Technical  
Specification  
NQ60x60QGx20  
9-60V  
Continuous Input  
0-60V  
Outputs  
20A  
Current  
Non-  
Isolated  
Quarter-brick  
DC-DC Converter  
The NiQor Quarter-brick dc-dc converter is a non-isolated  
buck-boost regulator, which employs synchronous  
rectification to achieve extremely high conversion efficiency.  
The High Input Voltage NiQor Brick family of converters can  
be used in traditional DPA (distributed power architecture)  
systems or provide a regulated output voltage from a  
battery source or other variable voltage source. The NiQor  
Quarter-brick family can be configured to Buck the input  
voltage down to a lower voltage or Boost the input voltage  
up to a higher voltage using a single external resistor.  
These modules are RoHS 6/6 compliant (see page 12).  
Non-Isolated  
G
-
S
-
0
A
2
0
C
0
2
G
6
@
T
U
Q
0
6
VO  
W
VI  
0
6
-
Q
9
0
N
N
0
6
-
NiQor Quarter-brick module  
Protection Features  
Operational Features  
• High efficiency, 95% at full rated load current  
• Delivers up to 20A of output current  
• Input Voltage Range: 9-60V  
• Input under-voltage lockout protects the converter at low input  
• Output Voltage Range: 0-60V (negative output is possible)  
• Extensive on-board input and output filtering  
• No minimum load requirement means no preload resistors required  
• Buck or buck-boost versions available  
voltage conditions  
• Over-current shutdown protects converter from excessive  
load current or short circuits  
• Input/output over-voltage protection protects load and regulator  
from damaging voltages  
• Thermal shutdown protects converter from abnormal  
• Adjustable current limit with current monitor (C option)  
environmental conditions  
Mechanical Features  
• Industry standard quarter-brick pin-out configuration  
Safety Features  
• Standard size: Encased - 1.54" x 2.39" (39x60.6 mm)  
Flanged - 2.20" x 2.39" (55.88x60.6 mm)  
UL 60950-1:2007  
EN60950-1/A12:2011  
Total height only 0.515" (13.08 mm)  
CAN/CSA-C22.2 No. 60950-1:2007  
Total weight: Encased - 3oz (85g)  
Flanged - 3.17oz (90g)  
Contents  
Control Features  
Page No.  
Open Frame Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Baseplated Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Technical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Standards & Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Technical Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
• On/Off control  
• Output voltage trim permits custom voltages  
• Remote Sense (S option, standard)  
• Current limit trim (C option)  
• Output voltage trim range from 0 - 60V  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 1  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Standard Mechanical Diagram  
1.536 ±.020  
[
±0,5]  
39,01  
.810[ 20,57 ]  
.600[ 15,24 ]  
.450[ 11,43 ]  
.300[ 7,62 ]  
.150[ 3,81 ]  
.263±.020  
[ 6,7±0,5 ]  
.515±.025  
[13.08± 0.63]  
OVERALL HEIGHT  
8
7 6 5 4  
2.386±.020  
[ 60,6±0,5]  
Top View  
Side View  
1.86  
[ 47,2 ]  
2.00  
[ 50,8]  
M3 THREADED INSERTS  
2 PLACES  
SEE NOTES 1 & 2  
.145  
[ 3,68 ]  
1
2
3
.020±.010  
.468±.020[ 11,89±0,5 ]  
.300[ 7,62 ]  
[ 0,51±0,25]  
BOTTOMSIDE  
CLEARANCE  
.183±.020  
[ 4,65±0,5]  
.600[ 15,24 ]  
NOTES  
PINꢀDESIGNATIONS  
1)  
M3 SCREWS USED TO BOLT UNIT'S BASEPLATE TO OTHER SURFACES  
SUCH AS HEATSINKS MUST NOT EXCEED 0.090" (2.28mm) DEPTH  
BELOW THE SURFACE OF THE BASEPLATE.  
