IQ24050HZV60NRA-G [SYNQOR]

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8;
IQ24050HZV60NRA-G
型号: IQ24050HZV60NRA-G
厂家: SYNQOR WORLDWIDE HEADQUARTERS    SYNQOR WORLDWIDE HEADQUARTERS
描述:

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8

局域网
文件: 总27页 (文件大小:3308K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Technical  
Specification  
IQ24xxxHZXxx  
18-36V  
50V  
5.0-50V 504W  
2250V dc  
Half-brick  
DC-DC Converter  
Continuous Input Transient Input  
Outputs  
Max Power  
Isolation  
The InQor Half-brick converter series is composed of next-  
generation, board-mountable, fixed switching frequency dc-  
dc converters that use synchronous rectification to achieve  
extremely high power conversion efficiency. Each module  
is supplied completely encased to provide protection  
from the harsh environments seen in many industrial and  
transportation applications.  
I
Q
2
4
0
C
5
N
.
D
0
V
0
C
H
Z
C
-
D
C
6
0
R
6
O
5
1
N
8
R
-
3
E
A
-
G
6
R
T
E
V
I
N
V
Operational Features  
O
@
U
T
0
A
• High efficiency, 94% at full rated load current  
• Operating input voltage range: 18-36V  
• Fixed frequency switching provides predictable EMI  
• No minimum load requirement  
• Optional: Active current share for parallel applications  
ection Features  
Mechanical Features  
ut under-voltage lockout  
put current limit and short circuit protection  
ve back bias limit  
• Industry standard Half-brick pin-out  
• Size: 2.386" x 2.486" x 0.512" (60.60 x 63.14 x 13.00 mm)  
Total weight: 4.9 oz (139 g)  
o-recovery output over-voltage protection  
rmal shutdown  
• Flanged baseplate version available  
Control Features  
CONTENTS  
• On/Off control referenced to input side  
Page No.  
• Remote sense for the output voltage  
Family Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Electrical Characteristics (5.0 Vout) & Figures . . . . . . . . . . . . . . . . . . . 4  
Electrical Characteristics (12 Vout) & Figures . . . . . . . . . . . . . . . . . . . . 6  
Electrical Characteristics (15 Vout) & Figures . . . . . . . . . . . . . . . . . . . . 8  
Electrical Characteristics (24 Vout) & Figures . . . . . . . . . . . . . . . . . . . .10  
Electrical Characteristics (28 Vout) & Figures . . . . . . . . . . . . . . . . . . . .12  
Electrical Characteristics (40 Vout) & Figures . . . . . . . . . . . . . . . . . . . .14  
Electrical Characteristics (50 Vout) & Figures . . . . . . . . . . . . . . . . . . . .16  
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
Standard Mechanical Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
• Wide output voltage trim range of at least -50%, +10%  
Safety Features  
• UL 60950-1/R:2011-12 Basic Insulation  
• CAN/CSA-C22.2 No. 60950-1/A1:2011  
• EN 60950-1/A12:2011  
• RoHS compliant (see last page)  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 1  
Technical  
Specification  
IQ24xxxHZXxx  
IQ24 FAMILY ELECTRICAL CHARACTERISTICS (all output voltages)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Min.  
Typ.  
Max. Units Notes & Conditions  
Non-Operating  
Operating  
Operating Transient Protection  
Isolation Voltage  
-1  
50  
40  
50  
V
V
V
Continuous  
Continuous  
1 s transient, square wave  
Input to Output  
Input to Base-Plate  
Output to Base-Plate  
Operating Temperature  
2250  
2250  
2250  
100  
125  
18  
V dc  
V dc  
V dc  
°C  
°C  
V
-40  
-45  
-2  
Baseplate temperature  
50V transient for 1 s  
Storage Temperature  
Voltage at ON/OFF input pin  
INPUT CHARACTERISTICS  
Operating Input Voltage Range  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Voltage Hysteresis  
Input Over-Voltage Shutdown  
Recommended External Input Capacitance  
Input Filter Component Values (C1\Lin\C2)  
DYNAMIC CHARACTERISTICS  
Turn-On Transient  
18  
24  
36  
V
16.5  
15.0  
1.0  
17.0  
15.5  
1.5  
17.5  
16.0  
2.0  
V
V
V
V
µF  
-
Not Available  
Typical ESR 0.1-0.2 Ω  
470  
47\0.34\23  
nF\µH\µF Internal values; see Figure D  
Turn-On Time  
24  
35  
40  
5
ms  
%
ms  
Full load, Vout=90% nom; See Note 2  
Maximum Output Capacitance  
See Application Section  
Output Voltage Overshoot  
Auto-recovery Startup Inhibit Time  
ISOLATION CHARACTERISTICS  
Isolation Voltage (dielectric strength)  
Isolation Resistance  
500  
See Absolute Maximum Ratings  
See Note 1  
30  
1000  
MΩ  
pF  
Isolation Capacitance (input to output)  
TEMPERATURE LIMITS FOR POWER DERATING CURVES  
Semiconductor Junction Temperature  
Board Temperature  
Transformer Temperature  
Maximum Baseplate Temperature, Tb  
FEATURE CHARACTERISTICS  
125  
125  
125  
100  
°C  
°C  
°C  
°C  
Package rated to 150 °C  
UL rated max operating temp 130 °C  
Switching Frequency  
ON/OFF Control  
Off-State Voltage  
On-State Voltage  
230  
240  
250  
kHz  
V
Insolation stage switching freq. is half this  
2.4  
-2.0  
18.0  
0.8  
ON/OFF Control  
Pull-Up Voltage  
Pull-Up Resistance  
Over-Temperature Shutdown OTP Trip Point  
Over-Temperature Shutdown Restart Hysteresis  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (Telcordia) TR-NWT-000332  
Calculated MTBF (MIL-217) MIL-HDBK-217F  
Field Demonstrated MTBF  
Application notes Figure A  
28, 50Vout\All Other Vout  
kΩ\kΩ 28, 50Vout\All Other Vout  
5\15  
10\50  
125  
5.5\18  
V\V  
°C  
°C  
Average PCB Temperature  
10  
1.44  
1.2  
106 Hrs. Tb = 70°C  
106 Hrs. Tb = 70°C  
106 Hrs. See our website for details  
Note 1: Higher values of isolation capacitance can be added external to the module.  
Note 2: Additional 30ms between enable and start of Turn-On time for full-featured units to set up communication (N/A to 28V and 50V)  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 2  
Technical  
Specification  
IQ24xxxHZXxx  
Family Figures (all output voltages)  
120  
100  
80  
60  
40  
20  
0
Typical Current Limit Inception Point  
Nominal Vout  
Typical Output Voltage at Shutdown  
Vin min  
Vin nom  
Vin max  
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150  
Load Current (%)  
Common Figure 1: Startup Waveform (typical). Input voltage pre-applied, ON/  
Common Figure 2: Output I-V Characteristics (output voltage vs. load current)  
OFF Pin on Ch 2.  
showing typical current limit curves and converter shutdown points.  
Common Figure 3: Trim-Up Graph for 5.0 to 15V outputs.  
Common Figure 4: Trim-Up Graph for 24 to 50V outputs.  
Common Figure 5: Trim-Down Graph for all outputs.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 3  
Input:18-36V  
Output:5.0V  
Current:60A  
Part No.:IQ24050HZx60  
Technical Specification  
