PQ60150SMw03xyS
更新时间:2024-09-18 22:12:14
品牌:SYNQOR
描述:Output current limit and short circuit protection
PQ60150SMw03xyS 概述
Output current limit and short circuit protection
PQ60150SMw03xyS 数据手册
通过下载PQ60150SMw03xyS数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Technical
Specification
PQ60150SMx03
35-75V
100V
Transient Input
15V
Output
45W
Max Power
2250V dc
Sixteenth-Brick
Input
Isolation
DC-DC Converter
The PQ60150SMx03 PowerQor® Mega sixteenth brick
converter is a next-generation, board-mountable, isolated,
fixed switching frequency DC/DC converter that uses
synchronous rectification to achieve extremely high
conversion efficiency. The power dissipated by the converter
is so low that a heatsink is not required, which saves cost,
weight, height, and application effort. All of the power and
control components are mounted to the multi-layer PCB
substrate with high-yield surface mount technology. Since
the PowerQor converter has no explicit thermal interfaces, it
is extremely reliable. RoHS compliant (see page 15).
Operational Features
• High efficiency, xx% at full rated load current
• Delivers up to 45W of output power with minimal derating
PQ60150SML03 Module
• Operating input voltage range: 35-75Vdc, with 100V for 100ms input
transient capability
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
Protection Features
• Output current limit and short circuit protection
• Active back bias limit
• Output over-voltage protection
Mechanical Features
• Industry standard sixteenth-brick pin-out configuration
• Size: 0.95" x 1.35" (24.1 x 34.3 mm)
• Height: .327" (8.3mm) low profile and .397" (10.1mm) standard
• Weight: .476oz (13.5g)
Control Features
• On/Off control referenced to input side (positive and negative logic
options are available)
• Remote sense for the output voltage compensates for output
distribution drops
• Output voltage trim permits custom voltages and voltage margining
Safety Features
• 2250V input-to-output isolation
• UL 60950-1:2003
• CAN/CSA-C22.2 No. 60950-1:2003
• EN60950-1:2001
• Needle Flame Test (IEC 695-2-2)
• IEC 61000-4-2
• RoHS compliant (see last page)
Contents
Page No.
PQ60-SMA & SML Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . 2
PQ60-SMC Mechanical Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
PQ60150SMx03 ELECTRICAL CHARACTERISTICS . . . . . . . . . . . . . . . . 4-5
PQ60150SMx03 Standards & Qualification Testing . . . . . . . . . . . . . . . . 6
PQ60150SMx03 Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 1
Technical
Specification
PQ60150SMx03
Mechanical Drawing
.95 [24.1]
.600 [15.24]
.450 [11.43]
.300 [7.62]
.150 [3.81]
OVERALL HEIGHT
Low Profile
.327 [8.31]
6
4
8
7
5
.145
[3.68]
1.35
[34.3]
1.10
[27.9]
SIDE VIEW
TOP VIEW
.100
[2.54]
1
2
3
.18 [4.4]
.300 [7.62]
.600 [15.24]
BOTTOMSIDE CLEARANCE
Low Profile
.027 ±.015 [0.69 ±0.38]
PIN DESIGNATIONS
NOTES
1)
2)
3)
4)
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
Pin Name Function
diameter standoff shoulders.
1
2
Vin(+) Positive input voltage
TTL input to turn converter on and off,
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
ON/OFF
referenced to Vin(–), with internal pull up.
Other pin extension lengths available. Recommended pin length is
0.03” (0.76mm) greater than the PCB thickness.
3
4
Vin(–) Negative input voltage
Vout(–) Negative output voltage
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over
Nickel plate
5 SENSE(–) Negative remote sense(see note 1)
TRIM Output voltage trim (see note 2)
7 SENSE(+) Positive remote sense (see note 3)
Vout(+) Positive output voltage
Notes:
5)
6)
Undimensioned components are shown for visual reference only.
All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x
+/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm)
6
7)
8)
9)
Weight: .476oz (13.5g)
8
Workmanship: Meets or exceeds IPC-A-610C Class II
Open frame units have flanged pins are designed to permit surface
mount soldering (avoid wave solder) using PiP technique.
SENSE(–) should be connected to Vout(–) either remotely or at
the converter.
1)
2) Leave TRIM pin open for nominal output voltage.
SENSE(+) should be connected to Vout(+) either remotely or at
the converter.