Pin Label  
Function  
1
2
Vin(+)  
Positive input  
2)  
APPLIED TORQUE PER SCREW SHOULD NOT EXCEED 6in-lb (0.7Nm)  
TTL input to turn converter on and off, referenced  
to Vin(-), with internal pull up  
ON/OFF  
3)  
BASEPLATE FLATNESS TOLERANCE IS 0.004" (.10mm)  
TIR FOR SURFACE  
3
4
Vin(-)  
Negative input voltage, internal short to Pin 4  
Negative output voltage, internal short to Pin 3  
Negative remote sense. See note 1 (S option)  
Itrim (C option)  
Output voltage trim  
Positive remote sense. See note 2 (S option)  
Imon (C option)  
4)  
5)  
6)  
7)  
8)  
PINS 1-3, 5-7 ARE 0.040" (1.02mm) DIA. WITH 0.080" (2.03mm) DIA.  
STANDOFF SHOULDERS  
PINS 4 AND 8 ARE 0.062" (1.57mm) DIA. WITH 0.100" (2.54mm)  
DIA. STANDOFF SHOULDERS  
ALL PINS: MATERIAL: COPPER ALLOY FINISH: MATTE TIN OVER  
NICKEL PLATE  
UNDIMENSIONED COMPONENTS ARE SHOWN FOR VISUAL  
REFERENCE ONLY  
Vout(-)  
SENSE  
(-)  
5
6
7
8
TRIM  
SENSE  
(+)  
Vout(+)  
Positive output voltage  
Notes:  
ALL DIMENSIONS IN INCHES(mm) TOLERANCES: X.XXIN +/-0.02  
(X.Xmm +/-0.5mm) X.XXXIN +/-0.010 (X.XXmm +/-0.25mm)  
1)SENSE(–) should be connected to Vout(–) either remotely or at  
the converter  
2)SENSE(+) should be connected to Vout(+) either remotely or at  
the converter.  
9)  
Weight: 3oz (85g) typical  
10)  
Workmanship: Meets or exceeds IPC-A-610 Class II  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 2  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Flanged Mechanical Diagram  
OVERALL HEIGHT  
.500 .028  
[12,7  
0,71]  
.60 [15,2 ]  
.45 [11,4 ]  
.30 [7,6 ]  
.15 [3,8 ]  
.01 [0,2]  
2.200 .020 [55,88  
1.536 .020 [39,01  
0,5]  
0,5]  
.18  
[4,6 ]  
SEE NOTE 5 & 6  
USE W/ 4-40  
OR M3 SCREW (6x)  
RECOM. TORQUE  
3 in.lb  
.13[3,3]  
4
5
6
7
8
2.00  
[50,8 ]  
TOP VIEW  
2.07  
[52,5 ]  
2.386 .020  
1.66  
[42,2 ]  
[60,6  
0,5]  
1.01  
[25,7 ]  
.36  
[9,1 ]  
3
2
1
1
.30 [7,6 ]  
.125  
[3,2 ]  
.183 .020  
[4,65 0,5]  
BOTTOMSIDE CLEARANCE  
.010 .010  
.70  
[17,8 ]  
.60 [15,2 ]  
[0,51  
0,25]  
1.30  
[33 ]  
.02 [0,6 ]  
.800 .020  
[20,32  
0,5]  
NOTES  
PINꢀDESIGNATIONS  
1)  
2)  
3)  
4)  
APPLIED TORQUE PER SCREW SHOULD NOT EXCEED 5in-lb  
(3in-lb RECOMMENDED).  
BASEPLATE FLATNESS TOLERANCE IS 0.01" (.2mm)  
TIR FOR SURFACE.  
PINS 1-3, 5-7 ARE 0.040" (1.02mm) DIA. WITH 0.080" (2.03mm)  
DIA. STANDOFF SHOULDERS  
PINS 4 AND 8 ARE 0.062" (1.57mm) DIA. WITH 0.100" (2.54mm)  
DIA STANDOFF SHOULDERS.  
