SFL500-12-300-IEEE [TDK]

电子负载;
SFL500-12-300-IEEE
型号: SFL500-12-300-IEEE
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

电子负载

电子
文件: 总26页 (文件大小:4306K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SFL Series  
Programmable DC Electronic Loads  
Half-Rack 3U 300W / Full-Rack 3U 1000W  
• Stable High Speed Current Control (No Dynamic Overshoot/Oscillation) with High Slew Rate (Up to 30A/us) •  
• Low Voltage Operation with No Turn-On Delay •  
• Seven Operating Modes (CC, CR, CP, CV, EXT, Short, CV+Climit) •  
• Large 3.5" Color LCD Screen • Load Terminals on Front and Rear Panel •  
• Dynamic (Time / Frequency) Mode (Pulsating Load) • Sequence Operation (Waveform Generation) •  
• Sweep Mode Test Function (V/I, OCP, OPP) •  
• Built-In Memory Function (store/recall up to eight memory settings) •  
• Parallel Operation (up to ten units) • Multi-Channel Triggering (up to ten units) •  
• Built-In Protection & Alarms (Current Limit, Power Limit, OTP, OVP, Reverse Connection) •  
• Optional IEEE (w/DIDO) Interface • Optional Ripple Measurement Interface •  
Trusted • Innovative • Reliable  
Overall Product Description  
Overview:  
– The SFL DC Electronic Load Series is multi-functional programmable DC Electronic load series that offers power levels of 300W (3U Half Rack)  
and 1kW (3U Full-Rack) with high speed response and stable operation at low voltage and can be used as an electronic load for thedesign,  
evaluation and manufacture of regulated DC power supplies, fuel cells, solar cells, batteries and components.  
– This DC Electronic Load Series offers seven Load Operating Modes (CC, CR, CP, CV, EXT, CV+Climit) that allow the user to connect and test products  
under various different operating conditions in design/development evaluation and production testing environments.  
– There are two different Dynamic operating modes offered to the user that include Dynamic Frequency Mode (which allows the user to  
switch the load between two different settings for a single pulse or repeating pulse profile) and Dynamic Time Mode (which allows the  
user to program up to 16 load settings which can be programmed for a repeating pulse profile). Both modes also provide a rear panel TRIG  
OUT function for waveform scope viewing or for synchronization with other test equipment.  
– A Sequence function is built-in where simple/complex waveforms can be created (up to 1024 time steps) using Excel-base control software  
and Digital Interface communication (USB or IEEE) and a Sweep Mode feature is also available which allows for product testing where  
devices/products require test sweeps in CR mode (Sweep R) for V-I characteristic testing, CC mode (Sweep C) for overcurrent protection  
characteristic testing or CP (Sweep P) for overpower protection characteristic testing.  
– There is also a VModefunction that automatically changes the load mode (when voltage is rising or falling) or turns off the load input until the  
load voltage reaches a set value, on-board memory for storage/recall of up to eight operational settings and a rear panel Remote Sense  
selection switch and connection ports for connection and voltage measurement across the test device.  
– Model functions can be set up via the large 3.5” color LCD front panel display (which has oscilloscope-like function keys on the vertical and  
horizontal borders). Change second sentence: Using these keys in combination with the four embedded operationg screens (MAIN, MENU,  
SYSTEM and MEMORY) allows for adjustment, setup, store and recall of the load operating parameters. These model functions are also  
accessible via the built-in USB interface or the optional IEEE Interface.  
– Higher power DC load systems (of up to 10kW) are achievable using a Master-Slave unit arrangement and a simple parallel cable connection  
from unit-to-unit, with all system control and monitor performed through the Master unit (for easy user interfacing).  
– Multi-channel synchronous operation (with triggering) is also available and allows multiple DC electronic loads to be connected to separate  
devices by using the same parallel cable connection from unit-to-unit. Synchronized load ON/OFF and Dynamic operation are featured in a  
Master-Slave configuration with up to ten units total (up to 10kW total).  
– Optional interfaces offered include the IEEE Interface (with a built-in DIDO Interface) and the Ripple Measurement Module (R) Interface.  
The IEEE Interface is 488.1 compliant with Instrument Software Drivers available for use. TheDIDO Interface allows for remote interfacing with PLC  
controllers and includes isolated control and status of load ON/OFF, Range setting, Alarm Detection/Clear and Sweep Function Pass/Fail status.  
– The  
R (Ripple Measurement) Interface is used for measuring Output voltage ripple and noise and can separate and measure and display line  
frequency, switching voltage or noise voltage ripple (with 100MHz or 20MHz bandwidth) using the Filter function and can also measure and  
display the DC voltage, Power or combined DC and ripple/noise voltage added.  
– Models are available in 300W and 1000W power levels with Output voltages of 120V (60A and 180A) and 500V (18A and 36A)  
and are powered from a universal single-phase AC input (85~264VAC, 47~63Hz).  
Key Features:  
Low and High Load Power Rating::  
Parallel Operation:  
up to 10kW (ten units)  
Half-Rack 300W and Full-Rack 1kW power levels  
Low and High Load Voltage Rating::  
120V (60A or 180A) and 500V (12A or 36A)  
Multi-Channel Synchronous Operation:  
For separate synchronized unit operation (up to ten units)  
Seven Load Operating Modes: CC, CR, CP, CV, EXT, Short, CV+Climit  
Large 3.5” color LCD multi-functional viewing screen  
Stable High Speed Current Control  
(No Dynamic Overshoot/Oscillation)  
Load Terminals: Front and back of unit (w/ terminal  
covers). Binding posts on 300W model front panel.  
Low Voltage Operation with No Turn-On Delay  
Built-In USB Interface  
Optional IEEE Interface  
(w/ DIDO built-in for PLC interfacing)  
Variable Slew Rate Control: Up to 30A/us  
Dynamic (Frequency or Time) Mode Operation:  
For simple pulse profile operation  
Optional R (Ripple Measurement) Interface  
(for Output voltage ripple measurements)  
Sequence Mode: For complex waveform generation  
GUI and Software Instrument Drivers available  
Sweep Mode Test Function w/ Display: V-I Test, Over-Current Test,  
Over-Power Test  
Complies with to IEC/EN 61010-1, Ed. 3  
VMode Function: to set load rising/falling profile  
Memory Function Built-In: store/recall up to eight load settings  
Protection/Alarms: Current Limit, Power Limit, OTP, OVP, Reverse Connection  
Complies with EN61326-1: 2013 (Class A)  
Two Year Warranty  
2 | SFL DC ELECTRONIC LOAD SERIES  
Front View: Key Features (300W Model)  
13  
14  
2
3
1
4
5
6
7
8
11  
12  
10  
9
Item  
Title  
Description  
1
2
3
Display  
Function keys  
MODIFY knob  
Large 3.5" Color LCD display that shows set value, measurement value, etc.  
Allows the user to select items from the Horizontal and Vertical menus  
Continuous rotary knob that increases or decreases a setpoint value  
Up/Down Keys: Angled pushbutton keys that increase or decrease a setpoint value  
Left/Right Keys: Angled pushbutton keys that select decimal place location  
4
CURSOR keys  
Returns to the previous operating screen (eg. MENU screen to MAIN screen).  
Allows the user to re-enter data  
5
CANCEL key  
Cancels Remote mode operation (IEEE, USB) and goes to Front Panel Local operation  
Clears the OVP/Reverse Connection ALARM  
Stops SEQUENCE operation  
6
7
8
ENTER key  
ON/OFF button  
MENU key  
