CC10-0503SR-E [TDK]

Insulation type DC-DC converter; 绝缘型DC-DC转换器
CC10-0503SR-E
型号: CC10-0503SR-E
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

Insulation type DC-DC converter
绝缘型DC-DC转换器

转换器 DC-DC转换器
文件: 总25页 (文件大小:5684K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
InsulationꢀtypeꢀDC-DCꢀconverter  
CC-E  
Y
E
A
R
5
S
EN60950-1  
warranty  
ow Voltage Directive  
UL60950-1/  
L
CSA C22.2 No.60950-1  
■ Features  
■ Model-naming method  
●Mounting area halved compared to existing products  
●Nonuse of tantalum capacitor or aluminum electro-  
lytic capacitor  
●Remote On/Off function incorporated in all series of  
products  
ꢀ ꢀCCꢀ3ꢀ-ꢀ05ꢀ05ꢀSꢀFꢀ-E  
F: Horizontally-mounted DIP type  
R: Horizontally-mounted SMD type  
FS Vertically-mounted SIP type  
Shape  
Symbol for number of outputs  
S: Single output, D: Dual outputs  
Nominal output voltage  
03: 3.3V, 05: 5V, 12: 12V  
●High accuracy of ±3% in output voltage (10W of  
lower single output)  
Nominal input voltage  
05: 5V, 12: 12V, 24: 24V, 48: 48V  
●5-side metal-shielded low noise design  
●Lightweight design with no resin filled up  
●Supports DIP insertion,SMD mounting and SIP verti-  
cal insertion (3W products)  
Maximum output power  
1R5: 1.5W, 3: 3W, 6:6W  
10: 10W, 15: 15W, 25: 25W  
Representing series name by  
combination with "-E"at the end  
●Approved by UL60950-1, CSA C22.2 No.60950-1  
(C-UL), and EN60950-1 (NEMKO)  
Conformity to RoHS Directive  
■ Applications  
This means that, in conformity with EU Directive  
2002/95/EC, lead, cadmium, mercury, hexavalent  
chromium, and specific bromine-based flame retar-  
dants, PBB and PBDE, have not been used, except for  
exempted applications.  
■ Product Line up  
Model name  
Model name  
Model name  
Model name  
Output  
power  
Input  
(output voltage: 3.3V)  
(output voltage: 5V)  
(output voltage: 12V/15V)  
(output voltage: ±12V/±15V)  
voltage  
Output current  
DIP type  
SMD type  
SIP type Output current  
DIP type  
SMD type  
SIP type Output current  
DIP type  
SMD type  
SIP type Output current  
DIP type  
SMD type  
SIP type  
5V  
0.4A CC1R5-0503SF-E CC1R5-0503SR-E  
-
-
-
-
0.3A CC1R5-0505SF-E CC1R5-0505SR-E  
0.3A CC1R5-1205SF-E CC1R5-1205SR-E  
0.3A CC1R5-2405SF-E CC1R5-2405SR-E  
0.3A CC1R5-4805SF-E CC1R5-4805SR-E  
-
-
-
-
0.125A (0.1A) CC1R5-0512SF-E CC1R5-0512SR-E  
0.125A (0.1A) CC1R5-1212SF-E CC1R5-1212SR-E  
0.125A (0.1A) CC1R5-2412SF-E CC1R5-2412SR-E  
0.125A (0.1A) CC1R5-4812SF-E CC1R5-4812SR-E  
-
-
-
-
0.06A (0.05A) CC1R5-0512DF-E CC1R5-0512DR-E  
0.06A (0.05A) CC1R5-1212DF-E CC1R5-1212DR-E  
0.06A (0.05A) CC1R5-2412DF-E CC1R5-2412DR-E  
0.06A (0.05A) CC1R5-4812DF-E CC1R5-4812DR-E  
-
12V 0.4A CC1R5-1203SF-E CC1R5-1203SR-E  
24V 0.4A CC1R5-2403SF-E CC1R5-2403SR-E  
48V 0.4A CC1R5-4803SF-E CC1R5-4803SR-E  
-
1.5W  
3W  
-
-
5V  
0.8A CC3-0503SF-E  
CC3-0503SR-E CC3-0503SS-E 0.6A  
CC3-1203SR-E CC3-1203SS-E 0.6A  
CC3-2403SR-E CC3-2403SS-E 0.6A  
CC3-4803SR-E CC3-4803SS-E 0.6A  
CC3-0505SF-E  
CC3-1205SF-E  
CC3-2405SF-E  
CC3-4805SF-E  
CC6-0505SF-E  
CC6-1205SF-E  
CC6-2405SF-E  
CC6-4805SF-E  
CC10-0505SF-E  
CC10-1205SF-E  
CC10-2405SF-E  
CC10-4805SF-E  
CC15-2405SF-E  
CC25-2405SF-E  
CC3-0505SR-E  
CC3-1205SR-E  
CC3-2405SR-E  
CC3-4805SR-E  
CC6-0505SR-E  
CC6-1205SR-E  
CC6-2405SR-E  
CC6-4805SR-E  
CC10-0505SR-E  
CC10-1205SR-E  
CC10-2405SR-E  
CC10-4805SR-E  
CC15-2405SR-E  
CC25-2405SR-E  
CC3-0505SS-E 0.25A (0.2A)  
CC3-1205SS-E 0.25A (0.2A)  
CC3-2405SS-E 0.25A (0.2A)  
CC3-4805SS-E 0.25A (0.2A)  
CC3-0512SF-E  
CC3-1212SF-E  
CC3-2412SF-E  
CC3-4812SF-E  
CC6-0512SF-E  
CC6-1212SF-E  
CC6-2412SF-E  
CC6-4812SF-E  
CC3-0512SR-E  
CC3-1212SR-E  
CC3-2412SR-E  
CC3-4812SR-E  
CC6-0512SR-E  
CC6-1212SR-E  
CC6-2412SR-E  
CC6-4812SR-E  
CC10-0512SR-E  
CC10-1212SR-E  
CC10-2412SR-E  
CC10-4812SR-E  
-
CC3-0512SS-E 0.125A (0.1A) CC3-0512DF-E  
CC3-1212SS-E 0.125A (0.1A) CC3-1212DF-E  
CC3-2412SS-E 0.125A (0.1A) CC3-2412DF-E  
CC3-4812SS-E 0.125A (0.1A) CC3-4812DF-E  
CC3-0512DR-E  
CC3-1212DR-E  
CC3-2412DR-E  
CC3-4812DR-E  
CC6-0512DR-E  
CC6-1212DR-E  
CC6-2412DR-E  
CC6-4812DR-E  
CC10-0512DR-E  
CC10-1212DR-E  
CC10-2412DR-E  
CC10-4812DR-E  
-
CC3-0512DS-E  
12V 0.8A CC3-1203SF-E  
24V 0.8A CC3-2403SF-E  
48V 0.8A CC3-4803SF-E  
CC3-1212DS-E  
CC3-2412DS-E  
CC3-4812DS-E  
5V  
1.2A CC6-0503SF-E  
CC6-0503SR-E  
CC6-1203SR-E  
CC6-2403SR-E  
CC6-4803SR-E  
-
-
-
-
-
-
-
-
-
-
1A  
1.2A  
1.2A  
1.2A  
2A  
-
-
-
-
-
-
-
-
-
-
0.5A (0.4A)  
0.5A (0.4A)  
0.5A (0.4A)  
0.5A (0.4A)  
-
-
-
-
-
-
-
-
-
-
0.25A (0.2A)  
0.25A (0.2A)  
0.25A (0.2A)  
0.25A (0.2A)  
CC6-0512DF-E  
CC6-1212DF-E  
CC6-2412DF-E  
CC6-4812DF-E  
-
-
-
-
-
-
-
-
-
-
12V 1.2A CC6-1203SF-E  
24V 1.2A CC6-2403SF-E  
48V 1.2A CC6-4803SF-E  
6W  
5V  
2.5A CC10-0503SF-E CC10-0503SR-E  
0.8A (0.64A) CC10-0512SF-E  
1A (0.8A) CC10-1212SF-E  
1A (0.8A) CC10-2412SF-E  
1A (0.8A) CC10-4812SF-E  
0.4A (0.32A) CC10-0512DF-E  
0.45A (0.36A) CC10-1212DF-E  
0.45A (0.36A) CC10-2412DF-E  
0.45A (0.36A) CC10-4812DF-E  
12V 2.5A CC10-1203SF-E CC10-1203SR-E  
24V 2.5A CC10-2403SF-E CC10-2403SR-E  
48V 2.5A CC10-4803SF-E CC10-4803SR-E  
2A  
10W  
2A  
2A  
15W 24V 4.5A CC15-2403SF-E CC15-2403SR-E  
25W 24V 7.5A CC25-2403SF-E CC25-2403SR-E  
3A  
-
-
-
-
-
-
-
-
5A  
-
-
00ꢀ-0ꢀ/2008042ꢀ/etl_cc_e  
・All specifications are subject to change without notice.  
2
CC1R5-E  
CC1R5-E Specifications  
MODEL  
CC1R5-0503Sx-E CC1R5-0505Sx-E  
CC1R5-0512Sx-E  
CC1R5-0512Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC5.0  
DC4.5-9.0  
80  
Voltage Range  
Efficiency (typ)  
Input  
(*1)  
(*1)  
A
71  
0.372  
