Technical  
Specification  
NQ60x60QGC20  
9-60 V  
Continuous Input  
0-60 V  
Outputs  
20 A  
Current  
Non-  
Isolated  
Quarter-brick  
DC-DC Converter  
®
TheꢀNiQor ꢀquarter-brickꢀdc-dcꢀconverterꢀisꢀaꢀnon-isolatedꢀ  
buck-boost  
             
regulator,  
                     
which  
                         
employs  
                               
synchronousrectificationꢀ  
                                        
toachieveextremelyhighconversionefficiency.TheHighꢀ  
InputꢀVoltageꢀNiQorꢀBrickꢀfamilyꢀofꢀconvertersꢀcanꢀbeꢀusedꢀ  
intraditionalDPA(distributedpowerarchitecture)systemsꢀ  
orꢀprovideꢀaꢀregulatedꢀoutputꢀvoltageꢀfromꢀaꢀbatteryꢀsourceꢀ  
orꢀ otherꢀ variableꢀ voltageꢀ source.ꢀ Theꢀ NiQorꢀ Brickꢀ familyꢀ  
canꢀ beꢀ configuredꢀ toꢀ Buckꢀ theꢀ inputꢀ voltageꢀ downꢀ toꢀ aꢀ  
lowerꢀ voltageꢀ orꢀ Boostꢀ theꢀ inputꢀ voltageꢀ upꢀ toꢀ aꢀ higherꢀ  
voltageꢀusingꢀaꢀsingleꢀexternalꢀresistor.ꢀTheseꢀmodulesꢀareꢀ  
RoHSꢀ6/6ꢀcompliantꢀ(seeꢀlastꢀpage).ꢀ  
Non-Isolated  
Operational Features  
Ultraꢀhighꢀefficiency,ꢀupꢀtoꢀ95%ꢀatꢀfullꢀratedꢀload  
Deliversꢀupꢀtoꢀ20ꢀAꢀofꢀoutputꢀcurrent  
InputꢀVoltageꢀRange:ꢀ9ꢀ-ꢀ60ꢀV  
NiQor quarter-brick module  
Outputꢀvoltageꢀrange:ꢀ0ꢀ-ꢀ60ꢀVꢀ(negativeꢀoutputꢀisꢀpossible)  
Extensiveꢀon-boardꢀinputꢀandꢀoutputꢀfiltering  
Noꢀminimumꢀloadꢀrequirementꢀmeansꢀnoꢀpreloadꢀ  
resistorsꢀrequired  
Buckꢀorꢀbuck-boostꢀmodeꢀavailable  
Adjustableꢀcurrentꢀlimitꢀwithꢀcurrentꢀmonitorꢀ(Cꢀoption)  
Protection Features  
Inputꢀunder-voltageꢀlockoutꢀprotectsꢀtheꢀconverterꢀatꢀlowꢀ  
inputꢀvoltageꢀconditions  
Over-currentꢀshutdownꢀprotectsꢀconverterꢀfromꢀexcessiveꢀ  
Mechanical Features  
loadꢀcurrentꢀorꢀshortꢀcircuits  
Outputꢀover-voltageꢀprotectionꢀprotectsꢀloadꢀfromꢀ  
damagingꢀvoltages  
Industryꢀstandardꢀquarter-brickꢀpin-outꢀconfiguration  
Size:ꢀ1.54"ꢀxꢀ2.39"ꢀ(39x60.6ꢀmm)  
Totalꢀheightꢀonlyꢀ0.515"ꢀ(13.08ꢀmm)  
Totalꢀweight:ꢀ3ꢀozꢀ(85ꢀg)  
Thermalꢀshutdownꢀprotectsꢀconverterꢀfromꢀabnormalꢀ  
environmentalꢀconditions  
Safety Features  
Control Features  
UL/cULꢀ60950-1ꢀrecognizedꢀ(USꢀ&ꢀCanada)  
TUVꢀcertifiedꢀtoꢀEN60950-1  
On/Offꢀcontrol  
BoardꢀandꢀplasticꢀcomponentsꢀmeetꢀUL94V-0ꢀ  
Outputꢀvoltageꢀtrimꢀpermitsꢀcustomꢀvoltagesꢀ  
RemoteꢀSenseꢀ(Sꢀoption,ꢀstandard)  
Currentꢀlimitꢀtrimꢀ(Cꢀoption)  
flammabilityꢀrequirements  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 1  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
MECHANICALꢀDIAGRAM  
1.536 ±.020  
[ 39,01±0,5]  
.810[ 20,57 ]  
.600[ 15,24 ]  
.450[ 11,43 ]  
.300[ 7,62 ]  
.150[ 3,81 ]  
.263±.020  
[ 6,7±0,5 ]  
.515±.025  
[13.08± 0.63]  
OVERALL HEIGHT  
8
7 6 5 4  
2.386±.020  
[ 60,6±0,5]  
Top View  
Side View  
1.86  
[ 47,2 ]  
2.00  
[ 50,8]  
M3 THREADED INSERTS  
2 PLACES  
SEE NOTES 1 & 2  
.145  
[ 3,68 ]  
1
2
3
.020±.010  
.468±.020[ 11,89±0,5 ]  
.300[ 7,62 ]  
[ 0,51±0,25]  
BOTTOMSIDE  
CLEARANCE  
.183±.020  
[ 4,65±0,5]  
.600[ 15,24 ]  
PIN DESIGNATIONS  
NOTES  
Pin Label Function  
1)  
M3 SCREWS USED TO BOLT UNIT'S BASEPLATE TO OTHER SURFACES  
SUCH AS HEATSINKS MUST NOT EXCEED 0.090" (2.28mm) DEPTH  
BELOW THE SURFACE OF THE BASEPLATE.  
1
Vin(+)  
Positive input  
TTL input to turn converter on and off,  
referenced to Vin(-), with internal pull up  
2
ON/OFF  
2)  
3)  
APPLIED TORQUE PER SCREW SHOULD NOT EXCEED 6in-lb (0.7Nm)  
Negative input voltage, internal short to  
Pin 4  
Negative output voltage, internal short to  
Pin 3  
Negative remote sense. See note 1  
(S option)  
Isense (C option)  
Output voltage trim  
Positive remote sense. See note  
(S option)  
