SP100 [SYSTEMSENSOR]
Speakers; 音箱型号: | SP100 |
厂家: | SYSTEMSENSOR ADVANCED IDEAS. |
描述: | Speakers |
文件: | 总4页 (文件大小:350K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SP100 and V400 Series
Speakers and
Speaker/Strobes
A Division of Pittway
3825 Ohio Avenue, St. Charles, IL 60174
1-800-SENSOR2 (736-7672), Fax 630-377-6495
http://www.systemsensor.com
V400 Speaker
SP101 Speaker
with ADA Strobe
SP100 Speaker
Features
• Dual voltages: 25 and
70.7 Vrms
• Multiple strobe options
–ADA/UL 1971 @ 15,
15/75, 75, or 110 cd
(24 VDC only)
• Listed to UL Standard
1480 for speakers for fire
protective signaling
systems
• Multiple selectable taps
–SP100: 1/8 – 4 watts
–V400: 1/4 – 2 watts
• Peak dBA:
–SP100: 96 @ 4 watts
–V400: 90 @ 2 watts
System Sensor SP100 Series and V400 Series Speakers
are the Sound ChoiceTM for voice, tone, and visible
signaling. The SP100 Series are high quality speakers and
speaker/strobe combinations for evacuation signaling
designed to meet UL1480 Fire Standard Specifications.
Sound Choice speakers are available with ADA/UL1971
listed strobes for public mode applications.
Specifications – SP100 Series
Mechanical
Electrical
Input Terminals:
Grille Size/Color:
Round:
Square:
Weight:
12 to 18 AWG
Voltage Input:
Frequency Range:
25 volts or 70.7 volts (nominal)
400 – 4000 Hz
8″ (203 mm)/white
5″ (127 mm)/red or white
1.6 lb (725 gm)
Although the SP100 Series speaker/strobe combination is
sold as a unit, the speaker and strobe are electrically
independent and require separate power sources. See chart
on page 2 for strobe operating requirements.
Mounting:
4″ × 4″ × 21/
8
″ backbox with
4″ × 4″ × 11/
2
″ extension ring
Filler Plugs:
Included
Operating
Temperature Range:
32° to 120°F (0° to 49°C)
APPROVED
© System Sensor 9/97
This document is not intended to be used for installation purposes.
A05-191-04
SP100 Series Speaker/Strobe Power Requirements
SP1W2415ADA
SP1R2415ADA
20–30 VDC
75 mA
SP1W241575ADA
SP1R241575ADA
20–30 VDC
SP1W2475ADA
SP1R2475ADA
20–30 VDC
SP1W24110ADA
SP1R24110ADA
20–30 VDC
Supply Voltage:
Max. Current @ Listed Voltage:
Operating Current
93 mA
170 mA
210 mA
@ Rectified Unfiltered Voltage:
Rated Light Output
90 mA
15.0 cd
120 mA
15/75 cd
200 mA
75.0 cd
245 mA
110.0 cd
Specifications – V400 Series
Mechanical
Operating
Input Terminals:
Grille Size/Color:
Weight:
14 to 18 AWG
4″ (102 mm)/red or beige
.7 lb (317 gm)
Temperature Range:
32° to 120°F (0° to 49°C)
Electrical
Voltage Input:
Frequency Range:
Mounting:
25 volts or 70.7 volts (nominal)
400 – 4000 Hz
Semiflush*:
4″ × 4″ × 11/
2
″–21/
″
8
standard backbox**
Flush*:
deep backbox (BBD) with
flush mounting plate
*Order mounting plates separately.
**For 12- or 14-gauge wire, a 21/
mended.
8″ backbox is recom-
Engineering Specifications
Speaker shall be a System Sensor Model ______ dual
transformer speaker capable of operating at 25 and 70.7
operating at 25 and 70.7 Vrms. Speaker/strobe shall be
listed to Underwriter’s Laboratories Standard 1480 for fire
Vrms. Speaker shall be listed to Underwriter’s Laboratories protective signaling systems. Speaker shall have a
Standard 1480 for fire protective signaling systems.
Speaker shall have a frequency range of 400 to 4000 Hz
and shall have an operating temperature between 32° and
120°F. Speaker shall have power taps which are selected
by means of a jumper wire(s).
frequency range of 400 to 4000 Hz and shall have an
operating temperature between 32° and 120°F. Speaker
shall have power taps which are selected by means of a
jumper wire(s). Strobe shall be powered independently of
the speaker and shall operate from a 24 VDC or 24 Vrms
full wave rectified unfiltered power supply. Strobe shall
have a light output rating of 15, 75, or 110 candela and
shall be UL 1971 listed as a primary signaling device.