3.3  
77  
0.390  
5
79  
0.380  
Current (typ)  
0.375  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.125  
15  
0.100  
1.5  
± 12  
0.060  
± 15  
0.050  
0.400  
1.32  
0.300  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature–40°C to +50°C)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
3.2  
Mechanical  
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC1R5-1203Sx-E CC1R5-1205Sx-E  
CC1R5-1212Sx-E  
CC1R5-1212Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC12  
DC9.0-18  
82  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
73  
0.151  
3.3  
78  
0.160  
5
81  
0.154  
0.152  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.125  
15  
0.100  
1.5  
± 12  
0.060  
± 15  
0.050  
0.400  
1.32  
0.300  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature–40°C to +50°C)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4 - ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
3.2  
Mechanical  
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
CC1R5-E  
MODEL  
CC1R5-2403Sx-E CC1R5-2405Sx-E  
CC1R5-2412Sx-E  
CC1R5-2412Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC24  
DC18-36  
81  
Voltage Range  
Efficiency (typ)  
Input  
(*1)  
(*1)  
A
72  
0.076  
3.3  
77  
0.081  
5
79  
0.079  
Current (typ)  
0.077  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.125  
15  
0.100  
1.5  
± 12  
0.060  
± 15  
0.050  
0.400  
1.32  
0.300  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature–40°C to +50°C)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
3.2  
Mechanical  
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC1R5-4803Sx-E CC1R5-4805Sx-E  
CC1R5-4812Sx-E  
CC1R5-4812Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC48  
DC36-76  
80  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
70  
0.039  
3.3  
76  
0.041  
5
79  
0.040  
0.039  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.125  
15  
0.100  
1.5  
± 12  
0.060  
± 15  
0.050  
0.400  
1.32  
0.300  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature–40°C to +50°C)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
3.2  
Mechanical  
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
4
CC1R5-E  
Outline Drawing  
CC1R5-xxxxxF-Eꢀ(DIPꢀtype)  
16.6 0.2  
Recommended measurements for  
mounting board  
Shape/Dimensions  
14.605  
Outer shape of  
product  
t=0.3  
12.7  
7-ø1.0 (land diameter ø2.0)  
16.51  
1.905  
12.7  
1.905  
2.7  
a
b
2-ø1.5 (land diameter ø2.5)  
a
3
2
b
4
5
16.51  
1.0  
7-0.3×0.6  
6
7
a
Unit: mm  
2.7  
1
Allowable tolerance is 0.5 if not specified separately.  
b
CC1R5-xxxxxR-Eꢀ(SMDꢀtype)  
16.6 0.2  
Shape/Dimensions  
Recommended measurements for  
mounting board  
Outer shape of  
product  
t=0.3  
Coplanarity: 0.1 or lower  
16.51  
19.81  
1.8  
1.8  
3.2  
15.6  
22.0  
3.2  
3
2
4
5
7-0.3×0.6  
6
7
1
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
Connection diagram  
CC1R5-xxxxSx-E  
CC1R5-xxxxDx-E  
Terminal connections  
Terminal connections  
No.1 +Vin  
+Vin  
+Vout  
+Vin  
+Vout  
1
7
6
5
1
7
6
5
No.1 +Vin  
No.2 RC  
No.2 RC  
TRM  
TRM  
COM  
–Vout  
No.3 –Vin  
No.4 NC  
No.3 –Vin  
RC  
2
–Vout  
RC  
No.4 –Vout  
2
3
No.5 –Vout  
No.6 TRM  
No.7 +Vout  
No.5 Common out  
No.6 TRM  
4 NC  
3
4
–Vin  
–Vin  
No.7 +Vout  
Derating Curve  
100  
80  
60  
40  
20  
0
Natural air cooling  
a
b
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
020406080100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
DIP/SMD  
CC3-E  
CC3-E Specifications  
MODEL  
CC3-0503Sx-E  
CC3-0505Sx-E  
CC3-0512Sx-E  
CC3-0512Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC5.0  
DC4.5-9.0  
82  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
73  
0.723  
3.3  
0.800  
2.64  
77  
0.779  
5
81  
0.741  
0.732  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
4.5  
Mechanical  
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC3-1203Sx-E  
CC3-1205Sx-E  
CC3-1212Sx-E  
CC3-1212Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC12  
DC9.0-18  
82  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
74  
0.297  
3.3  
0.800  
2.64  
79  
0.316  
5
81  
0.309  
0.305  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
4.5  
Mechanical  
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
DIP/SMD  
CC3-E(  
MODEL  
CC3-2403Sx-E  
CC3-2405Sx-E  
CC3-2412Sx-E  
CC3-2412Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC24  
DC18-36  
82  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
73  
0.151  
3.3  
0.800  
2.64  
78  
0.160  
5
81  
0.154  
0.152  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
4.5  
Mechanical  
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC3-4803Sx-E  
CC3-4805Sx-E  
CC3-4812Sx-E  
CC3-4812Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC48  
DC36-76  
81  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
73  
0.075  
3.3  
0.800  
2.64  
79  
0.079  
5
80  
0.078  
0.077  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
4.5  
Mechanical  
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
DIP/SMD  
CC3-E(  
Outline Drawing  
CC3-xxxxxF-Eꢀ(DIPꢀtype)  
16.6 0.2  
Shape/Dimensions  
Recommended measurements for mounting board  
20.32  
Outer shape of product  
t=0.3  
7-ø1.0 (land diameter ø2.0)  
17.78  
22.86  
2.7  
2.54  
17.78  
2.54  
a
b
2-ø1.5 (land diameter ø2.5)  
22.86  
a
3
b
4
1.0  
2
5
7-0.3×0.6  
6
2.7  
1
7
a
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
b
CC3-xxxxxR-Eꢀ(SMDꢀtype)  
16.6 0.2  
Shape/Dimensions  
Recommended measurements for mounting board  
Outer shape of product  
t=0.3  
22.86  
Coplanarity: 0.1 or lower  
