  
12  
9700  
19000  
44400  
80000  
108000  
20 kS/s  
4½  
50 kS/s  
4½  
100 kS/s  
1 MS/s  
4½  
3½  
NOTES  
89. Threshold range is voltage RMS and threshold level voltage peak. Specified with 1kHz square wave. 100V and 700V threshold ranges guaranteed by design.  
90. Reading speeds for autozero off, fixed range, autodelay off. Offset compensation off and open lead detector off where applicable.  
91. Buffer measurements: For <0.2 PLC, multisample, single buffer transfer binary reading only.  
92. PC measurements: For 1 and 0.2 PLC single reading and single transfer to computer (USB).  
93. Reading rates using factory default operating conditions and autorange off, autodelay off. Speeds include measurement and data transfer out of the USB. 1000 readings with binary  
transfer over USB.  
94. For bandwidth 300Hz, autozero off, 6½ digits at 1 PLC, 3½ digits at 0.0005 PLC.  
20 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
System Performance, Typical  
Mode  
3½-digit, autozero off, 0.0005 PLC, excludes measurement time.  
Time includes function change from DC voltage or 2-wire ohms to listed function.  
Function  
DC Voltage or 2-wire ohms (<10 k)  
4-wire ohms (<10 k)  
DC Current  
Function Change (ms)  
Range Change (ms)  
6
7
7
7
7
7
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
Frequency or Period 95  
AC Voltage or AC Current  
Digitize Voltage or Current  
Ranges for Function Change Times  
Function change times apply to the ranges listed in the table below.  
Function  
DC Voltage  
Range  
10 V  
2-wire or 4-wire Ohms  
DC Current  
1 kΩ  
1 mA  
Dry-circuit Ohms  
Thermocouple  
Thermistor  
10 Ω  
Use DC Voltage rates  
Use 2-wire Ohms rates  
1 mA  
AC Current  
AC Voltage  
1 V  
Measurements into Computer (per second)  
Buffer Transfer Speed (Binary)  
USB  
LAN  
GPIB  
Average for 1000 readings  
280000  
170000  
270000  
140000  
190000  
100000  
Average for 1000 readings with timestamp  
Triggering  
Time Base Accuracy  
25ppm.  
Trigger Source  
Analog DCV, DCI, or any system trigger.  
Trigger Coupling  
DC or AC (DCV function only).  
Input Trigger Latency 96, 97, 98  
Input Trigger Jitter 96, 97  
Sample period Jitter 96, 97  
<225 ns.  
<50 ns.  
<1 ns.  
DMM Rear-Panel Triggers  
EXT TRIG IN and OUT  
0 V to 5 V logic signal input and output, TTL compatible.  
EXT trigger latency (IN and OUT) <400 ns.  
EXT trigger latency (IN or OUT)  
<200 ns (guaranteed by design).  
NOTES  
95. For DC voltage or 2-wire ohms to frequency or period, 10ms aperture. For AC current or AC voltage, detector bandwidth is 300 Hz.  
96. Guaranteed by design; for digital I/O only.  
97. Stimulus command required to meet specifications.  
98. If using trigger model, add 200 ns uncertainty.  
TEK.COM 21  
Datasheet  
Analog Triggering 99  
Analog Level, Edge, Or Window Trigger Types100  
Trigger Characteristics  
Voltage Input  
100 mV to 1000 V  
0.05%  
Current Input  
10 µA to 10 A  
0.05%  
Input  
Resolution  
Basic Accuracy (TACAL 5°C) 101, 102  
1%  
1%  
Analog Trigger Latencies  
Digital I/O  
External  
Positive Logic  
Negative Logic  
800 ns + 40 ns jitter  
800 ns + 40 ns jitter  
930 ns + 40 ns jitter  
840 ns + 40 ns jitter  
Window Filter and Memory (buffer)  
Window Filter Size  
0 to 10% of reading, where 0 averages all readings.  
Memory  