For speaker/strobe combination:
Speaker/strobe shall be a System Sensor Speaker/Strobe
Model ______ dual transformer speaker capable of
Page 2
A05-191-04
Power Tap Selection and Sound Output
SP100*
V400
1
1
1
1
1
4
4 W
1 B
2 W
1 A
3 B
1 W
2 B
4 B
/
2
W
/
4
W
/
8
W
2
–
–
1
–
–
/
2
/
Jumper Wire, 25 V:
Jumper Wire, 70.7 V:
UL Reverberant
(dBA @ 10 ft):
Anechoic
2 A
5 B
3 B
6 B
4 B
6 A
–
–
–
–
2 A
90
93
96
87
90
93
84
87
90
81
84
87
78
81
84
75
78
81
84
87
90
81
84
87
78
81
84
75
78
81
(dBA @ 10 ft):
Peak Anechoic
(dBA @ 10 ft):
* Example: To select 1/
watt output @ 25 V connect blue lead to post #3, yellow to post B.
4
Power Tap Selection
2W
1W
1/4W
1/2W
RED
TO
STROBE
BLADE
BLACK
TO
STROBE
BLADE
FROM
PANEL OR
PREVIOUS
DEVICE
COM 25 70.7
TO
NEXT
DEVICE
OR
STROBE
EOL
TO
NEXT
DEVICE
OR
25 OR
70.7V
EOL
SP100
V400
4″×4″×21/8″
BACKBOX
MP-SF
8-32x5/8
4″×4″×11/2″
EXTENSION RING
#8
NUTS
8-32
SCREWS
V400
8-32x5/8
#8 S.M.
FILLER
PLUGS
STROBE/SPEAKER
(SP101 SERIES)
8-32X1-7/16
#8 S.M.
SP101 Mounting Diagram
8-32X1-7/16
V400 Semiflush Mounting Diagram
Page 3
A05-191-04
Ordering Information – Sound ChoiceTM Speakers
Speaker
Voltage
Strobe
Voltage
Description
Candela
SP100 Series Speakers
Red
–
White
SP100W
Round, 8″ grille, 1/
8
–4 watt power taps
–4 watt power taps
25/70.7 Vrms
25/70.7 Vrms
–
–
–
–
SP101R
SP1R2415ADA
SP1R241575ADA SP1W241575ADA
SP1R2475ADA SP1W2475ADA
SP1R24110ADA SP1W24110ADA
SP101W
SP1W2415ADA
Square, 5″ grille, 1/
Square, 5″ grille, 1/
Square, 5″ grille, 1/
Square, 5″ grille, 1/
Square, 5″ grille, 1/
8
8–4 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
8–4 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
8–4 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
8–4 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
24 VDC
24 VDC
24 VDC
24 VDC
15 cd
15/75 cd
75 cd
110 cd
V400 Series Speakers
Red
V400R
Beige
V400B
–
–
–
–
White
V400W
–
–
–
–
Square, 4″ grille, 1/
Square, 4″ grille, 1/
Square, 4″ grille, 1/
Square, 4″ grille, 1/
Square, 4″ grille, 1/
4
4
4
4
4
–2 watt power taps
25/70.7 Vrms
–
–
V4R2415ADA
V4R241575ADA
V4R2475ADA
V4R24110ADA
MP-F
–2 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
–2 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
–2 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
–2 watt power taps, wall strobe, UL 1971 25/70.7 Vrms
24 VDC
24 VDC
24 VDC
24 VDC
15 cd
15/75 cd
75 cd
110 cd
MP-FB
–
MP-FW
–
Flush mounting plate
Flush mounting deep backbox, 23/
BB-D
4″ deep
MP-SF
MP-SFB
MP-SFW
Semi-flush mounting plate
UL 1638 Strobe attachments for V400*
Red
Beige
SS12LO
SS24LO
SS24LOC
SS24M
SS24MC
–
Signal strobe
Signal strobe
Ceiling mount signal strobe
Signal strobe
Ceiling mount signal strobe
–
–
–
–
–
12 VDC
24 VDC
24 VDC
24 VDC
24 VDC
1.5 cd
1.5 cd
1.5 cd
15 cd
15 cd
SS24LOB
–
–
–
* Although the SSLO and SSM Series signal strobes are UL listed as primary signaling devices, when combined with the V400 speaker they are consid-
ered as a secondary signaling device only.
How to Order SP100 Series Speakers with Strobes
SP1R2415ADA
15 = 15 cd, UL 1971 Strobe
1575 = 15 cd, UL 1971, 75 cd on axis
75 = 75 cd, UL 1971 Strobe
110 = 110 cd, UL 1971 Strobe
24 = 24 VDC Strobe
SP1R = Square Grille, Red Speaker
SP1W = Square Grille, White Speaker
V4R = V400 Square, Red Speaker
System Sensor Worldwide Manufacturing & Distribution
In Canada:
In the Far East:
In Italy:
Telephone: 905-812-0767
Fax: 905-812-0771
Telephone: 852-2191-9003
Fax: 852-2736-6580
Telephone: 39-40-9490-111
Fax: 39-40-382137
In China:
Telephone: 852-2191-9003
Fax: 852-2736-6580
In India:
Telefax: 91-022-8202564
In the United Kingdom:
Telephone: 44-1403-276500
Fax: 44-1403-276501
Page 4
A05-191-04
相关型号:
©2020 ICPDF网 联系我们和版权申明