3)
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 2
Technical
Specification
PQ60150SMx03
PQ60-SMC Mechanical Drawing
1.036±.020 (26.31±0.5)
.600 (15.24)
.450 (11.43)
.300 (7.62)
0.500±.025
(12.7±0.63)
Overall height
.150 (3.81)
8 7 6 5 4
0.18
(4.6)
Top View
1.436±.020
(36.47±0.5)
Side View
1.10
(27.9)
3
1
2
.143±.020
(3.63±0.5)
.300 (7.62)
.218±.020
(5.54±0.5)
.600 (15.24)
NOTES
PIN DESIGNATIONS
1)
2)
3)
4)
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
Pin
Name Function
Vin(+) Positive input voltage
1
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
TTL input to turn converter on and off, referenced to
Vin(–), with internal pull up.
2
ON/OFF
Other pin extension lengths available. Recommended pin length is
0.03” (0.76mm) greater than the PCB thickness.
3
Vin(–)
Negative input voltage
4
Vout(–) Negative output voltage
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over
Nickel plate
5
SENSE(–) Negative remote sense(see note 1)
5)
6)
Undimensioned components are shown for visual reference only.
6
TRIM
Output voltage trim (see note 2)
All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x
+/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm)
7
8
SENSE(+) Positive remote sense (see note 3)
Vout(+) Positive output voltage
7)
8)
Weight: 1.14oz (32.3g)
Notes:
Workmanship: Meets or exceeds IPC-A-610C Class II
SENSE(–) should be connected to Vout(–) either remotely or at
the converter.
1)
2)
3)
Leave TRIM pin open for nominal output voltage.
SENSE(+) should be connected to Vout(+) either remotely or at
the converter.
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 3
Input48V
Output15V
Current3A
Technical Specification
PQ60150SMx03 ELECTRICAL CHARACTERISTICS
Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
ABSOLUTE MAXIMUM RATINGS
Min.
Typ.
Max. Units Notes & Conditions
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage
100
80
100
V
V
V
Continuous
Continuous
100ms transient
Input to Output
Operating Temperature
Storage Temperature
2250
100
125
8
V dc
°C
°C
V
Input to output
-40
-55
-2
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
No-Load Input Current
Disabled Input Current
Response to Input Transient
Input Reflected Ripple Current
Input Terminal Ripple Current
Recommended Input Fuse
Recommended External Input Capacitance
Input Filter Component Values (L\C)
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
35
48
75
V
31.2
28.9
32.5
30.5
2.0
33.8
32.2
V
V
V
1.5
90
14
A
100% Load, Vin min, nominal Vout
0
75
10
90
3
mA
mA
mV
mA
mA
A
1000V/ms input transient
RMS thru 10μH inductor; Figures 13 & 15
RMS; Figures 13 & 14
40
20
100
1.0/2.35
µF
Typical ESR 0.1-0.2 Ω
µH/µF Internal values; see Figure E
14.85
15
15.15
V
±0.1/15
±0.1/15
+0.3/45
+0.3/45
225
%/mV
%/mV
mV
Over Load
Over Temperature
-225
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
14.625
15.375
V
Over sample, line, load, temperature & life
20 MHz bandwidth; Figures 13 & 16; see Note 1
Full load
60
12
120
35
3
mV
mV
A
A
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance Ceramic
EFFICIENCY
0
3.3
Subject to thermal derating; Figures 5 - 8
Figure 17
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load); See Note 2
3.5
3
2
4.2
mA
mF
1.2
100% Load
88
85
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (email: support@synqor.com)
Note 2: Recommended minimum output capacitance is 100uF
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 4
Input48V
Output15V
Current3A
Technical Specification
PQ60150SMx03 ELECTRICAL CHARACTERISTICS
Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Step Change in Output Current (2 A/µs)
Settling Time
60
dB
120 Hz; Figure 20
150
125
300
mV
mV
µs
50% to 75% to 50% Iout max; Figure 11
50% to 75% to 50% Iout max; Figure 12
To within 1% Vout nom
Turn-On Transient
Turn-On Time
35
200
2
ms
ms
ms
%
Full load, Vout=90% nom.