Isense (C option)  
Positive output voltage  
Vin  
(-)  
BASEPLATE FLATNESS TOLERANCE IS 0.004" (.10mm) TIR FOR  
SURFACE  
3
4
4)  
5)  
6)  
7)  
8)  
PINS 1-3, 5-7 ARE 0.040" (1.02mm) DIA. WITH 0.080" (2.03mm) DIA.  
STANDOFF SHOULDERS  
Vout  
(-)  
PINS 4 AND 8 ARE 0.062" (1.57mm) DIA. WITH 0.100" (2.54mm)  
DIA. STANDOFF SHOULDERS  
SENSE  
(-)  
5
6
7
8
ALL PINS: MATERIAL: COPPER ALLOY  
FINISH: MATTE TIN OVER NICKEL PLATE  
TRIM  
UNDIMENSIONED COMPONENTS ARE SHOWN FOR VISUAL  
REFERENCE ONLY  
SENSE  
(+)  
ALL DIMENSIONS IN INCHES(mm)  
TOLERANCES: X.XXIN +/-0.02 (X.Xmm +/-0.5mm) X.XXXIN +/-  
0.010 (X.XXmm +/-0.25mm)  
Vout(+)  
Notes:  
9)  
Weight: =3oz (85g) typical  
1)SENSE(–) should be connected to Vout(–) either remotely or at  
the converter  
10)  
Workmanship: Meets or exceeds IPC-A-610C Class II  
2)SENSE(+) should be connected to Vout(+) either remotely or at  
the converter.  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 2  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
NQ60x60QGC20 ELECTRICAL CHARACTERISTICS  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24 V dc unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications  
subject to change without notice.  
Parameter  
Vout Min. Typ. Max. Units Notes & Conditions  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Non-Operating  
Operating  
Storage Temperature  
All  
All  
All  
All  
0
80  
60  
125  
5.5  
V
V
°C  
V
Continuous  
Continuous  
-55  
0
Voltage at ON/OFF input pin  
RECOMMENDED OPERATING CONDITIONS  
Input Voltage Range  
All  
All  
9
60  
25  
20  
V
A
A
µF  
V
A
Turn on at 10V  
Input Fuse Rating  
Fast blow external fuse recommended  
Input current max equals output rated current  
ESR < 1.5 Ω  
Input Current  
External Input Capacitance  
Output Voltage  
All  
All  
All  
100  
0
0
60  
20  
Output Current  
Output voltage dependent  
INPUT CHARACTERISTICS  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Hysteresis  
Input Current Limit  
No-Load Input Current  
All  
All  
All  
All  
12  
24  
48  
All  
All  
9.2  
8.1  
9.5  
8.5  
1.0  
24  
93  
85  
235  
35  
10  
8.9  
V
V
V
A
mA  
mA  
mA  
mA  
µF\µH\µF  
Disabled Input Current  
Input Filter Components Value (C\L\C)  
OUTPUT CHARACTERISTICS  
Output Voltage Range  
Operating Output Current Range  
Output Voltage Regulation  
Total Output Voltage Range  
Output Voltage Ripple and Noise (pk-pk/36Vin)  
8.8\2.2\26.4  
All  
All  
0
0
60  
20  
V
A
Set output by Rtrim resistor  
All  
12  
24  
48  
All  
All  
±480 mV ±4%*Vout  
Sense pin, over sample, line, load, temp. & life  
36 Vin Full Load; 100uF; 20 MHz b.w.  
15  
15  
40  
24  
mV  
mV  
mV  
A
"
Output DC Over Current limit  
External Output Capacitance  
C Option: Isense voltage  
No load  
Effective on input, output condition  
ESR > 1 mΩ  
0
1000  
µF  
All  
All  
All  
1.25  
1.83  
10  
V
V
kΩ  
Full load  
20 A load  
Output resistance of Isense  
C Option: Itrim voltage  
Voltage at no load  
All  
All  
All  
All  
All  
0.12  
2.12  
10.2  
2.5  
V
V
kΩ  
V
Voltage at maximum load  
Pull-Up Resistance of Itrim Pin  
Pull-Up Voltage  
20 A load  
C Option: Reverse Current  
TEMP LIMITS FOR POWER DERATING  
Semiconductor Junction Temperature  
Board Temperature  
Baseplate Temperature  
EFFICIENCY  
2
µA  
Enabled or Disabled  
All  
All  
All  
125  
125  
100  
°C  
°C  
°C  
Package rated to 150 °C  
ULrated max operating temp 130 °C  
100% Load; 24 Vin  
“ ; 48 Vin  
“ ; 24 Vin  
50% Load; 24 Vin  
12  
24  
48  