Pressed to fix an entered numeric value from keypad (eg. load value) or other selection (eg. SYSTEM reset)  
Turns Load Output ON/OFF; lit GREEN when ON; unlit when OFF  
Pressing enters into MENU screen or returns to MAIN screen.  
Pressing switches between Standby and Startup state  
MAIN screen will appear after startup screen and Firmware Version screen  
Type B connector, USB 2.0 compliant interface (USBTMC) for controlling the unit remotely  
Pressing enters into MEMORY screen or returns to MAIN screen  
Front Panel Positive and Negative Binding Post terminals for connection to the Device-Under-Test  
Internally connected to the Rear Panel Positive and Negative load terminals  
Binding Post terminals for the SFL 300W models only  
9
STANDBY switch  
10 USB connector  
11 MEMORY key  
12 LOAD terminals  
13 Air Intake slots  
14 Product Label  
Air inlets for product cooling  
Label that identifies product information (Product Series, Voltage/Current/Power, etc.)  
SFL DC ELECTRONIC LOAD SERIES | 3  
Rear View: Key Features (300W Model)  
12  
15  
1
2
3
10  
13  
9
4
5
6
8
14  
7
11  
Item  
Title  
Description  
Connects the optional MASTER/SLAVE connection cable from Master (OUT) to Slave (IN)  
Used during parallel operation only or Multi-Channel Synchronous operation  
MASTER/SLAVE terminals referenced to minus load terminal  
Trigger signal output  
1
MASTER/SLAVE IN/OUT connectors  
Used as the trigger signal when observing the load waveform in Dynamic mode with a scope or when  
synchronizing with other devices  
TRIG OUT referenced to Case potential  
Input pins for EXTernal voltage control (Load current proportional to Control Voltage)  
Control voltage range: 0V to 10V  
2
3
TRIG OUT +/- pins  
EXTernal Control Input (EXT-IN +/- pins)  
EXT-IN terminals referenced to minus load terminal  
For connecting remote sense cable  
4
5
6
Remote Sense Input (SENSE +/- pins)  
EXT/INT Switch  
Remote Sense is enabled when the SENSE selection switch is set to EXT  
SENSE terminals referenced to minus load terminal  
Switch for selecting voltage sense signal  
Set to EXT when using remote sense cable  
Signal is used when monitoring load current waveform with oscilloscope  
Analog voltage proportional to load current (dependent on Load Current Range)  
Current Monitor terminals referenced to minus load terminal  
Rear panel load busbars (with mounting hardware) for connection to the Device-Under-Test  
Internally connected to the Front Panel Positive and Negative load terminals  
Busbars with M6 (300W)/M8 (1000W) diameter hole  
Current Output Monitor (IMON)  
7
LOAD terminals  
For connecting AC power cord between AC service and SFL DC Electronic Load  
North American or European AC Input linecord available  
Single-phase, 85~264VAC, 48-62Hz; 60VA max (300W models)/65VA max (1000W models)  
AC Input Main Power switch; Switch depressed to I = ON, depressed to O = OFF  
8
9
AC Power Inlet  
AC POWER Switch  
Optional interface that adds measurement function equivalent to ripple noise measurement using 100MHz  
oscilloscope recommended by JEITA standard  
Spiked switching noise and line frequency can be separated and measured  
Variation found in measurement using oscilloscope can be avoided and measurement time can be reduced  
Ripple Measurement terminals referenced to minus load terminal  
Used for heated air exhaust ventilation  
10  
Ripple Measurement Interface  
11  
12  
Air Outlet slots  
Port for optional communication Interface  
Optional Interface port  
IEEE Interface with separate DIDO Digital Control Interface  
DIDO Digital Control used for external control and status monitoring  
Label describing Model # and Serial #  
Label indicating product CE mark compliance  
Label indicating product RoHS compliance  
13  
14  
15  
Serial Number Label  
CE Mark label  
RoHS label  
4 | SFL DC ELECTRONIC LOAD SERIES  
Front Panel Display: Key Features (1000W Model)  
14  
2
3
13  
1
4
5
6
7
8
12  
11  
10  
9
Item  
Title  
Description  
1
2
3
Display  
Large 3.5" Color LCD display that shows set value, measurement value, etc.  
Allows the user to select items from the Horizontal and Vertical menus  
Continuous rotary knob that increases or decreases a setpoint value  
FUNCTION Keys  
MODIFY knob  
Up/Down Keys: Angled pushbutton keys that increase or decrease a setpoint value  
Left/Right Keys: Angled pushbutton keys that select decimal place location  
Returns to the previous operating screen (eg. MENU screen to MAIN screen)  
Allows the user to re-enter data  
Cancels Remote mode operation (IEEE, USB) and goes to Front Panel Local operation  
Clears the OVP/Reverse Connection ALARM  
Stops SEQUENCE operation  
Pressed to fix an entered numeric value from keypad (eg. load value)  
or other selection (eg. SYSTEM reset)  
4
5
6
CURSOR keys  
CANCEL key  
ENTER key  
7
8
ON/OFF button  
MENU key  
Turns Load Output ON/OFF; lit GREEN when ON; unlit when OFF  
Pressing enters into MENU screen or returns to MAIN screen  
Pressing switches between Standby and Startup state  
MAIN screen will appear after startup screen and Firmware Version screen  
Type B connector, USB 2.0 compliant interface (USBTMC) for controlling the unit remotely  
Pressing enters into MEMORY screen or returns to MAIN screen  
Front Panel Positive and Negative busbars for connection to the Device-Under-Test  
Internally connected to the Rear Panel Positive and Negative busbars  
Busbar terminals used for the SFL 1000W models  
9
STANDBY switch  
10  
11  
USB connector  
MEMORY key  
12  
LOAD terminals  
13  
14  
Air Intake slots  
Product Label  
Air inlets for product cooling  
Label that identifies product information (Product Series, Voltage/Current/Power, etc.)  
SFL DC ELECTRONIC LOAD SERIES | 5  
Rear View: Key Features (1000W Model)  
12  
1
2
3
4
15  
10  
13  
9
5
6
8
14  
11  
7
Item  
Title  
Description  
Connects the optional MASTER/SLAVE connection cable from Master (OUT) to Slave (IN)  
Used during parallel operation only or Multi-Channel Synchronous operation  
MASTER/SLAVE terminals referenced to minus load terminal  
Trigger signal output  
1
MASTER/SLAVE IN/OUT connectors  
Used as the trigger signal when observing the load waveform in Dynamic mode with a scope or when  
synchronizing with other devices  
TRIG OUT referenced to Case potential  
Input pins for EXTernal voltage control (Load current proportional to Control Voltage)  
Control voltage range: 0V to 10V  
2
3
TRIG OUT +/- pins  
EXTernal Control Input (EXT-IN +/- pins)  
EXT-IN terminals referenced to minus load terminal  
For connecting remote sense cable  
4
5
6
Remote Sense Input (SENSE +/- pins)  
EXT/INT Switch  
Remote Sense is enabled when the SENSE selection switch is set to EXT  
SENSE terminals referenced to minus load terminal  
Switch for selecting voltage sense signal  
Set to EXT when using remote sense cable  
Signal is used when monitoring load current waveform with oscilloscope  
Analog voltage proportional to load current (dependent on Load Current Range)  
Current Monitor terminals referenced to minus load terminal  
Rear panel load busbars (with mounting hardware) for connection to the Device-Under-Test  
Internally connected to the Front Panel Positive and Negative load terminals  
Busbars with M6 (300W)/M8 (1000W) diameter hole  
Current Output Monitor (IMON)  
7
LOAD terminals  
For connecting AC power cord between AC service and SFL DC Electronic Load  
North American or European AC Input linecord available  
Single-phase, 85~264VAC, 48-62Hz; 60VA max (300W models)/65VA max (1000W models)  
AC Input Main Power switch; Switch depressed to I = ON, depressed to O = OFF  
8
9
AC Power Inlet  
AC POWER Switch  
