STTH1003S [STMICROELECTRONICS]
HIGH EFFICIENCY RECTIFIER; 高效率整流型号: | STTH1003S |
厂家: | ST |
描述: | HIGH EFFICIENCY RECTIFIER |
文件: | 总7页 (文件大小:91K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
STTH1003S
®
HIGH EFFICIENCY RECTIFIER
Table 1: Main Product Characteristics
A
K
A
IF(AV)
VRRM
trr (typ)
Tj
10 A
300 V
13 ns
175°C
0.9 V
K
VF (typ)
A
K
A
A
K
A
FEATURES AND BENEFITS
D2PAK
STTH1003SG
TO-220FPAB
STTH1003SFP
■
■
■
■
■
Ultrafast recovery
Low power losses
High surge capability
Low leakage current
High junction temperature
K
A
K
A
DPAK
STTH1003SB
DESCRIPTION
The STTH1003S is an Ultrafast Recovery Power
Rectifier dedicated to energy recovery in PDP
application.
It is especially designed for clamping function in
energy recovery block.
The compromise between forward voltage drop
and recovery time offer optimized performances.
Table 2: Order Codes
Part Numbers
STTH1003SFP
STTH1003SB
STTH1003SB-TR
STTH1003SG
Marking
STTH1003SFP
STTH1003SB
STTH1003SB
STTH1003SG
STTH1003SG
STTH1003SG-TR
Table 3: Absolute Ratings (limiting values)
Symbol
Parameter
Value
Unit
VRRM Repetitive peak reverse voltage
IF(RMS) RMS forward voltage
300
V
A
A
A
20
10
IF(AV) Average forward current
Tc = 150°C δ = 0.5
IFSM
IRSM
Tstg
Tj
Surge non repetitive forward current
tp = 10ms sinusoidal
tp = 20 µs square
100
Non repetitive avalanche current
Storage temperature range
4
A
-65 to + 175
175
°C
°C
Maximum operating junction temperature
August 2005
REV. 1
1/8
STTH1003S
Table 4:Thermal Parameters
Symbol
Parameter
Package
DPAK
Value
Unit
Rth(j-c) Junction to case
4
4
°C/W
D2PAK
TO220FP
6
Table 5: Static Electrical Characteristics
Symbol
Parameter
Test conditions
Tj = 25°C
Min.
Typ
10
Max.
Unit
10
100
1.30
1.1
IR *
VR = VRRM
Reverse leakage current
µA
Tj = 125°C
Tj = 25°C
Tj = 125°C
VF **
IF = 10A
Forward voltage drop
V
0.9
Pulse test:
* tp = 5 ms, δ < 2%
** tp = 380 µs, δ < 2%
2
To evaluate the conduction losses use the following equation: P = 0.86 x I
+ 0.024 I
F(AV)
F (RMS)
Table 6: Recovery Characteristics
Symbol
Parameter
Test conditions
Min. Typ Max. Unit
IF = 0.5A
IR = 1A
Irr = 0.25A
13
28
17
35
trr
Tj = 25°C
Reverse recovery time
ns
IF = 1A
VR = 30V
dIF/dt = -50 A/µs
IF = 10A dIF/dt = 100 A/µs
FR = 1.1 x VFmax
IF = 10A VCC = 200V
dIF/dt = 200 A/µs
tfr
Tj = 25°C
Forward recovery time
200
ns
A
V
IRM
Sfactor
VFP
Reverse recovery current
Softness factor
5.7 7.5
0.3
Tj = 125°C
Tj = 25°C IF = 10A dIF/dt = 100 A/µs
Peak forward voltage
2.5 3.5
V
Figure 1: Forward voltage drop versus current
(maximum values)
Figure 2: Peak reverse recovery current versus
dIF/dt (90% confidence)
I
(A)
I
(A)
RM
FM
16
14
12
10
8
100.0
10.0
1.0
VR=200V
Tj=125°C
Tj=125°C
IF = 2xIF(AV)
IF = IF(AV)
Tj=75°C
Tj=25°C
IF = 0.5xIF(AV)
6
4
2
V
(V)
FM
dI /dt(A/µs)
F
0.1
0
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
0
50
100
150
200
250
300
350
400
450
500
2/8
STTH1003S
Figure 3: Reverse recovery time versus dIF/dt
(90% confidence)
Figure 4: Softness factor versus dIF/dt (typical
values)
t (ns)
rr
S factor
100
0.60
VR=200V
Tj=125°C
VR=200V
Tj=125°C
90
80
0.50
70
0.40
0.30
0.20
0.10
IF = 2xIF(AV)
60
50
IF = IF(AV)
40
IF = 0.5xIF(AV)
30
20
10
dI /dt(A/µs)
dI /dt(A/µs)
F
F
0.00
0
0
50
100
150
200
250
300
350
400
450
500
0
50
100
150
200
250
300
350
400
450
500
Figure 5: Relative variations of dynamic
parameters versus junction temperature
(reference: Tj = 125°C)
Figure 6: Transient peak forward voltage
versus dIF/dt (90% confidence)
2.6
2.4
2.2
V
(V)
FP
8
7
6
5
4
3
2
1
0
IF=IF(AV)
Tj=125°C
2.0
S factor
1.8
1.6
1.4
1.2
1.0
0.8
IRM
0.6
0.4
0.2
T (°C)
j
dI /dt(A/µs)
F
0.0
0
50
100
150
200
250
300
350
400
450
500
25
50
75
100
125
Figure 7: Forward recovery time versus dIF/dt
(90% confidence)
t (ns)
fr
300
250
200
150
100
50
IF=IF(AV)
VFR=1.1 x VF max.