12  
24  
48  
92  
95  
94  
94  
95  
95  
%
%
%
%
%
%
W mode only  
W mode only  
“ ; 48 Vin  
“ ; 24 Vin  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 3  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
NQ60x60QGC20 ELECTRICAL CHARACTERISTICS (Continued)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24 V dc unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications  
subject to change without notice.  
Parameter  
Vout Min. Typ. Max. Units Notes & Conditions  
DYNAMIC CHARACTERISTICS  
Output Voltage during Current Transient  
For a Step Change in Output Current  
Settling Time  
All  
1
V
(0.1 A/µs); 50%-75%-50% Iout max  
To within 1.5% Vout nom.  
All  
5
ms  
Turn on Transient  
Startup delay  
Rise Rate  
Output Voltage Overshoot  
FEATURE CHARACTERISTICS  
Switching Frequency  
All  
All  
All  
2
0.6  
ms  
V/ms  
V
Resistive load  
"
"
0
All  
240  
250  
260  
kHz  
ON/OFF Control  
Negative Logic (N) ON/OFF Control  
Off-State Voltage  
On-State Voltage  
Pull-Up Voltage  
Pull-Up Resistance  
Output Voltage Trim Range  
Input/Output Over-Voltage Protection  
Over-Temperature Shutdown  
Over-Temperature Shutdown Restart Hysteresis  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (TR-NWT-000332; Telcordia)  
Calculated MTBF (MIL-HDBK-217F; MIL-217)  
Field Demonstrated MTBF  
All  
All  
All  
All  
All  
All  
All  
All  
1.8  
0
3.3  
0.8  
V
V
V
kΩ  
V
V
3.3  
10  
0
66  
60  
75  
Measured Vout+ to common pins  
Over full temp range  
Average PCB Temperature  
72  
115  
15  
°C  
°C  
6
6
6
All  
All  
All  
TBD  
TBD  
10 Hrs. 100% load, 200LFM, 40 °C Ta  
10 Hrs. 100% load, 200LFM, 40 °C Ta  
10 Hrs. See our website for details  
STANDARDS COMPLIANCE  
Parameter  
STANDARDS COMPLIANCE  
Notes & Conditions  
UL/cUL 60950-1  
Pending UL Approval File # E194341  
EN60950-1  
Certified by TUV  
Needle Flame Test (IEC 695-2-2)  
IEC 61000-4-2  
GR-1089-CORE  
Test on entire assembly; board & plastic components UL94V-0 compliant  
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)  
Section 7 - electrical safety, Section 9 - bonding/grounding  
Telcordia (Bellcore) GR-513  
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new  
releases or download from the SynQor website.  
QUALIFICATION TESTING  
Parameter  
QUALIFICATION TESTING  
Life Test  
# Units Test Conditions  
32  
95% rated Vin and load, units at derating point, 1000 hours  
Vibration  
5
5
10  
5
5
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x and y axis, 1 drop in z axis  
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load  
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day  
MIL-STD-883, method 2003  
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
Solderability  
15 pins  
Note: Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply  
robust, reliable product. Contact the factory for official product family qualification documents.  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 4  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
30  
25  
20  
15  
10  
5
48Vin 24Vout  
24Vin 12Vout  
48Vin 12Vout  
24Vin48Vout  
12Vin 24Vout  
12Vin 48Vout  
48Vin 24Vout  
24Vin 12Vout  
48Vin 12Vout  
24Vin 48Vout  
12Vin 24Vout  
12Vin 48Vout  
0
0
5
10  
15  
20  
0
5
10  
15  
20  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at different output voltage vs. load current for dif-  
Figure 2: Power dissipation at different output voltage vs. load current  
ferent input voltage at 25 °C  
.
for different input voltage at 25 °C.  