Figure F; See Note 1
Start-Up Inhibit Time
180
250
Power-Up Inhibit Time
Figure F
Output Voltage Overshoot
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
0
Max output capacitance and full load
2250
30
MΩ
Isolation Capacitance (input to output)
1000
pF
See Note 2
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
125
125
125
°C
°C
°C
Package rated to 150 °C
UL rated max operating temp 130 °C
See Figure 2 for derating curve
Transformer Temperature
FEATURE CHARACTERISTICS
Switching Frequency
315
350
385
kHz
ON/OFF Control (Option P)
On-State Voltage
2.4
-2
8
V
V
Off-State Voltage
0.8
ON/OFF Control (Option N)
On-State Voltage
-2
0.8
8
V
V
Off-State Voltage
2.4
ON/OFF Control (Either option)
Pull-Up Voltage
Figures A & B
4.5
-10
18
5
5.5
V
kΩ
%
%
V
Pull-Up Resistance
10
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
Over-Temperature Shutdown OTP Trip Point
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia) TR-NWT-000332
Calculated MTBF (MIL-217) MIL-HDBK-217F
Field Demonstrated MTBF
10
10
20
Measured across Pins 8 & 4; Figure C
Measured across Pins 8 & 4
18.5
125
10
Over full temp range
°C
°C
Average PCB Temperature; Auto Recovery
6
3.9
10 Hrs.
6
3.5
10 Hrs.
6
10 Hrs. See our website for details
Note 1: Minimum value is 30ms for DC current limit and short circuit fault conditions
Note 2: Higher values of isolation capacitance can be added external to the module.
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 5
Input48V
Output15V
Current3A
Technical Specification
PQ60150SMx03 Standards & Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1:2003
Basic Insulation
CAN/CSA-C22.2 No. 60950-1:2003
EN60950-1:2001
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
# Units Test Conditions
32
5
95% rated Vin and load, units at derating point, 1000 hours
Vibration
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
5
10
5
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
5
5
Solderability
15 pins MIL-STD-883, method 2003
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 6
Input48V
Output15V
Current3A
Technical Specification
100
95
90
85
80
75
70
65
60
89
88
87
86
85
84
83
25º C
40º C
55º C
35Vin
48 Vin
75 Vin
100
200
Air Flow (LFM)
300
400
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
Figure 2: Efficiency at nominal output voltage and 60% rated power
vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C
(nominal input voltage).
10
8
8
7
6
5
6
4
4
25º C
35Vin
2
0
40º C
3
48 Vin
75 Vin
55º C
2
100
200
300
400
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Load Current (A)
Air Flow (LFM)
Figure 3: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
Figure 4: Power dissipation at nominal output voltage and 60% rated
power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and
55°C (nominal input voltage).
5
4
3
2
400LFM(2.0m/s)
1
0
300LFM(1.5m/s)
200LFM(1.0m/s)
100LFM(0.5 m/S)
25
40
55
70
85
Ambient Air Temperature(°C)
Figure 5: Maximum output power derating curves vs. ambient air
temperature for airflow rates of 100 LFM through 400 LFM with air
flowing from pin 3 to pin 1 (nominal input voltage).
Figure 6: Thermal plot of converter at 3.0 amp load current (45W) with
55°C air flowing at the rate of 200 LFM. Air is flowing from pin 3 to pin
1 (nominal input voltage).
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 7
Input48V
Output15V
Current3A
Technical Specification
5
4
3
2
400LFM(2.0m/s)
300LFM(1.5m/s)
1
0
200LFM(1.0m/s)
100LFM(0.5 m/S)
25
40
55
Ambient Air Temperature(°C)
70
85
Figure 7: Maximum output power derating curves vs. ambient air
temperature for airflow rates of 100 LFM through 400 LFM with air
flowing lenghtwise from input to output (nominal input voltage).
Figure 8: Thermal plot of converter at 3.0 amp load current (45W)
with 55°C air flowing at the rate of 200 LFM. Air is flowing across the
converter from input to output (nominal input voltage).
Figure 9: Turn-on transient at full load (resistive load) (10 ms/div). Input
voltage pre-applied. Top Trace: Vout (10V/div). Bottom Trace: ON/OFF
input(5V/div)
Figure 10: Turn-on transient at zero load (10 ms/div). Top Trace: Vout
(10V/div). Bottom Trace: ON/OFF input (5V/div)
Figure 11: Output voltage response to step-change in load current (50%-75%-50%
of Iout(max); dI/dt = 0.1A/µs). Load cap: 100µF electrolytic output capacitance.
Top trace: Vout (200mV/div). Bottom trace: Iout (1A/div).
Figure 12: Output voltage response to step-change in load current (50%-
75%-50% of Iout(max): dI/dt = 2A/µs). Load cap: 330µF electrolytic output
capacitance. Top trace: Vout (200mV/div). Bottom trace: Iout (1A/div).
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 8
Input48V
Output15V
Current3A
Technical Specification
See
Fig.
