XC-ST30CE [SONY]

CCD B/W VIDEO CAMERA MODULE; CCD /黑白摄像机模块
XC-ST30CE
型号: XC-ST30CE
厂家: SONY CORPORATION    SONY CORPORATION
描述:

CCD B/W VIDEO CAMERA MODULE
CCD /黑白摄像机模块

CD 摄像机
文件: 总31页 (文件大小:579K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CCD B/W VIDEO  
CAMERA MODULE  
XC-ST50/50CE  
XC-ST30/30CE  
User’s  
Guide  
(Ver. 1.0)  
English —  
XC-ST50/50CE  
XC-ST30/30CE  
Table of Contents  
OUTLINE ................................................................................................................. 1  
MAIN FEATURES .................................................................................................... 1  
SPECIFICATIONS COMPARISON .......................................................................... 2  
SYSTEM CONFIGURATION ................................................................................... 2  
MAIN SPECIFICATIONS ......................................................................................... 3  
CONNECTION DIAGRAM ....................................................................................... 4  
LOCATION OF PARTS AND OPERATION ............................................................. 5  
PHASE CONDITIONS OF EXTERNAL SYNCHRONIZATION................................ 6  
ELECTRONIC SHUTTER........................................................................................ 7  
RESTART RESET (R.R) ........................................................................................ 10  
FRAME IMAGE OUTPUT WITH STROBE LIGHT ................................................ 12  
OUTPUT WAVEFORM TIMING CHART (XC-ST50 (EIA)/XC-ST30 (EIA)) ........... 13  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1....................... 17  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2....................... 23  
DIMENSIONS ........................................................................................................ 25  
SPECTRAL RESPONSE CHARACTERISTICS (TYPICAL VALUE) ..................... 26  
COMPARISON OF SPECTRAL RESPONSE CHARACTERISTICS (TYPICAL VALUE) .... 26  
VARIOUS LENS SELECTION............................................................................... 27  
XC-ST50/50CE  
XC-ST30/30CE  
OUTLINE  
The XC-ST50/50CE and XC-ST30/30CE are compact, lightweight, black-and-white camera modules of a new  
concept, which are produced as input devices for image processing by using the latest technology. These models  
inherit the basic functions of the XC-75 (installing a 1/2-inch CCD) and the XC-73 (installing a 1/3-inch CCD),  
which are used in various types of devices and systems and win popularity in the machine vision field. The XC-  
ST50/50CE and XC-ST30/30CE provides an external trigger shutter that can catch a high-speed moving subject  
using an external signal. This enables a still image to be read in arbitrary timing. These two models are compatible  
with each other, thereby functioning in the same cabinet and by the same operation. The user can select a model  
according to the conditions of subjects and optical conditions. In addition, the XC-ST50/50CE and XC-ST30/30CE  
enable functions to be set on the rear panel for improved operability and have an internal configuration which  
implements significant shock and vibration resistance, allowing easy incorporation into machine vision equipment.  
MAIN FEATURES  
1/2", 1/3" IT CCD  
External trigger shutter function  
(XC-ST50/ST30: 1/4 to 1/10,000 seconds,  
XC-ST50CE/ST30CE: 1/4 to 1/8,000 seconds)  
Inputting the trigger pulse gives one still image. This feature allows the capture of high-speed moving object.  
Restart Reset (R.R) function  
Inputting HD and VD signals (2 VD or more) continuously from the outside can catch one image at arbitrary time  
and control the exposure time of CCD.  
This function is used for long exposures and strobe with frame image output.  
Synchronization system: Internal/external HD/VD, and VS  
(VS is used only during external synchronization.)  
Inputting an HD/VD signal from the outside automatically establishes external synchronization.  
This function is effective for controlling multiple cameras efficiently from the external system.  
Setting each mode on rear panel:  
The setting of each mode can be changed by selecting DIP and rotary switch.  
Almost all switches are located on the rear panel. This feature permits easy setting after equipment is installed.  