21  
18  
15  
12  
9
See Fig. 5  
1ꢀµH  
source  
impedance  
See Fig. 6  
iC  
iS  
Dc-dc  
Converter  
Vin  
Vout  
Tb=80 C; Vout=12 V  
Tb=100 C; Vout=12 V  
Tb=80 C; Vout=24 V  
Tb=100 C; Vout=24 V  
Tb=80 C; Vout=48 V  
Tb=100 C; Vout=48 V  
6
VSOURCE  
100ꢀµFꢀ  
C*  
100mWꢀESRꢀ  
3
tantalum  
capacitor  
0
*ꢀSeeꢀvaluesꢀforꢀrecommendedꢀexternalꢀinputꢀcapacitance.ꢀ  
Inductorꢀoptionalꢀasꢀneeded.  
0
10  
20  
30  
40  
50  
60  
Input Voltage (V)  
Figure 3: Maximum output power derating curve with a controlled  
baseplate temperature of 80ºC and 100ºC.  
Figure 4: Test set-up diagram showing measurement points for Input  
Terminal Ripple Current (Figure 5), and Output Voltage Ripple  
(Figure 6).  
60 Vout  
60 Vout  
48 Vout  
48 Vout  
24 Vout  
12 Vout  
24 Vout  
12 Vout  
Figure 5: Input Terminal Ripple Current at 36 V input and rated  
Figure 6: Output Voltage Ripple at 36 V input and rated load current  
load current (500 mA/div). Load capacitance: 100  
Bandwidth: 20 MHz. See Figure 4.  
µF electrolytic cap.  
(50 mV/div). Load capacitance: 100  
MHz. See Figure 4.  
µF electrolytic cap.. Bandwidth: 20  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 5  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
60 Vout  
48 Vout  
60 Vout  
48 Vout  
24 Vout  
12 Vout  
24 Vout  
12 Vout  
on/off  
on/off  
Figure 7: Turn-on transient at 36 V input; full load (20 ms/div).  
Ch 1: ON/OFF input (5 V/div)  
Figure 8: Turn-on transient at 36 V input; zero load (20 ms/div).  
Ch 1: ON/OFF input (5 V/div)  
Ch 2-4: Vout (10 V/div)  
Ch 2-4: Vout (10 V/div)  
2.00  
1.50  
1.00  
0.50  
0.00  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
0
5
10  
15  
20  
0
5
10  
15  
20  
25  
Load (A)  
Current Limit (A)  
Figure 9: Im o n pin voltage vs. load current at 24 V input and 13.8 V  
output. Load capacitance: 100 F electrolytic cap. C option only.  
Figure 10: Current limit vs. Itrim pin voltage at 24 V input and 13.8 V  
µ
output. Load capacitance: 100  
C option only.  
µF electrolytic cap.  
60 Vout  
48 Vout  
24 Vout  
12 Vout  
Figure 11: Output voltage response for 36 V input; 12 V, 24 V, 36 V output  
to step-change in load current (50-75-50% of Iout max; di/dt=0.1A/  
µ
s). Load  
cap: 100 F, 100 m ESR tant, Ch 1-3: Vout (2 V/div);(5 ms/div).  
µ
W
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 6  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
Alternatively, the TRIM pin can be driven from an external  
voltage source:  
BASIC OPERATION AND FEATURES  
These converters use a digital controller for the buck stage and  
boost stage (see Figure A). It automatically changes operating  
mode (buck mode or boost) when the line voltage or output set  
point changes. Both stages are accomplished with synchronous  
rectifiers. Very high efficiency is maintained over wide input  
and output ranges by shifting operational modes and use of  
synchronous rectifiers.  
Vout  
V(pin6) = 2.366 –  
2.316  
2.314  
Vmax  
( )  
where:  
V
out = desired output voltage  
Vin+  
Vout+  
Vmax = maximum rated output voltage  
Loutput  
Cout1  
GATE_Q3  
L
Linput  
GATE_Q1  
JUMPER  
Q3  
Q4  
Q1  
Q2  
To maintain the accuracy of the output voltage over load current,  
it is vital that any trim-up resistor be terminated directly to the  
converter’s Sense(-) pin (S option) or Vout(-) pin (C option), not  
at the connection to the load. A separate Kelvin connection to the  
PCB pad for the Vout(-) is optimal.  
Cout2  
Cin1  
Cin2  
GATE_Q4  
GATE_Q2  
Vin-  
Vout-  