IQ24050HZx60 ELECTRICAL CHARACTERISTICS (5.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
20  
350  
5
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
290  
3
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
0.95  
500  
See Figure 6  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
4.918  
5.000  
5.070  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-125  
125  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
4.850  
5.150  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
135  
32  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.2 A/µs)  
Settling Time  
0
60  
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
66.0  
72.0  
78.0  
A
2
6
3
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
4
mA  
µF  
20,000  
150  
500  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
5.9  
10  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
6.2  
6.4  
Over full temp range  
100% Load  
92  
93  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 4  
Input:18-36V  
Output:5.0V  
Current:60A  
Part No.:IQ24050HZx60  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
40  
35  
30  
25  
20  
15  
10  
5
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
0
6
12  
18  
24  
30  
36  
42  
48  
54  
60  
0
6
12  
18  
24  
30  
36  
42  
48  
54  
60  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
80  
70  
60  
50  
40  
30  
80  
70  
60  
50  
40  
30  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
20  
20  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
10  
0
10  
100 LFM (0.5 m/s)  
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2" heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.2A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout (20A/div).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 5  
Input:18-36V  
Output:12V  
Current:42A  
Part No.:IQ24120HZx42  
Technical Specification  
IQ24120HZx42 ELECTRICAL CHARACTERISTICS (12.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
33  
375  
5
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
310  
3
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
2
See Figure 6  
500  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
11.80  
12.00  
12.17  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-300  
300  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
11.64  
12.36  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
100  
24  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
42  
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
46.2  
50.4  
54.6  
A
5
6
3
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
4
mA  
µF  
12,000  
300  
500  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
10  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
14.2  
14.8  
15.4  
Over full temp range  
100% Load  
94  
95  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 6  
Input:18-36V  
Output:12V  
Current:42A  
Part No.:IQ24120HZx42  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
60  
50  
40  
30  
20  
10  
0
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
6
12  
18  
24  
30  
36  
42  
0
6
12  
18  
24  
30  
36  
42  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
48  
42  
36  
30  
24  
18  
48  
42  
36  
30  
24  
18  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
12  
12  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
6
0
6
100 LFM (0.5 m/s)  
0
25  
40  
55  
Ambient Air Temperature (°C)  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Figure 3: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2" heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs. Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout (20 A/div).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 7  
Input:18-36V  
Output:15V  
Current:34A  
Part No.:IQ24150HZx34  
Technical Specification  
IQ24150HZx34 ELECTRICAL CHARACTERISTICS (15.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
34  
400  
5
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
340  
3
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
2.5  
500  
See Figure 6  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
14.75  
15.00  
15.21  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-375  
375  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
14.55  
15.45  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
100  
20  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
34  
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
37.4  
40.8  
44.2  
A
6
6
3
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
4
mA  
µF  
10,000  
500  
250  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
10  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
17.7  
18.5  
19.2  
Over full temp range  
100% Load  
94.0  
94.5  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
with a 500ms off-time  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 8  
Input:18-36V  
Output:15V  
Current:34A  
Part No.:IQ24150HZx34  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
60  
50  
40  
30  
20  
10  
0
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34  
Load Current (A)  
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
42  
36  
30  
24  
18  
42  
36  
30  
24  
18  
12  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
12  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
6
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
6
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2" heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs. Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout (20 A/div).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 9  
Input:18-36V  
Output:24V  
Current:21A  
Part No.:IQ24240HZx21  
Technical Specification  
IQ24240HZx21 ELECTRICAL CHARACTERISTICS (24.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
33  
360  
5
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
300  
3
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
3
See Figure 6  
500  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
23.60  
24.00  
24.34  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-600  
600  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
23.28  
24.72  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
450  
150  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.2 A/µs)  
Settling Time  
0
21  
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
23.1  
25.2  
9.6  
3
27.3  
A
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
3
4
mA  
µF  
6000  
950  
500  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