Pin Name ꢀFunction  
1
Vin(+) Positive input voltage  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
2
ON/OFF  
3
4
Vin(-) Negative input voltage, internal short to Pin 4  
Vout(–) Negative output voltage, internal short to Pin 3  
Negative remote sense. See note 1 (S option)  
Itrim (C option)  
TRIM Output voltage trim  
Positive remote sense. See note 2 (S option)  
Imon (C option)  
Vout(+) Positive output voltage  
SENSE  
(–)  
5
6
7
8
5)  
OTHER PIN EXTENSION LENGTHS AVAILABLE  
6)  
ALL PINS: MATERIAL: COPPER ALLOY  
FINISH: MATTE TIN OVER NICKEL PLATE  
SENSE  
(+)  
7)  
UNDIMENSIONED COMPONENTS ARE SHOWN FOR VISUAL  
REFERENCE ONLY  
8)  
Weight: 3.17oz (90g)  
Notes:  
1)SENSE(–) should be connected to Vout(–) either remotely or at  
9)  
ALL DIMENSIONS IN INCHES(mm).  
the converter  
TOLERANCES: X.XXIN +/-0.02 (X.Xmm +/-0.5mm)  
X.XXXIN +/-0.010 (X.XXmm +/-0.25mm)  
2)SENSE(+) should be connected to Vout(+) either remotely or at  
the converter.  
10)  
Recommended pin length is 0.03" (0.76 mm) greater than the PCB  
thickness.  
11)Workmanship: Meets or exceeds IPC-A-610 Class II  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 3  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Technical Specification  
NQ60x60QGx20 Electrical Characteristics  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24 V dc unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications  
subject to change without notice.  
Parameter  
ABSOLUTE MAXIMUM RATINGS  
Vout Min.  
Typ.  
Max. Units Notes & Conditions  
Input Voltage  
Non-Operating  
Operating  
Storage Temperature  
Voltage at ON/OFF input pin  
RECOMMENDED OPERATING CONDITIONS  
Input Voltage Range  
All  
All  
All  
All  
0
80  
60  
125  
5.5  
V
V
°C  
V
Continuous  
Continuous  
-45  
0
All  
All  
9
60  
25  
20  
V
A
A
µF  
V
A
Turn on at 10V  
Input Fuse Rating  
Fast blow external fuse recommended  
Input current max equals output rated current  
ESR < 1.5 Ω  
Input Current  
External Input Capacitance  
Output Voltage  
All  
All  
All  
100  
0
0
60  
20  
Output Current  
Output voltage dependent  
INPUT CHARACTERISTICS  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Hysteresis  
Input Current Limit  
No-Load Input Current  
All  
All  
All  
All  
12  
24  
48  
All  
All  
9.2  
8.1  
9.5  
8.5  
1.0  
24  
85  
115  
225  
35  
10  
8.9  
V
V
V
A
mA  
mA  
mA  
mA  
µF\µH\µF  
Disabled Input Current  
Input Filter Components Value (C\L\C)  
OUTPUT CHARACTERISTICS  
Output Voltage Range  
Operating Output Current Range  
Output Voltage Regulation  
Total Output Voltage Range  
Output Voltage Ripple and Noise (pk-pk/36Vin)  