Up to 27.5 million timestamped readings with the compact buffer style, with additional memory available  
using an external USB flash drive.  
Maximum Internal Memory (Buffer) 27.5 million readings with the compact buffer style (6½-digit without formatting), 11 million readings with  
the standard or full buffer style.  
NOTES  
99. For DC or AC coupled, the trigger level can be set up to 100% of measure range.  
100. Rising or falling edge triggering supported. Window trigger requires setting two independent levels.  
101. Trigger event occurs after the threshold crossing at a time determined by total trigger latencies.  
102. Accuracy specifications require user ACAL and are verified with level trigger amplitude set to 50% of range with a 100 Hz sine wave at 100% full scale of range. High frequency rejection is  
off. NPLC 0.0005 (DC voltage/DC current) or aperture 1 µs for digitize voltage or digitize current. Specified for fixed range, autozero off. For digitized DC voltage AC coupled, add 0.5%.  
For DC current and digitized DC current 3 A or 10 A ranges, add an additional 2%.  
General Instrument Specifications  
Specification Conditions  
This document contains specifications and supplemental information for the DMM7510 Precision Sampling  
Digital Multimeter instrument. Specifications are the standards against which the DMM7510 is tested. Upon  
leaving the factory, the DMM7510 meets these specifications. Supplemental, typical, and characteristic  
values are non-warranted, apply at 23°C, and are provided solely as useful information. All specifications  
apply to front or rear terminal inputs, except 10 A specifications (rear terminals only).  
Input Protection  
1010 V DC (715 VRMS V AC) all ranges and functions on HI and LO terminals; 350 V all ranges and functions  
on sense HI, sense LO terminals; 250 V rated current input terminal; fused 3 A and 10 A ranges; current  
input terminals protected to 1 kV.  
3 A Input Fuse Protection  
10 A Input Fuse Protection  
AC Voltage input  
Common Mode Isolation  
Power Line  
3.5 A, 1 kV fast blow type; Keithley part number DMM7510-FUSE-3A.  
11 A, 1 kV fast blow type; Keithley part number DMM7510-FUSE-10A.  
Maximum DCV: 1000V on any AC voltage range.  
500 VDC or ACVpeak LO to chassis. All terminals >10 G, <350 pF any terminal to chassis.  
Universal input, 100 V to 240 V.  
Line Frequency  
50 Hz or 60 Hz, automatically sensed at power-up.  
60 VA.  
Power Consumption  
Operating Environment  
Storage Environment  
Real Time Clock  
EMC  
Specified for 0° to 50°C, 80% relative humidity at 35°C, altitude up to 2000 meters.  
–30° to 70°C.  
Lithium battery backup (3+ years battery life).  
Conforms to European Union EMC Directive.  
Safety  
NRTL listed to UL61010-1, and CSA C22.2 No 61010-1; conforms with European Union Low  
Voltage Directive.  
22 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Vibration  
MIL-PRF-28800F Class 3, Random.  
90 minutes to rated accuracy.  
Front and rear safety banana jacks.  
Forced air, fixed speed.  
Warm-up  
Input Signal Connections  
Cooling  
Dimensions  
Without handle and bumpers: 88 mm high × 213 mm wide × 410 mm deep (3.46 in. × 8.39 in. ×  
16.13 in.).  
With handle and bumpers (bench configuration): 106 mm high × 255 mm wide × 425 mm deep (4.18 in.  
× 10.05 in. × 16.75 in.).  
Shipping weight (with bumpers and handle)  
4.08 kg (9.0 lb.).  