Optional interface that adds measurement function equivalent to ripple noise measurement using 100MHz  
oscilloscope recommended by JEITA standard  
Spiked switching noise and line frequency can be separated and measured  
Variation found in measurement using oscilloscope can be avoided and measurement time can be reduced  
Ripple Measurement terminals referenced to minus load terminal  
Used for heated air exhaust ventilation  
10  
Ripple Measurement Interface  
11  
12  
Air Outlet slots  
Port for optional communication Interface  
Optional Interface port  
IEEE Interface with separate DIDO Digital Control Interface  
DIDO Digital Control used for external control and status monitoring  
Label describing Model # and Serial #  
Label indicating product CE mark compliance  
Label indicating product RoHS compliance  
13  
14  
15  
Serial Number Label  
CE Mark label  
RoHS label  
6 | SFL DC ELECTRONIC LOAD SERIES  
Front Panel Display: Key Features (300W/1000W Models)  
9
1
2
3
8
6
5
4
7
Item  
1
Title  
Description  
Displays detailed settings for a menu item selected on the Horizontal menu  
Fix by selecting the item using Vertical FUNCTION key(s)  
Vertical Menu*  
2
3
4
Set Value (Voltage Range): Displays the set value of the Voltage range (H/L)  
Set Value (Current Range): Displays the set value of the Current range (H/M/L)  
Set Value (SlewRate): Displays the set value of the Slew Rate  
Set Value (Load): Displays the set value of the load  
5
6
Digits to be set are displayed in reverse contrasting colors  
Set Value*  
Set Value (Load Mode)  
CC: Constant-Current mode  
CR: Constant-Resistance mode  
CV: Constant-Voltage mode  
CP: Constant-Power mode  
EX: External Control Mode (CC)  
ST: Short Mode  
7
8
9
Horizontal Menu*  
Status Display  
Basic setting menu of items displayed on the screen  
Operating Mode, VMode, Master, OCP, OPP  
Measured Value  
Measured values of Voltage, Current and Power. Display order can be changed.  
* Vertical menu, Horizontal menu and Set Values displayed on the screen vary according to operting mode or other settings.  
The figure above is an example of the Normal operating mode.  
SFL DC ELECTRONIC LOAD SERIES | 7  
Features  
Operating Modes / Load Modes  
The SFL DC Electronic Load Series has seven different load operating modes (CC, CR, CV, CP, EXT, SHORT and CV + Climit) with four  
different operating modes (Normal, Dynamic, Sequence and Sweep) that allows the user to perform a variety (up to seventeen)  
different types of load tests for DC power supplies, fuel cells, solar cells, batteries and components.  
Load Mode  
CV  
CV + Climit  
CC  
CR  
CP  
EXT  
SHORT  
Normal  
Dynamic  
Sequence*  
Sweep  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
* Sequence Mode uses USB (or IEEE) Interface  
Dynamic Overshoot/Oscillation Eliminated  
Standard electronic loads may generate load current overshoot and oscillation (during some operating conditions) which can damage  
connected devices.The SFL Series incorporates high-speed current feedback control to eliminate load current overshoot and oscillation  
to realize a stable and predictable load waveform during turn-On or Dynamic operation.  
No overshoot  
Current  
No turn-On overshoot  
(DUT Turn-On with Load ON)  
No overshoot  
Current  
Voltage  
Dynamic Load Change  
(No overshoot)  
8 | SFL DC ELECTRONIC LOAD SERIES  
Features  
Low Voltage Operation / Rising Load Current Without Turn-On Delay  
Some electronic loads may have discontinuity and not allow load current to flow below a minimum operating voltage. Due  
to low voltage operating optimization the SFL DC Electronic Load Series is able to emulate a resistor where the load current  
flows and changes linearly from 0V thereby eliminating current cut-off at low operating voltage. This also eliminates any  
soft-start delay (where load current does not flow until a minimum operating voltage is achieved) and allows low voltage  
devices to be properly tested.  
Current  
Voltage  
Low Voltage Operation  
with Start-Up from 0V  
Parallel Operation  
Parallel operation (via rear panel connection) is achieved by connecting units of the same voltage rating in parallel, connecting  
a parallel cable from unit-to-unit and setting one unit as the Master unit and all other units as Slave units. Up to nine Slave  
units can be connected in a system allowing load systems of up to 10kW to be configured.  
Load system control is performed by the Master unit where total load system current or power can be set up and displayed  
on the Master unit front panel.  
Master  
Slave  
Slave  
(Up to 9)  
SFL DC ELECTRONIC LOAD SERIES | 9  
Features  
Multi-Channel Synchronous Operation  
Multi-channel synchronous operation (with triggering) allows multiple DC electronic loads to be connected to separate devices by  
using the same parallel cable connection from unit-to-unit. Synchronized load ON/OFF and Dynamic operation are featured in a  
Master-Slave configuration with up to ten units total (up to 10kW total).  
Master  
Master  
CH-1  
Slave  
Slave  
Slave  
CH-2  
CH-3  
SMPS  
Slave  
(Up to 9)  
Multiple Device-Under-Test Setup  
Protection Functions and Alarms  
Single Device-Under-Test Setup (Multi-Output)  
Several Protection functions and Alarms are featured including Current Limit (OCP), Power Limit (OPP), Over-Temperature protection  
(OTP), Over-Voltage protection (OVP) Alarm and Reverse Connection Alarm.  
The Current Limit (OCP) has an adjustable limit threshold where the load can be set to either maintain operation at the limit threshold  
or shut down where the Power Limit (OPP) is set to 100% of rated power and can maintain load operation at the limit threshold or  
shut down.  
Protection  
OCP  
OPP  
OVP (1)  
Fixed  
N/A  
OTP  
Fixed  
N/A  
Reverse Connection (1)  
Fixed  
Threshold Limit Adjust  
Operation at Threshold Limit  
Load Shutdown  
(110% rating)  
N/A  
N/A  
Load Current Cutoff  
Audible Beep  
Display Alarm  
(1) Remove fault condition from load or load may be damaged  
10 | SFL DC ELECTRONIC LOAD SERIES  
How To Order  
SFL DC Electronic Load Series  
How to Order - Identification / Accessories  
300W Models  
SFL  
120  
-
60  
-
-
300  
-
-
IEEE  
IEEE  
-
-
R
R
Load  
Voltage  
Load  
Current  
Load  
Power  
Series Name  
(0-120V)  
(0-60A)  
(0-300W)  
1000W Models  
SFL  
500  
-
36  
1K  
Load  
Voltage  
Load  
Current  
Load  
Power  
Series Name  
(0-500V)  
(0-36A)  
(0-1000W)  
Programming Interface Options  
P/N  
P/N  
IEEE Interface (488.1 & SCPI compliant)  
IEEE  
---  
Test Interface Options  
P/N  
P/N  
R (Ripple Measurement) Interface  
---  
R
Models (300W)  
Model  
Load Voltage (V)  
Load Current (A)  
Load Power (W)  
SFL 120-60-300  
SFL 500-12-300  
120  
500  
60  
12  
300  
300  
Models (1000W)  
Model  
Load Voltage (V)  
Load Current (A)  
Load Power (W)  
SFL 120-180-1K  
SFL 500-36-1K  
120  
500  
180  
36  
1000  
1000  
Accessories  
Included or Sold Separately  
Master/Slave Connection Cable  
1
P/N: Contact Factory  
P/N: SFL-CBL-IMON  
-----  
Cable used for Parallel Operation of Multiple Units  
Current Monitor (IMON) Cable  
Cable used for IMON analog signal measurement  
2
Sold separately  
Sold separately  
Sold separately  
EIA Rack-Mount Kit  
3 Rack-Mount Kit for SFL-300  
(Single/Dual)/SFL-1000 (Single)  
P/N: SFL-KIT-RM-EIA  
P/N: SFL-RM-BP  
Blank Panel, EIA Rack-Mount  
Blank Panel for Single Unit Rack-Mounting (SFL-300)  
4
Test Data Sheet - Standard w/Calibration Certificate  
5 Test Data Sheet - Standard with Calibration Certificate  
and Traceability  
P/N: SFL-TR-STD-CAL/TR  
Sold separately  
SFL DC ELECTRONIC LOAD SERIES | 11  
Technical Specifications - SFL DC Electronic Load Series  