Compact and lightweight  
C-mount  
Excellent shock and vibration resistance  
Compatibility  
These models are the same in the size and functions as the XC-ST70. They can be operated in the same way as  
the XC-ST70 (installing 2/3-inch CCD). Therefore, they provide high compatibility.  
1
XC-ST50/50CE  
XC-ST30/30CE  
SYSTEM CONFIGURATION  
The components making up the system based on XC-ST50/ST50CE or XC-ST30/ST30CE video camera are as  
follows.  
Camera cables  
Video camera module  
XC-ST50/50CE  
XC-ST30/30CE  
Camera adaptor  
DC-700/700CE  
CCXC-12P02N (2 m)  
CCXC-12P05N (5 m)  
CCXC-12P10N (10 m)  
CCXC-12P25N (25 m)  
Junction box  
JB-77  
Tripod adaptor  
VCT-ST70I (Isolated type)  
C-mount lenses  
VCL-50Y-M  
VCL-25Y-M  
VCL-16Y-M  
VCL-12YM  
Close-up ring kit  
LO-77ERK  
VCL-08YM  
SPECIFICATIONS COMPARISON  
XC-ST50  
XC-75  
XC-ST30  
XC-73  
Image device  
1/2-inch interline transfer CCD 1/2-inch interline transfer CCD 1/3-inch interline transfer CCD 1/3-inch interline transfer CCD  
Effective picture elements 768 (H) x494 (V)  
768 (H) x494 (V)  
C mount  
768 (H) x494 (V)  
C mount  
768 (H) x494(V)  
C mount  
Lens mount  
Scanning system  
Sensitivity  
C mount  
2:1 interlaced  
400 lx F8  
0.3 lx  
2:1 interlaced  
400 lx F4  
2:1 interlaced  
400 lx F8  
2:1 interlaced  
400 lx F4  
Minimum  
3.0 lx  
0.3 lx  
3.0 lx  
illuminance  
S/N ratio  
60db  
56db  
56db  
56db  
Normal shutter  
External trigger  
shutter  
1/100 to 1/10,000  
1/4 to 1/10,000  
1/100 to 1/10,000  
1/100 to 1/10,000  
1/4 to 1/10,000  
1/100 to 1/10,000  
1/100 to 1/1,600  
1/100 to 1/1,600  
Can be changed by the  
trigger pulse width or rear  
panel switch.  
Can be changed by the  
trigger and VD. Internal  
Can be changed by the  
trigger pulse width or  
Can be changed by the  
trigger and VD. Internal  
setting needs to be changed.  
setting needs to be changed. rear panel switch.  
Dimensions  
Mass  
44 (W) x29 (H) x57.5 (D) mm 44 (W) x29 (H) x71 (D) mm  
44 (W) x29 (H) x57.5 (D) mm 44 (W) x29 (H) x71 (D) mm  
110 g  
140 g  
110 g  
140 g  
Shock resistance  
10G (in the X, Y, and Z  
directions at 20 to 200 Hz)  
7G (in the X, Y, and Z  
directions at 11 to 200 Hz)  
10G (in the X, Y, and Z  
directions at 20 to 200 Hz)  
7G (in the X, Y, and Z  
directions at 11 to 200 Hz)  
2
XC-ST50/50CE  
XC-ST30/30CE  
MAIN SPECIFICATIONS  
Image pickup device  
XC-ST50/50CE:  
XC-ST30/30CE:  
Number of effective pixels  
Gain  
AGC/Manual/Fixed  
1/2-inch interline transfer CCD  
1/3-inch interline transfer CCD  
(Can be selected using the  
switch on the rear panel.)  
ON/OFF  
Gamma correction  
XC-ST50/ST30:  
768(H) x 494(V)  
(Can be selected using the  
switch on the rear panel.)  
