SP-12-LR2-RDA [SOURCE]
622 Mbps SFP Transceiver; 622千兆SFP收发器型号: | SP-12-LR2-RDA |
厂家: | SOURCE PHOTONICS, INC. |
描述: | 622 Mbps SFP Transceiver |
文件: | 总7页 (文件大小:469K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
622 Mbps SFP Transceiver
SP-12-LR2
Features
• Compliant with OC12/STM-4 Standards
• Single 3.3 V supply
• 25 dB minimum link budget
• 1550nm DFB Laser, 80 km reach
• Commercial Temperature Available (-Cxx)
• Reduced Industrial Temperature Available (-Rxx)
• Industrial Temperature Available (-Txx)
• SFP MSA SFF-8074i compliant
• Digital Diagnostic SFF-8472 Compliant
• Telcordia GR-468 compliant
• Color coded bail latch: White
• RoHS-5/6 compliant product (lead exemption)
General operating
Parameter
Symbol
Vcc
Min.
3.135
-
Typical
Max.
3.465
300
-
Unit
V
Supply Voltage
3.3
Total Current
Icc
-
mA
mVp-p
ºC
Power Supply Noise Rejectiona
Operating Temperature (-Cxx)
Operating Temperature (-Rxx)
Operating Temperature (-Txx)
Storage Temperature
Data Rate OC12/STM-2
PSR
Top
100
-5
-
-
70
Top
-20
-40
-40
-
-
85
ºC
Top
-
-
85
ºC
Tst
85
ºC
DR
622
-
Mbps
a) 20Hz to 155MHz
Transmitter Specifications
Parameter
Symbol
Min
Typical
Max
+2
Unit
-3
0
-
dBm
P
Optical Power
OP
Average Launch Power Of Off Tx
Extinction Ratio
-
-45
-
dBm
P
Off
ER
10
-
dB
Eye Mask
-
-
-
SONET/SDH compliant
Optical Jitter Generation
Optical Rise Timeb
Jgen
tr
-
-
0.002
500
500
1580
1
UI
ps
-
-
Optical Fall Timeb
tf
-
ps
Mean Wavelength
λ
1480
1550
nm
nm
dB
Spectral Width (-20dB width)
Side Mode Suppression Ratio
Dispersion Penalty (at 80 Km)
Relative Intensity Noise
∆λ
SMSR
-
-
-
-
-
-
30
0.5
-
1
dB
RIN
-120
dB/Hz
b) 20%-80% values
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
1
622 Mbps SFP Transceiver
SP-12-LR2
Transmitter Specifications (Electical)
Parameter
Symbol
Rin
Min
80
250
2
Typical
Max
120
Unit
Ω
100
Input Differential Impedence
PECL Single Ended Data Input Swing
TxFault_Fault
Vin,p-p
Vfault
-
-
-
-
-
1200
Vcc
mV
V
TxFault_Normal
Vnormal
Vee
2
Vee+0.5
Vcc
V
TxDisable_Disable
V
Vd
TxDisable_Enable
Vee
Vee+0.8
V
Ven
Receiver Specifications
Parameter
Symbol
Rsens,low
Rsens,high
Pin,damage
λ
Min
-
Typical
Max
Unit
dBm
dBm
dBm
nm
Receive Power Lowc
Receive Power High
Damage Threshold For Receiver
Wavelengthd
-30
-28
-8
-
-
0
-
-
1580
-
1480
-45
-
1550
LOS Assert
-
-
-
dBm
dBm
dB
LOS De-assert
-28
-
LOS Hysteresis
0.5
c) 10-12 at nominal wavelength
d) Operational over 1200 to 1625 nm range
Electrical Output
Parameter
Symbol
Min
Typical
Max
800
500
500
Unit
mV
ps
Vout, p-p
185
-
-
-
PECL Single Ended Data Output Swing
tr
tf
-
-
Data Output Rise Time
Data Output Fall Time
ps
Timing and Electrical
Parameter
Symbol
Min
Typical
Max
1
Unit
ms
µs
ms
µs
µs
µs
µs
KHz
V
t_on
t_off
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Tx Disable Negate Time
Tx Disable Assert Time
Time To Initialize, Including Reset Of Tx Fault
Tx Fault Assert Time
10
t_init
-
300
100
-
t_fault
-
Tx Disable To Reset
t_reset
10
-
Los Assert Time
t_loss_on
t_loss_off
f_serial_clock
100
100
100
-
Los De-assert Time
-
Serial ID Clock Rate
-
RX_LOS Voltage (High)
RX_LOS Voltage (Low)
LOS Output Voltage-Fault
LOS Output Voltage-Normal
MOD_DEF (0:2)-High
2
-
0.8
V