LOAD CHARACTERISTICS  
Ratings  
120-60-300  
500-12-300  
120-180-1K  
120  
500-36-1K  
500  
V
A
120  
60  
500  
12  
Voltage  
180  
36  
Current  
W
300  
300  
1000  
1000  
Power, (*1)  
mΩ  
18 or less  
100 or less  
6 or less  
33.3 or less  
Internal Minimum Resistance, (*2)  
1.08V (60A) / 0.54V (30A)  
1.2V (12A) / 0.6V (6A)  
1.08V (180A) / 0.54V (90A  
1.2V (36A) / 0.6V (18A)  
---  
Load Range, (*2) (*3)  
/ 0.22V (12A)  
/ 0.28V (2.8A)  
/ 0.22V (36A)  
/ 0.28V (8.4A)  
I
I
I
I
12A  
60A  
180A  
36A  
300W  
300W  
1000W  
1000W  
Load Range curves  
V
V
1.2 V (12 A) / 0.6 V (6 A) / 0.28 V (2.8 A)  
1.08 V (60 A)  
/
0.54 V (30 A) / 0.22 V (12 A)  
3V  
500V  
V
1V  
120V  
V
1.08 V (180 A) / 0.54 V (90 A) / 0.22V (36 A)  
1V  
120V  
1.2 V (36 A) / 0.6 V (18 A) / 0.28 V (8.4 A)  
3V  
500V  
Operating Mode  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Normal Mode (Constant Load)  
---  
---  
---  
---  
---  
Constant Current (CC) mode: Constant current will flow even if the load terminal voltage is changed  
Constant Resistance (CR) mode: Current proportional to load terminal voltage will flow (resistive load)  
Constant Voltage (CV) mode: Load terminal voltage remains constant even when load current varies  
Constant Power (CP) mode: Current will flow such that load power remains constant  
Load Modes  
External Control (EXT) mode: Load current proportional to voltage of external control input terminal will flow  
Short (SHORT) mode: Creates short circuit between load terminals -up to rated current flows or 100% of  
Current Limit set value  
---  
Dynamic Mode - Frequency (Fluctuating Load)  
Frequency: Allows setting waveform Period and Duty Cycle and repeated switching between two load  
---  
Type  
settings. slew Rate is set for each step individually.  
See User's Manual for more information  
---  
---  
Load Modes  
CC / CR / CV/ CP  
1us < Period < 2ms (1us resolution) / 20ms < Period < 200ms (10us resolution) /  
200ms < Period < 2s (100us resolution) / 2s < Period < 10s (1ms resolution)  
Period Setting/Resolution  
%
---  
Duty Cycle Setting  
Operation  
0% to 100%  
Single (single waveform) or repeat (repeating waveform); TRIGGER OUT feature available  
Dynamic Mode - Time (Fluctuating Load)  
Time: Allows setting Time by Step and sequential/repeated switching of up to 16 types of loads conditions.  
---  
---  
---  
---  
Type  
See User's Manual for more information  
Load Modes  
Execution Time  
CC / CR / CV/ CP  
1us < T < 20ms (1us resolution) / 20ms < T < 200ms (10us resolution) / 200ms < T < 2s (100us resolution) /  
2s < T < 20s (1ms resolution) / 20s < T < 60s (10ms resolution)  
Repeat; TRIGGER OUT feature available  
Operation  
Sweep Mode  
Sweep R (V-I Characteristic Test), Sweep C (Overcurrent Characteristic Test), Sweep P (Overpower  
Characteristic Test)  
Current and voltage values are measured while changing the load in a step-wise manner (in CR mode).  
Resistance value can be finely changed between steps. Measurement values are shown as a graph on front  
panel display.  
---  
---  
Type  
Sweep R (V-I Characteristic Test)  
Current and voltage values are measured while changing the load in a step-wise manner (in CC mode). Upper/  
Lower limts of current value can be set (with PASS/FAIL decision function). Measurement values are shown as a  
graph on front panel display.  
Power and voltage values are measured while changing the load in a step-wise manner (in CP mode).  
Upper/Lower limts of power value can be set (with PASS/FAIL decision function). Measurement values shown  
as a graph on front panel display.  
---  
---  
Sweep C (Overcurrent Characteristic Test)  
Sweep P (Overpower Characteristic Test)  
Sequence Operation (Remote Digital Mode Only - IEEE or USB)  
---  
---  
---  
---  
---  
---  
---  
---  
Type  
Load Modes  
Allows user to program a load waveform profile  
CC, CR, CV, CP  
1 - 1024  
1ms - 10minutes (common to all steps)  
1ms (1ms to 100ms) / 100ms (100ms - 10minutes)  
1 to 65535 (finite) or ∞  
IEEE or USB Interface only; Waveform termination via IEEE, USB or CANCEL key of front panel display  
Triangle, Sine or Arc  
Number of Steps  
Step Time  
Step Time Resolution  
Sequence Repetitions  
Control Method  
Waveforms available  
12 | SFL DC ELECTRONIC LOAD SERIES  
Technical Specifications - SFL DC Electronic Load Series  
LOAD CHARACTERISTICS  
Load Modes  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Constant Current (CC) Mode  
Current  
Range  
---  
---  
---  
---  
---  
H
M
L
H
M
L
A
A
A
mA  
mA  
mA  
0 - 60A  
0 - 6A  
0 - 0.6A  
5mA  
0.5mA  
0.1mA  
0 - 12A  
0 - 1.2A  
0 - 0.12A  
1mA  
0.1mA  
0.02mA  
0 - 180A  
0 - 18A  
0 - 1.8A  
15mA  
1.5mA  
0.3mA  
0 - 36A  
0 - 3.6A  
0 - 0.36A  
3mA  
0.3mA  
0.06mA  
Current Setting Range  
Current Setting Resolution  
+/- (0.2% of setpoint  
+25mA+Vin/50KΩ)  
+/- (0.2% of setpoint  
+12mA+Vin/50KΩ)  
+/- (0.2% of setpoint  
+6mA+Vin/50KΩ)  
+/- (0.2% of setpoint  
+10mA+Vin/750KΩ)  
+/- (0.2% of setpoint  
+3mA+Vin/750KΩ)  
+/- (0.2% of setpoint  
+2mA+Vin/750KΩ)  
+/- (0.2% of setpoint  
+75mA+Vin/16.67KΩ)  
+/- (0.2% of setpoint  
+36mA+Vin/16.67KΩ)  
+/- (0.2% of setpoint  
+18mA+Vin/16.67KΩ)  
+/- (0.2% of setpoint  
+30mA+Vin/250KΩ)  
+/- (0.2% of setpoint  
+9mA+Vin/250KΩ)  
+/- (0.2% of setpoint  
+6mA+Vin/250KΩ)  
H
M
L
---  
---  
---  
Current Setting Accuracy, (*4)  
H
M
L
A/us  
A/us  
A/us  
0.2 - 20A/us  
0.02 - 2A/us  
0.005 - 0.5A/us  
0.01 - 1A/us  
0.001 - 0.1A/us  
0.00025 - 0.025A/us  
0.3 - 30A/us  
0.03 - 3A/us  
0.0075 - 0.75A/us  
0.03 - 3A/us  
0.003 - 0.3A/us  
0.00075 - 0.075A/us  
Slew Rate (Current Range), (*5)  
Constant Resistance (CR) Mode  
Current  
Range  
---  
S
L (20V)  
L (85V)  
L (20V)  
L (85V)  
40.000S - 0.0005S  
(0.025Ω - 200Ω)  
4.000S - 0.0005S  
(0.25Ω - 2kΩ)  
3.3333S - 0.0004S  
(0.3Ω - 2.5kΩ)  
120.00S - 0.01S  
(0.0083Ω - 66.667Ω)  
12.000S - 0.001S  
10.0000S - 0.001S  
(0.1Ω - 833.33Ω)  
1.0000S - 0.0001S  
(1Ω - 8333.3Ω)  
H
Resistance Setting Range  
0.3333S - 0.00004S  
M
S
(3Ω - 25kΩ)  
(0.0833Ω - 666.67Ω)  
H
M
---  
uS (or mS)  
uS (or mS)  
---  
4mS  
400uS  
333uS  
33uS  
12mS  
1.2mS  
1mS  
0.1mS  
Resistance Setting Resolution  
H (120V)  
H (500V)  
H (120V)  
H (500V)  
13.333S - 0.0016S  
1.111S - 0.0001S  
40.000S - 0.005S  
3.3333S - 0.0004S  
H
S
S
(0.075Ω - 600Ω)  
(0.9Ω - 7kΩ)  
(0.025Ω - 200Ω)  
(0.3Ω - 2.3333kΩ)  
Resistance Setting Range  
1.333S - 0.00016S  
(0.75Ω - 6kΩ)  
0.11111S - 0.00001S  
(9Ω - 70kΩ)  
4.0000S - 0.0005S  
(0.25Ω - 2kΩ)  
0.33330S - 0.00004S  
(3Ω - 23.333Ω)  
M
H
M
us/mS  
uS/mS  
1.33mS  
133uS  
111uS  
11uS  
3.99mS  
399uS  
333uS  
33uS  
Resistance Setting Resolution  
+/- (0.5% of Vin/Set  
+/- (0.5% of Vin/Set  
+/- (0.5% of Vin/Set  
+/- (0.5% of Vin/Set  
Resistance +0.2% of FS +  
Vin/250kΩ)  
---  
---  
Resistance + 0.2% of FS + Resistance + 0.2% of FS + Resistance +0.2% of FS +  
Setting Accuracy, (*4) (*6) (*7)  
Vin/50kΩ)  
Vin/750kΩ)  
Vin/16.67kΩ)  
Constant Voltage (CV) Mode  
H
L
H
L
---  
---  
V
V
mV  
mV  
---  
---  
0 - 120V  
0 - 20V  
10mV  
2mV  
0 - 500V  
0 - 85V  
50mV  
0 - 120V  
0 - 20V  
10mV  
2mV  
0 - 500V  
0 - 85V  
50mV  
Voltage Setting Range  
Voltage Setting Resolution  
10mV  
10mV  
+/- (0.1% of setting +0.1% of FS)  
Fast / Slow  
Voltage Setting Accuracy, (*4)  
Response Time  
Constant Power (CP) Mode  
H
M
H
W
W
mW  
mW  
0 - 300W  
0 - 40W  
50mW  
5mW  
0 - 300W  
0 - 40W  
50mW  
5mW  
0 - 1000W  
0 - 120W  
167mW  
0 - 1000W  
0 - 120W  
167mW  
Power Setting Range  
Power Setting Resolution  
M
16.7mW  
16.7mW  