XC-ST50CE/ST30CE: 752(H) x 582(V)  
CCD horizontal driving frequency  
Electronic shutter  
XC-ST50/ST30:  
XC-ST50/ST30:  
14.318 MHz  
1/100 to 1/10,000 seconds  
XC-ST50CE/ST30CE: 14.187 MHz  
CCD vertical driving frequency  
XC-ST50CE/ST30CE: 1/120 to 1/10,000 seconds  
External trigger shutter  
XC-ST50/ST30:  
15.734 kHz  
XC-ST50/ST30:  
1/4 to 1/10,000 seconds  
XC-ST50CE/ST30CE: 15.625 kHz  
XC-ST50CE/ST30CE: 1/4 to 1/8,000 seconds  
Set using the DIP switch on the rear panel, or  
Signal system  
Cell size  
XC-ST50:  
EIA/CCIR  
*
continuously variable with the trigger pulse width.  
8.4(H) x 9.8(V) um  
8.6(H) x 8.3(V) um  
6.35(H) x7.4(V) um  
6.5(H) x6.25(V) um  
C mount  
Supply voltage  
+12 VDC (+10.5 V to 15V)  
XC-ST50/50CE: 2.0 W  
XC-ST30/30CE: 1.9 W  
–5 ˚C to +45 ˚C  
XC-ST50CE:  
XC-ST30:  
Power consumption  
XC-ST30CE:  
Operating temperature  
Storage temperature  
Lens mount  
–30 ˚C to +60 ˚C  
Flange back  
17.526 mm  
Performance assurance temperature  
0 ˚C to +40 ˚C  
Synchronization system  
Internal/external  
Operating humidity  
Storage humidity  
Vibration resistance  
20 to 80 % (Non-condensing)  
(Selected automatically)  
20 to 95 % (Non-condensing)  
10G  
External sync input/output  
HD/VD (2 to 5 Vp-p)  
(For 20 minutes in the X, Y, and  
Z directions at 20 to 200 Hz)  
70G  
VS (Sync level: 0.3 Vp-p+0.3V  
)
Automatically selected acc0o.1r5dVing  
to the existence of an input signal  
when the selection switch on the  
rear panel is set to EXT.  
Shock resistance  
Outside dimensions  
Weight  
*
44(W) x 29(H) x 57.5(D) mm  
110 g  
Standards  
UL1492, FCC Class A Digital  
Device, and CE (EN50081-2 +  
EN50082-2)  
Allowable frequency deviation of external synchronization  
± 1 %  
(in horizontal synchronous frequency)  
Other  
Restart Reset function  
Frame or field integration can be  
selected.  
Jitter  
Within ± 50 nsec  
2:1 interlaced  
Scanning system  
Non-interlaced  
Conforms to new 12-pin EIAJ  
assignment.  
(during external sync input)  
Horizontal resolution  
XC-ST50/ST30:  
Accessories  
Lens mount cap (1)  
Instruction Manual (1)  
570 TV lines  
XC-ST50CE/ST30CE: 560 TV lines  
Sensitivity  
External synchronization for each mode  
XC/ST50/50CE:  
XC/ST30/30CE:  
400 lx F8 (r=ON,0 dB)  
400 lx F5.6 (r=ON,0 dB)  
External sync  
Mode  
Internal sync  
HD/VD  
VS  
Normal  
Normal shutter  
S/N ratio  
XC-ST50/50CE:  
XC-ST30/30CE:  
60 dB/58dB  
56 dB/54dB  
Mode 1  
×
Trigger signal  
generates an  
internal VD  
Minimum illuminance 0.3 lx (F1.4, AGC ON)  
Mode 2  
×
×
×
(single) signal.  
×
Restart Reset  
: Can be used.  
×: Cannot be used.  
3
XC-ST50/50CE  
XC-ST30/30CE  
CONNECTION DIAGRAM  
AC  
C-mount lens  
VIDEO OUT  
1
HD/VD  
*
2
VS  
*
WEN  
TRIG  
VCL-08Y-M  
Camera adaptor  
DC-700/CE  
(Conforms to new EIAJ and uses 12-pin assignment.)  
VCL-12Y-M  
VCL-16Y-M  
VCL-25Y-M  
XC-ST50/50CE  
XC-ST30/30CE  
AC  
VIDEO OUT  
1
HD/VD  
*
2
VS  
*
Camera cable  
CCXC-12P02N  
CCXC-12P05N  
CCXC-12P10N  
CCXC-12P25N  
Camera adaptor  
DC-777/CE  
Tripod adaptor  
VCT-ST70I  
(No trigger input terminal is provided.)  