15
See
Fig.
14
10µH
source
impedance
See
Fig.
16
DC/DC
Converter
V
out
1µF
ceramic
capacitor
100µF
100mΩ
ESR
electrolytic
capacitor
100µF
V
source
< 1Ω ESR
electrolytic
capacitor
Figure 14: Input Terminal Ripple Current, ic, at full rated output current
and nominal input voltage with 10µH source impedance and 100µF
electrolytic capacitor (Ch1 100mA/div). (See Figure 13).
Figure 13: Test set-up diagram showing measurement points for Input
Terminal Ripple Current (Figure 14), Input Reflected Ripple Current
(Figure 15) and Output Voltage Ripple (Figure 16).
Figure 16: Output voltage ripple at nominal input voltage and rated load
current (50 mV/div). Load capacitance: one 1.0µF ceramic capacitor and
one 100µF electrolytic capacitor. Bandwidth: 20 MHz. (See Figure 13).
Figure 15: Input reflected ripple current, is, through a 10 µH source
inductor at nominal input voltage and rated load current (5 mA/div). (See
Figure 13).
30
25
20
15
10
35Vin
5
0
48Vin
75 Vin
0
1
2
3
4
5
6
Load Current (A)
Figure 17: Output voltage vs. load current showing typical current limit
curves and converter shutdown points.
Figure 18: Load current (10A/div) as a function of time when the
converter attempts to turn on into a 1 mΩ short circuit. Top trace (10ms/
div) is an expansion of the on-time portion of the bottom trace.
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 9
Input48V
Output15V
Current3A
Technical Specification
10
0
-20
1
-40
0.1
-60
0.01
0.001
0.0001
-80
35Vin
48Vin
75Vin
35Vin
48Vin
75Vin
-100
-120
10
100
1,000
Hz
10,000
100,000
10
100
1,000
Hz
10,000
100,000
Figure 19: Magnitude of incremental output impedance (Zout = vout/iout)
for minimum, nominal, and maximum input voltage at full rated power.
Figure 20: Magnitude of incremental forward transmission (FT = vout/
vin) for minimum, nominal, and maximum input voltage at full rated
power.
10
0
1000
100
10
-10
-20
-30
35Vin
35Vin
48Vin
75Vin
1
-40
-50
48Vin
75Vin
0.1
10
100
1,000
Hz
10,000
100,000
10
100
1,000
Hz
10,000
100,000
Figure 22: Magnitude of incremental input impedance (Zin = vin/iin) for
minimum, nominal, and maximum input voltage at full rated power.
Figure 21: Magnitude of incremental reverse transmission (RT = iin/iout)
for minimum, nominal, and maximum input voltage at full rated power.
12
10
8
6
4
2
0
-2
-4
+85°C
+25°C
-40°C
-6
-8
-10
-12
39
38.5
38
37.5
37
36.5
36
35.5
35
Input Voltage (V)
Figure 23: Achievable trim-up percentage vs. input voltage at +85°C,
+25°C, and -40°C (all at full load). Full trim-up percentage is achieved
at loads of 50% or less across full temperature and input voltage range.
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 10
Technical
Specification
PQ60150SMx03
BASIC OPERATION AND FEATURES
CONTROL FEATURES
This converter switches at a fixed frequency for predictable
EMI performance. Rectification of the transformer’s output is
accomplished with synchronous rectifiers. These devices, which
are MOSFETs with a very low on-state resistance, dissipate far
less energy than Schottky diodes. This is the primary reason
that the converter has such high efficiency, even at very low
output voltages and very high output currents.
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits
the user to control when the converter is on or off. This input
is referenced to the return terminal of the input bus, Vin(-).
The ON/OFF signal is active low (meaning that a low turns the
converter on). Figure A details four possible circuits for driving
the ON/OFF pin. Figure B is a detailed look of the internal ON/
OFF circuitry.
These converters are offered totally encased to withstand harsh
environments and thermally demanding applications. Dissipation
throughout the converter is so low that it does not require a
heatsink for operation in many applications; however, adding
a heatsink provides improved thermal derating performance in
extreme situations.
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’s output pins to the load.
Pin 7 should be connected to Vout(+) and Pin 5 should be
connected to Vout(-) at the point on the board where regulation
is desired. A remote connection at the load can adjust for a
voltage drop only as large as that specified in this datasheet,
that is
This series of converters uses the industry standard footprint
and pin-out configuration.