+/- (0.6% of setting + 1.4% +/- (0.6% of setting + 1.4% +/- (0.6% of setting + 1.4% +/- (0.6% of setting + 1.4%  
---  
---  
Power Setting Accuracy, (*4)(*7)  
External Control (EXT) Mode  
Current Setting Range  
of FS + (Vin*Vin)/50kΩ)  
of FS + (Vin*Vin)/750kΩ) of FS + (Vin*Vin)/16.67kΩ) of FS + (Vin*Vin)/250kΩ)  
H
M
H
A
A
mA  
mA  
0 - 60A  
0 - 6A  
5mA  
0 - 12A  
0 - 1.2A  
1mA  
0 - 180A  
0 - 18A  
15mA  
0 - 36A  
0 - 3.6A  
3mA  
Current Setting Resolution  
M
0.5mA  
0.1mA  
1.5mA  
0.3mA  
+/- ( 0.2% of setting + 0.5% +/- ( 0.2% of setting + 0.5% +/- ( 0.2% of setting + 0.5% +/- ( 0.2% of setting + 0.5%  
H
---  
Current Setting Accuracy, (*4), (*8)  
Slew Rate (Current Range), (*5)  
of FS + (Vin/50kΩ))  
0.2 - 20A/us  
of FS + (Vin/750kΩ))  
0.01 - 1A/us  
of FS + (Vin/16.67kΩ) )  
0.3 - 30A/us  
of FS + (Vin/250kΩ))  
0.03 - 3A/us  
H
M
A/us  
A/us  
V
0.02 - 2A/us  
0.001 - 0.1A/us  
0.03 - 3A/us  
0.003 - 0.3A/us  
Control Voltage  
0 - 10V  
Short (SHORT) Mode  
H
H
A
A
60A  
12A  
180A  
36A  
Short Mode Current (max value), (*9)  
Short Mode Current (max value w/  
Current Limit Set)  
110% of Current Limit Value (when Current Limit is set)  
SFL DC ELECTRONIC LOAD SERIES | 13  
Technical Specifications - SFL DC Electronic Load Series  
MEASUREMENT CHARACTERISTICS (FP Display)  
DC Voltage Measurement (FP Display)  
120-60-300  
---  
0V to 120V  
0V to 20V  
10mV  
500-12-300  
---  
0V to 500V  
0V to 85V  
10mV  
120-180-1K  
---  
0V - 120V  
0V to 20V  
10mV  
500-36-1K  
---  
0V - 500V  
0V to 85V  
10mV  
---  
---  
V
V
mV  
mV  
---  
ms  
H
L
Voltage Measurement Range, (*10)  
H
L
Voltage Measurement Resolution  
1mV  
1mV  
1mV  
1mV  
---  
---  
+/- (0.05% of reading + 0.5% of FS)  
approximately 100ms  
Voltage Measurement Accuracy, (*4)  
Measurement Time, (*11)  
DC Current Measurement (FP Display)  
120-60-300  
0 - 60A  
500-12-300  
120-180-1K  
0 - 180A  
0 - 18A  
500-36-1K  
0 - 36A  
0 - 3.6A  
0 - 0.36A  
1.5mA  
H
A
A
A
mA  
mA  
mA  
---  
---  
---  
ms  
0 - 12A  
0 - 1.2A  
0 - 0.12A  
0.5mA  
M
L
0 - 6A  
0 - 0.6A  
0.5mA  
0.1mA  
0.1mA  
Current Measurement Range, (*12)  
0 - 1.8A  
1.5mA  
0.3mA  
0.3mA  
H
M
L
0.1mA  
0.1mA  
0.3mA  
0.3mA  
Current Measurement Resolution  
H
M
L
+/- (0.2% of reading + 0.2% of FS)  
+/- (0.2% of reading + 0.2% of FS)  
+/- (0.2% of reading + 0.5% of FS)  
approximately 100ms  
Current Measurement Accuracy, (*4)  
Measurement Time, (*11)  
---  
Power Measurement (FP Display)  
Power Measurement Method  
Measurement Time, (*11)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
---  
---  
---  
ms  
by calculation (Measured voltage x Measured current)  
approximately 200ms  
PROTECTIVE FUNCTIONS (Protection and Alarms)  
Current Limit Protection (OCP/Climit)  
120-60-300  
500-12-300  
120-180-1K  
---  
500-36-1K  
---  
Current  
---  
---  
---  
Range  
H, M, L  
A
A
mA  
mA  
---  
0 - 60A  
0 - 12A  
0 - 180A  
0 - 36A  
Current Setting Range  
Current Setting Resolution  
Load Modes  
H
M
L
0.1A  
10mA  
1mA  
---  
CC, CR, CV, CP, EXT, SHORT, Dynamic Mode (Frequency, Time), Sweep (R, C, P)  
Load turns Off and load current is interrupted or load current limited to 110% of the Current Limit set value;  
user-selectable; Default = Max Value of H range  
System setting: Enable = Load OFF for Current Limit condition,  
---  
---  
Disable = Load current limited for Current Limit condition  
Current Limit Operation  
Front panel will display "Over Current" during Current Limit operation along with audible beep  
When load current is limited, if the current set value drops below the protection value, the unit will return to  
its original operating state.  
Power Limit Protection (OPP)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
---  
---  
W
---  
300W  
1000W  
Rated Power  
Load turns Off and load current is interrupted when rated power is exceeded or load power limited to 110%  
of the set value; user-selectable; Default = Enabled  
System setting: Enable = Load OFF, Disable = Power Limit function  
Front panel will display "Over Power" during limit operation along with audible beep  
When power limited, if the power falls below the rated power of power range, the unit will return to its original  
operating state  
Power Limit Operation  
Overtemperature Protection (OTP)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Load turns Off and load current is interrupted  
Front panel will display "Over Temperature" during overtemperature condition along with audible beep  
---  
---  
---  
---  
Overtemperature Operation  
Overvoltage Alarm (OVP)  
120-60-300  
500-12-300  
Load turns Off and load current is interrupted  
120-180-1K  
500-36-1K  
Front panel will display "Over voltage" during overvoltage condition along with audible beep  
Remove the overvoltage condition and press CANCEL key to clear the alarm.  
Overvoltage Operation  
Reverse Connection Alarm  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
A
-0.6A  
-0.15A  
-0.6A  
-0.15A  
Reverse Connection Detection Current, (*13)  
Load turns Off  
Reverse voltage of -0.6V is required for Alarm detection  
---  
---  
Reverse Connection Operation  
Front panel will display "Reverse connection" during reverse connection condition along with audible beep  
Remove the reverse connection condition and press CANCEL key to clear the alarm.  
14 | SFL DC ELECTRONIC LOAD SERIES  
Technical Specifications - SFL DC Electronic Load Series  
OTHER FUNCTIONS  
Remote Sense (SENSE)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Measures the voltage across any device connected to the load  
--  
--  
--  
--  
--  
--  
Function  
(using external sense cables connected from SENSE +/- to device +/-).  
By rear panel switch (SENSE EXT/INT switch). Set to INT when Remote Sense is disabled; Set to EXT  
when Remote Sense is enabled. +/- sense cabling required from SENSE +/- terminals to test device.  
One-touch terminal block (rear panel); Remote Sense signal is referenced to load terminal potential;  
See User's Manual for more information  
Selection  
Connection  
Trigger OUT (TRIG OUT)  
Function  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Used as a trigger signal when viewing the waveform of Dynamic mode operation  
or when synchronizing with other devices  
--  
--  
--  
--  
--  
--  
0V/+4V, pulse  
Output  
Pulse; Step 1: +4V (typical), Pulsewidth = Execution time of Step 1;  
After start of Step 2: 0V (typical); See User's Manual for waveform profile.  
One-touch terminal block (rear panel); TRIGGER OUT signal is referenced to case potential;  
See User's Manual for more information.  
Output Voltage  
--  
--  
Connection  
Current Monitor (IMON)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Output signal Used to monitor the load current waveform using an oscilloscope.  
Output impedance = 50ohms  
--  
--  
Function  
BNC connector (rear panel); IMON signal is referenced to load terminal potential (common side of IMON terminal (metal  
--  
--  
--  
--  
Connection  
shell of BNC) and Negative terminal of load are internally connected).  
Optional Current Monitor cable available; terminate cable with 1MegΩ  
Connection Cable  
Current  
--  
--  
--  
--  
--  
--  
Range  
H
M
L
A
A
A
5V / 60A  
5V / 60A  
0.2V / 0.6A  
5V / 12A  
5V / 12A  
0.2V / 0.12A  
5V / 180A  
5V / 180A  
0.2V / 1.8A  
5V / 36A  
5V / 36A  
0.2V / 0.36A  
Monitor Measurement Range  
H
M
L
---  
---  
---  
+/- (1% of Conv. Volt. + 1% of FS)  
+/- (1% of Conv. Volt. + 1% of FS)  
+/- (5% of Conv. Volt. + 3% of FS)  
50Ω  
Current Measurement Accuracy,  
(*14)  
--  
Output Impedance, (*15)  
VMode  
Function  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