AC  
VIDEO OUT  
1
HD/VD  
*
2
VS  
*
VCL-50Y-M  
LO-77ERK  
Camera adaptor  
DC-77RR/CE  
(No trigger input terminal is provided.)  
Close-up ring kit  
DC +12 V  
VIDEO OUT  
1
HD/VD  
*
1: An HD/VD signal cannot be used simultaneously with a VS signal.  
2: A VS signal cannot be used simultaneously with an HD/VD signal.  
2
VS  
*
*
Junction box  
JB-77  
*
Note : All functions of the XC-ST50/50CE and XC-ST30/30CE cannot  
be used when using DC-777/CE, DC-77RR/CE, and JB-77.  
Refer to the table shown below.  
(No trigger input terminal is provided.)  
DC-777/CE DC-77RR/CE  
JB-77  
XC-ST50/50CE  
XC-ST30/30CE  
Normal  
Normal shutter  
Restart Reset (R.R)  
Restart Reset (R.R)  
+
shutter  
×
×
×
External trigger shutter  
: Can be used.  
: Cannot be used.  
×
4
XC-ST50/50CE  
XC-ST30/30CE  
LOCATION OF PARTS AND OPERATION  
XC-ST50/50CE  
XC-ST30/30CE  
1 Lens mount section  
2
A commercial C-mount lens as well as a  
(XC-ST50 model)  
Sony standard lens can be used.  
2 Camera mounting reference hole  
These screw holes are positionned with  
high precision related to CCD sensor.  
CCD  
4 5  
VIDEO CAMERA MODULE  
1
3
Screw hole for tripod adaptor mounting  
XC-ST50  
(VCT-ST70I)  
4 12-pin multi-connector  
DC IN/SYNC (DC power/sync signal input)  
2 3  
3
5 BNC connector  
VIDEO OUT  
6 7  
4
γ
6
correction  
ON/OFF selector switch  
7 Internal/external sync selector  
5
switch  
The camera operates with internal syn-  
chronization when there is no external  
sync input signal in the EXT position.  
In this case, an HD/VD signal is not out-  
put from the 12-pin multi-connector.  
8
A
B
=
9
8 Trigger polarity selector switch  
This switch can select the polarity (nega-  
tive or positive) of a trigger pulse.  
4
12-pin multi-connector  
External HD/VD  
synchronization  
Internal HD/VD  
External VS  
Pin No.  
synchronization synchronization  
9 75 termination selector switch  
1
2
GND  
+12 V  
GND  
+12 V  
GND  
+12 V  
0 Selection DIP switch  
Switches 1 to 4:  
3
GND  
GND  
GND  
Selects the shutter speed.  
Switch 5: Selects the frame or field  
Switches 6 to 8:  
4
VIDEO output  
GND  
VIDEO output  
GND  
VIDEO output  
5
GND  
Selects the normal shutter,  
external trigger shutter, and  
restart/reset.  
6
External HD input Internal HD output  
7
1 External VD input Internal VD output  
VS  
*
8
GND  
GND  
GND  
A GAIN switch  
9
A: Outputs a fixed-level video signal ac-  
cording to the brightness of a sub-  
ject. (Variable range: 0 to 18 dB)  
F: Fixed gain 0 dB  
10  
11  
12  
2 WEN output  
TRIG input  
GND  
2 WEN output  
TRIG input  
GND  
2 WEN output  
*
*
*
TRIG input  
GND  
M: Variable gain (Manual)  
1: An input VD signal is required when the restart/reset mode is used.  
2: A WEN output signal is valid only in the external trigger shutter mode.  
M (during factory setting):  
*
*
Adjusted so that all XC-ST50/50CEs  
or XC-ST30/30CEs are the same in  
sensitivity (set by Sony’s standard  
value) according to the deviation in  
sensitivity of CCD.  
Valid when multiple XC-ST50/50CEs  
or XC-ST30/30CEs are used for an  
identical subject.  
Factory-setting mode of rear panel  
Corresponding  
No.  
