IQ12xxxQGXxxx
9-22V
Cont. Input
25V
Transient Input
1.8-48 V 75 W
2250 V dc
Quarter-brick
DC-DC Converter
Outputs
Max Power
Isolation
The InQor quarter-brick converter series is composed
of next-generation, board-mountable, isolated, fixed
switching frequency dc-dc converters that use synchronous
rectification to achieve extremely high power conversion
efficiency. Each module is supplied completely encased to
provide protection from the harsh environments seen in
many industrial and transportation applications.
G
A
-
0
S
3
R
@
N
0
3
V
8
.
1
C
G
Q
8
V
T
1
x
U
0
O
2
1
x
Q
I
N
I
x
x
-
x
Operational Features
• High efficiency, 90% at full rated load current
• Delivers full power with minimal derating - no heatsink required
• Operating input voltage range: 9-22V
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
Protection Features
Mechanical Features
ut under-voltage lockout
put current limit and short circuit protection
ve back bias limit
• Industry standard Quarter-brick pin-out configuration
• Size: 2.386" x 1.536" x 0.500" (60.60 x 39.01 x 12.70 mm)
• Total weight: 3.0 oz (85 g)
put over-voltage protection
rmal shutdown
Control Features
CONTENTS
• On/Off control referenced to input side
• Remote sense for the output voltage
• Output voltage trim range of -20%, +10%
Page No.
Family Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electrical Characteristics (1.8 Vout) & Figures . . . . . . . . . . . . . . . . . . . 4
Electrical Characteristics (3.3 Vout) & Figures . . . . . . . . . . . . . . . . . . . 6
Electrical Characteristics (5.0 Vout) & Figures . . . . . . . . . . . . . . . . . . . 8
Electrical Characteristics (7.0 Vout) & Figures. . . . . . . . . . . . . . . . . . . .10
Electrical Characteristics (12 Vout) & Figures . . . . . . . . . . . . . . . . . . . .12
Electrical Characteristics (15 Vout) & Figures . . . . . . . . . . . . . . . . . . . .14
Electrical Characteristics (24 Vout) & Figures . . . . . . . . . . . . . . . . . . . .16
Electrical Characteristics (30 Vout) & Figures . . . . . . . . . . . . . . . . . . . .18
Electrical Characteristics (48 Vout) & Figures . . . . . . . . . . . . . . . . . . . .20
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Standard Mechanical Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Safety Features
• UL 60950-1:2007 Basic Insulation
• CAN/CSA-C22.2 No. 60950-1:2007
• EN60950-1/A12:2011
• RoHS compliant (see last page)
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 1
Technical
Specification
IQ12xxxQGXxxx
IQ12 FAMILY ELECTRICAL CHARACTERISTICS (all output voltages)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
ABSOLUTE MAXIMUM RATINGS
Min.
Typ.
Max. Units Notes & Conditions
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage
-0.5
30
22
25
V
V
V
Continuous
Continuous
100 ms
Basic insulation
Input to Output
Input to Base-Plate
Output to Base-Plate
2250
2250
2250
100
125
18
V dc
V dc
V dc
°C
°C
V
Operating Temperature
Storage Temperature
-40
-55
-2
Baseplate temperature
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Recommended External Input Capacitance
Input Filter Component Values (L\C)
DYNAMIC CHARACTERISTICS
Turn-On Transient
9
12
22
V
25V transient for 1ms; see Note 1
9.2
8.3
9.5
8.6
0.9
470
15\1.1
9.8
8.9
V
V
V
µF
Typical ESR 0.1-0.2 Ω
µH\µF Internal values; see Figure E
Turn-On Time
Start-Up Inhibit Time
9
230
0
ms
ms
%
Full load, Vout=90% nom.