--  
--  
--  
--  
Automatically changes the load mode inVoltage RisingorVoltage Fallingduring operation  
Normal mode (constant load)  
OFF: Turns off the function, Load Off (H): Load Off duringVoltage Rising, Load Off (L): Load Off duringVoltage Falling”  
CR(H): Change to CR Mode whenVoltage Rising, CR(L): Change to CR Mode whenVoltage Falling”  
CV(H): Change to CV Mode whenVoltage Rising, CV(L): Change to CV Mode whenVoltage Falling”  
CP(H): Change to CP Mode whenVoltage Rising, CP(L): Change to CP Mode whenVoltage Falling”  
Operating Mode  
--  
--  
--  
--  
--  
--  
Set using MENU screen (Default = OFF)  
Selection  
Setting Range  
0.0000 - 120.000  
0.0000 - 500.000  
0.0000 - 120.000  
0.0000 - 500.000  
FRONT/REAR PANEL  
Front/Rear Panel  
Control Functions  
3.5" color LCD display  
Function keys  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Front  
Front  
---  
---  
Displays Vertical menu, Horizontal menu, Status, Set value(s) and Measured value(s).  
Allows user to select items from Horizontal menu (5 keys) and Vertical menu (5 keys).  
Allows user to enter a numeric value (clockwise = increase value, counter-clockwise = decrease value), Stopping  
knob rotation sets the value.  
Front  
---  
Modify knob  
UP/DOWN keys: increase/decrease numeric value; UP key = increase value, DOWN key = decrease value;  
Modified value set right after pressing key  
LEFT/RIGHT keys: set decimal place; LEFT key = move decimal place left, RIGHT key = move decimal place right  
Front  
---  
CURSOR keys  
Returns to previous operation. Cancels Remote control and returns to Local operation (IEEE, USB, SEQUENCE  
operation). Clears the Alarm.  
Changes Set value(s)  
Sets the LOAD ON (key is illuminated and load current flows)  
or OFF (key is not illuminated and stops the flow of load current)  
Enters into Menu screen/Returns to Main screen.  
Front  
Front  
Front  
Front  
Front  
---  
---  
---  
---  
---  
CANCEL key  
ENTER key  
ON/OFF key  
MENU key  
Switches between Standby and Startup states.  
Main screen will appear after Startup screen and Version Display screen.  
STANDBY switch  
Front  
Rear  
---  
---  
MEMORY key  
AC ON/OFF switch  
Enters into Memory screen/Returns to Main screen.  
Main AC Power switch. “Iis the ON position. “Ois the OFF position.  
SFL DC ELECTRONIC LOAD SERIES | 15  
Technical Specifications - SFL DC Electronic Load Series  
FRONT/REAR PANEL  
Front/Rear Panel  
Display Menus  
Sets basic parameters (Load Mode, Current Limit, Measure, Measure Rate, Master/Slave setting (parallel operation),  
VMODE setting and VMODE set value). Commonly used for each Load Operating mode.  
R Interface menu added to Menu screen when installed.  
---  
---  
---  
---  
MENU screen  
MAIN screen  
Main screen and System screen can be accessed from Menu screen.  
Sets the load operating mode (Normal, Dynamic (Time), Dynamic (Frequency), SWEEP R, SWEEP C, SWEEP P).  
R Interface menu added to Menu screen when installed.  
Memory screen and Menu screen can be accessed from Main screen.  
Up to 8 settings can be stored and recalled by number. Settings stored/recalled are operation Mode, Load Mode,  
Voltage Range, Current Range, Load Set Value and Slew Rate.  
SStore operation can be performed if LOAD ON or OFF.  
---  
---  
MEMORY screen  
Recall operation will change the mode to LOAD OFF, if the mode is LOAD ON. After changing to LOAD OFF, the recall  
function will be performed.  
Main screen can be accessed from the Memory screen.  
Sets product functions (IEEE address, DIDO control, Range (DIDO) control, PrwOn (Save Settings), LCD Brightness,  
Screen Color/Language, Firmware Rev, OCP setting, OPP setting, Optional Interface selection, Reset (factory defaults).  
Main screen can be accessed from the System screen.  
---  
---  
---  
---  
SYSTEM screen  
Version Memory screen  
Embedded in System screen settings. Displays P/N, S/N, firmware revisions, options installed and calibration date.  
Front Panel Button Indications  
Key is illuminated GREEN and load current flows when ON. Key is not illuminated and stops the flow of load current  
when OFF.  
---  
---  
ON/OFF key  
Front Panel Display Indications  
Display reads Over Power during overpower condition.  
---  
---  
---  
---  
---  
---  
---  
---  
Power Limit (OPP)  
See Protective Functions (Power Limit Protection) for more information.  
Display reads Over Temperature during a overtemperature condition.  
See Protective Functions (Overtemperature Protection) for more information.  
Display reads Over voltage during a overvoltage condition.  
Over-Temperature (OTP)  
Over-Voltage Alarm (OVP)  
Reverse Connection Alarm  
See Protective Functions (Overvoltage Alarm) for more information.  
Display reads Reverse connection during a reverse connection condition.  
See Protective Functions (Reverse Connection Alarm) for more information.  
SYSTEM CONFIGURATIONS  
Parallel Operation  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Used to create higher power electronic load. Up to 10 units can be connected in parallel (including the Master unit)  
for a 10kW system (using Master/Slave Parallel cable(s)).  
Main unit is Master and all other units are Slave units. Slave units shall have the same voltage rating as the Master unit;  
300W and 1kW models can be paralleled. Load ON/OFF and Slew Rate set by Master unit (for all units).  
Master unit can display total calculated current and total calculated power of parallel configuration. Set resolution  
power changes depending on the number of units in parallel.  
---  
---  
Parallel Operation  
Rear panel load terminals shall only be used for load power connections.  
Current Ranges: H range, M range.  
---  
---  
---  
---  
+/- 3% of Full-Scale (FS) - typical  
+/- 7% of Full-Scale (FS) - typical  
If Alarm occurs (Master or Slave unit), 'FP display of Master unit reads" Booster Alarm" and all units in parallel  
configuration will be switched OFF.  
If the Alarm is triggered by a Slave unit, the Alarm must be cleared in both Master and Slave units before normal  
operation can occur.  
Current Setting Accuracy  
Alarm Setting  
---  
---  
---  
---  
Multi-Channel Synchronization  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Used to synchronize separate loads for ON/OFF control and dynamic mode operation.  
Two to ten units can be connected in a multi-channel synchronous operating scheme (one Master unit and at least  
one Slave unit) using Master/Slave Parallel cable(s).  
--  
--  
Function  
Main unit is Master and all other units are Slave units. Slave units can have a different voltage rating than the Master  
unit. Load ON/OFF set by Master unit (for all units).  
Rear panel load terminals shall only be used for load power connections.  
If Alarm occurs (Master or Slave unit), FP display of that unit reads "Booster Alarm" and unit with the Alarm will be  
switched OFF.  
--  
--  
--  
--  
Alarm Setting  
If Alarm occurs in both Master and Slave units, the Alarm only needs to be cleared in the unit with the Alarm before  
normal operation can occur for that unit.  
REMOTE ANALOG SIGNALS AND CONTROLS  
DIDO Interface (offered with IEEE option)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Optional Interface provided w/ IEEE Interface that is used for external control and monitor (Load ON/OFF control/  
status, Voltage/Current range setting/status, Alarm Input/Clear and Status, +12VDC power, SWEEP Pass/Fail and User-  
Defined Output.  
--  
--  
Function  
Enabled/Disabled via System Screen  
16 | SFL DC ELECTRONIC LOAD SERIES  
Technical Specifications - SFL DC Electronic Load Series  