Factory-setting  
mode  
Switch  
correction ON/OFF selector switch  
γ
6
7
8
9
OFF  
EXT  
+
Internal/external sync selector switch  
Trigger polarity selector switch  
75 termination selector switch  
Selection DIP switch  
ON  
B Volume control switch  
This switch can be changed in the range  
of 0 to 18 dB when the GAIN switch is set  
to “M”.  
0
A
1, 2, 3, 4: Selects the Shutter speed.  
5: Selects the field and frame integration.  
6, 7, 8: Selects the normal shutter, external trigger shutter, and restart/reset.  
GAIN switch  
OFF  
(All set to  
the left.)  
During factory setting, this switch is ad-  
justed to the fixed sensitivity for a stan-  
dard subject.  
FIX  
5
XC-ST50/50CE  
XC-ST30/30CE  
PHASE CONDITIONS OF EXTERNAL  
SYNCHRONIZATION  
External synchronization for each mode  
• For normal video/normal shutter  
Continuous HD/VD signal (should conform to EIA and CCIR frequencies in the timing shown in the figure below.)  
• For Restart Reset (RR)/external trigger shutter  
Continuous HD signal. The phase between VD (reset) and HD signals is as specified in the figure below in any  
timing.  
Phase conditions  
The phase relation between external input HD and VD signals should be set as shown below with respect to the  
specified center phase.  
5
200  
EXT-VD  
ODD  
(EVEN)  
100  
200  
EVEN  
(ODD)  
EXT-HD  
455 (454)  
455 (454)  
Unit: Clock  
1 CLK = 69.84 n sec (XC-ST50/ST30)  
= 70.48 n sec (XC-ST50CE/ST30CE)  
The operation in parentheses refers to XC-ST50CE/ST30CE.  
Note  
: The synchronized VD signals are delayed for 1H at HD/VD external synchronization mode, while  
there is no VD signal delay at VS external synchronization mode.  
6
XC-ST50/50CE  
XC-ST30/30CE  
ELECTRONIC SHUTTER  
Two types of electronic shutter are provided “normal shutter and external trigger shutter”.  
The electronic shutter speed and type can be set using the DIP switch on the rear panel.  
DIP switch on the rear panel  
Rear panel  
DIP switch  
Switches 1 to 4: Selects the shutter speed.  
Switch 5:  
Selects the frame or field integration.  
Switches 6 to 8: Selects the normal shutter, external trigger shutter, and Restart Reset.  
Normal shutter  
This mode provides continuous video output with the electronic shutter selected by switches to clearly capture a  
high-speed moving object.  
Setting of normal shutter speed  
Shutter  
Off  
Flickerless  
*
Switch  
1/125  
1/250  
1/500  
1/1000  
1/2000  
1/4000  
1/10000  
1
0
1
0
0
1
1
0
1
2
3
4
5
6
7
8
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
1
1
0
In the flickerless mode, the normal  
shutter speed is 1/100  
sec for  
XC-ST50/ST30 (EIA)  
and 1/120 sec for  
*
1
Frame: 0 / Field: 1  
1: ON  
0: OFF  
–: Any  
: It is recommended to set DIP switch 5 for field selection. (The field selection is about two times in sensitivity as high as the frame selection.)  
Note  
7
XC-ST50/50CE  
XC-ST30/30CE  
ELECTRONIC SHUTTER  
External trigger shutter  
By inputting an external trigger, a high-speed moving subject can be caught at an exact position.  
Set DIP switches 6, 7, and 8 on the rear panel to mode 1 or 2. (Refer to the table below.)  
When the trigger pulse width is 1/3 sec or more, the output signal is switched to a normal video signal.  
There are two modes for timing in which a video signal is obtained.  
Mode 1 (Non-reset mode)  
In this mode, a video signal synchronized with a VD signal is output after a trigger pulse is input.  
A video signal is synchronized with the external VD signal when an external HD/VD signal is input.  
A video signal is synchronized with an internal VD signal when no external HD/VD signal is input.  
Mode 2 (Reset mode)  
In this mode, a video signal is output from a trigger pulse after a certain period of time.  