Shipping weight (without bumpers and handle)  
3.63 kg (8.0 lb.).  
Digital I/O:  
Connector  
9-pin female D.  
5V Power Supply Pin  
Lines  
Limited to 500 mA at > 4 V (solidstate fuse protected).  
Six input/output, user-defined, for digital I/O or triggering.  
Input Signal Levels:  
0.7 V (maximum logic low)  
3.7 V (minimum logic high).  
Input Voltage Limits:  
–0.25 V (absolute minimum)  
+5.25 V (absolute maximum).  
Maximum Source Current  
Maximum Sink Current  
Handler  
+2.0 mA at >2.7 V (per pin).  
–50 mA at 0.7 V (per pin, solid-state fuse protected).  
User-defined start of test, end of test, four category bits  
Rel, dB, Limit Test, Percentage, 1/x, and mX + b.  
Math Functions  
Remote Interface:  
LAN  
RJ-45 connector, 10/100BT; Virtual Front Panel.  
Static or DHCP.  
IP Configuration  
GPIB  
USB Device (rear panel, type B)  
IEEE-488.1 compliant. Supports IEEE-488.2 common commands and status model topology.  
2.0 full speed, USBTMC compliant.  
USB Host (front panel, type A)  
USB 2.0, support for flash drives, FAT 32.  
LXI version 1.4 Core 2011.  
LXI Compliance  
Language  
Embedded Test Script Processor (TSP) accessible from any host interface; responds to high-speed  
test scripts comprised of remote commands and statements (for example, branching, looping, math);  
able to execute high-speed test scripts stored in memory without host intervention; also SCPI (default  
command set).  
Accessories Supplied  
Accessories Available  
Product Information CD-ROM, DMM7510 Quick Start Guide, Kickstart Software Quick Start Guide, power  
cord, 1 m USB cable (type A to type B), 3 m LAN cable, and 1756 Standard Test Lead Kit.  
(Calibration / Data / ISO 17025), software IVI/VISA drivers for Microsoft® Visual Basic®, Visual C/  
C++®, National Instruments (NI™) LabVIEW™, Keithley Test Script Builder, Keithley KickStart, and NI  
LabWindows™/CVI.  
Display  
Five-inch capacitive touch, color thin-film-transistor (TFT) WVGA (800×480) with LED backlight.  
30 characters.  
Password Protection  
Expansion Interface  
The TSP-Link® expansion interface allows TSP-enabled instruments to trigger and communicate with  
each other.  
IP configuration  
Static or DHCP (manual or automatic).  
TEK.COM 23  
Datasheet  
Supplied Accessories  
1756  
Test Leads  
USB-B-1  
CA-180-3A  
USB Cable, Type A to Type B, 1 m (3.3 ft)  
TSP-Link/Ethernet Cable Documentation CD  
DMM7510 QuickStart Guide  
Test Script Builder Software (available at www.keithley.com )  
KickStart Startup Software (available at www.keithley.com)  
LabVIEW and IVI Drivers (available at www.keithley.com)  
Available Accessories  
Test Leads and Probes  
1752  
1754  
1756  
5804  
5805  
5806  
5808  
5809  
8606  
8610  
Premium Safety Test Lead Kit  
2-Wire Universal 10-Piece Test Lead Kit  
General Purpose Test Lead Kit  
Kelvin (4-Wire) Universal 10-Piece Test Lead Kit  
Kelvin (4-Wire) Spring-Loaded Probes  
Kelvin Clip Lead Set  
Low Cost Single-pin Kelvin Probe Set  
Low Cost Kelvin Clip Lead Set  
High Performance Modular Probe Kit  
Low Thermal Shorting Plug  
Replacement Fuses  
DMM7510-FUSE-10A  
DMM7510-FUSE-3A  
11 A Current Fuse For DMM7510  
3.5 A Current Fuse For DMM7510  
Cables, Connectors, Adapters  
CA-18-1  
Shielded Dual Banana Cable, 1.2 m (4 ft.)  
Communication Interfaces & Cables  
KPCI-488LPA  
KUSB-488B  
7007-1  