-40 °C to +125 °C; Figure F
Maximum Output Capacitance
200
250
Output Voltage Overshoot
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance (input to output)
TEMPERATURE LIMITS
See Absolute Maximum Ratings
30
1000
MΩ
pF
FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
125
125
125
100
°C
°C
°C
°C
Package rated to 150 °C
UL rated max operating temp 130 °C
See Common Figure 3 for derating curve
Transformer Temperature
Maximum Baseplate Temperature, Tb
FEATURE CHARACTERISTICS
Switching Frequency
230
250
270
kHz
V
Regulation and Isolation stages
ON/OFF Control
Off-State Voltage
On-State Voltage
2.4
-2
1.8
0.8
ON/OFF Control
Application notes Figures A & B
Average PCB Temperature
Pull-Up Voltage
Pull-Up Resistance
5
50
125
10
V
kΩ
°C
°C
Over-Temperature Shutdown OTP Trip Point
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia) TR-NWT-000332
Calculated MTBF (MIL-217) MIL-HDBK-217F
Field Demonstrated MTBF
6
6
6
1.49
1.31
10 Hrs. Tb = 70°C
10 Hrs. Tb = 70°C
10 Hrs. See our website for details
Note 1: Higher values of isolation capacitance can be added external to the module.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 2
Technical
Specification
IQ12xxxQGXxxx
Family Figures (all output voltages)
120
100
80
60
40
20
0
Nominal Vout
Typical Current Limit Inception Point
Typical Output Voltage at Shutdown
Vin min
Vin nom
Vin max
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Load Current (%)
Common Figure 1: Startup Waveform (typical), input voltage pre-applied, ON/
Common Figure 2: Output I-V Characteristics (output voltage vs. load current)
OFF Pin on Ch 2.
showing typical current limit curves and converter shutdown points.
Common Figure 3: Trim-Up Graph for 5.0 to 15V outputs.
Common Figure 3: Trim-Up Graph for 24 to 50V outputs.
Common Figure 5: Trim-Down Graph for all outputs.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 3
Input:9-22V
Output:1.8V
Current:30A
Part No.:IQ12018QGx30
Technical Specification
IQ12018QGx30 ELECTRICAL CHARACTERISTICS (1.8 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
9.8
600
4
A
mA
mA
V
Vin min; trim up; in current limit
314
2
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
0.2
168
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
1.782
1.800
1.818
V
±0.1
±0.1
±0.3
±0.3
27
%
%
mV
V
Over Load
Over Temperature
-27
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
1.755
1.845
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
82
14
160
25
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
30
Subject to thermal derating
Output voltage 10% Low
33.0
36.0
0.9
0.3
15
39.0
A
V
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
50
mA
µF
10,000
90
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
200
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
82
83
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 4
Input:9-22V
Output:1.8V
Current:30A
Part No.:IQ12018QGx30
Technical Specification
90
85
80
75
70
65
60
16
14
12
10
8
6
9 Vin
4
9 Vin
12 Vin
22 Vin
12 Vin
22 Vin
2
0
0
5
10
15
20
25
30
0
10
20
30
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
35
30
25
20
15
35
30
25
20
15
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
10
10
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
200 LFM (1.0 m/s)
5
5
100 LFM (0.5 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.2A/µs). Load cap: 1µF ceramic cap and 15µF
tantalum cap. Ch 1: Vout (200mV/div), Ch 2: Iout (10A/div).
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:
Vin (10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 5
Input:9-22V
Output:3.3V
Current:20A
Part No.:IQ12033QGx20
Technical Specification
IQ12033QGx20 ELECTRICAL CHARACTERISTICS (3.3 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
12.6
700
3
A
mA
mA
V
Vin min; trim up; in current limit
380
1.6
0.4
250
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
3.267
3.300
3.333
V
±0.1
±0.1
±0.3
±0.3
50
%
%
mV
V
Over Load
Over Temperature
-50
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
3.217
3.383
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
58
11
115
20
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
20
Subject to thermal derating
Output voltage 10% Low
22
24
1.7
0.6
15
26
A
V
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
10,000
225
200
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range; % of nominal Vout
100% Load
86
87
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 6
Input:9-22V
Output:3.3V
Current:20A
Part No.:IQ12033QGx20
Technical Specification
95
90
85
80
75
70
65
60
14
12
10
8
6
4
9 Vin
9 Vin
12 Vin
22 Vin
12 Vin
22 Vin
2
0
0
10
Load Current (A)
20
0
10
Load Current (A)
20
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
25
20
15
10
25
20
15
10
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
5
5
200 LFM (1.0 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.2A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (10A/div).
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:
Vin (10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 7
Input:9-22V
Output:5V
Current:15A
Part No.:IQ12050QGx15
Technical Specification
IQ12050QGx15 ELECTRICAL CHARACTERISTICS (5.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
12.5
700
3.0
A
mA
mA
V
Vin min; trim up; in current limit
380
1.6
0.5
245
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
4.950
5.000
5.050
V
±0.1
±0.1
±0.3
±0.3
75
%
%
mV
V
Over Load
Over Temperature
-75
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
4.875
5.125
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
36
8
70
15
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
15
Subject to thermal derating
Output voltage 10% Low
16.5
18.0
2.3
0.8
15
19.5
A
V
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
1,000
200
200
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
88
88
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 8
Input:9-22V
Output:5V
Current:15A
Part No.:IQ12050QGx15
Technical Specification
95
90
85
80
75
70
65
60
14
12
10
8
6
9 Vin
4
9 Vin
12 Vin
20 Vin
12 Vin
20 Vin
2
0
0
2
4
6
8
10
12
14
0
2
4
6
8
10
12
14
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
20
15
20
15
10
10
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
5
5
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (5A/div).