For more details of each timing chart, refer to pages 16 to 23.  
*
Setting of external trigger shutter speed  
There are two ways to set the shutter speed.  
Using DIP switch on the rear panel  
Mode 1 (Non-reset mode)  
Switch  
1/100  
*
1/125  
1/250  
1/500  
1/1000 1/2000  
1/4000  
1/10000  
**  
1
2
3
4
5
6
7
8
1
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
Frame: 0 / Field: 1  
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
Mode 2 (Reset mode)  
The external trigger shutter speed is set to  
1/100 sec for XC-ST50/ST30(EIA) and 1/120  
*
1/100  
*
Switch  
1/125  
1/250  
1/500  
1/1000 1/2000  
1/4000  
1/10000  
**  
sec for XC-ST50CE/30CE(CCIR).  
1
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
1
1
2
3
4
5
6
7
8
The external trigger shutter speed is set to  
** 1/10000 sec for XC-ST50/ST30(EIA) and  
1/8000 sec for XC-ST50CE/30CE(CCIR).  
Frame: 0 / Field: 1  
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
1: ON  
0: OFF  
–: Any  
Using trigger pulse width  
Set all of DIP switches 1 to 4 on the rear panel to 0.  
An arbitrary shutter speed can be obtained by setting the trigger pulse width to the range of 2 µsec to 250  
msec.  
Exposure time = Trigger pulse width + 97 µsec (XC-ST50/ST30)  
Mode 1  
Mode 2  
Switch  
(Non-reset mode) (Reset mode)  
120 µsec (XC-ST50CE/ST30CE)  
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
:
1. lt is recommended to set DIP switch 5 for field selection.  
Note  
(The field selection is about two times in sensitivity as high as the frame selection.)  
2. After a trigger pulse is input, a new trigger pulse must not be input before the video  
signal obtained by the trigger pulse has been output.  
Frame: 0 / Field: 1  
0
1
1
0
0
1
1: ON  
0: OFF  
8
XC-ST50/50CE  
XC-ST30/30CE  
ELECTRONIC SHUTTER  
Specifications of trigger pulse  
When using a trigger pulse like shown below, set the TRIG polarity selector switch on the rear panel to + :  
A
B
T
A: 2 to 5.0 V  
B: 0 to 0.6 V  
T: 2 µs to 1/4 s, 100 µs to 1/4 s when setting the shutter speed using DIP switch  
When using a trigger pulse like shown below, set the TRIG polarity selector switch on the rear panel to – :  
A
B
T
A: 4.0 to 5.0 V  
B: 0 to 2.0 V  
T: 2 µs to 1/4 s, 100 µs to 1/4 s when setting the shutter speed using DIP switch  
Input impedance: 10 kor more  
*
*
The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.  
Specifications of WEN (Write ENable Pulse)  
A
B
T
A: 5.0 V  
B: 0 V  
T: 15.875 ms (XC-ST50/30), 18.752 ms (XC-ST50CE/30CE)  
Output impedance: 10 kor more  
*
9
XC-ST50/50CE  
XC-ST30/30CE  
RESTART RESET (R.R)  
The information on one screen can be extracted at any time by inputting a restart/reset signal (HD/VD) from the  
outside. To enter this mode, set DIP switches 6, 7, and 8 on the rear panel of a camera as shown in the table below.  
The setting is especially effective for the following operation.  
Restart Reset (R.R)  
Switch  
0
0
0
0
0
1
1
1
1
2
3
4
5
6
7
8
1: ON  
0: OFF  
Long exposure  
A high-sensitivity image is obtained by extending the exposure time of the CCD when satisfactory sensitivity  
cannot be obtained under ordinary operating conditions or when observing the trail of a moving object.  
The exposure time is determined by the VD interval (T) period between external VD pulses as follows.  
Timing and conditions  
Example 1 of Long exposure  
EXT HD  
EXT VD  
Continuous signal: 15.734 kHz (XC-ST50/ST30), 15.625 kHz (XC-ST50CE/30CE) Allowable frequency value ±1%  
VD interval(T): 262.5H or more (XC-ST50/ST30), 312.5H or more (XC-ST50CE/30CE) and 1 second or less (Recommended)  
Four or more VD pulses are required.  