10  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
28.3  
29.5  
30.7  
Over full temp range  
100% Load  
94  
95  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
with a 500ms off-time  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 10  
Input:18-36V  
Output:24V  
Current:21A  
Part No.:IQ24240HZx21  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
70  
60  
50  
40  
30  
20  
10  
0
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
3
6
9
12  
15  
18  
21  
0
3
6
9
12  
15  
18  
21  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
24  
21  
18  
15  
12  
9
24  
21  
18  
15  
12  
9
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
6
6
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
3
0
3
100 LFM (0.5 m/s)  
0
25  
40  
55  
Ambient Air Temperature (°C)  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2” heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 3: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs. Load cap: 1µF ceramic cap. Ch 1:  
Vout, Ch 2: Iout (10 A/div).  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 11  
Input:18-36V  
Output:28V  
Current:18A  
Part No.:IQ24280HZx18  
Technical Specification  
IQ24280HZx18 ELECTRICAL CHARACTERISTICS (28.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
37  
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
300  
100  
2.5  
380  
160  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
See Figure 6  
500  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
27.54  
28.00  
28.39  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-700  
700  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
27.16  
28.84  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
150  
40  
300  
80  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.2 A/µs)  
Settling Time  
0
18  
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
19.5  
21.0  
11.2  
5
22.5  
A
V
4
0
6
4
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
3
mA  
µF  
5000  
1.5  
8
V
ms  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
20  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
35.0  
36.4  
37.8  
Over full temp range  
100% Load  
93  
95  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
with a 500ms off-time  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 12  
Input:18-36V  
Output:28V  
Current:18A  
Part No.:IQ24280HZx18  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
60  
55  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
0
3
6
9
12  
15  
18  
0
3
6
9
12  
15  
18  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
18  
15  
12  
9
18  
15  
12  
9
6
6
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
3
3
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2" heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs. Load cap: 100µF electrolytic cap and  
1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (10 A/div).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 13  
Input:18-36V  
Output:40V  
Current:13A  
Part No.:IQ24400HZx13  
Technical Specification  
IQ24400HZx13 ELECTRICAL CHARACTERISTICS (40.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
33  
350  
5
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
280  
3
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
3.5  
400  
See Figure 6  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
39.34  
40.00  
40.56  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-1000  
38.80  
1000  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
41.20  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
100  
25  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.2 A/µs)  
Settling Time  
0
12.5  
16.3  
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
13.8  
15.0  
16  
3
A
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
3
4
mA  
µF  
1500  
2.2  
V
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
500  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
10  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
47.2  
49.2  
51.2  
Over full temp range  
100% Load  
93  
95  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
with a 500ms off-time  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 14  
Input:18-36V  
Output:40V  
Current:13A  
Part No.:IQ24400HZx13  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
60  
50  
40  
30  
20  
10  
0
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
0
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
16  
14  
12  
10  
8
16  
14  
12  
10  
8
6
6
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
4
4
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
2
0
2
100 LFM (0.5 m/s)  
0
25  
40  
55  
Ambient Air Temperature (°C)  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Figure 3: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2" heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs. Load cap: 1µF ceramic cap. Ch 1:  
Vout, Ch 2: Iout (5 A/div).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 15  
Input:18-36V  
Output:50V  
Current:10A  
Part No.:IQ24500HZx10  
Technical Specification  
IQ24500HZx10 ELECTRICAL CHARACTERISTICS (50.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 24V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
33  
A
mA  
mA  
V
100% Load, 18V Vin, trimmed up 10%  
300  
100  
4
380  
160  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
See Figure 6  
500  
mA  
A
RMS  
40  
Fast acting external fuse recommended  
49.18  
50.00  
50.70  
V
See Note 3  
±0.25  
±0.25  
%
%
mV  
V
Over Load  
Over Temperature  
-1250  
48.50  
1250  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
51.50  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
250  
60  
500  
120  
10  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.2 A/µs)  
Settling Time  
0
Subject to thermal derating  
Output voltage 10% Low  
See Note 2  
11.0  
12.0  
20  
3
13.0  
A
V
2
0
4
7
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
3
mA  
µF  
1000  
2
8
V
ms  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-50  
10  
10  
Across Pins 8&4; Common Figures 3-5;  
Across Pins 8&4  
56.5  
59.0  
61.5  
Over full temp range  
100% Load  
94  
95  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications  
support (e-mail: support@synqor.com)  
Note 2: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode,  
with a 500ms off-time  
Note 3: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 16  
Input:18-36V  
Output:50V  
Current:10A  
Part No.:IQ24500HZx10  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