Figure A: Topology  
PROTECTION FEATURES  
W mode: Q3, Q4 are populated, Jumper is open.  
T mode: Q3, Q4 are open, Jumper is populated.  
Input Under-Voltage Lockout: The converter is designed  
to turn off when the input voltage is too low, helping avoid an  
input system instability problem, described in more detail in the  
application note titled “Input System Instability”. The lockout  
circuitry is a comparator with DC hysteresis. When the input  
voltage is rising, it must exceed the typical Turn-On Voltage  
Threshold value (listed on the specification page) before the  
converter will turn on. Once the converter is on, the input  
voltage must fall below the typical Turn-Off Voltage Threshold  
value before the converter will turn off.  
The converter runs at a fixed frequency with a predictable  
EMI performance.  
This series of quarter-brick and eighth-brick converters use the  
industry standard footprint and pin-out configuration.  
CONTROL FEATURES  
REMOTE ON/OFF: The ON/OFF input permits the user to con-  
trol when the converter is on or off. Only Negative ON/OFF logic  
is available in this power module series.  
Output Current Shutdown: To provide protection in an  
output short condition, the unit is equipped with internal short  
circuit protection. When the short protection is triggered, the  
unit shutdowns first. After approximately 16 ms inhibit time, the  
units turn on again. If the short condition remains, the current  
limit circuit will limit the output current. The units operate  
normally once the fault condition is removed.  
Negative logic ON/OFF signal turns the module OFF during logic  
high (leave the pin floating or set voltage between 1.8~3.3 V) and  
turns the module ON during logic low [tie to Vin(-)].  
Internal Over-Voltage Protection: To fully protect from  
excessive output voltage, the output over-voltage shutdown  
circuitry is contained. This OVP is independent of the trimmed set  
point. The shutdown point is fixed on the standard option.  
OUTPUT VOLTAGE TRIM: The output voltage can be  
programmed to any voltage between 0 V dc and Vmax by  
connecting one resistor between the Pin 6 (TRIM) pin and Pin 5  
[Sense(-)]. For a desired output voltage, the value of the resistor  
should be:  
Over-Temperature Shutdown: A temperature sensor on  
the converter senses the average temperature of the module.  
The thermal shutdown circuit is designed to turn the converter  
off when the temperature at the sensed location reaches the  
Over-Temperature Shutdown value. It will allow the converter  
to turn on again when the temperature of the sensed location  
falls by the amount of the Over-Temperature Shutdown Restart  
Hysteresis value.  
11830 x V  
11736  
max  
_
R
trim-up(Vout) =  
()  
10912  
+
.0536  
.058 x V  
V
[( ) ]  
out  
max  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 7  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
APPLICATION CONSIDERATIONS  
Vin-/  
Vout+  
Vin+  
Cin1  
Cin2  
Limited output voltage resolution: The internal voltage  
control feedback loop has limited resolution. Therefore, the  
output voltage will exhibit discrete steps as the loop responds  
to changes in line, load, trim, or remote sense. For instance,  
on close examination, the startup ramp has a “stair-step”  
shape. Likewise, a load transient response will be composed  
of multiple discrete steps.  
1
2
8
7
6
5
Vout+  
SENSE+  
TRIM  
Vin+  
Cout1  
ENABLE  
Dc/dc  
converter  
SENSE-  
Rtrim-up  
3
4
Vin-  
Vout-  
Vout-  