8.8\2.2\26.4  
All  
All  
0
0
60  
20  
V
A
Set output by Rtrim resistor  
All  
12  
24  
48  
All  
All  
480 mV +4%*Vout  
Sense pin, over sample, line, load, temp. & life  
36 Vin Full Load; 100uF; 20 MHz b.w.  
"
15  
15  
40  
24  
mV  
mV  
mV  
A
Output DC Over Current limit  
External Output Capacitance  
C Option: Isense voltage  
No load  
Effective on input, output condition  
ESR > 1 mΩ  
0
1000  
µF  
All  
All  
All  
1.25  
1.83  
10  
V
V
kΩ  
Full load  
20 A load  
Output resistance of Isense  
C Option: Itrim voltage  
Voltage at no load  
All  
All  
All  
All  
All  
0.12  
2.12  
10.2  
2.5  
V
V
kΩ  
V
Voltage at maximum load  
Pull-Up Resistance of Itrim Pin  
Pull-Up Voltage  
20 A load  
C Option: Reverse Current  
EFFICIENCY  
2
µA  
Enabled or Disabled  
100% Load; 24 Vin  
100% Load; 48 Vin  
100% Load; 12 Vin  
50% Load; 24 Vin  
50% Load; 48 Vin  
50% Load; 12 Vin  
12  
24  
48  
12  
24  
48  
92  
95  
89  
94  
95  
92  
%
%
%
%
%
%
W mode only  
W mode only  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 4  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Technical Specification  
NQ60x60QGx20 Electrical Characteristics (Continued)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24 V dc unless otherwise noted; full operating temperature range is -40 °C to +105 °C ambient temperature with appropriate power derating. Specifications  
subject to change without notice.  
Parameter  
Vout Min. Typ. Max. Units Notes & Conditions  
DYNAMIC CHARACTERISTICS  
Output Voltage during Current Transient  
For a Step Change in Output Current  
Settling Time  
All  
1
V
(0.1 A/µs); 50%-75%-50% Iout max  
To within 1.5% Vout nom.  
All  
5
ms  
Turn on Transient  
Startup delay  
Rise Rate  
Output Voltage Overshoot  
FEATURE CHARACTERISTICS  
Switching Frequency  
All  
All  
All  
2
0.6  
ms  
V/ms  
V
Resistive load  
"
"
0
All  
240  
250  
260  
kHz  
ON/OFF Control  
Negative Logic (N) ON/OFF Control  
Off-State Voltage  
On-State Voltage  
Pull-Up Voltage  
Pull-Up Resistance  
Output Voltage Trim Range  
Input/Output Over-Voltage Protection  
Over-Temperature Shutdown  
Over-Temperature Shutdown Restart Hysteresis  
TEMP LIMITS FOR POWER DERATING  
Semiconductor Junction Temperature  
Board Temperature  
All  
All  
All  
All  
All  
All  
All  
All  
1.8  
0
3.3  
0.8  
V
V
V
kΩ  
V
V
3.3  
10  
0
66  
60  
75  
Measured Vout+ to common pins  
Over full temp range  
Average PCB Temperature  
72  
115  
15  
°C  
°C  
All  
All  
All  
125  
125  
100  
°C  
°C  
°C  
Package rated to 150 °C  
ULrated max operating temp 130 °C  
Baseplate Temperature  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (TR-NWT-000332; Telcordia)  
Calculated MTBF (MIL-HDBK-217F; MIL-217)  
Field Demonstrated MTBF  
All  
All  
All  
3.2  
3.0  
106 Hrs. 66% load, Tcase= 70°C  
106 Hrs. 66% load, Tcase= 70°C  
106 Hrs. See our website for details  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 5  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Standards & Qualifications  
Parameter  
STANDARDS COMPLIANCE  
Notes & Conditions  
UL 60950-1:2007  
CAN/CSA-C22.2 No. 60950-1:2007  
EN60950-1/A12:2011  
Needle Flame Test (IEC 695-2-2)  
IEC 61000-4-2  
Test on entire assembly; board & plastic components UL94V-0 compliant  
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)  
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new  
releases or download from the SynQor website.  
Parameter  
QUALIFICATION TESTING  
Life Test  
# Units Test Conditions  
32  
95% rated Vin and load, units at derating point, 1000 hours  
Vibration  
5
5
10  
5
10-55 Hz sweep, 0.060” total excursion, 1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x, y, and z axis  
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load  
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day  
MIL-STD-883, method 2003  
5
5
15 pins  
2
Solderability  
Altitude  
70,000 feet (21 km), see Note  
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 6  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Technical Charts  
100  
95  
90  
85  
80  
75  
70  
65  
60  
30  
25  
20  
15  
10  
5
48Vin 24Vout  
24Vin 12Vout  
48Vin 12Vout  
24Vin48Vout  
12Vin 24Vout  
12Vin 48Vout  
48Vin 24Vout  
24Vin 12Vout  
48Vin 12Vout  
24Vin 48Vout  
12Vin 24Vout  
12Vin 48Vout  
0
0
5
10  
15  
20  
0
5
10  
15  
20  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at different output voltage vs. load current for different  
Figure 2: Power dissipation at different output voltage vs. load current for  
input voltage at 25°C.  
different input voltage at 25°C.  
