TPS3000-24 [TDK]

AC-DC电源;
TPS3000-24
型号: TPS3000-24
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

AC-DC电源

文件: 总5页 (文件大小:1800K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TPS3000 Series  
https://product.tdk.com/en/power/tps  
www.emea.lambda.tdk.com/tps  
3200W 3-Phase Input Industrial Power Supplies  
The TPS3000 series industrial AC-DC power supplies offer output power up to 3,200W in a 2U high package with 3 phase supply input. Features include voltage  
and current programming, remote on/off, remote sense, a standby supply, PMBusTM communication, built in ORing FET and wide operating temperature range of  
-40°C to +70°C. The TPS3000 is also designed to meet MIL-STD-810F vibration and shock.  
Features  
Benefits  
• 400/440/480Vac (Nominal) 3 Phase Delta or Wye  
• Fully Regulated, Wide Range Voltage Adjustment  
• Voltage and Current Programming  
• -40°C (start up) to +70°C Operation  
• 92% Typical Efficiency  
• Global Use  
• Versatile Application  
• Flexible Control and Adjustment  
• Suitable for Rugged Environments  
• Less Energy Used  
• PMBusTM Communication  
• Remote Output Programming and Monitoring  
• Suitable for N + 1 Redundancy  
• Built in ORing FET for Parallel Operation  
Model Selector  
Nominal Output  
Voltage (V)  
Adjustment  
Maximum  
Current (A)  
125  
Maximum  
Power (W)  
3000  
Max  
Current (A) (2)  
133.3  
Maximum  
Power (W) (2)  
3200  
Model  
TPS3000-24  
TPS3000-48  
Range (V) (1)  
19.2 - 28.5  
38.4 - 56.5  
24  
48  
66.7  
3200  
66.7  
3200  
*Wider range adjustment as stated on the UL safety files are possible, although some parameters might not meet some of the listed specifications.  
Related Products  
Type  
Part Number  
RTMN-5020  
Description  
EMC filter  
High attenuation 20A 500Vac 3-phase input two stage filter  
Specifications  
Model  
TPF3000  
Input  
Input Voltage range  
Input Frequency  
Vac  
Hz  
A
350 - 528, Delta or Wye 3 phase (Note: Safety certified for 400-480Vac only)  
47 - 63 (Note: Safety certified for 50 to 60Hz only)  
6 per phase (steady state)  
Input Current (At nominal Vin)  
Inrush Current at 400-480Vac (Cold Start)  
Dropped Phase Power  
Leakage Current  
A
<15 per phase (excluding initial filter capacitor charging <2ms)  
Output Power 1290; output power increases with input voltage  
<3  
W
mA  
-
Power Factor (400-480Vac)  
Harmonics  
0.92 typical at rated load, nominal Vin  
Not applicable  
-
Hold Up Time (typ)  
ms  
%
-
>10 at 80% of rated current, nominal input/output voltage  
92  
Efficiency (Typical)  
Conducted & Radiated EMI  
Safety Certifications and Markings  
Voltage Dips  
EN55022 Class A, FCC part 15 Class-A  
IEC/UL/CSA/EN62368-1, 60950-1, CE Mark and UKCA  
SEMI F47-0706  
-
-
1
TPS3000 Series  
Immunity  
Test  
Standard  
Test Level  
Criteria  
B
Notes  
±8 kV air discharge,  
±4 kV contact discharge  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz)  
ESD  
EN61000-4-2  
Radiated Susceptibility  
Electrical Fast Transient Burst  
EN61000-4-3  
EN61000-4-4  
A
B
B
A
Power line pulses of ± 1 kV;  
I/O line pulses of ± 0.5 kV  
±2kV common mode,  
±1kV differential mode  
3 Vrms, 150 kHz - 80 MHz  
(80% AM at 1kHz)  
Surge  
EN61000-4-5  
EN61000-4-6  
See Immunity Data  
Conducted Susceptibility  
Inductive loop at 50 Hz  
to 1 amp (rms) per meter  
Magnetic fields  
EN61000-4-8  
A
Voltage Dips and  
Input Interruptions  
Voltage Dips of 30% and  
EN61000-4-11  
B & C  
>95%; Interruptions of >95%.  
2
TPS3000 Series  
Specifications  
Model  
TPS3000  
Output  
Line Regulation  
%
<0.25  
<0.5  
Load Regulation  
%
Total Regulation  
%
<1.75  
Warm Up Drift  
%
<0.15  
Temperature Stability  
Temperature Coefficient  
Ripple & Noise (pk-pk) (Max)  
Minimum Load  
-
0.05% of rated Vout for 8hrs after 30min warmup. Constant line, load, & temp.  
200  
ppm/°C  
mV  
A
%
%
-
24V model: 130, 48V model: 260  
0.5 minimum  
Overcurrent Protection  
Overvoltage Protection  
Overtemperature Protection  
Fan Fail  
Adjustable (70-105 of maximum rated current). Constant current style.  
115 of output voltage set point (tracking). Cycle AC or use the remote on/off to reset  
Internal thermostat. Automatic reset  
-
Blocked or fan failure detection. Cycle AC input or use PMBus to reset  
Compensates for a total of 1V cable drop  
Remote Sense  
-
Remote On/Off  
-
Enable or Inhibit (switch selectable)  
Voltage Programming  
Overcurrent Programming  
DC Good  
-
0 - 5V external voltage adjusts the output from Vout max to Vout min  
0 - 5V external voltage adjusts the current limit from Iout max to Iout min  