26.16  
1.8  
1.8  
3.2  
22.0  
28.4  
3.2  
3
2
4
5
7-0.3×0.6  
6
7
1
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
Connection diagram  
CC3-xxxxSx-E  
CC3-xxxxDx-E  
Terminal connections  
No.1 +Vin  
No.2 RC  
No.3 –Vin  
No.4 NC  
No.5 –Vout  
No.6 TRM  
No.7 +Vout  
Terminal connections  
No.1 +Vin  
No.2 RC  
No.3 –Vin  
No.4 –Vout  
No.5 Common out  
No.6 TRM  
+Vin  
1
+Vout  
TRM  
+Vin  
1
+Vout  
7
6
5
7
6
5
TRM  
COM  
–Vout  
RC  
2
RC  
2
–Vout  
4 NC  
4
3
3
–Vin  
–Vin  
No.7 +Vout  
Derating Curve  
100  
80  
60  
40  
20  
0
Natural air cooling  
a
b
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
020406080100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
8
SIP  
CC3-E(  
CC3-E Specifications  
MODEL  
CC3-0503SS-E  
CC3-0505SS-E  
CC3-0512SS-E  
CC3-0512DS-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
Voltage Range  
Efficiency (typ)  
Current (typ)  
V
V
DC5.0  
DC4.5-9.0  
82  
Input  
(*1)  
(*1)  
A
73  
0.723  
3.3  
0.800  
2.64  
77  
0.779  
5
81  
0.741  
0.732  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.67  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Isolation  
Standards Safety Standards  
Weight (typ)  
Size (W x H x D)  
g
mm  
7
Mechanical  
27.8 x 17.9 x 9.2  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC3-1203SS-E  
CC3-1205SS-E  
CC3-1212SS-E  
CC3-1212DS-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC12  
DC9.0-18  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
73  
0.301  
3.3  
0.800  
2.64  
79  
0.316  
5
82  
0.305  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.67  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Isolation  
Standards Safety Standards  
Weight (typ)  
Size (W x H x D)  
g
mm  
7
Mechanical  
27.8 x 17.9 x 9.2  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
SIP  
CC3-E(  
MODEL  
CC3-2403SS-E  
CC3-2405SS-E  
CC3-2412SS-E  
CC3-2412DS-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
Voltage Range  
Efficiency (typ)  
Current (typ)  
V
V
DC24  
DC18-36  
82  
Input  
(*1)  
(*1)  
A
73  
0.151  
3.3  
0.800  
2.64  
78  
0.160  
5
81  
0.154  
0.152  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.67  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Isolation  
Standards Safety Standards  
Weight (typ)  
Size (W x H x D)  
g
mm  
7
Mechanical  
27.8 x 17.9 x 9.2  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC3-4803SS-E  
CC3-4805SS-E  
CC3-4812SS-E  
CC3-4812DS-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC48  
DC36-76  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
73  
0.075  
3.3  
0.800  
2.64  
79  
0.079  
5
82  
0.076  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.250  
15  
0.200  
3
± 12  
0.125  
± 15  
0.100  
0.600  
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Isolation  
Standards Safety Standards  
Weight (typ)  
Size (W x H x D)  
g
mm  
7
Mechanical  
27.8 x 17.9 x 9.2  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
ꢀ0  
SIP  
CC3-E(  
Outline Drawing  
CC3-xxxxxS-Eꢀ(SIPꢀtype)  
9.2  
Shape/Dimensions  
(
)
1 t=0.3  
2.47  
P
P
P
P
22.86  
2P  
P
P
P
P
2.47  
6
17.78  
5.01  
P=2.54  
27.8  
a
5
Recommended measurements for mounting board  
1
2
3
4
7
8
9 10  
27.8  
a
2.47  
22.86  
2.47  
17.78  
P=2.54  
2-ø1.5 (land diameter ø2.5)  
4
SMD mounting space  
P
P
P
P
2P  
P
P
P
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
9-ø0.8 (land diameter ø2.0)  
Connection diagram  
CC3-xxxxSS-E  
CC3-xxxxDS-E  
Terminal connections  
No.1 +Vout  
No.2 NC  
Terminal connections  
No.1 +Vout  
No.2 COM  
No.3 COM  
No.4 –Vout  
No.5 TRM  
No.6 NC  
1
2
3
4
5
7
8
9
10  
1
2
3
4
5
7
8
9
10  
No.3 NC  
No.4 –Vout  
No.5 TRM  
No.6 NC  
Load  
Load Load  
No.7 RC  
No.7 RC  
No.8 –Vin  
No.9 +Vin  
No.10 +Vin  
No.8 –Vin  
No.9 +Vin  
No.10 +Vin  
Derating Curve  
100  
80  
60  
40  
20  
0
Natural air cooling  
a
b
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
0
20  
406080  
100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
ꢀꢀ  
CC6-E  
CC6-E Specifications  
MODEL  
CC6-0503Sx-E  
CC6-0505Sx-E  
CC6-0512Sx-E  
CC6-0512Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC5.0  
DC4.5-9.0  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
76  
1.042  
3.3  
1.200  
3.96  
79  
1.266  
5
1.000  
5
82  
1.463  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.500  
15  
0.400  
± 12  
0.250  
± 15  
0.200  
(*2)  
W
6
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
5.8  
Mechanical  
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC6-1203Sx-E  
CC6-1205Sx-E  
CC6-1212Sx-E  
CC6-1212Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC12  
DC9.0-18  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
78  
0.423  
3.3  
82  
0.610  
5
85  
0.588  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.500  
15  
0.400  
6
± 12  
0.250  
± 15  
0.200  
1.200  
(*2)  
W
3.96  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
5.8  
Mechanical  
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
ꢀ2  
CC6-E  
MODEL  
CC6-2403Sx-E  
CC6-2405Sx-E  
CC6-2412Sx-E  
CC6-2412Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC24  
DC18-36  
87  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
77  
0.214  
3.3  
81  
0.309  
5
86  
0.291  
0.287  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.500  
15  
0.400  
6
± 12  
0.250  
± 15  
0.200  
1.200  
(*2)  
W
3.96  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
5.8  
Mechanical  
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC6-4803Sx-E  
CC6-4805Sx-E  
CC6-4812Sx-E  
CC6-4812Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC48  