21  
18  
15  
12  
9
1 µH  
See Fig. 5  
source  
impedance  
See Fig. 6  
i
Dc-dc  
C
i
S
VIN  
VOUT  
Converter  
Tb=80 C; Vout=12 V  
Tb=100 C; Vout=12 V  
6
VSOURCE  
100 µF  
100mΩ ESR  
tantalum  
C*  
Tb=80 C; Vout=24 V  
Tb=100 C; Vout=24 V  
Tb=80 C; Vout=48 V  
Tb=100 C; Vout=48 V  
3
0
capacitor  
* See values for recommended external input capacitance.  
Inductor optional as needed.  
0
10  
20  
30  
40  
50  
60  
Input Voltage (V)  
Figure 3: Maximum output power derating curve with a controlled baseplate  
Figure 4: Test set-up diagram showing measurement points for Input Terminal  
temperature of 80ºC and 100ºC.  
Ripple Current (Figure 5), and Output Voltage Ripple (Figure 6).  
Figure 5: Input Terminal Ripple Current at 36V input and rated load current  
(500mA/div). Load capacitance: 100μF electrolytic cap. Bandwidth: 20MHz.  
See Figure 4  
Figure 6: Output Voltage Ripple at 36V input and rated load current (50mV/  
div). Load capacitance: 100µF electrolytic cap.. Bandwidth: 20MHz. See Figure  
4.  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 7  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Technical Charts  
Figure 7: Turn-on transient at 36V input; full load (20ms/div). ON/OFF input  
Figure 8: Turn-on transient at 36V input; zero load (20ms/div).ON/OFF input  
(5V/div)Ch 1-4: Vout (10V/div)  
(5V/div)Ch 1-4: Vout (10V/div)  
2.00  
1.50  
1.00  
0.50  
0.00  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
0
5
10  
15  
20  
0
5
10  
15  
20  
25  
Load (A)  
CurrentLimit (A)  
Figure 9: Imon pin voltage vs. load current at 24V input and 13.8V output. Load  
Figure 10: Current limit vs. Itrim pin voltage at 24V input and 13.8V output.  
capacitance: 100µF electrolytic cap. C option only.  
Load capacitance: 100µF electrolytic cap. C option only.  
Figure 11: Output voltage response for 36V input; 12V, 24V, 48V, 60V output  
to step-change in load current (50-75-50% of Iout max; di/dt = 0.1A/µs). Load  
cap: 100µF, 100mΩ ESR tant, Ch 1-4: Vout (2V/div); (5ms/div).  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 8  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Application Section  
BASIC OPERATION AND FEATURES  
PROTECTION FEATURES  
These converters use a digital controller for the buck stage Input Under-Voltage Lockout:  
The converter is  
and the boost stage. It automatically changes operating mode designed to turn off when the input voltage is too low,  
(buck or boost) when the line voltage or output set point which helps to avoid an input system instability problem  
changes. Both stages are accomplished with synchronous (described in more detail in the application note titled “Input  
rectifiers. Very high efficiency is maintained over wide input System Instability”). The lockout circuitry is a comparator  
and output voltage ranges by the change in operational mode with DC hysteresis. When the input voltage is rising, it must  
and the use of synchronous rectifiers.  
exceed the typical Turn-On Voltage Threshold value (listed  
on the specification page) before the converter will turn on.  
Once the converter is on, the input voltage must fall below  
the typical Turn-Off Voltage Threshold value before the  
converter will turn off.  
The converter runs at a fixed frequency with a predictable  
EMI performance.  
Note: Since this converter supports a wide range of input and  
output voltage, the current rating and current limit function  
affect both input and output current, whichever is higher at  
the time. When in buck mode, the output current is higher. In  
boost mode the input current is higher.  