Input filtering: These modules should be connected to a  
low-impedance source. A highly inductive source can affect the  
stability of the module. An input capacitance must be placed  
directly adjacent to the input pin of the module, to minimize  
input ripple voltage and ensure module stability.  
Figure B: Negative output setup  
Using this negative output setup impacts the available output  
voltage range and current limit.  
The output voltage range becomes 0 to Vmax - Vin, and the cur-  
Output capacitance: For stable operation of the module, there  
is no extra external capacitor required. To reduce the output  
ripple and improve dynamic response to a step load change,  
additional capacitance at the output can be used. Low ESR  
polymer and ceramic capacitors are recommended to improve  
the dynamic response of the module. In many applications,  
however, additional external output capacitance is a requirement  
which will cause the startup time to change.  
rent limit is scaled by:  
Vin  
(Vin + Vout)  
Current monitor/trimmable current limit (C option): In  
addition to voltage trim, the C option offers an adjustable current  
limit input and a current monitor output. The C option also  
includes an ideal diode circuit in series with the Vout+ pin that  
prevents reverse current flow. This enables applications such as  
battery charging, current sharing, and current read back.  
Remote sense (S option): Vout remote sensing is provided  
to achieve proper regulation at the load points and reduce  
effects of distribution losses on output line. In the event of an  
open remote sense line, the module shall maintain local sense  
regulation through an internal resistor. The module shall correct  
for a total of 10% Vout.  
Dc/dc  
converter  
Vout+  
Vin+  
Cin  
1
2
8
7
6
5
Vout+  
Vin+  
IMON  
VTRIM  
IMON  
Cout  
ENABLE  
Current limit: Available power is limited by output current  
in buck mode (Vin>Vout), but by input current in boost mode  
(Vin<Vout).  
ITRIM  
3
4
Vin-  
Vout-  
RadjIlim Rtrim-up  
Vout-  
Vin-  
for Vin >Vout,  
Figure C: Current monitor/trimmable current limit setup  
Ilimit = 1.2 x Imax  
The Rtrim-up resistor increases the output voltage, identical in  
function to the S option.  
for Vin < Vout,  
Vin  
The RadjItrim resistor reduces the output current limit, according  
to the following equation:  
Ilimit = 1.2 x Imax  
Vout  
( )  
0.0469 Imax + Itrim  
where Imax = Maximum rated output current  
RadjItrim  
=
10200 - 10  
(Ω)  
1.153 I  
+ Itrim  
[(  
max  
) ]  
Negative output: This series of converters can be set to  
negative output (see Figure B).  
Alternatively, the Itrim pin can be driven from an external voltage  
source:  
V(pin5) = 2.085(Itrim/Imax) + 0.0953  
where Itrim is the desired current limit setpoint  
If Ilimit is less than Itrim, then Ilimit takes precedence.  
The I  
pin voltage tracks the output current, as shown in  
mon  
figure 10. This pin has a 10kOhm output impedance.  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 8  
9 - 60 V  
0 - 60 V  
20 A  
Input:  
Outputs:  
Current:  
Package:  
Quarter-brick  
Technical Specification  
PART NUMBERING SYSTEM  
ORDERING INFORMATION  
The part numbering system for SynQor’s dc-dc converters  
follows the format shown in the example below.  
The tables below show the valid model numbers and ordering  
options for converters in this product family. When ordering  
SynQor converters, please ensure that you use the complete  
15 character part number consisting of the 12 character base  