T
T
T
Exposure time for Odd field  
Exposure time for Even field  
Video output  
Odd image  
Even image  
Invalid image  
Valid frame image  
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.  
10  
XC-ST50/50CE  
XC-ST30/30CE  
RESTART RESET (R.R)  
Example 2 of long exposure  
EXT HD  
EXT VD  
Continuous signal: 15.734 kHz (XC-ST50/ST30), 15.625 kHz (XC-ST50CE/30CE) Allowable frequency value ±1%  
VD interval(T): 262.5H or more (XC-ST50/ST30), 312.5H or more (XC-ST50CE/30CE) and 1 second or less (Recommended)  
Four or more VD pulses are required.  
T
1/60 second  
1/60 second  
Exposure time for Odd field  
Exposure time for Even field  
Video output  
Odd image  
Even image  
Invalid image  
Valid frame image  
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.  
11  
XC-ST50/50CE  
XC-ST30/30CE  
FRAME IMAGE OUTPUT WITH STROBE LIGHT  
A full frame image with vertical resolution of 485 lines (XC-ST50/ST30) or 575 lines (XC-ST50CE/ST30CE) can be  
obtained with a strobe light by firing the strobe when the exposure time of the two fields overlap.  
Timing and conditions  
<Timing chart by restart/reset>  
EXT HD  
Continuous signal: 15.734 kHz (XC-ST50/ST30), 15.625 kHz (XC-ST50CE/30CE) Allowable frequency value ±1%  
EXT VD  
VD: XC-ST50/ST30 (1/60 sec), XC-ST50CE/30CE (1/50 sec) Four or more VD pulses are required.  
Strobe light  
Exposure time for Odd field  
Exposure time for Even field  
Video output  
Odd image  
Even image  
Invalid image  
Valid frame image  
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.  
Avoid lighting the scene during the light-emitting inhibit zone defined below. (The field is transfered to the  
storage area of the CCD, so it can be read out.)  
Note  
: For best performance, it is recommended not to flash between VD and VD + 10H (XC-ST50/ST30)/  
16H (XC-ST50CE/ST30CE).  
12  
XC-ST50/50CE  
XC-ST30/30CE  
OUTPUT WAVEFORM TIMING CHART (XC-ST50 (EIA)/XC-ST30 (EIA))  
Timing chart of horizontal output waveform  
HD  
91 (6.36 µs)  
40  
77  
22  
3
15  
752  
CCD  
output  
signal  
Effective total pixel 768  
Dummy  
pixel  
69.8 ns  
Optical black  
portion  
Horizontal transfer stop period  
Optical black portion  
Horizontal blanking period (11.0  
µs)  
Output video period  
Camera video  
output signal  
(Typical value)  
67 (4.68  
µs)  
752 (52.5 µs)  
21 HSYNC  
(1.47 µs) 70  
(4.89 µs)  
One horizontal scanning period (1 H)  
910 (63.56 s)  
µ
Timing chart of vertical output waveform (2:1 interlaced frame integration)  
Odd field (262.5 H)  
Even field (262.5 H)  
VD  
9 H  
253.5 H  
9 H  
253.5 H  
2 4 6 8  
1 3 5 7 9  
CCD  
output  
signal  
1
8
6
4
242.5  
2
8
6
3.5  
242.5  
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (20 H)  
Vertical blanking  
period (20 H)  
13  
XC-ST50/50CE  
XC-ST30/30CE  
OUTPUTWAVEFORMTIMING CHART (XC-ST50 (EIA)/XC-ST30 (EIA))  
Timing chart of vertical output waveform (2:1 interlaced field integration)  
Odd field (262.5 H)  
Even field (262.5 H)  
VD  
9 H  
253.5 H  
9 H  
253.5 H  
CCD  
output  
signal  
1
8
6
4
242.5  
1
8
6
3.5  
242.5  
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (20 H)  
Vertical blanking  
period (20 H)  
xc  
14  
XC-ST50/50CE  
XC-ST30/30CE  
OUTPUT WAVEFORM TIMING CHART (XC-ST50CE (CCIR)/XC-ST30CE (CCIR))  
Timing chart of horizontal output waveform  
HD  
98  
(6.91 µs)  
40  
91  
22  
3
15  
736  
CCD  
output  
signal  