DC36-76  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
77  
0.107  
3.3  
81  
0.154  
5
86  
0.145  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
0.500  
15  
0.400  
6
± 12  
0.250  
± 15  
0.200  
1.200  
(*2)  
W
3.96  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
5.8  
Mechanical  
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
ꢀꢁ  
CC6-E  
Outline Drawing  
CC6-xxxxxF-Eꢀ(DIPꢀtype)  
21.1 0.2  
Shape/Dimensions  
Recommended measurements for mounting board  
20.32  
Outer shape of product  
t=0.3  
7-ø1.0 (land diameter ø2.0)  
17.78  
22.86  
2.54  
2.54  
b
a
2.7  
2-ø1.5 (land diameter ø2.5)  
22.86  
a
b
4
3
2
7-0.3×0.6  
1.0  
5
6
2.7  
Unit: mm  
1
7
a
Allowable tolerance is 0.5 if not specified separately.  
b
CC6-xxxxxR-Eꢀ(SMDꢀtype)  
21.1 0.2  
Shape/Dimensions  
Recommended measurements for mounting board  
Outer shape of product  
t=0.3  
22.86  
Coplanarity: 0.1 or lower  
26.16  
1.8  
1.8  
3
2
4
5
7-0.3×0.6  
3.2  
22.0  
28.4  
3.2  
6
7
1
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
Connection diagram  
CC6-xxxxSx-E  
CC6-xxxxDx-E  
Terminal connections  
No.1 +Vin  
No.2 RC  
No.3 –Vin  
No.4 NC  
No.5 –Vout  
No.6 TRM  
No.7 +Vout  
Terminal connections  
No.1 +Vin  
+Vin  
1
+Vout  
TRM  
+Vin  
1
+Vout  
7
6
5
7
6
5
No.2 RC  
No.3 –Vin  
No.4 –Vout  
No.5 Common out  
No.6 TRM  
No.7 +Vout  
TRM  
COM  
–Vout  
RC  
2
RC  
2
–Vout  
4 NC  
4
3
3
–Vin  
–Vin  
Derating Curve  
100  
80  
60  
40  
20  
0
Natural air cooling  
a
b
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
020406080100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
ꢀ4  
CC10-E  
CC10-E Specifications  
MODEL  
CC10-0503Sx-E CC10-0505Sx-E  
CC10-0512Sx-E  
CC10-0512Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC5.0  
DC4.5-9.0  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
84  
83  
2.313  
1.964  
3.3  
2.381  
5
2.286  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
15  
± 12  
0.400  
± 15  
0.320  
2.500  
8.25  
2.000  
10  
0.800  
0.640  
(*2)  
W
9.6  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
40  
100  
80  
600  
Output  
Temperature Coefficient  
(Ambient temperature -40to +50)  
80mV  
200mV  
300mV  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
10  
Mechanical  
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC10-1203Sx-E CC10-1205Sx-E  
CC10-1212Sx-E  
CC10-1212Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC12  
DC9.0-18  
88  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
84  
0.318  
3.3  
86  
0.969  
5
86  
1.047  
1.136  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
15  
± 12  
450  
± 15  
360  
2.500  
8.25  
2.000  
10  
1000  
800  
(*2)  
W
12  
40  
100  
10.8  
80  
600  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
Output  
Temperature Coefficient  
80mV  
200mV  
300mV  
(Ambient temperature -40to +50)  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
10  
Mechanical  
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
ꢀꢂ  
CC10-E  
MODEL  
CC10-2403Sx-E CC10-2405Sx-E  
CC10-2412Sx-E  
CC10-2412Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC24  
DC18-36  
87  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
84  
0.409  
3.3  
86  
0.484  
5
86  
0.523  
0.575  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
15  
± 12  
0.450  
± 15  
0.360  
2.500  
8.25  
2.000  
10  
1.000  
0.800  
(*2)  
W
12  
40  
100  
10.8  
80  
600  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
Output  
Temperature Coefficient  
80mV  
200mV  
300mV  
(Ambient temperature -40to +50)  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
10  
Mechanical  
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
MODEL  
CC10-4803Sx-E CC10-4805Sx-E  
CC10-4812Sx-E  
CC10-4812Dx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC48  
DC36-76  
88  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
84  
0.205  
3.3  
86  
0.242  
5
86  
0.262  
0.284  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
12  
15  
± 12  
0.450  
± 15  
0.360  
2.500  
8.25  
2.000  
10  
1.000  
0.800  
(*2)  
W
12  
40  
100  
10.8  
80  
600  
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) (*3) mV  
20  
40  
Output  
Temperature Coefficient  
80mV  
200mV  
300mV  
(Ambient temperature -40to +50)  
Max Power Total Regulation (max)(*4)  
± 3  
± 5  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*5) mVp-p  
VDC  
(*6)  
40/120  
30/120  
3.15-3.6  
4.75-6.0  
11.4-15.0  
Available  
± 11.4- ± 15.0  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
10  
Mechanical  
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.  
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).  
(*4) Output voltage includes input change, load change (balanced load), and temperature change.  
(*5) In 50MHz, Ta=25°C.  
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30  
seconds.  
・All specifications are subject to change without notice.  
ꢀꢃ  
CC10-E  
Outline Drawing  
CC10-xxxxxF-Eꢀ(DIPꢀtype)  
Shape/Dimensions  
Recommended measurements for mounting board  
22.6 0.2  
30.48  
Outer shape of  
product  
t=0.3  
7-ø1.0 (land diameter ø2.0)  
25.4  
35.56  
5.08  
25.4  
5.08  
2-ø1.5 (land diameter ø2.5)  
35.56  
a
b
a
b
2.7  
2.7  
3
2
4
5
6
7
7-0.3×0.6  
Unit: mm  
1
b
a
Allowable tolerance is 0.5 if not specified separately.  
1.0  
CC10-xxxxxR-Eꢀ(SMDꢀtype)  
Shape/Dimensions  
Recommended measurements for mounting board  
22.6 0.2  
Outer shape of  
product  
t=0.3  
Coplanarity: 0.1 or lower  
35.56  
38.86  
1.8  
1.8  
3
2
4
5
6
7
3.2  
34.6  
41.0  
3.2  
7-0.3×0.6  