part number and the additional 3 characters for options.  
Add “-G” to the model number for 6/6 RoHS compliance.  
NQ 60 W 60 Q  
G
C 20 N N S - G  
6/6ꢀRoHS  
Options(seeꢀ  
OrderingꢀInformation)  
Input  
Voltage  
Output  
Voltage  
Max Output  
Current  
Model Number  
OutputꢀCurrent  
ThermalꢀDesign  
PerformanceꢀLevel  
PackageꢀSize  
NQ60w60QGC20xyz-G  
9 - 60 V  
0 - 60 V  
20 A  
OutputꢀVoltage  
Modeꢀ(seeꢀOrderingꢀInformation)  
InputꢀVoltage  
ProductꢀFamily  
Thefollowingoptionsmustbeincludedinplaceofthe x y z  
spacesꢀinꢀtheꢀmodelꢀnumbersꢀlistedꢀabove.  
Mode: w  
Options Description: x y z  
The first 12 characters comprise the base part number and  
the last 3 characters indicate available options. The “-G”  
suffix indicates 6/6 RoHS compliance.  
Enable Logic  
Pin Style  
Feature Set  
S - Standard  
C - Current  
monitor output  
/ Trimmable  
current limit  
T - Buck  
W - Buck /  
Boost  
K - 0.110"  
N - 0.145"  
R - 0.180"  
Y - 0.250"  
N - Negative  
Application Notes  
Contact SynQor for C - Feature Set availability.  
A variety of application notes and technical white papers can  
be downloaded in pdf format from our website.  
Not all combinations make valid part numbers, please contact  
SynQor for availability. See the Product Summary web page for  
more options.  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium, Hexavalent  
Chromium, Mercury, Polybrominated Biphenyls (PBB), and  
Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic  
Equipment. This SynQor product is 6/6 RoHS compliant. For  
more information please refer to SynQor’s RoHS addendum  
available at our RoHS Compliance / Lead Free Initiative web  
PATENTS  
SynQorꢀholdsꢀtheꢀfollowingꢀpatents,ꢀoneꢀorꢀmoreꢀofꢀwhichꢀ  
mightꢀapplyꢀtoꢀthisꢀproduct:  
page or e-mail us at rohs@synqor.com  
.
5,999,417ꢀ  
6,594,159ꢀ  
6,927,987ꢀ  
7,119,524ꢀ  
6,222,742ꢀ  
6,731,520ꢀ  
7,050,309ꢀ  
7,269,034ꢀ  
6,545,890ꢀ  
6,894,468ꢀ  
7,072,190ꢀ  
7,272,021ꢀ  
6,577,109ꢀ  
6,896,526ꢀ  
7,085,146ꢀ  
7,272,023  
Contact SynQor for further information:  
Phone:  
Toll Free: 888-567-9596  
Fax:  
978-849-0600  
Warranty  
SynQor offers a three (3) year limited warranty. Complete warranty informa-  
tion is listed on our website or is available upon request from SynQor.  
978-849-0602  
E-mail:  
Web:  
power@synqor.com  
www.synqor.com  
Information furnished by SynQor is believed to be accurate and reliable.  
However, no responsibility is assumed by SynQor for its use, nor for any  
infringements of patents or other rights of third parties which may result  
from its use. No license is granted by implication or otherwise under any  
patent or patent rights of SynQor.  
Address: 155 Swanson Road  
Boxborough, MA 01719  
USA  
Product # NQ60x60QGC20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. B  
03/16/09  
Page 9  

相关型号:

NQ60W60QGC20NNC-G

Quarter-brick DC-DC Converter
SYNQOR

NQ60W60QGC20NNS-G

Quarter-brick DC-DC Converter
SYNQOR

NQ60W60QGC20NRC-G

Quarter-brick DC-DC Converter
SYNQOR

NQ60W60QGC20NRS-G

Quarter-brick DC-DC Converter
SYNQOR

NQ60W60QGC20NYC-G

Quarter-brick DC-DC Converter
SYNQOR

NQ60W60QGC20NYS-G

Quarter-brick DC-DC Converter
SYNQOR

NQ60W60QGV20NKC-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-8
SYNQOR

NQ60W60QTV25NRC

Power Supply Module,
SYNQOR

NQ60W60QTV25NRS

Power Supply Module,
SYNQOR

NQ60X60EGC05

Eighth-brick DC-DC Converter
SYNQOR

NQ60X60ETC10

Eighth-brick DC-DC Converter
SYNQOR

NQ60X60QGC20

Quarter-brick DC-DC Converter
SYNQOR