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:
Vin (10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 9
Input:9-22V
Output:7V
Current:10A
Part No.:IQ12070QGx10
Technical Specification
IQ12070QGx10 ELECTRICAL CHARACTERISTICS (7.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
12.0
360
3
A
mA
mA
V
Vin min; trim up; in current limit
290
1.7
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
0.4
300
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
6.930
7.000
7.070
V
±0.1
±0.1
±0.3
±0.3
105
%
%
mV
V
Over Load
Over Temperature
-105
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
6.825
7.175
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
25
5
50
10
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
10
Subject to thermal derating
Output voltage 10% Low
11.0
12.0
5
13.0
A
V
0.5
15
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
4,000
350
50
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
90
90
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 10
Input:9-22V
Output:7V
Current:10A
Part No.:IQ12070QGx10
Technical Specification
95
90
85
80
75
70
65
10
8
6
4
9 Vin
9 Vin
2
12 Vin
22Vin
12 Vin
22Vin
0
0
1
3
4
6
7
8
10
0
1
3
4
6
7
8
10
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
12
10
8
12
10
8
6
6
4
4
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
200 LFM (1.0 m/s)
2
2
100 LFM (0.5 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout (200mV/div), Ch 2: Iout (5A/div).
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:
Vin (10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 11
Input:9-22V
Output:12V
Current:6A
Part No.:IQ12120QGx06
Technical Specification
IQ12120QGx06 ELECTRICAL CHARACTERISTICS (12.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
10.6
460
3.0
A
mA
mA
V
Vin min; trim up; in current limit
370
2
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
0.45
215
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
11.88
12.00
12.12
V
±0.1
±0.1
±0.3
±0.3
180
%
%
mV
V
Over Load
Over Temperature
-180
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
11.70
12.30
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
25
5
50
10
6
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
Subject to thermal derating
Output voltage 10% Low
6.6
7.2
10
7.8
A
V
0.45
15
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
1,500
450
50
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
91
89
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 12
Input:9-22V
Output:12V
Current:6A
Part No.:IQ12120QGx06
Technical Specification
10
8
95
90
85
80
75
70
65
60
6
4
9 Vin
9 Vin
2
12 Vin
22 Vin
12 Vin
22 Vin
0
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
8
6
8
6
4
4
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
2
2
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout (1V/div), Ch 2: Iout (2.5A/div).
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:
Vin (10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 13
Input:9-22V
Output:15V
Current:5A
Part No.:IQ12150QGx05
Technical Specification
IQ12150QGx05 ELECTRICAL CHARACTERISTICS (15.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
12.8
410
3.0
A
mA
mA
V
Vin min; trim up; in current limit
330
2
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
0.5
280
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
14.85
15.00
15.15
V
±0.1
±0.1
±0.3
±0.3
225
%
%
mV
V
Over Load
Over Temperature
-225
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
14.62
15.38
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
30
5
60
10
5
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
Subject to thermal derating
Output voltage 10% Low
5.5
6.0
10.7
0.3
15
6.5
A
V
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
1,000
700
50
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
90
91
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 14
Input:9-22V
Output:15V
Current:5A
Part No.:IQ12150QGx05
Technical Specification
95
90
85
80
75
70
65
60
10
8
6
4
9 Vin
9 Vin
2
12 Vin
22 Vin
12 Vin
22 Vin
0
0
1
2
3
4
5
0
1
2
3
4
5
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
6
4
6
4
2
2
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF
ceramic cap. Ch 1: Vout (1V/div), Ch 2: Iout (2.5A/div).
Figure 6: Output voltage response to step-change in input voltage (250V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:
Vin (10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 15
Input:9-22V
Output:24V
Current:3A
Part No.:IQ12240QGx03
Technical Specification
IQ12240QGx03 ELECTRICAL CHARACTERISTICS (24.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
11.9
360
3.0
A
mA
mA
V
Vin min; trim up; in current limit
290
2
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
0.8
270
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
23.76
24.00
24.24
V
±0.1
±0.1
±0.3
±0.3
360
%
%
mV
V
Over Load
Over Temperature
-360
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
23.40
24.60
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
84
19
170
40
3
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
Subject to thermal derating
Output voltage 10% Low
3.3
3.6
14
3.9
A
V
0.15
15
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
400
1400
50
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
89
90
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 16
Input:9-22V
Output:24V
Current:3A
Part No.:IQ12240QGx03
Technical Specification
95
90
85
80
75
70
65
60
12
10
8
6
4
9 Vin
9 Vin
2
12 Vin
22 Vin
12 Vin
22 Vin
0
0
1
2
3
0
1
2
3
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
4
3
4
3
2
2
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
1
1
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.08A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout
(2V/div), Ch 2: Iout (2A/div).
Figure 6: Output voltage response to step-change in input voltage (250V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (1V/div), Ch 2: Vin
(10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 17
Input:9-22V
Output:30V
Current:2.4A
Part No.:IQ12300QGx2E
Technical Specification
IQ12300QGx2E ELECTRICAL CHARACTERISTICS (30.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
11.1
350
3
A
mA
mA
V
Vin min; trim up; in current limit
280
2
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
1
See Figure 6
265
mA
A
RMS
30
Fast acting external fuse recommended
29.70
30.00
30.30
V
±0.1
±0.1
±0.3
±0.3
450
%
%
mV
V
Over Load
Over Temperature
-450
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
29.25
30.75
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
64
15
130
30
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
2.4
3.1
Subject to thermal derating
Output voltage 10% Low
2.6
2.9
18
A
V
0.12
15
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
250
1600
50
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
Across Pins 8&4; Common Figures 3-5; see Note 2
Across Pins 8&4
%
117
122
127
%
Over full temp range
100% Load
89
90
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and
noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 18
Input:9-22V
Output:30V
Current:2.4A
Part No.:IQ12300QGx2E
Technical Specification
95
90
85
80
75
70
65
60
14
12
10
8
6
4
9 Vin
9 Vin
12 Vin
22 Vin
12 Vin
22 Vin
2
0
0
1
2
0
1
2
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
3
2
3
2
1
1
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.05A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout
(2V/div), Ch 2: Iout (1A/div).
Figure 6: Output voltage response to step-change in input voltage (250V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (1V/div), Ch 2: Vin
(10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 19
Input:9-22V
Output:48V
Current:1.5A
Part No.:IQ12480QGx1F
Technical Specification
IQ12480QGx1F ELECTRICAL CHARACTERISTICS (48.0 Vout)
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature
with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
INPUT CHARACTERISTICS
Maximum Input Current
No-Load Input Current
11.9
330
3
A
mA
mA
V
Vin min; trim up; in current limit
260
2
Disabled Input Current
Response to Input Transient
Input Terminal Ripple Current
Recommended Input Fuse
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
1.1
300
See Figure 6
mA
A
RMS
30
Fast acting external fuse recommended
47.52
48.00
48.48
V
±0.1
±0.1
±0.3
±0.3
720
%
%
mV
V
Over Load
Over Temperature
-720
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
46.80
49.20
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 1
Full load
80
20
160
40
mV
mV
A
RMS
Full load
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
0
1.5
Subject to thermal derating
Output voltage 10% Low
1.65
1.80
30
1.95
A
V
0.06
15
A
Negative current drawn from output
Negative current drawn from output
Vout nominal at full load (resistive load)
0
50
mA
µF
100
2000
70
mV
µs
%
50% to 75% to 50% Iout max
To within 1% Vout nom
Across Pins 8&4; Common Figures 3-5
Across Pins 8&4
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
EFFICIENCY
-20
10
10
%
117
122
127
%
Over full temp range
100% Load
89
90
%
%
See Figure 1 for efficiency curve
See Figure 1 for efficiency curve
50% Load
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications
support (e-mail: support@synqor.com)
Note 2: Trim-up range is limited below 10% at low line and full load.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 20
Input:9-22V
Output:48V
Current:1.5A
Part No.:IQ12480QGx1F
Technical Specification
95
90
85
80
75
70
65
60
12
10
8
6
4
9 Vin
9 Vin
2
12 Vin
22 Vin
12 Vin
22 Vin
0
0
1
0
1
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
2
2
1
1
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
0
25
40
55
70
85
0
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air
flows across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (66%-100%-
66% of Iout(max); dI/dt = 0.02A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout
(2V/div), Ch 2: Iout (1A/div).
Figure 6: Output voltage response to step-change in input voltage (250V/ms).
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (1V/div), Ch 2: Vin
(10V/div).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 21
Technical
Specification
IQ12xxxQGXxxx
Application Section
BASIC OPERATION AND FEATURES
CONTROL FEATURES
This converter series uses a two-stage power conversion
topology. The first stage is a buck-converter that keeps the
output voltage constant over variations in line, load, and
temperature. The second stage uses a transformer to provide
the functions of input/output isolation and voltage step-up or
step-down to achieve the output voltage required.
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits
the user to control when the converter is on or off. This input
is referenced to the return terminal of the input bus, Vin(-).
The ON/OFF signal is active low (meaning that a low turns the
converter on). Figure A details four possible circuits for driving
the ON/OFF pin. Figure B is a detailed look of the internal ON/
OFF circuitry.
Both the first stage and the second stage switch at a fixed
frequency for predictable EMI performance. Rectification of
the transformer’s output is accomplished with synchronous
rectifiers. These devices, which are MOSFETs with a very low
on-state resistance, dissipate far less energy than Schottky
diodes. This is the primary reason that the converter has such
high efficiency, even at very low output voltages and very high
output currents.
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’s output pins to the load.
Pin 7 should be connected to Vout(+) and Pin 5 should be
connected to Vout(-) at the point on the board where regulation
is desired. A remote connection at the load can adjust for a
voltage drop only as large as that specified in this datasheet,
that is
These converters are offered totally encased to withstand harsh
environments and thermally demanding applications. Dissipation
throughout the converter is so low that it does not require a
heatsink for operation in many applications; however, adding
a heatsink provides improved thermal derating performance in
extreme situations.
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
Sense Range % x Vout
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
This series of converters use the industry standard footprint and
pin-out configuration.
Note: the output over-voltage protection circuit senses the
voltage across the output (pins 8 and 4) to determine when
it should trigger, not the voltage across the converter’s sense
leads (pins 7 and 5). Therefore, the resistive drop on the board
should be small enough so that output OVP does not trigger,
even during load transients.
ON/OFF
ON/OFF
Vin(_)
Vin(_)
Remote Enable Circuit
5V
Negative Logic
(Permanently Enabled)
5V
ON/OFF
50k
TTL/
CMOS
ON/OFF
Vin(_)
50k
ON/OFF
Vin(-)
TTL
Vin(_)
100pF
Open Collector Enable Circuit
Direct Logic Drive
Figure A: Various circuits for driving the ON/OFF pin.
Figure B: Internal ON/OFF pin circuitry
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 22
Technical
Specification
IQ12xxxQGXxxx
Application Section
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications.
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in
the application note titled “Input System Instability” on our
website. The lockout circuitry is a comparator with dc hysteresis.
When the input voltage is rising, it must exceed the typical Turn-
On Voltage Threshold value (listed on the specifications page)
before the converter will turn on. Once the converter is on,
the input voltage must fall below the typical Turn-Off Voltage
Threshold value before the converter will turn off.
To decrease the output voltage, the user should connect a
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired
decrease of the nominal output voltage, the value of the resistor
should be
511
R
=
- 10.22 (kW)
trim-down
(D%)
where
Vnominal – Vdesired
Vnominal
Output Current Limit: The maximum current limit remains
constant as the output voltage drops. However, once the
impedance of the load across the output is small enough to make
the output voltage drop below the specified Output DC Current-
Limit Shutdown Voltage, the converter turns off.
=
x 100%
D%
To increase the output voltage, the user should connect a
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired
increase of the nominal output voltage, the value of the resistor
should be
The converter then enters a “hiccup mode” where it repeatedly
turns on and off at a 5 Hz (nominal) frequency with a 5% duty
cycle until the short circuit condition is removed. This prevents
excessive heating of the converter or the load board.
5.11VOUT (100+D%)
x
511
_
R
_
=
(kW)
trim-up
10.22
)
(
1.225D%
D%
Output Over-Voltage Limit: If the voltage across the output
pins exceeds the Output Over-Voltage Protection threshold, the
converter will immediately stop switching. This prevents damage
to the load circuit due to 1) excessive series resistance in output
current path from converter output pins to sense point, 2) a
release of a short-circuit condition, or 3) a release of a current
limit condition. Load capacitance determines exactly how high
the output voltage will rise in response to these conditions. After
200 ms the converter will automatically restart.
where
V
= Nominal Output Voltage
out
Trim graphs show the relationship between the trim resistor
value and Rtrim-up and Rtrim-down, showing the total range the
output voltage can be trimmed up or down.
Note: the TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
Over-Temperature Shutdown: A temperature sensor on
the converter senses the average temperature of the module.
The thermal shutdown circuit is designed to turn the converter
off when the temperature at the sensed location reaches the
Over-Temperature Shutdown value. It will allow the converter
to turn on again when the temperature of the sensed location
falls by the amount of the Over-Temperature Shutdown Restart
Hysteresis value.
It is not necessary for the user to add capacitance at the
Trim pin. The node is internally bypassed to eliminate noise.
Total DC Variation of VOUT: For the converter to meet its
full specifications, the maximum variation of the dc value of
VOUT, due to both trimming and remote load voltage drops,
should not be greater than that specified for the output
voltage trim range.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 23
Technical
Specification
IQ12xxxQGXxxx
Application Section
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because Application Circuits: Figure C provides a typical circuit diagram
any dc-dc converter appears incrementally as a negative which details the input filtering and voltage trimming.
resistance load. A detailed application note titled “Input System
Instability” is available on the SynQor website which provides
an understanding of why this instability arises, and shows the
preferred solution for correcting it.
Vout(+)
Vin(+)
Electrolytic
Capacitor
Vsense(+)
External
Input
Filter
Rtrim-up
Vin
Trim
or
ON/OFF
Vin(_)
Cload
Rtrim-down
Iload
Vsense(_)
Vout(_)
Figure C: Typical application circuit (negative logic unit, permanently enabled).
Input Filtering and External Capacitance: Figure D provides The recommended external input capacitance is specified in the
a diagram showing the internal input filter components. This filter Input Characteristics section on the Electrical Characteristics
dramatically reduces input terminal ripple current, which otherwise page. More detailed information is available in the application note
could exceed the rating of an external electrolytic input capacitor. titled “EMI Characteristics” on the SynQor website.
L
Vin(+)
C
Vin(_)
Figure D: Internal Input Filter Diagram (component values listed on the specifications page).
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 24
Technical
Specification
IQ12xxxQGXxxx
Application Section
Startup Inhibit Period: The Startup Inhibit Period ensures that When the ON/OFF pin goes high after t2, the Startup Inhibit
the converter will remain off for approximately 200 ms when it is Period has elapsed, and the output turns on within the typical
shut down for any reason. When an output short is present, this Turn-On Time.
generates a 5 Hz “hiccup mode,” which prevents the converter
from overheating. In all, there are seven ways that the converter
can be shut down, initiating a Startup Inhibit Period:
Thermal Considerations: The maximum operating base-plate
temperature, TB, is 100 ºC. As long as the user’s thermal system
keeps TB < 100 ºC, the converter can deliver its full rated power.
•ꢀ InputꢀUnder-VoltageꢀLockout
•ꢀ InputꢀOver-VoltageꢀLockout
•ꢀ OutputꢀOver-VoltageꢀProtection
•ꢀ OverꢀTemperatureꢀShutdown
•ꢀ CurrentꢀLimit
A power derating curve can be calculated for any heatsink that is
attached to the base-plate of the converter. It is only necessary
to determine the thermal resistance, RTHBA, of the chosen heatsink
between the base-plate and the ambient air for a given airflow
rate. This information is usually available from the heatsink
vendor. The following formula can the be used to determine the
maximum power the converter can dissipate for a given thermal
condition if its base-plate is to be no higher than 100 ºC.
•ꢀ ShortꢀCircuitꢀProtection
•ꢀ TurnedꢀoffꢀbyꢀtheꢀON/OFFꢀinput
Figure E shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
100 ºC - TA
Pmax
=
diss
RTH
BA
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout feature.
When the input voltage rises above the UVL threshold, the Input
Under-Voltage Lockout is released, and a Startup Inhibit Period is
initiated. At the end of this delay, the ON/OFF pin is evaluated,
and since it is active, the unit turns on.
This value of power dissipation can then be used in conjunction
with the data shown in Figure 2 to determine the maximum load
current (and power) that the converter can deliver in the given
thermal condition.
For convenience, power derating curves for an encased converter
without a heatsink and with a typical heatsink are provided for
each output voltage.
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
V
in
Under-Voltage
Lockout Turn-
On Threshold
ON/OFF
(neg logic)
ON
OFF
ON
OFF
ON
9ms
(typical turn on time)
V
out
230ms
(typical start-up
inhibit period)
200ms
200ms
t
t0
t1
t2
Figure E: Startup Inhibit Period (turn-on time not to scale)
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 25
Technical
Specification
IQ12xxxQGXxxx
Standards & Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1:2007
Basic Insulation
CAN/CSA-C22.2 No. 60950-1:2007
EN60950-1/A12:2011
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
# Units Test Conditions
32
5
95% rated Vin and load, units at derating point, 1000 hours
Vibration
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x, y, and z axis
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
5
10
5
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day
5
5
Solderability
15 pins MIL-STD-883, method 2003
70,000 feet (21 km), see Note
Altitude
2
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 26
Technical
Specification
IQ12xxxQGXxxx
Standard Mechanical Diagram
Top View
1.536 ±0.020 (39.01 ±0.5)
Side View
1. 030 (26.16)
0.600 (15.24)
0.450 (11.43)
0.300 (7.62)
0.150 (3.81)
0.253±0.020
(6.4±0.5)
0.18±0.010
(4.57±0.25)
0.263±0.020
(6.68±0.5)
8 7 6 5 4
2.386
± 0.020
(60.6± 0.5)
2.00
(50.8)
1.86
(47.2)
M3 Threaded Inserts
4 Places
See Notes
1
3
2
0.183±.020 (4.65)±0.5
0.500±0.025
(12.7±0.63)
Overall Height
0.468±0.020 (11.89±0.5)
0.300 (7.62)
0.600 (15.24)
NOTES
PIN DESIGNATIONS
1)
M3 screws used to bolt unit’s baseplate to other surfaces (such as
a heatsink) must not exceed 0.100" (2.54 mm) depth below the
surface of the baseplate.
Pin Name Function
1
Vin(+) Positive input voltage
2)
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
Applied torque per screw should not exceed 6in-lb. (0.7 Nm).
2
ON/OFF
Vin(–)
3)
4)
Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface.
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
3
Negative input voltage
4
Vout(–) Negative output voltage
5)
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
1
5
SENSE(–) Negative remote sense
2
6
TRIM
Output voltage trim
6)
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over
Nickel plate
3
7
8
SENSE(+) Positive remote sense
Vout(+) Positive output voltage
7)
Weight: 3.02 oz. (85.7 g) typical
8)
All dimensions in inches (mm)
Notes:
1)
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
SENSE(–) should be connected to Vout(–) either remotely
or at the converter.
9)
Workmanship: Meets or exceeds IPC-A-610 Class II
2)
3)
Leave TRIM pin open for nominal output voltage.
10)
Recommended pin length is 0.03” (0.76mm) greater than the PCB
thickness.
SENSE(+) should be connected to Vout(+) either remotely
or at the converter.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 27
Technical
Specification
IQ12xxxQGXxxx
Flanged Mechanical Diagram
.01 [0.2]
OVERALL HEIGHT
.500 ±.025
[12.7 ±0.63]
.60 [ 15.2
.45 [ 11.4
]
]
2.200 ±.020 [ 55.88 ±0.5]
1.536 ±.020 [ 39.01 ±0.5]
.30 [ 7.6
.15 [ 3.8
]
.18
[ 4.6
SEE NOTE 5
]
]
R .065
4
5
6
7
8
[ 1.65 ]
2.00
[ 50.8
TOP VIEW
BOTTOM VIEW
]
2.07
[ 52.5]
2.386 ±.020
[ 60.6 ±0.5]
1.66
[ 42.2
]
1.01 [25.7]
.36 [9.1]
3
2
1
1
.70
[ 17.8
.183 ±.020
[ 4.65±0.5]
1.30
[ 33]
.30 [ 7.6
]
]
.13
[ 3.2
BOTTOMSIDE CLEARANCE
.010 ±.020
]
.800 ±.020
[ 20.32 ±0.5]
.60 [ 15.2
]
.02 [ 0.6
]
[0.51
0.25]
NOTES
PIN DESIGNATIONS
1)
Applied torque per screw should not exceed 5in-lb.
(3in-lb recommended).
Baseplate flatness tolerance is 0.01” (.2mm) TIR for surface.
Pin Name Function
1
Vin(+) Positive input voltage
2)
3)
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
2
ON/OFF
Vin(–)
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
3
Negative input voltage
4)
5)
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
All Pins: Material - Copper Alloy, Finish (RoHS 6/6) - Matte Tin over
Nickel plate
4
Vout(–) Negative output voltage
1
5
SENSE(–) Negative remote sense
2
6
TRIM
Output voltage trim
6)
7)
Total Weight: 3.12 oz (88.5 g)
All dimensions in inches (mm)
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
3
7
8
SENSE(+) Positive remote sense
Vout(+) Positive output voltage
Notes:
1)
SENSE(–) should be connected to Vout(–) either remotely
or at the converter.
8)
9)
Workmanship: Meets or exceeds IPC-A-610 Class II
Recommended pin length is 0.03” (0.76mm) greater than the PCB
thickness.
A thermal interface material is required to assure proper heat transfer
from the flanged baseplate to the cooling surface. Thermal grease
may be used, or materials such as Thermalloy’s Grafoil or Bergquist
HiFlow and Softflow. Other similar products are available from many
heatsink manufacturers.
2)
3)
Leave TRIM pin open for nominal output voltage.
10)
SENSE(+) should be connected to Vout(+) either remotely
or at the converter.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 28
Technical
Specification
IQ12xxxQGXxxx
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s dc-dc converters follows the format
shown in the example below.
The tables below show the valid model numbers and ordering options for
converters in this product family. When ordering SynQor converters, please
ensure that you use the complete 15 character part number consisting of
the 12 character base part number and the additional characters for options.
Add “-G” to the model number for 6/6 RoHS compliance.
IQ 12 018 Q G C 30 N R S - G
Input
Voltage
Output
Voltage Output Current
Maximum
Model Number
6/6 RoHS
IQ12018QGw30xyz
IQ12033QGw20xyz
IQ12050QGw15xyz
IQ12070QGw10xyz
IQ12120QGw06xyz
IQ12150QGw05xyz
IQ12240QGw03xyz
IQ12300QGw2Exyz
IQ12480QGw1Fxyz
9-22V
9-22V
9-22V
9-22V
9-22V
9-22V
9-22V
9-22V
9-22V
1.8 V
3.3 V
5 V
30 A
20 A
15 A
10 A
6 A
Options (see
Ordering Information)
Output Current
7 V
Thermal Design
Performance Level
Package Size
12 V
15 V
24 V
30 V
48 V
5 A
3 A
2.4 A
1.5 A
Output Voltage
Input Voltage
Product Family
The following options must be included in place of the w x y z spaces in the
model numbers listed above.
The first 12 characters comprise the base part number and the last 3
characters indicate available options. The “-G” suffix indicates 6/6 RoHS
compliance.
Options Description
Thermal Design
Enable Logic Pin Style
Feature Set
w
x
y
z
C - Encased
V - Encased with
Flanged Baseplate
N - Negative
R - 0.180"
S - Standard
Application Notes
A variety of application notes and technical white papers can be downloaded
in pdf format from our website.
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium, Hexavalent
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor
product is 6/6 RoHS compliant. For more information please refer to
Not all combinations make valid part numbers, please contact SynQor for
availability.
SynQor’s RoHS addendum available at our RoHS Compliance / Lead
Free Initiative web page or e-mail us at rohs@synqor.com
.
PATENTS
SynQor holds the following U.S. patents, one or more of which apply to
each product listed in this document. Additional patent applications may
be pending or filed in the future.
5,999,417
6,894,468
6,222,742
6,896,526
6,545,890
6,927,987
6,577,109
7,050,309
6,594,159
7,072,190
7,558,083
6,731,520
7,085,146
7,564,702
7,119,524
7,765,687
7,269,034
7,787,261
7,272,021
8,023,290
7,272,023
8,149,597
Contact SynQor for further information and to order:
Phone:
978-849-0600
Toll Free: 888-567-9596
Warranty
Fax:
978-849-0602
power@synqor.com
www.synqor.com
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
E-mail:
Web:
Address: 155 Swanson Road
Boxborough, MA 01719
USA
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
Product # IQ12xxxQGXxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005176 Rev. D
04/09/13
Page 29
相关型号:
IQ12240QGV03NRS-G
DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK-8
SYNQOR
IQ12240QTC04NRS-G
DC-DC Regulated Power Supply Module, 1 Output, 96W, Hybrid, ROHS COMPLIANT PACKAGE-8
SYNQOR
IQ12300QTB03NRS-G
DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
SYNQOR
IQ12300QTC03NRS-G
DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
SYNQOR
©2020 ICPDF网 联系我们和版权申明