1
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
Connection diagram  
CC10-xxxxSx-E  
CC10-xxxxDx-E  
Terminal connections  
No.1 +Vin  
No.2 RC  
No.3 –Vin  
No.4 NC  
No.5 –Vout  
No.6 TRM  
No.7 +Vout  
+Vin  
+Vout  
Terminal connections  
No.1 +Vin  
No.2 RC  
No.3 –Vin  
No.4 –Vout  
No.5 Common out  
No.6 TRM  
No.7 +Vout  
+Vin  
+Vout  
7
6
5
1
7
6
5
1
TRM  
TRM  
COM  
–Vout  
RC  
2
RC  
–Vout  
2
3
4 NC  
4
3
–Vin  
–Vin  
Derating Curve  
100  
80  
60  
40  
20  
0
Natural air cooling  
a
b
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
020406080100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
ꢀꢄ  
CC15-E  
CC15-E Specifications  
MODEL  
CC15-2403Sx-E  
CC15-2405Sx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC24  
DC18-36  
89  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
0.695  
3.3  
4.500  
14.85  
65  
0.702  
5
3.000  
15  
100  
200  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
(*2)  
W
Maximum Line Regulation(Within input voltage range) mV  
Maximum Load Regulation (0-100% load) mV  
120  
Output  
Temperature Coefficient  
80mV  
(Ambient temperature -40to +50)  
Max Power Total Regulation (max)(*3)  
+5/-3  
40/120  
Not available  
Available  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*4) mVp-p  
(*5)  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
12.5  
Mechanical  
DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) Output voltage includes input change, load change (balanced load), and temperature change.  
(*4) In 50MHz, Ta=25°C.  
(*5) Latch method Resumes by restarting input or resetting remote on/off.  
・All specifications are subject to change without notice.  
ꢀ8  
CC15-E  
Outline Drawing  
CC15-xxxxxSF-Eꢀ(DIPꢀtype)  
Shape/Dimensions  
Recommended measurements for mounting board  
38.1  
32.1  
Outer shape of product  
t=0.3  
6.075  
25.4  
6.075  
37.55  
25-ø1.0 (land diameter ø2.0)  
2-ø1.5 (land diameter ø2.5)  
2.7  
a
b
a
b
10  
9
8
7
6
5
4
3
2
1
11  
12  
13  
14  
15  
16  
1.0  
6.075  
31.475  
17-0.3×0.6  
17  
P=2.54  
Unit: mm  
37.55  
2.7  
b
a
Allowable tolerance is 0.5 if not specified separately.  
CC15-xxxxxSR-Eꢀ(SMDꢀtype)  
Shape/Dimensions  
Recommended measurements for mounting board  
38.1  
32.1  
Outer shape of product  
t=0.3  
40.9  
Coplanarity: 0.1 or lower  
10  
9
8
7
6
5
4
3
2
1
11  
12  
13  
14  
15  
16  
17-0.3×0.6  
17  
3.2  
36.6  
43.0  
3.2  
P=2.54  
1.8  
1.8  
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
Connection diagram  
Terminal connections  
1
17  
RC  
2
3
No.1 NC  
No.2 NC  
No.3 RC  
No.4 NC  
No.5 NC  
No.6 +Vin  
No.7 +Vin  
No.8 –Vin  
No.9 –Vin  
No.10 NC  
No.11 NC  
4
–Vout  
No.12 +Vout  
No.13 +Vout  
No.14 +Vout  
No.15 –Vout  
No.16 –Vout  
No.17 NC  
5
16  
15  
14  
13  
12  
11  
+Vin  
6
7
8
9
+Vout  
–Vin  
10  
Derating Curve  
100  
80  
60  
40  
20  
0
Natural air cooling  
a
b
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
020406080100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
ꢀꢅ  
CC25-E  
CC25-E Specifications  
MODEL  
CC25-2403Sx-E  
CC25-2405Sx-E  
ITEMS/UNITSꢀ  
Nominal Voltage  
V
V
DC24  
DC18-36  
90  
Voltage Range  
Efficiency (typ)  
Current (typ)  
Input  
(*1)  
(*1)  
A
1.146  
3.3  
7.500  
24.75  
65  
1.157  
5
5.000  
25  
100  
200  
Nominal Voltage  
Maximum Current  
Maximum Power  
VDC  
A
(*2)  
W
Maximum Line Regulation (Within input voltage range) mV  
Maximum Load Regulation (0-100% load) mV  
120  
Output  
Temperature Coefficient  
80mV  
(Ambient temperature -40to +50)  
Max Power Total Regulation (max)(*3)  
+5/-3  
Maximum Ripple & Noise (typ/max)  
Voltage Adjustable Range  
Over Current Protection  
(*4) mVp-p  
VDC  
(*5)  
40/120  
Not available  
Available  
Function Over Voltage Protection  
Remote ON/OFF Control  
Operating Temperature  
Not available  
Available  
-40 to +85  
-40 to +85  
RH  
RH  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
5-95 (the conditions of maximum 38in wet bulb temperature and non-condensation should be ensured.)  
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each  
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation  
Environment  
Vibration  
Shock  
Withstand Voltage  
Isolation Resistance  
Standards Safety Standards  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)  
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50Mmin  
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)  
Isolation  
Weight (typ)  
Size (W x H x D)  
g
mm  
20  
Mechanical  
DIP: 42.65 x 7.0 x 44.9 / SMD: 42.65 x 7.5 x 44.9  
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.  
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.  
(*1) With nominal input voltage, maximum output current, and Ta=25°C.  
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.  
(*3) Output voltage includes input change, load change (balanced load), and temperature change.  
(*4) In 50MHz, Ta=25°C.  
(*5) Latch method Resumes by restarting input or resetting remote on/off.  
・All specifications are subject to change without notice.  
20  
CC25-E  
Outline Drawing  
CC25-xxxxSF-Eꢀ(DIPꢀtype)  
Shape/Dimensions  
Recommended measurements for mounting board  
43.2  
44.9  
Outer shape of product  
t=0.3  
6.075  
30.5  
6.075  
42.65  
25-ø1.0 (land diameter ø2.0)  
2-ø1.5 (land diameter ø2.5)  
2.7  
b
a
b
13  
12  
11  
10  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
1.0  
9
8
7
25-0.3×0.6  
a
6.075  
6
5
4
3
2
1
2.7  
36.575  
42.65  
P=2.54  
25  
b
a
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
CC25-xxxxSR-Eꢀ(SMDꢀtype)  
Recommended measurements for mounting board  