60  
55  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
18Vin  
24Vin  
36Vin  
18Vin  
24Vin  
36Vin  
0
0
2
4
6
8
10  
0
2
4
6
8
10  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
Figure 2: Power Dissipation at nominal output voltage vs. load current for  
nominal, and maximum input voltage at 25°C.  
minimum, nominal, and maximum input voltage at 25°C.  
10.0  
9.0  
8.0  
7.0  
6.0  
5.0  
4.0  
10.0  
9.0  
8.0  
7.0  
6.0  
5.0  
4.0  
3.0  
3.0  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
2.0  
2.0  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
1.0  
1.0  
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0.0  
0.0  
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Thermal Derating (max output currnet vs. ambient air temperature)  
for encased converter without heatsink, at airflow rates of 100 LFM through 400  
LFM. Air flows across the converter from input to output (nominal input voltage).  
Figure 4: Thermal Derating (max output current vs. ambient air temperature)  
for encased converter with 1/2" heatsink, at airflow rates of 100 LFM through  
400 LFM. Air flows across the converter from input to output (nominal input  
voltage).  
Figure 5: Output Voltage Response to Step-Change in Load Current (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs. Load cap: 100µF electrolytic cap and  
1µF ceramic cap. Ch 1: Vout, Ch 2: Iout (5 A/div).  
Figure 6: Output Voltage Response to Step-Change in Input Voltage (250 V/  
ms), at Max. load current. Load cap: 100µF electrolytic cap and 1µF ceramic  
cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 17  
Technical  
Specification  
IQ24xxxHZXxx  
Application Section  
BASIC OPERATION AND FEATURES  
CONTROL FEATURES  
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits  
the user to control when the converter is on or off. This input is  
referenced to the return terminal of the input bus, Vin(-).  
This converter series uses  
a
two-stage power conversion  
topology. The first stage keeps the output voltage constant over  
variations in line, load, and temperature. The second stage uses  
a transformer to provide the functions of input/output isolation  
and voltage step-down to achieve the low output voltage required.  
In negative logic versions, the ON/OFF signal is active low  
(meaning that a low voltage turns the converter on). In positive  
logic versions, the ON/OFF input is active high (meaning that a  
high voltage turns the converter on). Figure A details possible  
circuits for driving the ON/OFF pin. Figure B is a detailed look of  
the internal ON/OFF circuitry. See Ordering Information page for  
available enable logics.  
Both the first stage and the second stage switch at a fixed  
frequency for predictable EMI performance. Rectification of the  
transformer’s output is accomplished with synchronous rectifiers.  
These devices, which are MOSFETs with a very low on-state  
resistance, dissipate significantly less energy than Schottky  
diodes, enabling the converter to achieve high efficiency.  
REMOTE SENSE Pins 8(+) and 6(-): The SENSE(+) and  
SENSE(-) inputs correct for voltage drops along the conductors  
that connect the converter’s output pins to the load.  
Pin 8 should be connected to Vout(+) and Pin 6 should be  
connected to Vout(-) at the point on the board where regulation  
is desired. If these connections are not made, the converter will  
deliver an output voltage that is slightly higher than its specified  
value.  
Dissipation throughout the converter is so low that it does not  
require a heatsink or even a baseplate for operation in many  
applications; however, adding a heatsink provides improved  
thermal derating performance in extreme situations. To further  
withstand harsh environments and thermally demanding  
applications, certain models are available totally encased. See  
Ordering Information page for available thermal design options.  
Note: The Output Over-Voltage Protection circuit senses the  
voltage across the output (Pins 9 and 5) to determine when it  
should trigger, not the voltage across the converter’s sense leads  
(Pins 8 and 6). Therefore, the resistive drop on the board should  
be small enough so that output OVP does not trigger, even during  
load transients.  
SynQor half-brick converters use the industry standard footprint  
and pin-out.  
ON/OFF  
ON/OFF  
ON/OFF  
OUTPUT VOLTAGE TRIM (Pin 7): The TRIM input permits the  
user to adjust the output voltage across the sense leads up or down  
according to the trim range specifications. SynQor uses industry  
standard trim equations.  
Vin(_)  
Vin(_)  
Vin(_)  
Remote Enable Circuit  
To decrease the output voltage, the user should connect a resistor  
between Pin 7 (TRIM) and Pin 6 (SENSE(–) input). For a desired  
decrease of the nominal output voltage, the value of the resistor  
should be:  
Negative Logic  
(Permanently  
Enabled)  
Positive Logic  
(Permanently  
Enabled)  
5V  
ON/OFF  
100%  
2  
TTL/  
CMOS  
ON/OFF  
Vin(_)  
Rtrim-down =  
(
|
)
kΩ  
Δ%  
where  
Vin(_)  
Open Collector Enable Circuit  
Vnominal – Vdesired  
Direct Logic Drive  
Δ% =  
|
× 100%  
Vnominal  
Figure A: Various Circuits for Driving the ON/OFF Pin  
18V(max)  
5V  
To increase the output voltage, the user should connect a resistor  
between Pin 7 (TRIM) and Pin 8 (SENSE(+) input). For a desired  
increase of the nominal output voltage, the value of the resistor  
should be:  
50k  
ON/OFF  
10k  
Vnominal  
2  
(
)
× Vdesired + Vnominal  
kΩ  
TTL  
Rtrim-up =  
1.225  
Vdesired – Vnominal  
Vin(_)  
Figure B: Internal ON/OFF Pin Circuitry  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 18  
Technical  
Specification  
IQ24xxxHZXxx  
Application Section  
The Trim Graph in Technical Features shows the relationship  
between the trim resistor value and Rtrim-up and Rtrim-down,  
showing the total range the output voltage can be trimmed up or  
down.  
Note: The TRIM feature does not affect the voltage at which the  
output over-voltage protection circuit is triggered. Trimming the  
output voltage too high may cause the over-voltage protection  
circuit to engage, particularly during transients.  
Protection Features  
Input Under-Voltage Lockout (UVLO): The converter is  
designed to turn off when the input voltage is too low, helping to  
avoid an input system instability problem, which is described in  
more detail in the application note titled “Input System Instability”  
on the SynQor website. The lockout circuitry is a comparator with  