Open Collector, max sink current 5mA, ON when output is above 85 to 95% of output set point (tracking)  
Open Collector, max. sink current 5mA; ON when AC input is above 340Vac and unit is enabled  
Open collector, max. sink current 5mA; OFF (open) normal operation; strobing when input phase missing.  
11.2 - 12.5V, 0.3A (200mVp-p ripple and noise)  
-
-
AC Fail  
-
Dropped Phase Warning  
Standby Voltage  
-
-
Indicators  
-
Green LEDs indicates DC is OK and AC is ON. Blinking red/green during dropped phase (Load >20%)  
Single wire current share, 10% accuracy up to 8 units. Power derated 10% of rated.  
See installation manual  
Parallel Operation  
Series Operation  
Environmental  
Operating Temperature (-40°C start-up)  
-
-
°C  
-10 to +50, derate 2%/C from 50°C to 60°C, and 2.5%/C from 60 to 70  
(At <-10C a 20 min warm-up is needed)  
Storage Temperature  
Humidity (non condensing)  
Pollution Degree  
Cooling  
°C  
-40 to +85  
%RH  
10 - 90  
-
PD 2  
Internal variable speed fan  
-
m
-
Altitude  
4,000  
Withstand Voltage (For 1 minute)  
Isolation Resistance  
Vibration  
Input to Ground 2,000Vac, Input to Output 3,000Vac, Output to Ground 500Vdc  
>100 at 25°C, 70%RH  
MΩ  
-
MIL-STD-810F, Method 514.5, Proc I, Category 4, 10  
MIL-STD-810F, Method 516.5, Procedure I, IV & VI  
Shock  
-
Other  
Weight (Typ)  
g
3,700  
Size (WxHxD)  
mm  
107 x 85 x 324 (excluding output busbars)  
4.21 x 3.35 x 12.76 (excluding output busbars)  
180,000. Method 1, Ground Benign, 25C, nominal input  
3
Size (WxHxD)  
Inches  
Hours  
Years  
MTBF - Telcordia SR-332 issue 3  
Warranty  
3
TPS3000 Series  
PMBus Functions  
Derating Curve  
Output Voltage Monitoring  
Output Current Monitoring  
Internal Temperature Monitoring  
Remote On/Off Programming  
Remote Voltage Programming  
Remote Overcurrent Programming  
Fault Clearing  
Reading Manufacturing Related Data  
Notes:  
See website for detailed specifications, test methods and installation manual  
(1) A minimum load of 0.5A is required to maintain regulation and ripple spec throughout the output voltage adjustment range.  
(2) Rating at nominal output voltage only  
Outline Drawings & Pin Out  
4
TPS3000 Series  
TDK-Lambda France SAS  
TDK-Lambda Americas  
Tel: +33 1 60 12 71 65  
Tel: +1 800-LAMBDA-4 or 1-800-526-2324  
tla.powersolutions@tdk.com  
www.us.lambda.tdk.com  
tlf.fr.powersolutions@tdk.com  
www.emea.lambda.tdk.com/fr  
Italy Sales Office  
Tel: +39 02 61 29 38 63  
tlf.it.powersolutions@tdk.com  
www.emea.lambda.tdk.com/it  
TDK Electronics do Brasil Ltda  
Tel: +55 11 3289-9599  
sales.br@tdk-electronics.tdk.com  
www.tdk-electronics.tdk.com/en  
Netherlands  
tlf.nl.powersolutions@tdk.com  
www.emea.lambda.tdk.com/nl  
TDK-Lambda Germany GmbH  
Tel: +49 7841 666 0  
tlg.powersolutions@tdk.com  
TDK-Lambda Corporation  
Tel: +81-3-6778-1113  
www.jp.lambda.tdk.com  
www.emea.lambda.tdk.com/de  
TDK-Lambda (China) Electronics Co. Ltd.  
Tel: +86 21 6485-0777  
tlc.powersolutions@tdk.com  
www.lambda.tdk.com.cn  
Austria Sales Office  
Tel: +43 2256 655 84  
tlg.at.powersolutions@tdk.com  
TDK-Lambda Singapore Pte Ltd.  
Tel: +65 6251 7211  
tls.marketing@tdk.com  
www.sg.lambda.tdk.com  
www.emea.lambda.tdk.com/at  
Switzerland Sales Office  
Tel: +41 44 850 53 53  
tlg.ch.powersolutions@tdk.com  
www.emea.lambda.tdk.com/ch  
TDK India Private Limited, Power Supply Division  
Tel: +91 80 4039-0660  
mathew.philip@tdk.com  
www.sg.lambda.tdk.com  
Nordic Sales Office  
Tel: +45 8853 8086  
tlg.dk.powersolutions@tdk.com  
www.emea.lambda.tdk.com/dk  
TDK-Lambda UK Ltd.  
Tel: +44 (0) 12 71 85 66 66  
tlu.powersolutions@tdk.com  
www.emea.lambda.tdk.com/uk  
TDK-Lambda Ltd.  
Tel: +9 723 902 4333  
tli.powersolutions@tdk.com  
www.emea.lambda.tdk.com/il-en  
For Additional Information, please visit  
https://product.tdk.com/en/power/  
TPS3000_Datasheet_ 260827 April 7th, 2023 V3  
5
TPS3000 Series  

相关型号:

TPS3000-48

AC-DC电源
TDK

TPS31

Silicon Pressure Sensors
ETC

TPS3103

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS3103-EP

Ultra-Low Supply-Current/Supply-Voltage Supervisory Circuits
TI

TPS310309DVB

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310309DVBR

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310312DVB

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310312DVBR

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310315DVB

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310315DVBR

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310316DVB

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI

TPS310316DVBR

ULTRALOW SUPPLY CURRENT/SUPPLY VOLTAGE SUPERVISORY CIRCUITS
TI