Shape/Dimensions  
43.2  
44.9  
Outer shape of product  
t=0.3  
46.0  
Coplanarity: 0.1 or lower  
1.8  
1.8  
13  
12  
11  
10  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
9
8
7
6
5
4
3
2
1
3.2  
41.7  
48.1  
3.2  
P=2.54  
25  
Unit: mm  
Allowable tolerance is 0.5 if not specified separately.  
Connection diagram  
Terminal connections  
No.1 NC  
No.2 NC  
No.3 NC  
No.4 RC  
No.5 NC  
No.6 NC  
No.7 –Vin  
No.8 –Vin  
No.9 –Vin  
1
2
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
–Vout  
No.10 +Vin  
No.11 +Vin  
No.12 +Vin  
No.13 NC  
No.19 –Vout  
No.20 –Vout  
No.21 –Vout  
No.22 –Vout  
No.23 –Vout  
No.24 –Vout  
No.25 NC  
RC  
3
4
5
6
–Vin  
7
No.14 NC  
8
No.15 +Vout  
No.16 +Vout  
No.17 +Vout  
No.18 +Vout  
9
10  
11  
12  
13  
+Vout  
+Vin  
Derating Curve  
100  
Natural air cooling  
a
b
80  
60  
40  
20  
0
a:0.5m/s(100LFM)  
b:1m/s(200LFM)  
-40 -20  
020406080100  
Ambient temperature (°C)  
Output power derating by ambient temperature  
(common specification)  
・All specifications are subject to change without notice.  
21  
CC-E  
CC-E Instruction Manual  
1. Control functions/Protection functions/Connections  
1-2. Output voltage adjusting ter-  
minal (TRM) (1.5-10W type)  
Output voltage can be set to the values shown in the figure  
below by connecting the TRM terminal to the -Vout termi-  
nal.  
1. Remote On/Off terminal (RC)  
1.5-10W type  
Open collector is recommended as the connection system.  
Consult us for use with other systems.  
Use a transistor with "V : Vin or over" and "Ic: 1mA or  
CE  
over".  
When not using this function (always on), set the TRM ter-  
minal to open.  
Output is switched off by setting the RC terminal open, and  
switched on by setting the RC terminal to LOW (0-0.4V).  
Note that when the output voltage is set high by this func-  
tion, derating of output current is necessary according to  
the maximum power.  
+Vin  
+Vout  
RC  
control  
signal  
DIP/SMDmodels  
Model name  
CC–xx03Sx–E  
CC–xx05Sx–E  
CC–xx12Sx–E  
CC–xx12Dx–E  
RC  
Open  
3.3V  
5V  
Connection to -Vout Fig.  
3.6V  
6V  
1
1
1
2
–Vin  
–Vout  
12V  
15V  
±15V  
When not using this function (always on), short-circuit be-  
tween RC terminal and -Vin terminal.  
±12V  
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.  
+Vin  
+Vout  
Fig.1  
+Vin  
When not  
using this  
function  
3.3V  
5V  
12V  
3.6V  
6V  
15V  
+Vout  
TRM  
+Vin  
–Vin  
+Vout  
TRM  
RC  
(always on)  
–Vin  
–Vout  
–Vin  
Fig.2  
+Vin  
–Vout  
–Vout  
15/25W type  
+12V  
+15V  
+Vout  
TRM  
+Vin  
+Vout  
Output is switched on by setting the RC terminal to open,  
and switched off by setting the RC terminal to HIGH (con-  
necting to Vin terminal).  
Load  
TRM  
COM  
–Vout  
Load  
Load  
COM  
–Vout  
Load  
–12V  
–Vin  
–Vin  
–15V  
+Vin  
+Vout  
SIPmodels  
Model name  
CC3–xx03SS–E  
CC3–xx05SS–E  
CC3–xx12SS–E  
CC3–xx12DS–E  
RC  
control  
signal  
RC  
Fig.  
Model name  
3.3V  
Connection to -Vout  
3.67V  
6V  
3
3
3
4
–Vin  
–Vout  
5V  
12V  
15V  
When not using this function (always on), set the RC termi-  
nal to open.  
±12V  
±15V  
Fig.3  
+Vin  
+Vout  
When not  
using this  
function  
RC  
Load  
Fig.4  
Load  
3.3V, 5V, 12V  
3.67V, 6V, 15V  
(always on)  
–Vin  
–Vout  
Load Load  
+12V  
Load Load  
+15V  
–12V  
–15V  
・All specifications are subject to change without notice.  
22  
CC-E  
For ±the 12V output model, output voltage can be set to  
24V single output by making the COM terminal and TRM  
terminal open. And output voltage can be set to 30V single  
output by making the COM terminal open and connecting  
the TRM terminal to the -Vout terminal.  
Adding a resistance Rb between TRM terminal and  
+Vout terminal, to set the output voltage low  
*5 Vout = 3.3 - 15.53/(39.6+Rb) [Rb ≧ 62]  
*6 Vout = 5.01 - 52.55/(31.8+Rb) [Rb ≧ 160]  
*7 Vout = 12.01 - 431.1/(57+Rb) [Rb ≧ 620]  
*8 Vout = 12.02 - 968.5/(103+Rb) [Rb ≧ 1500]  
models  
Model name  
Calculating connected resistance Ra, Rb (kΩ) from set out-  
put voltage Vout (V)  
Adding a resistance Ra between TRM terminal and -Vout  
terminal, to set the output voltage high  
*1 Ra = 9.59/(Vout-3.3) - 32  
COM terminal TRM terminal  
Single output  
Fig.  
Open  
Open  
Open  
Connection to -Vout  
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.  
Fig.5  
+Vin  
Fig.6  
+Vin  
*2 Ra = 17.64/(Vout-5.01) - 17.8  
*3 Ra = 50.53/(Vout-12.01) - 16.9  
*4 Ra = 53.55/(Vout-12.02) - 18  
+Vout  
TRM  
+Vout  
TRM  
30V  
24V  
COM  
–Vout  
COM  
–Vout  
–Vin  
–Vin  
Adding a resistance Rb between TRM terminal and +Vout  
terminal, to set the output voltage low  
*5 Rb = 15.53/(3.3-Vout) - 39.6  
models  
Model name  
COM terminal TRM terminal  
Single output  
Fig.  
Open  
Open  
Open  
*6 Rb = 52.55/(5.01-Vout) - 31.8  
*7 Rb = 431.1/(12.01-Vout) - 57  
Connection to -Vout  
*8 Rb = 968.5/(12.02-Vout) - 103  
Fig.7  
Fig.8  
Fig.9  
Fig.10  
*5,*6,*7  
3.33.6V  
56V  
3.153.3V  
4.755V  
+Vout  
TRM  
+Vout  
TRM  
1215V  
11.412V  
Rb  
Load  
Load  
30V  
24V  
Ra  
–Vout  
–Vout  
*1,*2,*3  
1-3. Output voltage adjusting func-  
tion (adding external resistance)  
(1.5-10W type)  
Fig.11  
Fig.12  
*8  
+12+15V  
+11.4+12V  
+Vout  
TRM  
COM  
+Vout  
TRM  
COM  
Rb  
Load  
Load  
Output voltage can be varied in the range shown in the fig-  
ure below by connecting a resistance (Ra, Rb) between the  
TRM terminal and the -Vout terminal or between the TRM  
terminal and +Vout terminal.  
Note that when the output voltage is set high, derating  
of output current is necessary according to the maximum  