Tj=125°C
dI /dt(A/µs)
F
0
0
50
100
150
200
250
300
350
400
450
500
3/8
STTH1003S
Figure 8: DPAK Package Mechanical Data
DIMENSIONS
Millimeters Inches
Min. Min.
REF.
Max
2.40
1.10
0.23
0.90
5.40
0.60
0.60
6.20
6.60
4.60
10.10
Max.
0.094
0.043
0.009
0.035
0.212
0.023
0.023
0.244
0.259
0.181
0.397
A
A1
A2
B
2.20
0.90
0.03
0.64
5.20
0.45
0.48
6.00
6.40
4.40
9.35
0.086
0.035
0.001
0.025
0.204
0.017
0.018
0.236
0.251
0.173
0.368
E
A
B2
C2
L2
B2
C
D
R
H
L4
C2
D
A1
R
B
G
C
E
G
A2
H
0.60 MIN.
L2
L4
V2
0.80 typ.
0.031 typ.
V2
0.60
0°
1.00
8°
0.023
0°
0.039
8°
Figure 9: Foot Print dimensions (in millimeters)
1.6
6.7
3
3
2.3
2.3
6.7
1.6
4/8
STTH1003S
Inches
Figure 10: D2PAK Package Mechanical Data
DIMENSIONS
Millimeters
Min.
REF.
Max.
4.60
2.69
0.23
0.93
1.70
0.60
1.36
9.35
10.40
5.28
15.85
1.40
1.75
3.20
Min.
Max.
0.181
0.106
0.009
0.037
0.067
0.024
0.054
0.368
0.409
0.208
0.624
0.055
0.069
0.126
A
E
A
A1
A2
B
4.40
2.49
0.03
0.70
1.14
0.45
1.23
8.95
10.00
4.88
15.00
1.27
1.40
2.40
0.173
0.098
0.001
0.027
0.045
0.017
0.048
0.352
0.393
0.192
0.590
0.050
0.055
0.094
C2
L2
D
L
B2
C
L3
A1
C2
D
B2
B
R
C
E
G
G
A2
L
L2
L3
M
M
*
V2
* FLAT ZONE NO LESSTHAN 2mm
R
0.40 typ.
0.016 typ.
V2
0°
8°
0°
8°
Figure 11: Foot Print dimensions (in millimeters)
16.90
10.30
5.08
1.30
3.70
8.90
5/8
STTH1003S
Figure 12: TO-220FPAB Package Mechanical Data
DIMENSIONS
Millimeters Inches
Min. Max. Min.
4.4 4.6
REF.
Max.
0.181
0.106
0.108
0.027
0.039
0.067
0.067
0.205
0.106
0.409
A
A
B
0.173
0.098
0.098
0.018
0.030
0.045
0.045
0.195
0.094
0.393
B
H
2.5
2.5
2.7
2.75
0.70
1
D
E
0.45
0.75
1.15
1.15
4.95
2.4
Dia
F
L6
L5
F1
F2
G
1.70
1.70
5.20
2.7
L2
L4
L7
L3
G1
H
10
10.4
D
F1
F2
L2
L3
L4
L5
L6
L7
Dia.
16 Typ.
0.63 Typ.
28.6
9.8
30.6
10.6
3.6
1.126
0.386
0.114
0.626
0.354
0.118
1.205
0.417
0.142
0.646
0.366
0.126
F
E
2.9
G1
15.9
9.00
3.00
16.4
9.30
3.20
G
In order to meet environmental requirements, ST offers these devices in ECOPACK® packages. These
packages have a Lead-free second level interconnect . The category of second level interconnect is
marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The
maximum ratings related to soldering conditions are also marked on the inner box label. ECOPACK is an
ST trademark. ECOPACK specifications are available at: www.st.com.
6/8
STTH1003S
Table 7: Ordering Information
Ordering type
STTH1003SFP
STTH1003SB
Marking
Package
Weight
Base qty
50
Delivery mode
Tube
STTH1003SFP
STTH1003SB
STTH1003SB
STTH1003SG
STTH1003SG
TO-220FPAB
1.70 g
75
Tube
DPAK
0.3 g
STTH1003SB-TR
STTH1003SG
2500
50
Tape & reel
Tube
D2PAK
1.48 g
STTH1003SG-TR
1000
Tape & reel
■
■
■
■
Epoxy meets UL94, V0
Cooling method: by conduction (C)
Recommended torque value: 0.8 m.N.
Maximum torque value: 1.0 m.N.
Table 8: Revision History
Date
Revision
Description of Changes
24-Aug-2005
1
First issue.
7/8