Output Current Shutdown: To provide protection in an  
output short condition, the unit is equipped with internal  
short circuit protection. When the short circuit protection is  
triggered, the unit first shuts down. After an approximately  
16 ms inhibit time, the unit turns on again. If the short  
circuit condition remains, the current limit circuit will control  
the output current. The unit will operate normally once the  
fault condition is removed.  
CONTROL FEATURES  
REMOTE ON/OFF: The On/Off input permits the user to  
control when the converter is on or off. Only Negative ON/  
OFF logic is available in this power module series.  
The negative logic ON/OFF signal turns the module OFF when  
it is high (leave the pin floating or set its voltage between  
1.8~3.3 V) and turns the module ON when it is low (below  
0.8V with respect to Vin-).  
Internal Over-Voltage Protection (OVP): To protect  
the load against an excessive output voltage, an output  
over-voltage shutdown feature is included. This OVP is fixed  
and independent of the output voltage set point.  
OUTPUT VOLTAGE TRIM: The output voltage can be  
Over-Temperature Shutdown: A temperature sensor  
on the converter senses the average temperature of the  
module. The over temperature shutdown circuit is designed  
to turn the converter off when the temperature at the  
sensed location reaches the Over-Temperature Shutdown  
value. It will allow the converter to turn on again when the  
temperature of the sensed location falls by the amount of  
the Over-Temperature Shutdown Restart Hysteresis value.  
programmed to any voltage between 0Vdc and V  
by  
rated  
connecting one resistor between the Pin 6 (TRIM) pin and  
Pin 5 [Sense(-)](S-version) or Pin 4 [Vout(-)](C-version). For a  
desired output voltage, the value of the resistor is:  
11830 x Vrated  
_
R
Vtrim(Vout) =  
(
)  
10912  
+
V
0.0580 x V  
rated  
[( ) ]  
trim  
Alternatively, the TRIM pin can be driven from an external  
voltage source:  
Vtrim  
Vpin6 = 2.366 – 2.316  
Vrated  
( )  
Where, for both approaches:  
Vtrim = desired output voltage setpoint  
Vrated = rated output voltage  
Vpin6 = trim pin voltage (when driven externally)  
RVtrim = resistor value to set Vout  
Note: To maintain the accuracy of the output voltage over  
load current, it is vital that any trim resistor be connected to  
the converter’s Sense(-) pin (for the S-option) or Vout(-) pin  
(for the C-option), locally at the converter, not at a remote  
location nearer to the load. A separate Kelvin connection to  
the PCB pad for the Vout(-) is optimal for the C-option.  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 9  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Application Section  
APPLICATION CONSIDERATIONS  
Negative output: This series of converters can be  
connected to achieve a negative output from a positive  
input as shown in Fig A.  
Limited output voltage resolution: The internal voltage  
control feedback loop is digital and has limited resolution.  
Therefore, the output voltage will exhibit discrete steps as  
the loop responds to changes in line, load, trim, or remote  
sense. For instance, on close examination, the startup ramp  
has a “stair-step” shape. Likewise, a load transient response  
will be composed of multiple discrete steps.  
Vin-/  
Vout+  
Vin+  
Cin2  
1
2
8
7
6
5
Vout+  
SENSE+  
TRIM  
Vin+  
Input filtering: These modules should be connected to a  
low-impedance source. A highly inductive source can affect  
the stability of the module. An input capacitor with an ESR  
must be placed directly adjacent to the input pin of the  
module to minimize input ripple voltage and ensure module  
stability.  
Cout1  
Vout-  
ENABLE  
Cin1  
DC-DC  
Converter  
SENSE-  
RVtrim  
3
4
Vin-  
Vout-  
Figure A: Negative output setup  
See application note: Input System Instability  
(http://www.synqor.com/documents/appnotes/appnt_System_Instability.pdf)  
Using this negative output configuration impacts the available  
Output capacitance: No extra external capacitor is  
required. However, to reduce the output ripple and  
improve dynamic response to a step load change additional  
capacitance at the output can be used. Low ESR polymer  
and ceramic capacitors are recommended to improve the  
dynamic response of the module. The addition of external  
output capacitance may cause the start-up time to change.  
output voltage range and current limit.  