power.  
Load  
Load  
Ra  
*4  
–Vout  
–Vout  
–12–15V  
–11.4–12V  
models  
Connection between  
-Vout and Ra  
Connection between  
+Vout and Rb  
Model name  
Fig.  
Fig.  
to  
to  
to  
to  
to  
to  
to  
models  
to  
Connection between  
-Vout and Ra  
Connection between  
+Vout and Rb  
Model name  
Fig.  
Fig.  
to  
to  
to  
to  
to  
to  
to  
Calculating output voltage Vout (V) from connected resis-  
tance Ra, Rb (kΩ)  
Adding a resistance Ra between TRM terminal and -Vout  
terminal, to set the output voltage high  
*1 Vout = 3.3 + 1.04/(2.83+Ra)  
to  
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.  
Calculating output voltage Vout (V) from connected resis-  
tance Ra, Rb (kΩ)  
*2 Vout = 5 + 12.75/(12.69+Ra)  
Adding a resistance Ra between TRM terminal and -Vout  
terminal, to set the output voltage high  
*1 Vout = 3.3 + 9.59/(32+Ra)  
*3 Vout = 12 + 48.4/(16.18+Ra)  
*4 Vout = 12 + 54.7/(18+Ra)  
*2 Vout = 5.01 + 17.64/(17.8+Ra)  
*3 Vout = 12.01 + 50.53/(16.9+Ra)  
*4 Vout = 12.02 + 53.55/(18+Ra)  
Adding a resistance Rb between TRM terminal and  
+Vout terminal, to set the output voltage low  
*5 Vout = 3.3 - 1.69/(3.66+Rb) [Rb ≧ 7.6]  
*6 Vout = 5 - 12.78/(17.79+Rb) [Rb ≧ 33.3]  
*7 Vout = 12 - 184.1/(35.54+Rb) [Rb ≧ 271.3]  
*8 Vout = 12 -470.3/(61.75+Rb) [Rb ≧ 722.1]  
・All specifications are subject to change without notice.  
23  
CC-E  
Calculating connected resistance Ra, Rb (kΩ) from set out-  
put voltage Vout (V)  
1-5. Over voltage protection  
Adding a resistance Ra between TRM terminal and -Vout  
terminal, to set the output voltage high  
*1 Ra = 1.04/(Vout-3.3) - 2.83  
An over voltage protection function is not incorporated in  
the model. Be careful if an external voltage over the nomi-  
nal voltage is applied, damage may be caused.  
*2 Ra = 12.75/(Vout-5) - 12.69  
*3 Ra = 48.4/(Vout-12) - 16.18  
*4 Ra = 54.7/(Vout-12) - 18  
1-6. Low input voltage protection  
This series is equipped with the low input voltage protec-  
tion in order to prevent malfunction due to low input volt-  
age. The converter stops operation if the input voltage  
become lower than the set voltage. The set ranges are  
shown in the table below.  
Adding a resistance Rb between TRM terminal and  
+Vout terminal, to set the output voltage low  
*5 Rb = 1.69/(3.3-Vout) - 3.66  
*6 Rb = 12.78/(5-Vout) - 17.79  
*7 Rb = 184.1/(12-Vout) - 35.54  
Model name  
Input voltage range  
Voltage range set for protection circuit  
to  
to  
to  
to  
to  
to  
to  
to  
to  
to  
to  
*8 Rb = 470.3/(12-Vout) - 61.75  
Fig.13  
Fig.14  
to  
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.  
Ra  
Rb  
*1,*2,*3  
*5,*6,*7  
Load  
Load  
3.33.67V56V1215V  
1-7. Insulation withstand voltage  
3.153.3V4.755V11.412V  
The insulation withstand voltage between input and output,  
and between terminal and case, is AC500V.  
Fig.15  
Fig.16  
1-8. Series/Parallel connections  
Series connection  
Rb  
Ra  
*4  
*8  
Load Load  
Load Load  
+12+15V  
–12–15V  
–11.4–12V  
+11.4+12V  
Serial connection is applicable by wiring as shown in the  
figure below (left). If output voltage is not generated by this  
connection, connect a Schottky diode in which the forward  
voltage is possibly low.  
1-4. Over current protection  
1.5-10W type  
An over current protection circuit is incorporated in the  
model, and if over current occurs, the output voltage is  
lowered. By removing the over current and shorted condi-  
tions, the output voltage automatically resumes. Note that  
if the over current status continues for 30 seconds or over,  
the internal elements of the converter may be deteriorated  
or damaged. The current value, from which it is judged as  
an over current, is not to be lower than the nominal current  
value. If the output voltage does not resume even after re-  
moving the over current conditions and any causes, turn off  
the power or remote control once, and then restart it.  
Also note that the Schottky diode should have a reverse  
voltage that is twice or over the value of the voltage be-  
tween +Vout and -Vout.  
And the output current should be the same or lower than  
the nominal current value, whichever is smaller in the con-  
verters.  
+Vin  
+Vout  
+Vin  
+Vout  
–Vin  
+Vin  
–Vout  
+Vout  
–Vin  
+Vin  
–Vout  
+Vout  
15/25W type  
–Vin  
–Vout  
–Vin  
–Vout  
An over current protection circuit is incorporated in the  
model, and if over current occurs, the output voltage is  
lowered and the converter is stopped and latched. The  
output voltage does not automatically resume even after  
removing the over current and shorted conditions.  
To resume output voltage, restart input or reset remote on/  
off.  
Parallel connection  
Parallel connection is not applicable.  
The current value, from which it is judged as an over cur-  
rent, is not to be lower than the nominal current value.  
・All specifications are subject to change without notice.  
24  
CC-E  
2. Noise reduction methods  
2-1. Ripple noise measurement method  
2-3. Output ripple & noise  
The measured value of the converter noise may differ de-  
pending on the measurement method. Measurement should  
be conducted in a position close to the output terminal.  
When connecting a prove, do not allow a loop to be config-  
ured in order not to pick up flux.  
To reduce Output ripple & noise, connect a capacitor to  
the output of the converter. In addition, reduction can be  
enhanced if a π type filter is incorporated as shown in the  
figure below. In this case, use of a coil with around 100µH  
is recommended.  