VLOS fault
2
Vcc
V
VLOSnormal
Vee
2
Vee+0.5
Vcc
V
Vh
Vl
V
MOD_DEF (0:2)-LOW
Vee
Vee+0.5
V
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
2
622 Mbps SFP Transceiver
SP-12-LR2
Diagnostics
Range
-5 to 70
-20 to 85
-40 to 85
Accuracy
±3
Unit
ºC
Calibration
Formula
Parameter
Internal
Internal
Internal
Internal
External
Tc(C)=Tad(16 bit signed twos complement)/256
Tc(C)=Tad(16 bit signed twos complement)/256
Tc(C)=Tad(16 bit signed twos complement)/256
V(Volts)=Vad(16 bit unsigned integer)*0.1
Temperature (-CDx)
Temperature (-RDx)
Temperature (-TDx)
Voltage
±3
ºC
±3
ºC
0 to V
cc
±0.1
±5
V
Bias current
0 to 120
-3 to +2
-28 to -8
mA
I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset
TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer)
+TX_PWRoffset
TX Power
RX Power
±3 dB
±3 dB
dBm
dBm
External
External
RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
EEPROM Serial ID
Name of Field
Description of Field
Address
20
Hex
4C
55
4D
49
4E
ASCII
L
U
M
I
21
22
23
24
N
E
SFP Vendor name(ASCII)
25
45
4E
Vendor Name
26
N
T
27
54
4F
28
O
I
29
49
43
30
C
37
38
39
00
06
B5
IEEE vendor OUI code for LuminentOIC
Inc.
Vendor OUI
40
41
42
43
44
45
46
47
48
49
53
50
31
32
4C
52
32
43
4E
41
S
P
1
2
L
Part number in ASCII, e.g.
SP-12-LR2-CNA
Vendor PN
R
2
C
N
A
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
3
622 Mbps SFP Transceiver
SP-12-LR2
Pinout Definitions
Function
Vee
Notes
TX Ground
Pin
1
T
Open Collector
Internally Pulled High
Serial Data Input
Serial Clock Input
Internally Grounded
Not Connected
Open Collector
RX Ground
2
TX_FAULT
TX_DISABLE
MOD_DEF2
MOD_DEF1
MOD_DEF0
NC
3
4
5
6
7
8
LOS
Vee
Vee
Vee
R
R
R
9
RX Ground
10
11
12
13
14
RX Ground
RX Data Negative
RX Data Positive
RX Ground
RXD-
RXD+
Vee
R
VccR
VccT
RX Power
15
TX Power
TX Ground
16
17
18
19
20
Vee
T
TXD+
TXD-
TX Data Positive
TX Data Negative
TX Ground
Vee
T
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
4
622 Mbps SFP Transceiver
SP-12-LR2
Outline drawing
Units in mm(inches)
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
5
622 Mbps SFP Transceiver
SP-12-LR2
Suggested Transceiver Interface
1�H
1�H
Vcc
10�F
0.1�F
VCCT
.01�F
Protocol IC
LuminentOIC
SFP
R1
10Kꢀ
TX_DISABLE
TX_DISABLE
TX_FAULT
TD +
Laser Driver
TX_FAULT
.01�F
SerDes
100ꢀ
TD -
.01�F
VEET
VCCR
0.1�F
RD +
10�F
Receiver Amplifier
.01�F
.01�F
100ꢀ
RD -
RX_LOS
VEER
RX_LOS
Vcc
R
EEPROM
1
R1
R1
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10Kꢀ
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
6
622 Mbps SFP Transceiver
SP-12-LR2
Ordering Information
Available Options:
SP-12-LR2-CNA
SP-12-LR2-RNA
SP-12-LR2-TNA
SP-12-LR2-CDA
SP-12-LR2-RDA
SP-12-LR2-TDA
Part numbering Definition:
SP - 12 - LR2 - Temperature Diagnostic Revision
• SP = Small Form Pluggable
12 = OC12, 622 Mbps
LR2 = Long Reach 80 km
• Operating Temperature
C = Commercial temperature (-5 to 70ºC)
R = Reduced Industrial temperature (-20 to 85ºC)
T = Industrial temperature (-20 to 85ºC)
• D = Digital Diagnostic (SFF-8472)
N = No Digital Diagnostic
• Design Revision
A = RoHS-5/6 compliant product (lead exemption)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1502-Dec0806
Rev A.1
7
相关型号:
©2020 ICPDF网 联系我们和版权申明