DC hysteresis. When the input voltage is rising, it must exceed the  
typical “Turn-On Voltage Threshold” value* before the converter  
will turn on. Once the converter is on, the input voltage must  
fall below the typical Turn-Off Voltage Threshold value before the  
converter will turn off.  
It is not necessary for the user to add capacitance at the TRIM pin.  
The node is internally filtered to eliminate noise.  
Output Current Limit (OCP): If the output current exceeds  
the “Output DC Current Limit Inception” value*, then a fast linear  
current limit controller will reduce the output voltage to maintain  
a constant output current. If as a result, the output voltage falls  
below the “Output DC Current Limit Shutdown Voltage”* for more  
than 50 ms, then the unit will enter into hiccup mode, with a 500  
ms off-time. The unit will then automatically attempt to restart.  
Total DC Variation of Vout: For the converter to meet its full  
specifications, the maximum variation of the DC value of Vout, due  
to both trimming and remote load voltage drops, should not be  
greater than that specified for the output voltage trim range.  
Back-Drive Current Limit: If there is negative output current  
of a magnitude larger than the “Back-Drive Current Limit while  
Enabled” specification*, then a fast back-drive limit controller will  
increase the output voltage to maintain a constant output current.  
If this results in the output voltage exceeding the “Output Over-  
Voltage Protection” threshold*, then the unit will shut down.  
Output Over-Voltage Limit (OVP): If the voltage across the  
output pins exceeds the Output Over-Voltage Protection threshold,  
the converter will immediately stop switching. This prevents  
damage to the load circuit due to 1) excessive series resistance in  
output current path from converter output pins to sense point, 2)  
a release of a short-circuit condition, or 3) a release of a current  
limit condition. Load capacitance determines exactly how high  
the output voltage will rise in response to these conditions. After  
500ms the converter will automatically restart for all but the S  
Feature Set option, which is latching and will not restart until input  
power is cycled or the ON/OFF input is toggled.  
Over-Temperature Shutdown (OTP): A temperature sensor  
on the converter senses the average temperature of the module.  
The thermal shutdown circuit is designed to turn the converter off  
when the temperature at the sensed location reaches the “Over-  
Temperature Shutdown” value*. It will allow the converter to turn  
on again when the temperature of the sensed location falls by the  
amount of the “Over-Temperature Shutdown Restart Hysteresis”  
value*.  
Startup Inhibit Period: The Startup Inhibit Period ensures that  
the converter will remain off for approximately 500 ms when it is  
shut down due to a fault. This generates a 2 Hz “hiccup mode,”  
which prevents the converter from overheating. In all, there  
are three ways that the converter can be shut down, initiating a  
Startup Inhibit Period:  
• Output Over-Voltage Protection  
• Current Limit  
• Short Circuit Protection  
* See Electrical Characteristics section.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 19  
Technical  
Specification  
IQ24xxxHZXxx  
Application Section  
APPLICATION CONSIDERATIONS  
Input System Instability: This condition can occur because any  
DC-DC converter appears incrementally as a negative resistance  
load. A detailed application note titled “Input System Instability” is  
available on the SynQor website which provides an understanding  
of why this instability arises, and shows the preferred solution for  
correcting it.  
Thermal Considerations: For baseplated and encased versions,  
the max operating baseplate temperature, TB, is 100ºC. Refer to  
the Thermal Derating Curves in the Technical Figures section to  
see the available output current at baseplate temperatures below  
100ºC.  
A power derating curve can be calculated for any heatsink that is  
attached to the base-plate of the converter. It is only necessary to  
determine the thermal resistance, RTHBA, of the chosen heatsink  
between the baseplate and the ambient air for a given airflow  
rate. This information is usually available from the heatsink vendor.  
The following formula can the be used to determine the maximum  
power the converter can dissipate for a given thermal condition if  
its base-plate is to be no higher than 100ºC.  
Application Circuits: A typical circuit diagram, Figure C below  
details the input filtering and voltage trimming.  
Input Filtering and External Input Capacitance: Figure  
D below shows the internal input filter components. This filter  
dramatically reduces input terminal ripple current, which otherwise  
could exceed the rating of an external electrolytic input capacitor.  
The recommended external input capacitance is specified in the  
Input Characteristics section of the Electrical Specifications. More  
detailed information is available in the application note titled “EMI  
Characteristics” on the SynQor website.  
max  
100ºC - TA  
RTHBA  
=
P
diss  
This value of maximum power dissipation can then be used in  
conjunction with the data shown in the Power Dissipation Curves  
in the Technical Figures section to determine the maximum load  
current (and power) that the converter can deliver in the given  
thermal condition.  
Output Filtering and External Output Capacitance: The  
internal output filter components are shown in Figure D below.  
This filter dramatically reduces output voltage ripple. Some  
minimum external output capacitance is required, as specified in  
the Output Characteristics area of the Electrical Characteristics  
section. No damage will occur without this capacitor connected,  
but peak output voltage ripple will be much higher.  
For convenience, Thermal Derating Curves are provided in the  
Technical Figures section.  
Vout(+)  
Vin(+)  
Vsense(+)  
Electrolytic  
Capacitor  
External  
Input  
Filter  
Rtrim-up  
Vin  
Trim  
or  
ON/OFF  
Vin(_)  
Cload  
Rtrim-down  
Iload  
Vsense(_)  
Vout(_)  
Figure C: Typical Application Circuit (negative logic unit, permanently enabled)  
Lin  
Vin(+)  
Vout(+)  
Vout(-)  
Regulation  
Stage  
Current  
Sense  
Isolation  
Stage  
C2  
C1  
Vin(_)  
Figure D: Internal Input and Output Filter Diagram (component values listed in Electrical Characteristics section)  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 20  
Technical  
Specification  