As well, note that the spike voltage greatly differs depend-  
ing on the ripple voltmeter and frequency band of the oscil-  
loscope.  
+Vin  
+Vout  
+Vin  
+Vout  
Our noise measurement is conducted by the wiring shown  
in the figure below and in the frequency band of 50MHz.  
–Vin  
–Vout  
–Vin  
–Vout  
10mm  
20mm  
When the distance to the load from the output of the con-  
verter is long, connect the capacitor as close as possible  
to the load.  
To reduce output spike noise, connect a ceramic capacitor  
with around 1µF to the output of the converter.  
A
lout  
+Vin  
+Vout  
–Vout  
Vout  
V
0.1µF  
Vin  
V
Iin  
50Ω coaxial cable  
–Vin  
A
1.5m  
Ripple  
Oscilloscope  
+Vin  
–Vin  
+Vout  
–Vout  
or  
voltmeter  
50MHz  
50MHz  
End-point: 50Ω+0.1µF  
1MF  
2-2. Input ripple noise  
This series is equipped with a built-in capacitor for input.  
Therefore, this series can operate without an external  
capacitor connected to input. However, by connecting a  
capacitor, input ripple noise and input return noise can be  
reduced.  
2-4. Capacity of external capaci-  
tor connected to output  
Note that if a capacitor with capacity over the value shown  
in the table below is connected to the output, or several  
capacitors with low impedance are connected in parallel,  
operation of the converter may become unstable.  
In addition, it is more effective if a π type filter is installed  
as shown in the figure below.  
+Vin  
+Vout  
+Vin  
+Vout  
Model name  
Electrostatic capacitance (µF) max.  
–Vin  
–Vout  
–Vin  
–Vout  
When the distance to the input of the converter from the  
input power supply is long, attach a capacitor as close as  
possible to the input terminal.  
+Vin  
+Vout  
–Vin  
–Vout  
When the distance to the input of the converter from the  
input power supply is long, the impedance of the input line  
can become high, causing high spike noise.  
In this case, it is recommended to connect a capacitor as  
close as possible to the input of the DC-DC converter.  
・All specifications are subject to change without notice.  
25  
CC-E  
2-5. Common mode noise  
2-6. Radiation noise  
For products other than with 10W, capacitors are not con-  
nected between the primary GND and the secondary GND.  
To reduce common mode noise, connect a capacitor with  
around 1000pF between the primary GND and the second-  
ary GND, as shown in the figure below.  
In this case, note that if the capacitor that is connected is  
too large, coupling capacitance between input and output  
becomes large.  
Radiation noise of the converter can be reduced by con-  
necting the case terminal to the input or output GND ter-  
minal. The effectiveness varies depending on the device.  
Check it on the actual device.  
Regarding wiring, use GND line and solid pattern for the  
bottom of the converter as much as possible.  
- SMD models are not equipped with case terminals.  
Also be careful about the withstand voltage of the capacitor  
(500V or over is desirable with consideration of the insula-  
tion withstand voltage).  
+Vin  
+Vout  
–Vin  
–Vout  
For products with 10W, capacitors with 1000pF are inter-  
nally connected between primary and secondary.  
3. Soldering conditions/Cleaning conditions  
3-1. Soldering conditions  
3-2. Cleaning method  
Board cleaning after soldering is not recommended. How-  
ever, the cleaning fluids and conditions shown in the table  
below have been tested and proved to have no problem.  
These fluids and conditions can be used. Consult us for  
using cleaning fluids other than those shown below.  
●Soldering conditions  
ꢀDIP models / SIP models  
Observe the following conditions in soldering board.  
Solder dip  
260°C, 10s max.  
Soldering copper  
380°C, 3s max.  
Cleaning fluids and test conditions  
Cleanthrough 750H  
SMD models  
Lead-free soldering / High-temperature reflow process  
(1) Cleaning (shaking) at 60°C for 4 minutes  
(2) Rinsing (shaking in water) at 60°C for 4 minutes  
(3) Rinsing (shaking in water) at ordinary temperature -  
40°C for 4 minutes  
30p20s  
Surface temperature of parts  
245˚C max.  
225˚C min.  
(4) Drying at 70°C for 6 minutes  
180˚C  
150˚C  
Pine alpha ST100S  
(1) Cleaning (shaking) at 60°C for 5 minutes  
(2) Rinsing (shaking in water) at 30°C for 3 minutes  
(3) Drying at 70°C for 6 minutes  
1 to 3˚C/s 40 to 100s 1 to 4˚C/s 1 to 5˚C/s  
Terpene Cleaner EC-7R  
(1) Cleaning (shaking) at 60°C for 5 minutes  
(2) Rinsing (shaking in IPA) at 30°C for 10 minutes  
(3) Drying at 70°C for 6 minutes  
Isopropyl alcohol  
(1) Ultrasonic waves at 60°C for 1 minute  
(2) Cool bath cleaning R.T. for 1 minute  
(3) Vapor cleaning at 83°C for 1 minutes  
Asahiklin AK-225AES  
(1) Ultrasonic waves at 50°C for 2 minutes  
(2) Cool bath cleaning R.T. for 2 minutes  
・All specifications are subject to change without notice.  

相关型号:

CC10-0505SF-E

Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters
TDK

CC10-0505SR-E

DC-DC Regulated Power Supply Module, 1 Output, 10W, ROHS COMPLIANT, SMD-25
TDK

CC10-0512DF-E

Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters
TDK

CC10-0512DR-E

Insulation type DC-DC converter
TDK

CC10-0512SF-E

Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters
TDK

CC10-0512SR-E

Insulation type DC-DC converter
TDK

CC10-10000NF-RC

General Purpose Inductor,
ALLIED

CC10-10000NG-RC

General Purpose Inductor,
ALLIED

CC10-10000NJ-RC

Ceramic Core Chip Inductors
ALLIED

CC10-10000NK-RC

General Purpose Inductor,
ALLIED

CC10-1000NF-RC

General Purpose Inductor,
ALLIED

CC10-1000NG-RC

General Purpose Inductor,
ALLIED