REMOTE ANALOG SIGNALS AND CONTROLS (Continued)  
DIDO Interface (offered with IEEE option)  
Control Input (Edge Detected)  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
---  
---  
Load ON/OFF, (*16) (*17)  
Optocoupler LED input: L = Optocoupler LED OFF, H = Optocoupler LED ON  
Optocoupler LED input; CUR-RANGE1 (pins 3-4), CUR-RANGE2 (pins 5-6): Edge-Detected  
---  
---  
Current Range, (*16) (*17)  
LL: Maintain same status, LH: Current Range = L, HL: Current Range = M, HH: Current Range = H  
Default = Disabled, Use System screen to Enable/Disable (Enables/Disables both Current range and Voltage range)  
Optocoupler LED input: L = L range, H = H range; Default = Disabled, Use System screen to Enable/Disable (Enables/  
Disables both Current range and Voltage range)  
---  
---  
Voltage Range, (*16) (*17)  
---  
---  
---  
---  
External Alarm, (*16) (*17)  
Protection/Alarm Clear, (*16) (*17)  
Status Output  
Optocoupler LED input: L = Alarm OFF, H = Alarm ON  
Optocoupler LED input: L = Alarm Not Cleared, H = Alarm Cleared  
---  
---  
---  
---  
Load ON/OFF, (*18)  
Optocoupler open-collector output: Open = Load OFF, Closed = Load ON  
Optocoupler open-collector output (2 bit)  
Current Range, (*18)  
STATUS1 (CUR-RANGE STATUS1) - L range = Closed, M range = Open, H range = Closed  
STATUS2 (CUR-RANGE STATUS2) - L range = Open, M range = Closed, H range = Closed  
---  
---  
---  
---  
---  
---  
---  
---  
Voltage Range, (*18)  
Optocoupler open-collector output: Open = L range, Closed = H range  
Optocoupler open-collector output: Open = No Alarm Clear, Closed = Alarm Cleared  
Optocoupler open-collector output: Open = user-defined, Closed = user-defined; Controlled from IEEE or USB Interface  
Optocoupler open-collector output: Open = PASS SWEEP C/SWEEP P, Closed = FAIL SWEEP C/SWEEP P  
Protection/Alarm Clear, (*18)  
User defined output, (*18)  
SWEEP Decision, (*18)  
Power Supply Output  
---  
---  
---  
---  
---  
---  
DC Power Supply for DIDO Control/Status signals  
Can be used to drive optocoupler LED input, relay input (to drive optocoupler LED)  
or open-collector output (external series resistor required)  
+12VDC Power Supply  
Limited to < 100mA, Referenced to case potential  
AC INPUT POWER  
Power Input  
Voltage  
Frequency  
Power  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
500-36-1K  
VAC  
Hz  
VA  
85 - 264VAC (Overvoltage Category II)  
50Hz +/- 2Hz or 60Hz +/- 2Hz  
< 60VA  
< 65VA  
ENVIRONMENTAL CONDITIONS  
Environmental Conditions  
Operating Environment  
Operating Temperature/Humidity  
Storage Temperature  
120-60-300  
Indoor use  
500-12-300  
120-180-1K  
---  
---  
---  
---  
0ºC to +40ºC (+32ºF to +104ºF), 5% to 85% RH (absolute humidity 1 to 25 g/m3, no condensation)  
-10ºC to +50ºC (+14ºF to +122ºF), 5% to 95% RH (absolute humidity 1 to 29 g/m3, no condensation)  
Operating: up to 2000m (~6562ft)  
Altitude  
MECHANICAL SPECS  
Mechanical Specs  
Cooling  
Weight  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
---  
---  
---  
kg (lbs)  
Forced air cooling by internal fans with air flow from front to rear (no side ventilation), zero-stackable  
approx. 6.5kg (14.3lbs)  
approx. 13kg (28.6lbs)  
Width: 215mm (8.46 inches), Height: 128.6mm (5.06  
inches), Depth: 420mm (16.54 inches)  
refer to Outline Drawing (300W model)  
Benchtop or rack-mount  
Benchtop using mounting feet. Rack-mount kit  
available for 300W model (single unit or two unit). See  
Outline Drawing(s)  
Width: 430mm (16.93 inches), Height: 128.6mm (5.06 inches),  
mm  
---  
Depth: 450mm (17.72 inches)  
Dimensions (W x H x D)  
(inches)  
refer to Outline Drawing (1000W model)  
Benchtop or rack-mount  
Benchtop using mounting feet. Rack-mount kit available for  
1000W model (single unit). See Outline Drawing(s)  
---  
---  
Mounting  
---  
---  
---  
standard IEC inlet  
AC Input connector  
DC Output connections  
Binding post (Load current < 20A); Internally  
connected to rear panel load terminals  
Terminals with M6 hardware; internally connected to  
front panel load terminals  
Terminals with M8 hardware; internally connected to rear panel  
Front Panel  
load terminals  
Terminals with M8 hardware; internally connected to front  
panel load terminals  
Rear Panel  
Front Panel  
---  
---  
USB Type B (built-in standard)  
MASTER/SLAVE connectors: RJ45 type, use Master/Slave Parallel cable  
TRIG-OUT connector: One-touch terminal block for "+" and "-" connections,  
AWG#16-AWG#26 (single wire) - See User's Manual  
Interface connections  
EXT-IN connector: One-touch terminal block for "+" and "-" connections,  
AWG#16-AWG#26 (single wire) - See User's Manual  
Rear Panel  
---  
SENSE connector: One-touch terminal block for "+" and "-" connections,  
AWG#16-AWG#26 (single wire) - See User's Manual  
IMON port: BNC-type, use IMON cable  
SFL DC ELECTRONIC LOAD SERIES | 17  
Technical Specifications - SFL DC Electronic Load Series  
INTERFACES  
Interfaces  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
Parallel/Multi-Synchronization connection (from unit-to-unit); RJ45 connector (rear panel), cable length ~ 1m  
---  
---  
---  
---  
Master/Slave  
(3.3ft), one cable per unit; referenced to negative load terminal  
TRIGGER-OUT connection (for Dynamic operation viewing and device synchronization); One-touch terminal  
block for "+" and "-" connections (rear panel), referenced to case potential.  
EXTERNAL Mode programming connections; One-touch terminal block for "+" and "-" connections (rear panel),  
referenced to load potential.  
Remote Sense (for measuring test device voltage); One-touch terminal block for "+" and "-" connections  
(rear panel), referenced to load potential.  
Current Monitor connection (to monitor load current waveform using scope); BNC-type (rear panel),  
common side of IMON terminal (metal shell of BNC) and Negative (-) terminal of load are internally connected).  
USB2.0 compliant, USBTMC; Type B USB connector (front panel), cable length < 4m, referenced to Chassis potential  
IEEE 488.1 compliant, Address 1-30 (Default address = 1); IEEE connector with metal backshell (rear panel),  
cable length < 4m; referenced to Chassis potential  
TRIGGER-OUT  
EXT-IN  
SENSE  
---  
---  
---  
IMON  
USB (built-in standard interface)  
IEEE (optional interface)  
Optocoupler-based Control/Monitor Interface (provided with IEEE Interface); Two-row 16 position (female-socket)  
rectangular IDC connector (rear panel), referenced to case potential when using DIDO +12VDC Power Supply.  
Ripple Measurement connection (for measuring ripple and noise), BNC-type connector (rear panel) with cover,  
common side of BNC (metal shell) and negative (-) terminal of load are internally connected.  
---  
---  
DIDO (built-in standard w/ IEEE Interface)  
R (optional interface)  
SAFETY  
Safety  
Applicable Standards  
Pollution Degree  
120-60-300  
Complies with EN61010-1:2010, 3rd Edition  
Pollution Degree II  
500-12-300  
120-180-1K  
500-36-1K  
---  
---  
AC Input: Hazardous Primary  
Load Output (front/rear panel), Master/Slave Interface, TRIG-OUT Interface, EXT-IN Interface, SENSE Interface,  
USB Interface, IEEE Interface, DIDO Interface, R Interface: Hazardous Secondary  
---  
Interface Classification  
---  
---  
Withstand Voltage  
Insulation Resistance  
AC Input-to-Output terminals/Chassis: 1500VAC for 60 seconds  
> 30Megohms between AC Input and Output terminals/Chassis) @ 500VDC  
EMC  
EMC  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
Applicable Standards, (*19)  
Electrostatic Discharge (ESD)  
Fast Transient Burst  
Complies with EN61326-1: 2013 (Class A)  