The output voltage range becomes 0 to (Vmax - Vin), and  
the current limit (for either the buck or boost modes) is  
scaled by:  
Vin  
I
=
* I  
rated  
rated(neg)  
(Vin + Vout)  
Remote sense (S-option only): Vout remote sensing  
is provided to achieve proper regulation at the load points  
and reduce effects of distribution losses on output line. The  
module can correct for a total of 10% drop in the output  
lines. In the event of an open remote sense line, the  
module will maintain regulation through an internal resistor  
connection.  
Current limit: The available power is limited by an output  
current limit in buck mode (when Vin>Vout) and by an input  
current limit in boost mode (when Vin<Vout).  
for Vin >Vout:  
I
= 1.2 x I  
limit  
max  
for Vin < Vout:  
Vin  
I
= 1.2 x I  
x
limit  
max  
( )  
Vout  
where I  
max  
= maximum rated output current  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 10  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Application Section  
Output current limit trim: The output current limit can  
be set to any value between zero and I by choosing the  
C-FEATURE  
trimmable current limit (C-option)  
In addition to voltage trim, the C-option offers an adjustable  
SET  
(Current  
monitor/  
rated  
value of R  
as follows:  
Itrim  
current limit trim and a current monitor I  
not have remote sense.  
pin. It does  
mon  
0.0469 Irated + Itrim  
1.153 Irated - Itrim  
RItrim  
=
10200 - 10  
(Ω)  
[(  
) ]  
Zero back-drive current: The C-option includes an ideal  
diode circuit in series with the Vout+ pin that prevents  
reverse current flow. This enables applications such as  
battery charging, current sharing, and current monitoring.  
Where  
I
I
= desired current limit setpoint  
trim  
= rated maximum converter current  
rated  
Alternatively, the I  
voltage source:  
pin can be driven from an external  
trim  
C-Option Connection  
V
= 2.085(I  
/I  
) + 0.0953  
DC-DC  
Converter  
(pin5)  
trim rated  
Vout+  
Vin+  
Cin  
where I  
is the desired current limit setpoint  
trim  
1
2
8
7
6
5
Vout+  
Vin+  
IMON  
Note: It is possible to choose R  
is greater than I  
continuous operation above I  
such as that I  
trim  
IMON  
Itrim  
Output  
, but SynQor does not recommend  
Cout  
TRIM  
ENABLE  
rated  
.
rated  
ITRIM  
Vout-  
3
4
RItrim  
Vin-  
RVtrim  
Note: When in boost-mode, the output current could still  
be limited by the maximum current limit, I  
the input current.  
Vout-  
Vin-  
, applied to  
OCL  
Figure B: Current monitor/trimmable current limit setup  
Current monitor: The I  
mon  
pin voltage tracks the output  
Output voltage trim: The RV resistor increases the  
output voltage, identical in function to the S-option (p.9).  
trim  
current, as shown in figure 9. Zero load current is 1.25V and  
maximum rated load current is 1.83V. This pin has a 49.9  
Ohm output impedance.  
Output current limit: There are three levels of current  
that must be understood when considering the term  
“Output Current Limit” as listed below:  
Imon  
49.9  
1.25V  
I
= over-current limit (from datasheet Output Charac-  
OCL  
teristics: Output DC Over Current Limit). This is a built in  
Figure D: Current monitor circuit  
fixed value of current at which the converter will limit.  
I
I
= rated current of the converter (input or output)  
rated  
= desired output current limit  
trim  
Figure C shows the relationship among these three cur-  
rents.  
I
OCL  
I
rated  
I
trim  
Figure C: Relationship of output current terms.  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 11  
9-60V  
Input:  
Outputs:  
Current:  
Package  
0-60V  
20A  
Quarter-brick  
Ordering Information  
PART NUMBERING SYSTEM  
ORDERING INFORMATION  
The part numbering system for SynQor’s dc-dc converters  
follows the format shown in the example below.  