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
Sense Range % x Vout
ON/OFF
ON/OFF
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
Note: the output over-voltage protection circuit senses the
voltage across the output (pins 8 and 4) to determine when
it should trigger, not the voltage across the converter’s sense
leads (pins 7 and 5). Therefore, the resistive drop on the board
should be small enough so that output OVP does not trigger,
even during load transients.
Vin(_)
Vin(_)
Remote Enable Circuit
Negative Logic
(Permanently Enabled)
5V
ON/OFF
TTL/
CMOS
ON/OFF
Vin(_)
5V
10k
Vin(_)
Open Collector Enable Circuit
Direct Logic Drive
ON/OFF
50k
TTL
Figure A: Various circuits for driving the ON/OFF pin.
1000pF
Vin(_)
Figure B: Internal ON/OFF pin circuitry
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 11
Technical
Specification
PQ60150SMx03
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications.
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in the
application note titled “0” on our website. The lockout circuitry
is a comparator with dc hysteresis. When the input voltage is
rising, it must exceed the typical Turn-On Voltage Threshold
value (listed on the specifications page) before the converter
will turn on. Once the converter is on, the input voltage must fall
below the typical Turn-Off Voltage Threshold value before the
converter will turn off.
To decrease the output voltage, the user should connect a
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired
decrease of the nominal output voltage, the value of the resistor
should be
511
R
=
- 10.22 (kΩ)
trim-down
(∆%)
where
Vnominal – Vdesired
Vnominal
Output Current Limit: If the output current exceeds the
Output Current Limit threshold, the converter turns off. The
converter then enters a ‘hiccup mode’ where it repeatedly
turns on and off at a 5 Hz (nominal) frequency with a 5% duty
cycle until the short circuit condition is removed. This prevents
excessive heating of the converter or the load board.
=
x 100%
∆%
To increase the output voltage, the user should connect a
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired
increase of the nominal output voltage, the value of the resistor
should be
Output Over-Voltage Limit: If the voltage across the output
pins exceeds the Output Over-Voltage Protection threshold, the
converter will immediately stop switching. This prevents damage
to the load circuit due to 1) excessive series resistance in output
current path from converter output pins to sense point, 2) a
release of a short-circuit condition, or 3) a release of a current
limit condition. Load capacitance determines exactly how high
the output voltage will rise in response to these conditions. After
200 ms the converter will automatically restart.
5.11VOUT (100+∆%)
x
511
_
R
_
=
(kΩ)
trim-up
10.22
)
(
1.225∆%
∆%
where
V
= Nominal Output Voltage
out
Graphs on Page 3 show the relationship between the trim
resistor value and Rtrim-up and Rtrim-down, showing the total
range the output voltage can be trimmed up or down.
Over-Temperature Shutdown: A temperature sensor on
the converter senses the average temperature of the module.
The thermal shutdown circuit is designed to turn the converter
off when the temperature at the sensed location reaches the
Over-Temperature Shutdown value. It will allow the converter
to turn on again when the temperature of the sensed location
falls by the amount of the Over-Temperature Shutdown Restart
Hysteresis value.
Note: the TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
It is not necessary for the user to add capacitance at the Trim
pin. The node is internally bypassed to eliminate noise.
Total DC Variation of V
specifications, the maximum variation of the dc value of V
due to both trimming and remote load voltage drops, should not
: For the converter to meet its full
OUT
,
OUT
be greater than that specified for the output voltage trim range.
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 12
Technical
Specification
PQ60150SMx03
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because provides an understanding of why this instability arises, and
any dc-dc converter appears incrementally as a negative shows the preferred solution for correcting it.
resistance load. A detailed application note titled “Input
Application Circuits: Figure D provides a typical circuit
diagram which details the input filtering and voltage trimming.
System Instability” is available on the SynQor website which
Vout(+)
Vin(+)
Vsense(+)
Electrolytic
Capacitor
External
Input
Filter
Rtrim-up
Vin
Trim
or
ON/OFF
Vin(_)
Cload
Rtrim-down
Iload
Vsense(_)
Vout(_)
Figure D: Typical application circuit (negative logic unit, permanently enabled).
Input Filtering and External Capacitance: Figure E provides Startup Inhibit Period: The Startup Inhibit Period ensures that
a diagram showing the internal input filter components. This the converter will remain off for approximately 200 ms when it is
filter dramatically reduces input terminal ripple current, which shut down for any reason. When an output short is present, this
otherwise could exceed the rating of an external electrolytic generates a 5 Hz “hiccup mode,” which prevents the converter
input capacitor. The recommended external input capacitance from overheating. In all, there are six ways that the converter
is specified in the Input Characteristics section on the Electrical can be shut down, initiating a Startup Inhibit Period:
Characteristics page. More detailed information is available in
• Input Under-Voltage Lockout
• Output Over-Voltage Protection
• Over Temperature Shutdown
• Current Limit
the application note titled “EMI Characteristics” on the SynQor
website.