IQ24xxxHZXxx  
Application Section  
ACTIVE CURRENT SHARE  
• The SHARE(+) and SHARE(-) pins should be routed between  
all paralleled units as a differential pair.  
Overview: The full-featured option, specified by an “F” in the  
last character in the part number, has current sharing operation  
supported, achieved by adding two additional pins: SHARE(+) and  
SHARE(-).  
• The ON/OFF pins should be connected in parallel, and  
rise/fall times should be kept below 2 ms.  
Connection of Paralleled Units: Up to 100 units can be placed in  
parallel. In this current share architecture, one unit is dynamically  
chosen to act as a master, controlling all other units. It cannot be  
predicted which unit will become the master at any given time, so  
units should be wired symmetrically (see Figures E & F).  
• The SENSE(+) and SENSE(-) pins should be connected either  
locally at each unit or separately to a common sense point.  
If an output common-mode choke is used, sense lines  
should be connected on the module-side of the choke.  
• If the TRIM pin is used, then each unit should have its own  
trim resistor connected locally between TRIM and SENSE(+)  
or SENSE(-).  
• Input power pins and output power pins should be tied  
together between units, preferably with wide overlapping  
copper planes, after any input common-mode choke.  
470 nH (nom)  
Vout(+)  
Vin(+)  
Sense(+)  
A
On/Off  
A
B
1 nF  
Share(+)  
Share(-)  
Trim  
Load  
10 μF  
Elec.  
Cap.  
Sense(-)  
Vout(-)  
B
Vin(-)  
470 nH (nom)  
Vin(+)  
On/Off  
Vout(+)  
Sense(+)  
A
B
Electrolytic  
Capacitor  
Share(+)  
Share(-)  
Trim  
10 μF  
Sense(-)  
Vout(-)  
Vin(-)  
Up to 100 Units  
470 nH (nom)  
Vin(+)  
On/Off  
Vout(+)  
Sense(+)  
A
B
Electrolytic  
Capacitor  
Share(+)  
Share(-)  
Trim  
10 μF  
Sense(-)  
Vout(-)  
Vin(-)  
Figure E: Typical Application Circuit for Paralleling of Full-Featured Units with an Input Common-Mode Choke. If an input common-mode choke is used, Vin(-)  
MUST be tied together AFTER the choke for all units. 470 nH (nominal) inductor or an output common-mode choke is required for outputs >18 V. See Figure F for  
output common-mode choke configuration.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 21  
Technical  
Specification  
IQ24xxxHZXxx  
Application Section  
Automatic Configuration: The micro-controller inside each power  
converter unit is programmed at the factory with a unique chip number.  
In every other respect, each shared unit is identical and has the same  
orderable part number.  
Resonance Between Output Capacitors is Possible: When  
multiple higher-voltage modules are paralleled, it is possible to  
excite a series resonance between the output capacitors internal to  
the module and the parasitic inductance of the module output pins.  
This is especially likely at higher output voltages where the module  
internal capacitance is relatively small. This problem is independent  
of external output capacitance. For modules with an output voltage  
greater than 18 V, to ensure that this resonant frequency is below the  
switching frequency it is recommended to add a nominal 470 nH of  
inductance, located close to the module, in series with each converter  
output. There must be at least 10 μF of capacitance per converter,  
located on the load-side of that inductor. The inductance could be from  
the leakage inductance of a secondary-side common-mode choke; in  
which case the output capacitor should be appropriately sized for the  
chosen choke. When using an output common-mode choke, the Sense  
lines must be connected on the module-side of the common-mode  
choke (see Figure F).  
RS-485 Physical Layer: The internal RS-485 transceiver includes  
many advanced protection features for enhanced reliability:  
• Current Limiting and Thermal Shutdown for  
Driver Overload Protection  
• IEC61000 ESD Protection to +/- 16.5 kV  
• Hot Plug Circuitry – SHARE(+) and SHARE(-)  
Outputs Remain Tri-State During Power-up/Power-down  
On initial startup (or after the master is disabled or shuts down),  
each unit determines the chip number of every other unit currently  
connected to the shared serial bus formed by the SHARE(+) and  
SHARE(-) pins. The unit with the highest chip number dynamically  
reconfigures itself from slave to master. The rest of the units (that do  
not have the highest chip number) become slaves.  
The master unit then broadcasts its control state over the shared serial  
bus on a cycle-by-cycle basis. The slave units interpret and implement  
the control commands sent by the master, mirroring every action of  
the master unit.  
If the master is disabled or encounters a fault condition, all units will  
immediately shut down, and if the master unit is unable to restart,  
then the unit with the next highest chip number will become master. If  
a slave unit is disabled or encounters a fault condition, all other units  
continue to run, and the slave unit can restart seamlessly.  
Automatic Interleaving: The slave units automatically lock  
frequency with the master, and interleave the phase of their switching  
transitions for improved EMI performance. To obtain the phase angle  
relative to the master, each slave divides 360 degrees by the total  
number of connected units, and multiples the result by its rank among  
chip numbers of connected units.  
Internal Schottky Diode Termination: Despite signaling at high  
speed with fast edges, external termination resistors are not necessary.  
Each receiver has four Schottky diodes built in, two for each line in the  
differential pair. These diodes clamp any ringing caused by transmission  
line reflections, preventing the voltage from going above about 5.5 V  
or below about -0.5 V. Any subsequent ringing then inherently takes  
place between 4.5 and 5.5 V or between -0.5 and 0.5 V. Since each  
receiver on the bus contains a set of clamping diodes to clamp any  
possible transmission line reflection, the bus does not necessarily need  
to be routed as a daisy-chain.  
ORing Diodes placed in series with the converter outputs must also  
have a resistor smaller than 500 Ω placed in parallel. This resistor  
keeps the output voltage of a temporarily disabled slave unit consistent  
with the active master unit. If the output voltage of the slave unit  
were allowed to totally discharge, and the slave unit tried to restart, it  
would fail because the slave reproduces the duty cycle of the master  
unit, which is running in steady state and cannot repeat an output  