The tables below show the valid model numbers and ordering  
options for converters in this product family. When ordering  
SynQor converters, please ensure that you use the complete  
15 character part number consisting of the 12 character base  
part number and the additional 3 characters for options.  
Add “-G” to the model number for 6/6 RoHS compliance.  
NQ 60 W 60  
Q
G
C 20 N N S - G  
6/6 RoHS  
Options (see  
Ordering Information)  
Input  
Voltage  
Output  
Voltage  
Max Output  
Current  
Model Number  
Output Current  
Thermal Design  
Performance Level  
Package Size  
Output Voltage  
Mode (see Ordering Information)  
Input Voltage  
Product Family  
NQ60w60QGx20yz-G  
9-60V  
0-60V  
20A  
The following options must be included in place of the w x y z  
spaces in the model numbers listed above.  
Options Description: x y z  
Mode: w  
Enable  
Logic  
Thermal Design  
Pin Style  
Feature Set  
S - Standard  
C - Current  
monitor  
C - Encased  
K - 0.110"  
N - 0.145"  
T - Buck  
N -  
output /  
Trimmable  
current limit  
The first 12 characters comprise the base part number and  
the last 3 characters indicate available options. The “-G”  
suffix indicates 6/6 RoHS compliance.  
W - Buck / V - Encased  
Boost with Flanged  
Baseplate  
Negative R - 0.180"  
Y - 0.250"  
Application Notes  
A variety of application notes and technical white papers can  
be downloaded in pdf format from our website.  
Not all combinations make valid part numbers, please contact  
SynQor for availability. See the Product Summary web page for  
more options.  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium,  
Hexavalent Chromium, Mercury, Polybrominated Biphenyls  
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical  
and Electronic Equipment. This SynQor product is 6/6 RoHS  
compliant. For more information please refer to SynQor’s  
RoHS addendum available at our RoHS Compliance / Lead Free  
PATENTS  
SynQor holds the following U.S. patents, one or more of which  
apply to each product listed in this document. Additional patent  
applications may be pending or filed in the future.  
Initiative web page or e-mail us at rohs@synqor.com  
.
5,999,417 6,222,742 6,545,890 6,577,109 6,594,159 6,731,520  
6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146  
7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702  
7,765,687 7,787,261  
8,023,290 8,149,597 8,493,751  
Contact SynQor for further information and to order:  
Phone: 978-849-0600  
Toll Free:1-888-567-9596  
Warranty  
SynQor offers a three (3) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from SynQor.  
Fax:  
E-mail: power@synqor.com  
Web: www.synqor.com  
978-849-0602  
Information furnished by SynQor is believed to be accurate and reliable.  
However, no responsibility is assumed by SynQor for its use, nor for any  
infringements of patents or other rights of third parties which may result  
from its use. No license is granted by implication or otherwise under any  
patent or patent rights of SynQor.  
Address: 155 Swanson Road  
Boxborough, MA 01719  
USA  
Product # NQ60x60QGx20  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-NQ6060W Rev. K  
02/11/14  
Page 12  

相关型号:

NQ60W60EGC05NKC-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NKS-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NNC-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NNS-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NRC-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NRS-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NYC-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGC05NYS-G

Eighth-brick DC-DC Converter
SYNQOR

NQ60W60EGV05NNS-G

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, EIGHTH BRICK PACKAGE-8
SYNQOR

NQ60W60EGV05NRC-G

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, EIGHTH BRICK PACKAGE-8
SYNQOR

NQ60W60EGV05NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, EIGHTH BRICK PACKAGE-8
SYNQOR

NQ60W60ETC05NNC-G

DC-DC Regulated Power Supply Module, 1 Output, 600W, Hybrid, ROHS COMPLIANT, EIGHTH BRICK PACKAGE-8
SYNQOR