EN 61000-4-2:2009 - 2kV/4kV (Contact Discharge), 2kV/4kV/8kV (Air Discharge)  
EN 61000-4-4:2012 - 1kV for I/O Signal and Control Ports / 2kV for AC Power Port  
EN 61000-4-5:2006 - 0.5kV/1kV line-to-line and 0.5kV/1kV/2kV line-to-earth (AC Power Port)  
EN 61000-4-11:2004 - AC Power Port  
Lightning Surge Immunity  
Voltage Dips and Short Term Interruptions  
Power Frequency, Magnetic Field  
Conducted Immunity  
Radiated Immunity  
Voltage Fluctuations and Flicker  
Conducted Emissions  
EN 61000-4-8:2010 - 30A/m  
EN 61000-4-6:2009 - 3V (for I/O Signal and Control Ports / AC Power Port)  
EN 61000-4-3:2006 + A1:2008 + A2: 2010 - 1V/m, 3V/m, 10V/m  
EN 61000-3-3:2013  
EN 55011 (Group 1, Class A): 0.15MHz - 30MHz  
EN 55011 (Group 1, Class A): 30MHz - 1GHz  
Radiated Emissions  
WARRANTY  
Warranty  
Warranty  
120-60-300  
500-12-300  
120-180-1K  
500-36-1K  
yrs  
2yrs  
OTHER MEASUREMENT CHARACTERISTICS  
Ripple Measurement Module Option (FP Display)  
Common for All Models  
DC Voltage Measurement  
V
+/- 6V  
0.1mV  
+/- 60V  
1.0mV  
-60.000V to -5.600V  
+5.600V to +60.000V  
+/- 500V  
10.omV  
-500.00V to -56.00V  
+56.00V to +500.00V  
Voltage Measurement Range  
Voltage Measurement Resolution  
Voltage Measurement Autorange  
mV  
V
-6.0000V to +6.0000V  
---  
V
+/- (0.025% of reading + 0.025% of FS)  
+/- 500V  
Voltage Measurement Accuracy, (*4)  
Maximum Applied Voltage  
ms  
approximately 100ms  
Measurement Time, (*11)  
Ripple / Noise Voltage Measurement  
Maximum Input Voltage  
V
+/- 3V  
mV  
mV  
---  
300mV  
0.1mV  
3000mV  
1.0mV  
R/N Voltage Measurement Range  
R/N Voltage Measurement Resolution  
R/N Voltage Measurement Accuracy, (*20)  
THRU  
+/- (2% of reading + 1% of FS)  
50Hz to 100MHz  
---  
---  
---  
50Hz to 2kHz  
5kHz to 100MHz  
Filter  
LPF, (*21)  
HPF, (*22)  
---  
---  
ms  
50Hz to 20MHz  
0.0% to 50.0% (per 0.5%)  
approximately 350ms  
20 MHz Bandwidth Limit  
Ripple Ratio, (*23) (*24)  
Measurement Time, (*11)  
Power Measurement  
Measurement method, (*25)  
Measurement Time, (*11)  
---  
ms  
Input voltage x Load current  
approximately 200ms  
18 | SFL DC ELECTRONIC LOAD SERIES  
Technical Specifications - SFL DC Electronic Load Series  
(*1) This parameter will vary depending on unit internal temperature and unit operating time.  
(*2) Measured at the rear panel load terminals. This is not a set value in CR mode.  
(*3) The minimum operating voltage varies depending on the current value.  
(*4) At an ambient temperature of +23ºC +/- 5ºC (+73.4ºF +/- 9ºF).  
(*5) At rear panel load terminal. Can ONLY be set in CC mode and EXT mode (cannot be set in CR, CP or SHORT mode). In CV mode, this is the reponse time setting.  
(*6) Vin is valid starting from 1/10V and greater for the selected range. FS is the Full-Scale current of the Current H range.  
(*7) FS is the Full-Scale Power of the Current H range.  
(*8) Accuracy of External Control Mode is only when the control voltage input is 10V.  
(*9) Short-circuit is created across the load terminals.  
(*10) Voltage measurement range changes in accordance with the Voltage setting range selected.  
(*11) This specification does not apply immediately after the Voltage range has changed.  
(*12) Current measurement range changes in accordance with the Current setting range selected.  
(*13) Reverse connection voltage of -0.6V is required for alarm detection.  
(*14) Conv. Volt. indicates converted voltage value of "Measurement Current Value x (Current Monitor FS / Rated Current)".  
(*15) With a 1MegΩ terminating resistor.  
(*16) H condition indicates that optocoupler LED is ON; L condition indicates that optocoupler LED is OFF.  
(*17) Resistance of 2.4kΩ in series with LED. Applying 5V-12V results in H condition. Ensure that LED input current is less than 4.5mA.  
(*18) Open-collector output. Maximum applied voltage = 30V, Maximum collector current = 10mA  
(*19) Operation in an environment with a strong electro-magnetic field may cause measured value and load setting to be different.  
(*20) In ripple ration of 0% to 10%, In the range of 10kHz to 10MHz, At an ambient temperature of +23ºC +/- 5ºC (+73.4ºF +/- 9ºF).  
(*21) LPF = Low Pass Filter  
(*22) HPF = High Pass Filter  
(*23) In the range of 10kHz to 10MHz.  
(*24) Ripple ratio is the ratio of the switching ripple period originating from switching period and time with ripple noise. Measured values of ripple voltage and noise  
voltage becomes equal at 0.0% setting.  
(*25) Measurement results are shown as absolute values.  
NOTES:  
Setpoint refers to set value, reading refers to reading and FS refers to the maximum value in each range.  
Specifications indicate values after warm-up time of 30 minutes. Vin is load input voltage.  
Values indicated with accuracy in specifications are guaranteed values (guaranteed for warranty period).  
Values without accuracy are nominal values or representative values (indicated as typ.).  
SFL DC ELECTRONIC LOAD SERIES | 19  
Outline Drawing, SFL 300W (120V or 500V Models)  
20 | SFL DC ELECTRONIC LOAD SERIES  
Outline Drawing, SFL 1000W (120V or 500V Models)  
SFL DC ELECTRONIC LOAD SERIES | 21  
Outline Drawing, SFL 300W, EIA Rack-Mount Kit  
22 | SFL DC ELECTRONIC LOAD SERIES  
Outline Drawing, SFL 1000W, EIA Rack-Mount Kit  
SFL DC ELECTRONIC LOAD SERIES | 23  
Outline Drawing, SFL 300W, JIS Rack-Mount Kit  
24 | SFL DC ELECTRONIC LOAD SERIES  
Outline Drawing, SFL 1000W, JIS Rack-Mount Kit  
SFL DC ELECTRONIC LOAD SERIES | 25  
TDK-Lambda France SAS  
TDK-Lambda Americas  
Tel: +33 1 60 12 71 65  
france@fr.tdk-lambda.com  
Tel: +1 800-LAMBDA-4 or 1-800-526-2324  
powersolutions@us.tdk-lambda.com  
www.us.lambda.tdk.com  
www.emea.lambda.tdk.com/fr  
Italy Sales Office  
Tel: +39 02 61 29 38 63  
info.italia@it.tdk-lambda.com  
www.emea.lambda.tdk.com/it  
TDK Electronics do Brasil Ltda  
Tel: +55 11 3289-9599  
sales.br@tdk-electronics.tdk.com  
www.tdk-electronics.tdk.com/en  
Netherlands  
info@nl.tdk-lambda.com  
www.emea.lambda.tdk.com/nl  
TDK-Lambda Germany GmbH  
Tel: +49 7841 666 0  
TDK-Lambda Corporation  
Tel: +81-3-6778-1113  
www.jp.lambda.tdk.com  
info.germany@de.tdk-lambda.com  
www.emea.lambda.tdk.com/de  
TDK-Lambda (China) Electronics Co. Ltd.  
Tel: +86 21 6485-0777  
powersolutions@cn.tdk-lambda.com  
www.lambda.tdk.com.cn  
TDK-Lambda Singapore Pte Ltd.  
Tel: +65 6251 7211  
tls.mkt@sg.tdk-lambda.com  
www.sg.lambda.tdk.com  
Austria Sales Office  
Tel: +43 2256 655 84  
info@at.tdk-lambda.com  
www.emea.lambda.tdk.com/at  
TDK India Private Limited, Power Supply Division  
Switzerland Sales Office  
Tel: +41 44 850 53 53  
Tel: +91 80 4039-0660  
mathew.philip@in.tdk-lambda.com  
www.sg.lambda.tdk.com  
info@ch.tdk-lambda.com  
www.emea.lambda.tdk.com/ch  
Nordic Sales Office  
Tel: +45 8853 8086  
info@dk.tdk-lambda.com  
www.emea.lambda.tdk.com/dk  
TDK-Lambda UK Ltd.  
Tel: +44 (0) 12 71 85 66 66  
info@uk.tdk-lambda.com  
www.emea.lambda.tdk.com/uk  
TDK-Lambda Ltd.  
Tel: +9 723 902 4333  
info@tdk-lambda.co.il  
www.emea.lambda.tdk.com/il  
C.I.S.  
Commercial Support:  
Tel: +7 (495) 665 2627  
Technical Support:  
Tel: +7 (812) 658 0463  
info@tdk-lambda.ru  
www.emea.lambda.tdk.com/ru  

相关型号:

TDK

SFL500-12-300-R

电子负载
TDK

SFL500-36-1K

电子负载
TDK

SFL500-36-1K-IEEE

电子负载
TDK
TDK

SFL500-36-1K-R

电子负载
TDK

SFL630S.5TX

Power Field-Effect Transistor
SSDI

SFL630S.5TXV

Power Field-Effect Transistor
SSDI

SFL900B

super-PFC/PSRTM Controller for LED Lighting
SIFIRST

SFL900BDP

super-PFC/PSRTM Controller for LED Lighting
SIFIRST

SFL900BSG

super-PFC/PSRTM Controller for LED Lighting
SIFIRST

SFL900BSGT

super-PFC/PSRTM Controller for LED Lighting
SIFIRST