voltage soft-start.  
Pins SHARE(+) and SHARE(-) are referenced to Vin(-), and therefore  
should be routed as a differential pair near the Vin(-) plane for optimal  
signal integrity. The maximum difference in voltage between Vin(-  
) pins of all units on the share-bus should be kept within 0.3 V to  
prevent steady-state conduction of the termination diodes. Therefore,  
the Vin(-) connections to each unit must be common, preferably  
connected by a single copper plane.  
Share Accuracy: Inside each converter micro-controller, the duty  
cycle is generated digitally, making for excellent duty cycle matching  
between connected units. Some small duty cycle mismatch is caused  
by (well controlled) process variations in the MOSFET gate drivers.  
However, the voltage difference induced by this duty cycle mismatch  
appears across the impedance of the entire power converter, from  
input to output, multiplied by two, since the differential current flows  
out of one converter and into another. So, a small duty cycle mismatch  
yields very small differential currents, which remain small even when  
100 units are placed in parallel.  
Common-Mode Filtering must be a single primary side choke handling  
the inputs from all the paralleled units, or multiple chokes placed on  
the secondary side. This ensurses a solid Vin(-) plane is maintained  
between units. Adding a common-mode choke at the output eliminates  
the need for the 470 nH indcutor at the output of shared units when  
Vout > 18 V. If an output common-mode choke is used, sense  
connections must be made on the module-side of the choke.  
In other current-sharing schemes, it is common to have a current-  
sharing control loop in each unit. However, due to the limited bandwidth  
of this loop, units do not necessarily share current on startup or during  
transients before this loop has a chance to respond. In contrast, the  
current-sharing scheme used in this product has no control dynamics:  
control signals are transmitted fast enough that the slave units can  
mirror the control state of the master unit on a cycle-by-cycle basis,  
and the current simply shares properly, from the first switching cycle  
to the last.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 22  
Technical  
Specification  
IQ24xxxHZXxx  
Application Section  
Vin(+)  
On/Off  
Vout(+)  
Sense(+)  
1 nF  
Share(+)  
Share(-)  
Trim  
Load  
Elec.  
Cap.  
Sense(-)  
Vout(-)  
Vin(-)  
Vin(+)  
On/Off  
Vout(+)  
Sense(+)  
Electrolytic  
Capacitor  
Share(+)  
Share(-)  
Trim  
Sense(-)  
Vout(-)  
Vin(-)  
Up to 100 Units  
Vin(+)  
On/Off  
Vout(+)  
Sense(+)  
Electrolytic  
Capacitor  
Share(+)  
Share(-)  
Trim  
Sense(-)  
Vout(-)  
Vin(-)  
Figure F: Typical Application Circuit for Paralleling of Full-Featured Units with an Output Common-Mode Choke. When using an output common-mode choke,  
SENSE lines must be connected on the module-side of the choke. See Figure E for configuration with an input common-mode choke.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 23  
Technical  
Specification  
IQ24xxxHZXxx  
Standards & Qualification Testing  
Parameter  
Notes & Conditions  
STANDARDS COMPLIANCE  
UL 60950-1/R:2011-12  
Basic Insulation  
CAN/CSA-C22.2 No. 60950-1/A1:2011  
EN 60950-1/A12:2011  
Certified by TUV  
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new  
releases or download from the SynQor website.  
Parameter  
QUALIFICATION TESTING  
Life Test  
# Units Test Conditions  
32  
5
95% rated Vin and load, units at derating point, 1000 hours  
Vibration  
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x, y, and z axis  
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
5
10  
5
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load  
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day  
5
5
Solderability  
15 pins MIL-STD-883, method 2003  
70,000 feet (21 km), see Note  
Altitude  
2
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 24  
Technical  
Specification  
IQ24xxxHZXxx  
Standard Mechanical Diagram  
2.486 .020 [63.14  
0.5]  
2.00 [50.8 ]  
1.400 [35.56 ]  
1.000 [25.4 ]  
.700 [17.78 ]  
.400 [10.16 ]  
SIDE VIEW  
+.002  
-.005  
+0.05  
.512  
.163  
[4.14 ]  
13  
[
-0.12  
]
OVERALL  
HEIGHT  
.243 .020  
[6.17 0.5]  
9
8
7
6
5
.243 .020  
[6.17 0.5]  
2.386 .020  
[60.6  
0.5]  
TOP VIEW  
1.90  
[48.3 ]  
1.90  
[48.3 ]  
.233 .020  
[5.92  
0.5]  
1
2
B
3
4
+.007  
.027  
THRU HOLE  
M3 (SEE NOTE 8)  
STANDOFFS (4)  
-.010  
+0.17  
.400 [10.16 ]  
0.69  
[
-0.25  
]
.800 [20.32 ]  
1.00 [25.4 ]  
BOTTOMSIDE CLEARANCE  
.543 .020  
[13.79 0.5]  
1.400 [35.56 ]  
NOTES  
PIN DESIGNATIONS  
Pin  
Name  
Vin(+)  
Function  
1)  
2)  
3)  
Applied torque per screw should not exceed 6in-lb. (0.7 Nm).  
1
2
B
Positive input voltage  
Baseplate flatness tolerance is 0.004” (.10 mm) TIR for surface.  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
ON/OFF  
Pins 1-4, 6-8, and B are 0.040” (1.02mm) diameter, with 0.080”  
(2.03mm) diameter standoff shoulders.  
SHARE(+)  
Active current share differential pair  
(See note 4)  
4)  
Pins 5 and 9 are 0.080” (2.03 mm) diameter with 0.125”  
(3.18 mm) diameter standoff shoulders.  
3
4
5
6
7
8
9
SHARE(-)  
Vin(–)  
Vout(–)  
SENSE(–)  
TRIM  
Negative input voltage  
Negative output voltage  
Negative remote sense (See note 1)  
Output voltage trim(See note 2)  
Positive remote sense (See note 3)  
Positive output voltage  
5)  
6)  
7)  
8)  
9)  
All Pins: Material - Copper Alloy; Finish - Matte Tin over Nickel plate  
Undimensioned components are shown for visual reference only.  
Weight: 4.9 oz (139 g)  
SENSE(+)  
Vout(+)  
Threaded and Non-Threaded options available  
All dimensions in inches (mm).  
Tolerances:  
Notes:  
1)  
SENSE(–) should be connected to Vout(–) either remotely or at the converter.  
x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
unless otherwise noted.  
2)  
3)  
Leave TRIM pin open for nominal output voltage.  
SENSE(+) should be connected to Vout(+) either remotely or at the  
converter.  
11) Workmanship: Meets or exceeds IPC-A-610C Class II  
4)  
Full-Featured option only. Pin 3 and Pin B not populated on standard model.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 25  
Technical  
Specification  
IQ24xxxHZXxx  
Flanged Mechanical Diagram  
3.15  
[80.0]  
1.400[35.56]  
1.000[25.40]  
0.700[17.78]  
0.400[10.16]  
2.950[74.93]  
0.18[4.6]  
SEE NOTES 5 & 6  
2.486±0.020  
[63.14±0.50]  
.500 ± .025  
[12.7± 0.63]  
OVERALL  
USE W/ 4-40 OR  
M3 SCREW (6x)  
RECOM. TORQUE  