IEEE-488 Interface for PCI Bus  
IEEE-488 USB-to-GPIB Interface Adapter  
Shielded GPIB Cable, 1 m (3.2 ft)  
7007-2  
Shielded GPIB Cable, 2 m (6.5ft)  
CA-180-3A  
USB-B-1  
CAT5 Crossover Cable for TSP-Link / Ethernet  
USB Cable, Type A to Type B, 1 m (3.3 ft)  
Triggering and Control  
2450-TLINK  
DB-9 to Trigger Link Connector Adapter  
Trigger Link Cable, DIN-to-DIN, 1 m (3.2 ft.)  
Trigger Link Cable, DIN-to-DIN, 2 m (6.5 ft.)  
DIN-to-BNC Trigger Cable  
8501-1  
8501-2  
8503  
24 TEK.COM  
DMM 7510 7½-Digit Graphical Sampling Multimeter  
Rack Mount Kits  
4299-8  
Single Fixed Rack Mount Kit  
Dual Fixed Rack Mount Kit  
4299-9  
4299-10  
Dual Fixed Rack Mount Kit. Mount One DMM7510 and One Series 26xxB Instrument  
Dual Fixed Rack Mount Kit. Mount One DMM7510 and One Instrument from Series 2400, Series 2000, etc.  
Dual Fixed Rack Mount Kit. Mount One DMM7510 and One Keysight Instrument.  
Ears and Handle for DMM7510-NFP-RACK and DMM7510-RACK Models  
4299-11  
4299-12  
DMM7510-BenchKit  
Available Services  
Extended Warranties  
DMM7510-EW  
1 Year Factory Warranty Extended to 2 Years from Date of Shipment  
1 Year Factory Warranty Extended to 3 Years from Date of Shipment  
1 Year Factory Warranty Extended to 5 Years from Date of Shipment  
1 Year Factory Warranty Extended to 2 Years from Date of Shipment  
1 Year Factory Warranty Extended to 3 Years from Date of Shipment  
1 Year Factory Warranty Extended to 5 Years from Date of Shipment  
DMM7510-3Y-EW  
DMM7510-5Y-EW  
DMM7510-NFP-EW  
DMM7510-NFP-3Y-EW  
DMM7510-NFP-5Y-EW  
Calibration Contracts  
C/DMM7510-3Y-17025  
C/DMM7510-3Y-DATA  
C/DMM7510-3Y-STD  
KeithleyCare 3 Year ISO-17025 Calibration Plan  
KeithleyCare 3 Year Calibration w/Data Plan  
KeithleyCare 3 Year Std Calibration Plan  
KeithleyCare 5 Year ISO-17025 Calibration Plan  
KeithleyCare 5 Year Calibration w/Data Plan  
KeithleyCare 5 Year Std Calibration Plan  
KeithleyCare 3 Year ISO-17025 Calibration Plan  
KeithleyCare 3 Year Calibration w/Data Plan  
KeithleyCare 3 Year Std Calibration Plan  
KeithleyCare 5 Year ISO-17025 Calibration Plan  
KeithleyCare 5 Year Calibration w/Data Plan  
KeithleyCare 5 Year Std Calibration Plan  
Calibration Data for New Units  
C/DMM7510-5Y-17025  
C/DMM7510-5Y-DATA  
C/DMM7510-5Y-STD  
C/DMM7510-NFP-3Y-17025  
C/DMM7510-NFP-3Y-DATA  
C/DMM7510-NFP-3Y-STD  
C/DMM7510-NFP-5Y-17025  
C/DMM7510-NFP-5Y-DATA  
C/DMM7510-NFP-5Y-STD  
C/NEW DATA  
C/NEW DATA ISO  
ISO-17025 Calibration Data for New Units  
Ordering Information  
DMM7510  
7½-Digit Graphical Sampling Multimeter  
DMM7510-NFP  
DMM7510-RACK  
DMM7510-NFP-RACK  
7½-Digit Graphical Sampling Multimeter, with No Front Panel  
7½-Digit Graphical Sampling Multimeter, with No Handle  
7½-Digit Graphical Sampling Multimeter, with No Front Panel and No Handle  
TEK.COM 25  
Datasheet  
Warranty Information  
Warranty Summary  
This section summarizes the warranties of the DMM7510. For complete warranty information, refer to  
the DMM7510 Reference Manual. Any portion of the product that is not manufactured by Keithley is not  
covered by this warranty and Keithley will have no duty to enforce any other manufacturer’s warranties.  
Hardware Warranty  
Software Warranty  
Keithley Instruments, Inc. warrants the Keithley manufactured portion of the hardware for a period of one  