L
Vin(+)
• Short Circuit Protection
• Turned off by the ON/OFF input
C
Vin(_)
Figure E: Internal Input Filter Diagram (component values
listed on the specifications page).
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 13
Technical
Specification
PQ60150SMx03
Figure F shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
Before time t0, when the input voltage is below the UVLO
threshold, the unit is disabled by the Input Under-Voltage Lockout
feature. When the input voltage rises above the UVLO threshold,
the Input Under-Voltage Lockout is released, and a Startup Inhibit
Period is initiated. At the end of this delay, the ON/OFF pin is
evaluated, and since it is active, the unit turns on.
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
Vin
Under-Voltage
Lockout
Turn-On
Threshold
ON/OFF
(neg logic)
ON
OFF
ON
OFF
ON
35ms(typical
turn on time)
Vout
2ms
(typical power-up
inhibit period)
200ms
200ms
t
t0
t1
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 14
Technical
Specification
PQ60150SMx03
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s dc-dc converters
follows the format shown in the example below.
The tables below show the valid model numbers and ordering
options for converters in this product family. When ordering
SynQor converters, please ensure that you use the complete
15 character part number consisting of the 12 character
base part number and the additional characters for options.
Add “-G” to the model number for 6/6 RoHS compliance.
PQ 60 150 S M L 03 N R S - G
6/6 RoHS
Options (see
Input
Output
Voltage
Max Output
Current
Ordering Information)
Model Number
Voltage
Output Current
PQ60150SMw03xyS
35-75V
15V
3.0A
Thermal Design
Performance Level
Package Size
The following options must be included in place of the w x y z
spaces in the model numbers listed above.
Output Voltage
Options Description: w x y z
Input Voltage
Thermal Design
A - Open Frame
L - Low Profile
C - Encased with
Threaded Baseplate
Enable Logic Pin Style
Feature Set
S - Standard
Product Family
K - 0.110"
P - Positive N - 0.145"
N - Negative R - 0.180"
Y - 0.250”
The first 12 characters comprise the base part number and
the last 3 characters indicate available options. The “-G”
suffix indicates 6/6 RoHS compliance.
Not all combinations make valid part numbers, please contact
SynQor for availability. See the Product Summary web page for
more options.
Application Notes
PATENTS
A variety of application notes and technical white papers can
be downloaded in pdf format from our website.
SynQor holds the following patents, one or more of which
might apply to this product:
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium,
Hexavalent Chromium, Mercury, Polybrominated Biphenyls
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical
and Electronic Equipment. This SynQor product is 6/6 RoHS
compliant. For more information please refer to SynQor’s
RoHS addendum available at our RoHS Compliance / Lead Free
5,999,417
6,594,159
6,927,987
7,119,524
6,222,742
6,731,520
7,050,309
7,269,034
6,545,890
6,894,468
7,072,190
7,272,021
6,577,109
6,896,526
7,085,146
7,272,023
Initiative web page or e-mail us at rohs@synqor.com
.
Warranty
Contact SynQor for further information:
SynQor offers a two (2) year limited warranty. Complete
warranty information is listed on our website or is available
upon request from SynQor.
Phone:
Toll Free: 888-567-9596
978-849-0600
Fax:
E-mail:
Web:
978-849-0602
power@synqor.com
www.synqor.com
Information furnished by SynQor is believed to be accurate and
reliable. However, no responsibility is assumed by SynQor for
its use, nor for any infringements of patents or other rights of
third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of
SynQor.
Address: 155 Swanson Road
Boxborough, MA 01719
USA
Product # PQ60150SMx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005168 Rev. C
06/28/11
Page 15
PQ60150SMw03xyS 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
PQ60150SMX03 | SYNQOR | Output current limit and short circuit protection | 获取价格 | |
PQ60180HTA09 | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NKF | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NKS | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NNF | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NNS | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NRF | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NRS | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NYF | SYNQOR | Half-brick DC/DC Converter | 获取价格 | |
PQ60180HTA09NYS | SYNQOR | Half-brick DC/DC Converter | 获取价格 |
PQ60150SMw03xyS 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6