3 in.lb  
HEIGHT  
6
7
8
5
9
.13[3.3]  
0.01 [0.2]  
1.900  
[48.26]  
BOTTOM VIEW  
TOP VIEW  
1.61  
[40.9]  
1.87  
[47.4]  
2.386± 0.020  
[60.60± 0.50]  
0.96  
[24.4]  
1
4
2
1
0.31  
[7.9]  
0.027±0.020  
[0.69±0.50]  
0.400[10.16]  
1.400[35.56]  
0.125  
[3.18]  
0.543±0.020 [13.79±0.50]  
0.775±0.020 [19.69±0.50]  
0.875±0.020 [22.23±0.50]  
NOTES  
PIN DESIGNATIONS  
Pin  
1
Name  
Vin(+)  
Function  
1)  
Applied torque per screw should not exceed 5in-lb. (0.7 Nm)  
Positive input voltage  
(3in-lb. recommended).  
2)  
3)  
Baseplate flatness tolerance is 0.01” (.25 mm) TIR for surface.  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
2
ON/OFF  
Pins 1-4, 6-8 and B are 0.040” (1.02mm) diameter, with 0.080”  
(2.03mm) diameter standoff shoulders.  
B
SHARE(+)  
Active current share differential pair  
(See note 4)  
4)  
Pins 5 and 9 are 0.080” (2.03 mm) diameter with 0.125”  
(3.18 mm) diameter standoff shoulders.  
3
4
5
6
7
8
9
SHARE(-)  
Vin(–)  
Vout(–)  
SENSE(–)  
TRIM  
Negative input voltage  
Negative output voltage  
Negative remote sense (See note 1)  
Output voltage trim(See note 2)  
Positive remote sense (See note 3)  
Positive output voltage  
5)  
6)  
7)  
9)  
All Pins: Material - Copper Alloy; Finish - Matte Tin over Nickel plate  
Undimensioned components are shown for visual reference only.  
Weight: 4.8oz (137g)  
SENSE(+)  
Vout(+)  
All dimensions in inches (mm).  
Tolerances:  
Notes:  
1)  
x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
unless otherwise noted.  
SENSE(–) should be connected to Vout(–) either remotely or at the converter.  
2)  
3)  
Leave TRIM pin open for nominal output voltage.  
10) Workmanship: Meets or exceeds IPC-A-610C Class II  
SENSE(+) should be connected to Vout(+) either remotely or at the  
converter.  
4)  
Full-Featured option only. Pin 3 and Pin B not populated on standard model.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 26  
Technical  
Specification  
IQ24xxxHZXxx  
PART NUMBERING SYSTEM  
ORDERING INFORMATION  
The part numbering system for SynQor’s dc-dc converters follows the format  
shown in the example below.  
The tables below show the valid model numbers and ordering options for  
converters in this product family. When ordering SynQor converters, please  
ensure that you use the complete 15 character part number consisting of  
the 12 character base part number and the additional characters for options.  
Add “-G” to the model number for 6/6 RoHS compliance.  
IQ 24 050 H Z C 60 N R A - G  
Input  
Voltage  
Output  
Voltage  
Max Output  
Current  
Model Number  
6/6 RoHS  
IQ24050HZw60xyz  
IQ24120HZw42xyz  
IQ24150HZw34xyz  
IQ24240HZw21xyz  
IQ24280HZw18xyz  
IQ24400HZw13xyz  
IQ24500HZw10xyz  
18-36  
18-36  
18-36  
18-36  
18-36  
18-36  
18-36  
5.0 V  
12 V  
15 V  
24 V  
28 V  
40 V  
50 V  
60 A  
42 A  
34 A  
21 A  
18 A  
12.5 A  
10 A  
Options (see  
Ordering Information)  
Output Current  
Thermal Design  
Performance Level  
Package Size  
Output Voltage  
Input Voltage  
Product Family  
The following options must be included in place of the w x y z spaces in the  
model numbers listed above.  
The first 12 characters comprise the base part number and the last 3  
characters indicate available options. The “-G” suffix indicates 6/6 RoHS  
compliance.  
Options Description  
Enable  
Thermal Design  
Pin Style  
Feature Set  
Logic  
C - Encased  
A - Standard w/ Auto-  
Recovery OVP  
N - Negative R - 0.180" F - Full-Feature  
S - Standard w/  
D - Encased with Non-Threaded  
Baseplate  
V - Encased with Flanged  
Baseplate  
Application Notes  
A variety of application notes and technical white papers can be downloaded  
in pdf format from our website.  
Latching OVP  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium, Hexavalent  
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated  
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor  
product is 6/6 RoHS compliant. For more information please refer to  
Not all combinations make valid part numbers, please contact SynQor for  
availability. See the Product Summary web page for more options.  
SynQor’s RoHS addendum available at our RoHS Compliance / Lead  
Free Initiative web page or e-mail us at rohs@synqor.com  
.
PATENTS  
SynQor holds the following U.S. patents, one or more of which apply to  
each product listed in this document. Additional patent applications may  
be pending or filed in the future.  
5,999,417  
6,894,468  
7,119,524  
7,765,687  
6,222,742  
6,896,526  
7,269,034  
7,787,261  
6,545,890  
6,927,987  
7,272,021  
8,023,290  
6,577,109  
7,050,309  
7,272,023  
8,149,597  
6,594,159  
7,072,190  
7,558,083  
8,493,751  
6,731,520  
7,085,146  
7,564,702  
Contact SynQor for further information and to order:  
Phone:  
978-849-0600  
Toll Free: 888-567-9596  
Warranty  
Fax:  
978-849-0602  
power@synqor.com  
www.synqor.com  
SynQor offers a two (2) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from  
SynQor.  
E-mail:  
Web:  
Address: 155 Swanson Road  
Boxborough, MA 01719  
USA  
Information furnished by SynQor is believed to be accurate and reliable.  
However, no responsibility is assumed by SynQor for its use, nor for any  
infringements of patents or other rights of third parties which may result  
from its use. No license is granted by implication or otherwise under any  
patent or patent rights of SynQor.  
Product # IQ24xxxHZXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005664 Rev. D  
11/18/13  
Page 27  

相关型号:

IQ24050HZV60NRF-G

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-10
SYNQOR

IQ24050HZV60NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8
SYNQOR

IQ24050QTC24NRS

Quarter-brick DC-DC Converter
SYNQOR

IQ24050QTC24NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 120W, Hybrid, ROHS COMPLIANT PACKAGE-8
SYNQOR

IQ24050SKC05NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 25W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR

IQ24050SMC10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR

IQ2405S

DC/DC CONVERTER +/-5V 1W
XPPOWER

IQ2405SA

1 Watt
XPPOWER

IQ24070QTC17NRS

Quarter-brick DC-DC Converter
SYNQOR

IQ24070SKC04NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 24.5W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR

IQ24070SKV04NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 24.5W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR

IQ24070SMC07NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 49W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR