Technical  
Specification  
IQ12xxxQGXxxx  
9-22V  
Cont. Input  
25V  
Transient Input  
1.8-48 V 75 W  
2250 V dc  
Quarter-brick  
DC-DC Converter  
Outputs  
Max Power  
Isolation  
The InQor quarter-brick converter series is composed  
of next-generation, board-mountable, isolated, fixed  
switching frequency dc-dc converters that use synchronous  
rectification to achieve extremely high power conversion  
efficiency. Each module is supplied completely encased to  
provide protection from the harsh environments seen in  
many industrial and transportation applications.  
G
A
-
0
S
3
R
@
N
0
3
V
8
.
1
C
G
Q
8
V
T
1
x
U
0
O
2
1
x
Q
I
N
I
x
x
-
x
Operational Features  
• High efficiency, 90% at full rated load current  
• Delivers full power with minimal derating - no heatsink required  
• Operating input voltage range: 9-22V  
• Fixed frequency switching provides predictable EMI  
• No minimum load requirement  
Protection Features  
Mechanical Features  
ut under-voltage lockout  
put current limit and short circuit protection  
ve back bias limit  
• Industry standard Quarter-brick pin-out configuration  
• Size: 2.386" x 1.536" x 0.500" (60.60 x 39.01 x 12.70 mm)  
Total weight: 3.0 oz (85 g)  
put over-voltage protection  
rmal shutdown  
Control Features  
CONTENTS  
• On/Off control referenced to input side  
• Remote sense for the output voltage  
• Output voltage trim range of -20%, +10%  
Page No.  
Family Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Electrical Characteristics (1.8 Vout) & Figures . . . . . . . . . . . . . . . . . . . 4  
Electrical Characteristics (3.3 Vout) & Figures . . . . . . . . . . . . . . . . . . . 6  
Electrical Characteristics (5.0 Vout) & Figures . . . . . . . . . . . . . . . . . . . 8  
Electrical Characteristics (7.0 Vout) & Figures. . . . . . . . . . . . . . . . . . . .10  
Electrical Characteristics (12 Vout) & Figures . . . . . . . . . . . . . . . . . . . .12  
Electrical Characteristics (15 Vout) & Figures . . . . . . . . . . . . . . . . . . . .14  
Electrical Characteristics (24 Vout) & Figures . . . . . . . . . . . . . . . . . . . .16  
Electrical Characteristics (30 Vout) & Figures . . . . . . . . . . . . . . . . . . . .18  
Electrical Characteristics (48 Vout) & Figures . . . . . . . . . . . . . . . . . . . .20  
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22  
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
Standard Mechanical Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
Flanged Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
Safety Features  
• UL 60950-1:2007 Basic Insulation  
• CAN/CSA-C22.2 No. 60950-1:2007  
• EN60950-1/A12:2011  
• RoHS compliant (see last page)  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 1  
Technical  
Specification  
IQ12xxxQGXxxx  
IQ12 FAMILY ELECTRICAL CHARACTERISTICS (all output voltages)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
ABSOLUTE MAXIMUM RATINGS  
Min.  
Typ.  
Max. Units Notes & Conditions  
Input Voltage  
Non-Operating  
Operating  
Operating Transient Protection  
Isolation Voltage  
-0.5  
30  
22  
25  
V
V
V
Continuous  
Continuous  
100 ms  
Basic insulation  
Input to Output  
Input to Base-Plate  
Output to Base-Plate  
2250  
2250  
2250  
100  
125  
18  
V dc  
V dc  
V dc  
°C  
°C  
V
Operating Temperature  
Storage Temperature  
-40  
-55  
-2  
Baseplate temperature  
Voltage at ON/OFF input pin  
INPUT CHARACTERISTICS  
Operating Input Voltage Range  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Voltage Hysteresis  
Recommended External Input Capacitance  
Input Filter Component Values (L\C)  
DYNAMIC CHARACTERISTICS  
Turn-On Transient  
9
12  
22  
V
25V transient for 1ms; see Note 1  
9.2  
8.3  
9.5  
8.6  
0.9  
470  
15\1.1  
9.8  
8.9  
V
V
V
µF  
Typical ESR 0.1-0.2 Ω  
µH\µF Internal values; see Figure E  
Turn-On Time  
Start-Up Inhibit Time  
9
230  
0
ms  
ms  
%
Full load, Vout=90% nom.  
-40 °C to +125 °C; Figure F  
Maximum Output Capacitance  
200  
250  
Output Voltage Overshoot  
ISOLATION CHARACTERISTICS  
Isolation Voltage (dielectric strength)  
Isolation Resistance  
Isolation Capacitance (input to output)  
TEMPERATURE LIMITS  
See Absolute Maximum Ratings  
30  
1000  
MΩ  
pF  
FOR POWER DERATING CURVES  
Semiconductor Junction Temperature  
Board Temperature  
125  
125  
125  
100  
°C  
°C  
°C  
°C  
Package rated to 150 °C  
UL rated max operating temp 130 °C  
See Common Figure 3 for derating curve  
Transformer Temperature  
Maximum Baseplate Temperature, Tb  
FEATURE CHARACTERISTICS  
Switching Frequency  
230  
250  
270  
kHz  
V
Regulation and Isolation stages  
ON/OFF Control  
Off-State Voltage  
On-State Voltage  
2.4  
-2  
1.8  
0.8  
ON/OFF Control  
Application notes Figures A & B  
Average PCB Temperature  
Pull-Up Voltage  
Pull-Up Resistance  
5
50  
125  
10  
V
kΩ  
°C  
°C  
Over-Temperature Shutdown OTP Trip Point  
Over-Temperature Shutdown Restart Hysteresis  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (Telcordia) TR-NWT-000332  
Calculated MTBF (MIL-217) MIL-HDBK-217F  
Field Demonstrated MTBF  
6
6
6
1.49  
1.31  
10 Hrs. Tb = 70°C  
10 Hrs. Tb = 70°C  
10 Hrs. See our website for details  
Note 1: Higher values of isolation capacitance can be added external to the module.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 2  
Technical  
Specification  
IQ12xxxQGXxxx  
Family Figures (all output voltages)  
120  
100  
80  
60  
40  
20  
0
Nominal Vout  
Typical Current Limit Inception Point  
Typical Output Voltage at Shutdown  
Vin min  
Vin nom  
Vin max  
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150  
Load Current (%)  
Common Figure 1: Startup Waveform (typical), input voltage pre-applied, ON/  
Common Figure 2: Output I-V Characteristics (output voltage vs. load current)  
OFF Pin on Ch 2.  
showing typical current limit curves and converter shutdown points.  
Common Figure 3: Trim-Up Graph for 5.0 to 15V outputs.  
Common Figure 3: Trim-Up Graph for 24 to 50V outputs.  
Common Figure 5: Trim-Down Graph for all outputs.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 3  
Input:9-22V  
Output:1.8V  
Current:30A  
Part No.:IQ12018QGx30  
Technical Specification  
IQ12018QGx30 ELECTRICAL CHARACTERISTICS (1.8 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
9.8  
600  
4
A
mA  
mA  
V
Vin min; trim up; in current limit  
314  
2
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
0.2  
168  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
1.782  
1.800  
1.818  
V
±0.1  
±0.1  
±0.3  
±0.3  
27  
%
%
mV  
V
Over Load  
Over Temperature  
-27  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
1.755  
1.845  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
82  
14  
160  
25  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
30  
Subject to thermal derating  
Output voltage 10% Low  
33.0  
36.0  
0.9  
0.3  
15  
39.0  
A
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
50  
mA  
µF  
10,000  
90  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
200  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
82  
83  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 4  
Input:9-22V  
Output:1.8V  
Current:30A  
Part No.:IQ12018QGx30  
Technical Specification  
90  
85  
80  
75  
70  
65  
60  
16  
14  
12  
10  
8
6
9 Vin  
4
9 Vin  
12 Vin  
22 Vin  
12 Vin  
22 Vin  
2
0
0
5
10  
15  
20  
25  
30  
0
10  
20  
30  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
35  
30  
25  
20  
15  
35  
30  
25  
20  
15  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
10  
10  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
5
5
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.2A/µs). Load cap: 1µF ceramic cap and 15µF  
tantalum cap. Ch 1: Vout (200mV/div), Ch 2: Iout (10A/div).  
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:  
Vin (10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 5  
Input:9-22V  
Output:3.3V  
Current:20A  
Part No.:IQ12033QGx20  
Technical Specification  
IQ12033QGx20 ELECTRICAL CHARACTERISTICS (3.3 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
12.6  
700  
3
A
mA  
mA  
V
Vin min; trim up; in current limit  
380  
1.6  
0.4  
250  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
3.267  
3.300  
3.333  
V
±0.1  
±0.1  
±0.3  
±0.3  
50  
%
%
mV  
V
Over Load  
Over Temperature  
-50  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
3.217  
3.383  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
58  
11  
115  
20  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
20  
Subject to thermal derating  
Output voltage 10% Low  
22  
24  
1.7  
0.6  
15  
26  
A
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
10,000  
225  
200  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range; % of nominal Vout  
100% Load  
86  
87  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 6  
Input:9-22V  
Output:3.3V  
Current:20A  
Part No.:IQ12033QGx20  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
14  
12  
10  
8
6
4
9 Vin  
9 Vin  
12 Vin  
22 Vin  
12 Vin  
22 Vin  
2
0
0
10  
Load Current (A)  
20  
0
10  
Load Current (A)  
20  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
25  
20  
15  
10  
25  
20  
15  
10  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
5
5
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.2A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (10A/div).  
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:  
Vin (10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 7  
Input:9-22V  
Output:5V  
Current:15A  
Part No.:IQ12050QGx15  
Technical Specification  
IQ12050QGx15 ELECTRICAL CHARACTERISTICS (5.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
12.5  
700  
3.0  
A
mA  
mA  
V
Vin min; trim up; in current limit  
380  
1.6  
0.5  
245  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
4.950  
5.000  
5.050  
V
±0.1  
±0.1  
±0.3  
±0.3  
75  
%
%
mV  
V
Over Load  
Over Temperature  
-75  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
4.875  
5.125  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
36  
8
70  
15  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
15  
Subject to thermal derating  
Output voltage 10% Low  
16.5  
18.0  
2.3  
0.8  
15  
19.5  
A
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
1,000  
200  
200  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
88  
88  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 8  
Input:9-22V  
Output:5V  
Current:15A  
Part No.:IQ12050QGx15  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
14  
12  
10  
8
6
9 Vin  
4
9 Vin  
12 Vin  
20 Vin  
12 Vin  
20 Vin  
2
0
0
2
4
6
8
10  
12  
14  
0
2
4
6
8
10  
12  
14  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
20  
15  
20  
15  
10  
10  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
5
5
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout (500mV/div), Ch 2: Iout (5A/div).  
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:  
Vin (10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 9  
Input:9-22V  
Output:7V  
Current:10A  
Part No.:IQ12070QGx10  
Technical Specification  
IQ12070QGx10 ELECTRICAL CHARACTERISTICS (7.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
12.0  
360  
3
A
mA  
mA  
V
Vin min; trim up; in current limit  
290  
1.7  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
0.4  
300  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
6.930  
7.000  
7.070  
V
±0.1  
±0.1  
±0.3  
±0.3  
105  
%
%
mV  
V
Over Load  
Over Temperature  
-105  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
6.825  
7.175  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
25  
5
50  
10  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
10  
Subject to thermal derating  
Output voltage 10% Low  
11.0  
12.0  
5
13.0  
A
V
0.5  
15  
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
4,000  
350  
50  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
90  
90  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 10  
Input:9-22V  
Output:7V  
Current:10A  
Part No.:IQ12070QGx10  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
10  
8
6
4
9 Vin  
9 Vin  
2
12 Vin  
22Vin  
12 Vin  
22Vin  
0
0
1
3
4
6
7
8
10  
0
1
3
4
6
7
8
10  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
12  
10  
8
12  
10  
8
6
6
4
4
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
2
2
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout (200mV/div), Ch 2: Iout (5A/div).  
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:  
Vin (10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 11  
Input:9-22V  
Output:12V  
Current:6A  
Part No.:IQ12120QGx06  
Technical Specification  
IQ12120QGx06 ELECTRICAL CHARACTERISTICS (12.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
10.6  
460  
3.0  
A
mA  
mA  
V
Vin min; trim up; in current limit  
370  
2
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
0.45  
215  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
11.88  
12.00  
12.12  
V
±0.1  
±0.1  
±0.3  
±0.3  
180  
%
%
mV  
V
Over Load  
Over Temperature  
-180  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
11.70  
12.30  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
25  
5
50  
10  
6
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
Subject to thermal derating  
Output voltage 10% Low  
6.6  
7.2  
10  
7.8  
A
V
0.45  
15  
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
1,500  
450  
50  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
91  
89  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 12  
Input:9-22V  
Output:12V  
Current:6A  
Part No.:IQ12120QGx06  
Technical Specification  
10  
8
95  
90  
85  
80  
75  
70  
65  
60  
6
4
9 Vin  
9 Vin  
2
12 Vin  
22 Vin  
12 Vin  
22 Vin  
0
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
8
6
8
6
4
4
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
2
2
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout (1V/div), Ch 2: Iout (2.5A/div).  
Figure 6: Output voltage response to step-change in input voltage (250 V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:  
Vin (10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 13  
Input:9-22V  
Output:15V  
Current:5A  
Part No.:IQ12150QGx05  
Technical Specification  
IQ12150QGx05 ELECTRICAL CHARACTERISTICS (15.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
12.8  
410  
3.0  
A
mA  
mA  
V
Vin min; trim up; in current limit  
330  
2
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
0.5  
280  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
14.85  
15.00  
15.15  
V
±0.1  
±0.1  
±0.3  
±0.3  
225  
%
%
mV  
V
Over Load  
Over Temperature  
-225  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
14.62  
15.38  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
30  
5
60  
10  
5
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
Subject to thermal derating  
Output voltage 10% Low  
5.5  
6.0  
10.7  
0.3  
15  
6.5  
A
V
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
1,000  
700  
50  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
90  
91  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 14  
Input:9-22V  
Output:15V  
Current:5A  
Part No.:IQ12150QGx05  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
10  
8
6
4
9 Vin  
9 Vin  
2
12 Vin  
22 Vin  
12 Vin  
22 Vin  
0
0
1
2
3
4
5
0
1
2
3
4
5
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
6
4
6
4
2
2
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout (1V/div), Ch 2: Iout (2.5A/div).  
Figure 6: Output voltage response to step-change in input voltage (250V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (500mV/div), Ch 2:  
Vin (10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 15  
Input:9-22V  
Output:24V  
Current:3A  
Part No.:IQ12240QGx03  
Technical Specification  
IQ12240QGx03 ELECTRICAL CHARACTERISTICS (24.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
11.9  
360  
3.0  
A
mA  
mA  
V
Vin min; trim up; in current limit  
290  
2
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
0.8  
270  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
23.76  
24.00  
24.24  
V
±0.1  
±0.1  
±0.3  
±0.3  
360  
%
%
mV  
V
Over Load  
Over Temperature  
-360  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
23.40  
24.60  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
84  
19  
170  
40  
3
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
Subject to thermal derating  
Output voltage 10% Low  
3.3  
3.6  
14  
3.9  
A
V
0.15  
15  
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
400  
1400  
50  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
89  
90  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 16  
Input:9-22V  
Output:24V  
Current:3A  
Part No.:IQ12240QGx03  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
12  
10  
8
6
4
9 Vin  
9 Vin  
2
12 Vin  
22 Vin  
12 Vin  
22 Vin  
0
0
1
2
3
0
1
2
3
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
4
3
4
3
2
2
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
1
1
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.08A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout  
(2V/div), Ch 2: Iout (2A/div).  
Figure 6: Output voltage response to step-change in input voltage (250V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (1V/div), Ch 2: Vin  
(10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 17  
Input:9-22V  
Output:30V  
Current:2.4A  
Part No.:IQ12300QGx2E  
Technical Specification  
IQ12300QGx2E ELECTRICAL CHARACTERISTICS (30.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
11.1  
350  
3
A
mA  
mA  
V
Vin min; trim up; in current limit  
280  
2
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
1
See Figure 6  
265  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
29.70  
30.00  
30.30  
V
±0.1  
±0.1  
±0.3  
±0.3  
450  
%
%
mV  
V
Over Load  
Over Temperature  
-450  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
29.25  
30.75  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
64  
15  
130  
30  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
2.4  
3.1  
Subject to thermal derating  
Output voltage 10% Low  
2.6  
2.9  
18  
A
V
0.12  
15  
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
250  
1600  
50  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
%
117  
122  
127  
%
Over full temp range  
100% Load  
89  
90  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 18  
Input:9-22V  
Output:30V  
Current:2.4A  
Part No.:IQ12300QGx2E  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
14  
12  
10  
8
6
4
9 Vin  
9 Vin  
12 Vin  
22 Vin  
12 Vin  
22 Vin  
2
0
0
1
2
0
1
2
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
3
2
3
2
1
1
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.05A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout  
(2V/div), Ch 2: Iout (1A/div).  
Figure 6: Output voltage response to step-change in input voltage (250V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (1V/div), Ch 2: Vin  
(10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 19  
Input:9-22V  
Output:48V  
Current:1.5A  
Part No.:IQ12480QGx1F  
Technical Specification  
IQ12480QGx1F ELECTRICAL CHARACTERISTICS (48.0 Vout)  
Ta = 25 °C, airflow rate = 300 LFM, Vin = 12 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
11.9  
330  
3
A
mA  
mA  
V
Vin min; trim up; in current limit  
260  
2
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
1.1  
300  
See Figure 6  
mA  
A
RMS  
30  
Fast acting external fuse recommended  
47.52  
48.00  
48.48  
V
±0.1  
±0.1  
±0.3  
±0.3  
720  
%
%
mV  
V
Over Load  
Over Temperature  
-720  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
46.80  
49.20  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 1  
Full load  
80  
20  
160  
40  
mV  
mV  
A
RMS  
Full load  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
0
1.5  
Subject to thermal derating  
Output voltage 10% Low  
1.65  
1.80  
30  
1.95  
A
V
0.06  
15  
A
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
0
50  
mA  
µF  
100  
2000  
70  
mV  
µs  
%
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5  
Across Pins 8&4  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
-20  
10  
10  
%
117  
122  
127  
%
Over full temp range  
100% Load  
89  
90  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications  
support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 20  
Input:9-22V  
Output:48V  
Current:1.5A  
Part No.:IQ12480QGx1F  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
12  
10  
8
6
4
9 Vin  
9 Vin  
2
12 Vin  
22 Vin  
12 Vin  
22 Vin  
0
0
1
0
1
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
2
2
1
1
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
0
25  
40  
55  
70  
85  
0
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output voltage response to step-change in load current (66%-100%-  
66% of Iout(max); dI/dt = 0.02A/µs). Load cap: 1µF ceramic cap. Ch 1: Vout  
(2V/div), Ch 2: Iout (1A/div).  
Figure 6: Output voltage response to step-change in input voltage (250V/ms).  
Load cap: 100µF electrolytic output capacitance. Ch 1: Vout (1V/div), Ch 2: Vin  
(10V/div).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 21  
Technical  
Specification  
IQ12xxxQGXxxx  
Application Section  
BASIC OPERATION AND FEATURES  
CONTROL FEATURES  
This converter series uses a two-stage power conversion  
topology. The first stage is a buck-converter that keeps the  
output voltage constant over variations in line, load, and  
temperature. The second stage uses a transformer to provide  
the functions of input/output isolation and voltage step-up or  
step-down to achieve the output voltage required.  
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits  
the user to control when the converter is on or off. This input  
is referenced to the return terminal of the input bus, Vin(-).  
The ON/OFF signal is active low (meaning that a low turns the  
converter on). Figure A details four possible circuits for driving  
the ON/OFF pin. Figure B is a detailed look of the internal ON/  
OFF circuitry.  
Both the first stage and the second stage switch at a fixed  
frequency for predictable EMI performance. Rectification of  
the transformer’s output is accomplished with synchronous  
rectifiers. These devices, which are MOSFETs with a very low  
on-state resistance, dissipate far less energy than Schottky  
diodes. This is the primary reason that the converter has such  
high efficiency, even at very low output voltages and very high  
output currents.  
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs  
correct for voltage drops along the conductors that connect the  
converter’s output pins to the load.  
Pin 7 should be connected to Vout(+) and Pin 5 should be  
connected to Vout(-) at the point on the board where regulation  
is desired. A remote connection at the load can adjust for a  
voltage drop only as large as that specified in this datasheet,  
that is  
These converters are offered totally encased to withstand harsh  
environments and thermally demanding applications. Dissipation  
throughout the converter is so low that it does not require a  
heatsink for operation in many applications; however, adding  
a heatsink provides improved thermal derating performance in  
extreme situations.  
[Vout(+) - Vout(-)] [Vsense(+) - Vsense(-)] <  
Sense Range % x Vout  
Pins 7 and 5 must be connected for proper regulation of  
the output voltage. If these connections are not made, the  
converter will deliver an output voltage that is slightly higher  
than its specified value.  
This series of converters use the industry standard footprint and  
pin-out configuration.  
Note: the output over-voltage protection circuit senses the  
voltage across the output (pins 8 and 4) to determine when  
it should trigger, not the voltage across the converter’s sense  
leads (pins 7 and 5). Therefore, the resistive drop on the board  
should be small enough so that output OVP does not trigger,  
even during load transients.  
ON/OFF  
ON/OFF  
Vin(_)  
Vin(_)  
Remote Enable Circuit  
5V  
Negative Logic  
(Permanently Enabled)  
5V  
ON/OFF  
50k  
TTL/  
CMOS  
ON/OFF  
Vin(_)  
50k  
ON/OFF  
Vin(-)  
TTL  
Vin(_)  
100pF  
Open Collector Enable Circuit  
Direct Logic Drive  
Figure A: Various circuits for driving the ON/OFF pin.  
Figure B: Internal ON/OFF pin circuitry  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 22  
Technical  
Specification  
IQ12xxxQGXxxx  
Application Section  
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the  
user to adjust the output voltage across the sense leads up or  
down according to the trim range specifications.  
PROTECTION FEATURES  
Input Under-Voltage Lockout: The converter is designed  
to turn off when the input voltage is too low, helping avoid an  
input system instability problem, described in more detail in  
the application note titled “Input System Instability” on our  
website. The lockout circuitry is a comparator with dc hysteresis.  
When the input voltage is rising, it must exceed the typical Turn-  
On Voltage Threshold value (listed on the specifications page)  
before the converter will turn on. Once the converter is on,  
the input voltage must fall below the typical Turn-Off Voltage  
Threshold value before the converter will turn off.  
To decrease the output voltage, the user should connect a  
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired  
decrease of the nominal output voltage, the value of the resistor  
should be  
511  
R
=
- 10.22 (kW)  
trim-down  
(D%)  
where  
Vnominal – Vdesired  
Vnominal  
Output Current Limit: The maximum current limit remains  
constant as the output voltage drops. However, once the  
impedance of the load across the output is small enough to make  
the output voltage drop below the specified Output DC Current-  
Limit Shutdown Voltage, the converter turns off.  
=
x 100%  
D%  
To increase the output voltage, the user should connect a  
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired  
increase of the nominal output voltage, the value of the resistor  
should be  
The converter then enters a “hiccup mode” where it repeatedly  
turns on and off at a 5 Hz (nominal) frequency with a 5% duty  
cycle until the short circuit condition is removed. This prevents  
excessive heating of the converter or the load board.  
5.11VOUT (100+D%)  
x
511  
_
R
_
=
(kW)  
trim-up  
10.22  
)
(
1.225D%  
D%  
Output Over-Voltage Limit: If the voltage across the output  
pins exceeds the Output Over-Voltage Protection threshold, the  
converter will immediately stop switching. This prevents damage  
to the load circuit due to 1) excessive series resistance in output  
current path from converter output pins to sense point, 2) a  
release of a short-circuit condition, or 3) a release of a current  
limit condition. Load capacitance determines exactly how high  
the output voltage will rise in response to these conditions. After  
200 ms the converter will automatically restart.  
where  
V
= Nominal Output Voltage  
out  
Trim graphs show the relationship between the trim resistor  
value and Rtrim-up and Rtrim-down, showing the total range the  
output voltage can be trimmed up or down.  
Note: the TRIM feature does not affect the voltage at which the  
output over-voltage protection circuit is triggered. Trimming the  
output voltage too high may cause the over-voltage protection  
circuit to engage, particularly during transients.  
Over-Temperature Shutdown: A temperature sensor on  
the converter senses the average temperature of the module.  
The thermal shutdown circuit is designed to turn the converter  
off when the temperature at the sensed location reaches the  
Over-Temperature Shutdown value. It will allow the converter  
to turn on again when the temperature of the sensed location  
falls by the amount of the Over-Temperature Shutdown Restart  
Hysteresis value.  
It is not necessary for the user to add capacitance at the  
Trim pin. The node is internally bypassed to eliminate noise.  
Total DC Variation of VOUT: For the converter to meet its  
full specifications, the maximum variation of the dc value of  
VOUT, due to both trimming and remote load voltage drops,  
should not be greater than that specified for the output  
voltage trim range.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 23  
Technical  
Specification  
IQ12xxxQGXxxx  
Application Section  
APPLICATION CONSIDERATIONS  
Input System Instability: This condition can occur because Application Circuits: Figure C provides a typical circuit diagram  
any dc-dc converter appears incrementally as a negative which details the input filtering and voltage trimming.  
resistance load. A detailed application note titled “Input System  
Instability” is available on the SynQor website which provides  
an understanding of why this instability arises, and shows the  
preferred solution for correcting it.  
Vout(+)  
Vin(+)  
Electrolytic  
Capacitor  
Vsense(+)  
External  
Input  
Filter  
Rtrim-up  
Vin  
Trim  
or  
ON/OFF  
Vin(_)  
Cload  
Rtrim-down  
Iload  
Vsense(_)  
Vout(_)  
Figure C: Typical application circuit (negative logic unit, permanently enabled).  
Input Filtering and External Capacitance: Figure D provides The recommended external input capacitance is specified in the  
a diagram showing the internal input filter components. This filter Input Characteristics section on the Electrical Characteristics  
dramatically reduces input terminal ripple current, which otherwise page. More detailed information is available in the application note  
could exceed the rating of an external electrolytic input capacitor. titled “EMI Characteristics” on the SynQor website.  
L
Vin(+)  
C
Vin(_)  
Figure D: Internal Input Filter Diagram (component values listed on the specifications page).  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 24  
Technical  
Specification  
IQ12xxxQGXxxx  
Application Section  
Startup Inhibit Period: The Startup Inhibit Period ensures that When the ON/OFF pin goes high after t2, the Startup Inhibit  
the converter will remain off for approximately 200 ms when it is Period has elapsed, and the output turns on within the typical  
shut down for any reason. When an output short is present, this Turn-On Time.  
generates a 5 Hz “hiccup mode,” which prevents the converter  
from overheating. In all, there are seven ways that the converter  
can be shut down, initiating a Startup Inhibit Period:  
Thermal Considerations: The maximum operating base-plate  
temperature, TB, is 100 ºC. As long as the user’s thermal system  
keeps TB < 100 ºC, the converter can deliver its full rated power.  
•ꢀ InputꢀUnder-VoltageꢀLockout  
•ꢀ InputꢀOver-VoltageꢀLockout  
•ꢀ OutputꢀOver-VoltageꢀProtection  
•ꢀ OverꢀTemperatureꢀShutdown  
•ꢀ CurrentꢀLimit  
A power derating curve can be calculated for any heatsink that is  
attached to the base-plate of the converter. It is only necessary  
to determine the thermal resistance, RTHBA, of the chosen heatsink  
between the base-plate and the ambient air for a given airflow  
rate. This information is usually available from the heatsink  
vendor. The following formula can the be used to determine the  
maximum power the converter can dissipate for a given thermal  
condition if its base-plate is to be no higher than 100 ºC.  
•ꢀ ShortꢀCircuitꢀProtection  
•ꢀ TurnedꢀoffꢀbyꢀtheꢀON/OFFꢀinput  
Figure E shows three turn-on scenarios, where a Startup Inhibit  
Period is initiated at t0, t1, and t2:  
100 ºC - TA  
Pmax  
=
diss  
RTH  
BA  
Before time t0, when the input voltage is below the UVL threshold,  
the unit is disabled by the Input Under-Voltage Lockout feature.  
When the input voltage rises above the UVL threshold, the Input  
Under-Voltage Lockout is released, and a Startup Inhibit Period is  
initiated. At the end of this delay, the ON/OFF pin is evaluated,  
and since it is active, the unit turns on.  
This value of power dissipation can then be used in conjunction  
with the data shown in Figure 2 to determine the maximum load  
current (and power) that the converter can deliver in the given  
thermal condition.  
For convenience, power derating curves for an encased converter  
without a heatsink and with a typical heatsink are provided for  
each output voltage.  
At time t1, the unit is disabled by the ON/OFF pin, and it cannot  
be enabled again until the Startup Inhibit Period has elapsed.  
V
in  
Under-Voltage  
Lockout Turn-  
On Threshold  
ON/OFF  
(neg logic)  
ON  
OFF  
ON  
OFF  
ON  
9ms  
(typical turn on time)  
V
out  
230ms  
(typical start-up  
inhibit period)  
200ms  
200ms  
t
t0  
t1  
t2  
Figure E: Startup Inhibit Period (turn-on time not to scale)  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 25  
Technical  
Specification  
IQ12xxxQGXxxx  
Standards & Qualification Testing  
Parameter  
Notes & Conditions  
STANDARDS COMPLIANCE  
UL 60950-1:2007  
Basic Insulation  
CAN/CSA-C22.2 No. 60950-1:2007  
EN60950-1/A12:2011  
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new  
releases or download from the SynQor website.  
Parameter  
QUALIFICATION TESTING  
Life Test  
# Units Test Conditions  
32  
5
95% rated Vin and load, units at derating point, 1000 hours  
Vibration  
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x, y, and z axis  
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
5
10  
5
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load  
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day  
5
5
Solderability  
15 pins MIL-STD-883, method 2003  
70,000 feet (21 km), see Note  
Altitude  
2
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 26  
Technical  
Specification  
IQ12xxxQGXxxx  
Standard Mechanical Diagram  
Top View  
1.536 ±0.020 (39.01 ±0.5)  
Side View  
1. 030 (26.16)  
0.600 (15.24)  
0.450 (11.43)  
0.300 (7.62)  
0.150 (3.81)  
0.253±0.020  
(6.4±0.5)  
0.18±0.010  
(4.57±0.25)  
0.263±0.020  
(6.68±0.5)  
8 7 6 5 4  
2.386  
± 0.020  
(60.6± 0.5)  
2.00  
(50.8)  
1.86  
(47.2)  
M3 Threaded Inserts  
4 Places  
See Notes  
1
3
2
0.183±.020 (4.65)±0.5  
0.500±0.025  
(12.7±0.63)  
Overall Height  
0.468±0.020 (11.89±0.5)  
0.300 (7.62)  
0.600 (15.24)  
NOTES  
PIN DESIGNATIONS  
1)  
M3 screws used to bolt unit’s baseplate to other surfaces (such as  
a heatsink) must not exceed 0.100" (2.54 mm) depth below the  
surface of the baseplate.  
Pin Name Function  
1
Vin(+) Positive input voltage  
2)  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
Applied torque per screw should not exceed 6in-lb. (0.7 Nm).  
2
ON/OFF  
Vin(–)  
3)  
4)  
Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface.  
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)  
diameter standoff shoulders.  
3
Negative input voltage  
4
Vout(–) Negative output voltage  
5)  
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)  
diameter standoff shoulders.  
1
5
SENSE(–) Negative remote sense  
2
6
TRIM  
Output voltage trim  
6)  
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over  
Nickel plate  
3
7
8
SENSE(+) Positive remote sense  
Vout(+) Positive output voltage  
7)  
Weight: 3.02 oz. (85.7 g) typical  
8)  
All dimensions in inches (mm)  
Notes:  
1)  
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
SENSE(–) should be connected to Vout(–) either remotely  
or at the converter.  
9)  
Workmanship: Meets or exceeds IPC-A-610 Class II  
2)  
3)  
Leave TRIM pin open for nominal output voltage.  
10)  
Recommended pin length is 0.03” (0.76mm) greater than the PCB  
thickness.  
SENSE(+) should be connected to Vout(+) either remotely  
or at the converter.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 27  
Technical  
Specification  
IQ12xxxQGXxxx  
Flanged Mechanical Diagram  
.01 [0.2]  
OVERALL HEIGHT  
.500 ±.025  
[12.7 ±0.63]  
.60 [ 15.2  
.45 [ 11.4  
]
]
2.200 ±.020 [ 55.88 ±0.5]  
1.536 ±.020 [ 39.01 ±0.5]  
.30 [ 7.6  
.15 [ 3.8  
]
.18  
[ 4.6  
SEE NOTE 5  
]
]
R .065  
4
5
6
7
8
[ 1.65 ]  
2.00  
[ 50.8  
TOP VIEW  
BOTTOM VIEW  
]
2.07  
[ 52.5]  
2.386 ±.020  
[ 60.6 ±0.5]  
1.66  
[ 42.2  
]
1.01 [25.7]  
.36 [9.1]  
3
2
1
1
.70  
[ 17.8  
.183 ±.020  
[ 4.65±0.5]  
1.30  
[ 33]  
.30 [ 7.6  
]
]
.13  
[ 3.2  
BOTTOMSIDE CLEARANCE  
.010 ±.020  
]
.800 ±.020  
[ 20.32 ±0.5]  
.60 [ 15.2  
]
.02 [ 0.6  
]
[0.51  
0.25]  
NOTES  
PIN DESIGNATIONS  
1)  
Applied torque per screw should not exceed 5in-lb.  
(3in-lb recommended).  
Baseplate flatness tolerance is 0.01” (.2mm) TIR for surface.  
Pin Name Function  
1
Vin(+) Positive input voltage  
2)  
3)  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
2
ON/OFF  
Vin(–)  
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)  
diameter standoff shoulders.  
3
Negative input voltage  
4)  
5)  
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)  
diameter standoff shoulders.  
All Pins: Material - Copper Alloy, Finish (RoHS 6/6) - Matte Tin over  
Nickel plate  
4
Vout(–) Negative output voltage  
1
5
SENSE(–) Negative remote sense  
2
6
TRIM  
Output voltage trim  
6)  
7)  
Total Weight: 3.12 oz (88.5 g)  
All dimensions in inches (mm)  
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
3
7
8
SENSE(+) Positive remote sense  
Vout(+) Positive output voltage  
Notes:  
1)  
SENSE(–) should be connected to Vout(–) either remotely  
or at the converter.  
8)  
9)  
Workmanship: Meets or exceeds IPC-A-610 Class II  
Recommended pin length is 0.03” (0.76mm) greater than the PCB  
thickness.  
A thermal interface material is required to assure proper heat transfer  
from the flanged baseplate to the cooling surface. Thermal grease  
may be used, or materials such as Thermalloy’s Grafoil or Bergquist  
HiFlow and Softflow. Other similar products are available from many  
heatsink manufacturers.  
2)  
3)  
Leave TRIM pin open for nominal output voltage.  
10)  
SENSE(+) should be connected to Vout(+) either remotely  
or at the converter.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 28  
Technical  
Specification  
IQ12xxxQGXxxx  
PART NUMBERING SYSTEM  
ORDERING INFORMATION  
The part numbering system for SynQor’s dc-dc converters follows the format  
shown in the example below.  
The tables below show the valid model numbers and ordering options for  
converters in this product family. When ordering SynQor converters, please  
ensure that you use the complete 15 character part number consisting of  
the 12 character base part number and the additional characters for options.  
Add “-G” to the model number for 6/6 RoHS compliance.  
IQ 12 018 Q G C 30 N R S - G  
Input  
Voltage  
Output  
Voltage Output Current  
Maximum  
Model Number  
6/6 RoHS  
IQ12018QGw30xyz  
IQ12033QGw20xyz  
IQ12050QGw15xyz  
IQ12070QGw10xyz  
IQ12120QGw06xyz  
IQ12150QGw05xyz  
IQ12240QGw03xyz  
IQ12300QGw2Exyz  
IQ12480QGw1Fxyz  
9-22V  
9-22V  
9-22V  
9-22V  
9-22V  
9-22V  
9-22V  
9-22V  
9-22V  
1.8 V  
3.3 V  
5 V  
30 A  
20 A  
15 A  
10 A  
6 A  
Options (see  
Ordering Information)  
Output Current  
7 V  
Thermal Design  
Performance Level  
Package Size  
12 V  
15 V  
24 V  
30 V  
48 V  
5 A  
3 A  
2.4 A  
1.5 A  
Output Voltage  
Input Voltage  
Product Family  
The following options must be included in place of the w x y z spaces in the  
model numbers listed above.  
The first 12 characters comprise the base part number and the last 3  
characters indicate available options. The “-G” suffix indicates 6/6 RoHS  
compliance.  
Options Description  
Thermal Design  
Enable Logic Pin Style  
Feature Set  
w
x
y
z
C - Encased  
V - Encased with  
Flanged Baseplate  
N - Negative  
R - 0.180"  
S - Standard  
Application Notes  
A variety of application notes and technical white papers can be downloaded  
in pdf format from our website.  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium, Hexavalent  
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated  
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor  
product is 6/6 RoHS compliant. For more information please refer to  
Not all combinations make valid part numbers, please contact SynQor for  
availability.  
SynQor’s RoHS addendum available at our RoHS Compliance / Lead  
Free Initiative web page or e-mail us at rohs@synqor.com  
.
PATENTS  
SynQor holds the following U.S. patents, one or more of which apply to  
each product listed in this document. Additional patent applications may  
be pending or filed in the future.  
5,999,417  
6,894,468  
6,222,742  
6,896,526  
6,545,890  
6,927,987  
6,577,109  
7,050,309  
6,594,159  
7,072,190  
7,558,083  
6,731,520  
7,085,146  
7,564,702  
7,119,524  
7,765,687  
7,269,034  
7,787,261  
7,272,021  
8,023,290  
7,272,023  
8,149,597  
Contact SynQor for further information and to order:  
Phone:  
978-849-0600  
Toll Free: 888-567-9596  
Warranty  
Fax:  
978-849-0602  
power@synqor.com  
www.synqor.com  
SynQor offers a two (2) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from  
SynQor.  
E-mail:  
Web:  
Address: 155 Swanson Road  
Boxborough, MA 01719  
USA  
Information furnished by SynQor is believed to be accurate and reliable.  
However, no responsibility is assumed by SynQor for its use, nor for any  
infringements of patents or other rights of third parties which may result  
from its use. No license is granted by implication or otherwise under any  
patent or patent rights of SynQor.  
Product # IQ12xxxQGXxxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005176 Rev. D  
04/09/13  
Page 29  

相关型号:

IQ12050QGV15NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK-8
SYNQOR

IQ12050QTA20NRS-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
SYNQOR

IQ12050QTB20NRS-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
SYNQOR

IQ12050QTC20NRS

Quarter-brick DC-DC Converter
SYNQOR

IQ12050QTC20NRS-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
SYNQOR

IQ12050SMC10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 500W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR

IQ12050SMV10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 500W, Hybrid, ROHS COMPLIANT, SIXTEENTH BRICK PACKAGE-8
SYNQOR

IQ1205S

DC/DC CONVERTER +/-5V 1W
XPPOWER

IQ1205SA

1 Watt
XPPOWER

IQ12070QGC10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK-8
SYNQOR

IQ12070QGV10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, ROHS COMPLIANT, QUARTER BRICK-8
SYNQOR

IQ12070QTA14NRS-G

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT, QUARTER-BRICK PACKAGE-8
SYNQOR