year from defects in materials or workmanship; provided that such defect has not been caused by use of  
the Keithley hardware which is not in accordance with the hardware instructions. The warranty does not  
apply upon any modification of Keithley hardware made by the customer or operation of the hardware  
outside the environmental specifications.  
Keithley warrants for the Keithley produced portion of the software or firmware will conform in all material  
respects with the published specifications for a period of ninety (90) days; provided the software is used on  
the product for which it is intended in accordance with the software instructions. Keithley does not warrant  
that operation of the software will be uninterrupted or error-free, or that the software will be adequate for  
the customer’s intended application. The warranty does not apply upon any modification of the software  
made by the customer.  
26 TEK.COM  
Contact Information:  
Australia* 1 800 709 465  
Austria 00800 2255 4835  
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777  
Belgium* 00800 2255 4835  
Brazil +55 (11) 3759 7627  
Canada 1 800 833 9200  
Central East Europe / Baltics +41 52 675 3777  
Central Europe / Greece +41 52 675 3777  
Denmark +45 80 88 1401  
Finland +41 52 675 3777  
France* 00800 2255 4835  
Germany* 00800 2255 4835  
Hong Kong 400 820 5835  
India 000 800 650 1835  
Indonesia 007 803 601 5249  
Italy 00800 2255 4835  
Japan 81 (3) 6714 3010  
Luxembourg +41 52 675 3777  
Malaysia 1 800 22 55835  
Mexico, Central/South America and Caribbean 52 (55) 56 04 50 90  
Middle East, Asia, and North Africa +41 52 675 3777  
The Netherlands* 00800 2255 4835  
New Zealand 0800 800 238  
Norway 800 16098  
People’s Republic of China 400 820 5835  
Philippines 1 800 1601 0077  
Poland +41 52 675 3777  
Portugal 80 08 12370  
Republic of Korea +82 2 6917 5000  
Russia / CIS +7 (495) 6647564  
Singapore 800 6011 473  
South Africa +41 52 675 3777  
Spain* 00800 2255 4835  
Sweden* 00800 2255 4835  
Switzerland* 00800 2255 4835  
Taiwan 886 (2) 2656 6688  
Thailand 1 800 011 931  
United Kingdom / Ireland* 00800 2255 4835  
USA 1 800 833 9200  
Vietnam 12060128  
* European toll-free number. If not  
accessible, call: +41 52 675 3777  
Find more valuable resources at TEK.COM  
Copyright © Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that  
in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names  
referenced are the service marks, trademarks or registered trademarks of their respective companies.  
021617.SBG 1KW-60022-2  

相关型号:

DMM7510-EW

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMM7510-NFP

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMM7510-NFP-3Y-EW

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMM7510-NFP-5Y-EW

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMM7510-NFP-EW

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMM7510-NFP-RACK

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMM7510-RACK

DMM 7510 7½-Digit Graphical Sampling Multimeter
TEKTRONIX

DMMAAP15K -F

Polyester Film Capacitors Metallized Radial Leads
CDE

DMMAAP15K-F

Polyester Film Capacitors Metallized Radial Leads
CDE

DMMAAP1K -F

Polyester Film Capacitors Metallized Radial Leads
CDE

DMMAAP1K-F

Polyester Film Capacitors Metallized Radial Leads
CDE

DMMAAP22K-F

Polyester Film Capacitors Metallized Radial Leads
CDE