Effective total pixel 752  
Output video period  
Dummy  
pixel  
70.5 ns  
Optical black  
portion  
Horizontal transfer stop period  
Optical black portion  
Horizontal blanking period (12.1 µs)  
Camera video  
output signal  
(Typical value)  
81 (5.71 µs)  
736 (51.9 µs)  
21 HSYNC  
s) 70  
(4.93  
(1.48  
µ
µ
s)  
One horizontal scanning period (1 H)  
908 (64.0 µs)  
Timing chart of vertical output waveform (2:1 interlaced frame integration)  
Odd field (312.5 H)  
Even field (312.5 H)  
VD  
7.5 H  
305 H  
7.5 H  
305 H  
1 3 5 7 9  
2 4 6 8  
CCD  
output  
signal  
287.5  
287.5  
1
14  
6
3.5  
2
14  
6
3
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (25 H)  
Vertical blanking  
period (25 H)  
15  
XC-ST50/50CE  
XC-ST30/30CE  
OUTPUTWAVEFORMTIMING CHART (XC-ST50CE (CCIR)/XC-ST30CE (CCIR))  
Timing chart of vertical output waveform (2:1 interlaced field integration)  
Odd field (312.5 H)  
Even field (312.5 H)  
VD  
7.5 H  
305 H  
7.5 H  
305 H  
CCD  
output  
signal  
287.5  
287.5  
1
14  
6
3.5  
1
14  
6
3
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (25 H)  
Vertical blanking  
period (25 H)  
16  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1  
(NON-RESET MODE)  
For setting the shutter speed using TRG width  
HD/VD input  
Continuous HD/VD input  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
External trigger shutter operation  
*
Normal operation  
1
2
3
1
*
Trigger  
1/3 s or more  
2
*
Exposure  
time Te  
2
2
*
Exposure time Te  
*
Exposure time Te  
1
1
*
External HD  
External VD  
*
(Continuous  
4
10 µs or more  
VD)  
EXT-VD  
*
T : T = Under 65 µs to under +10 µs  
4
*
T : T = Under 65 µs to under +10 µs  
+10 µs  
–65 µs  
1
2
3
Video out  
WEN  
5
*
250H (XC-ST50/30)  
293H (XC-ST50CE/30CE)  
TRG  
EXT-VD  
EXT-VD  
65 µs  
10 µs  
1: This is a signal input from the outside. Be sure to input both HD and VD signals in this case.  
*
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ST50/30)  
Te = Trigger width + 120 µs (XC-ST50CE/30CE)  
(The trigger width should be between 2 µs and 1/4 s)  
3: The normal operation state is engaged when the trigger high period exceeds 1/3sec.The external trigger  
shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the falling  
edge of a trigger pulse and the subsequent 50 ms period is an external trigger input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
*
*
*
4: In all cases the WEN signal indicates when a valid image is available. Normally, an image is output after  
the external falling edge. If the falling edge of the trigger is very close to the falling edge of the external VD,  
there may be a delay of 1VD in the output. The period of uncertainty is when the falling edge of VD is  
between 65 µs before or 10 µs after the falling edge of the trigger.  
5: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is  
output.  
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
17  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using TRG width  
HD/VD input  
Continuous HD input and single VD input  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
1
3
1
*
Trigger  
1/3 s or more  
2
*
Exposure  
time Te  
2
*
Exposure time Te  
1
1
*
External HD  
*
External VD  
(Single VD)  
4
min 10 µs  
*
T : T = 10 µs to 100 ms  
1
3
Video out  
WEN  
5
*
250H  
(XC-ST50/ST30)  
293H  
250H  
(XC-ST50/ST30)  
293H  
250H  
(XC-ST50/ST30)  
293H  
(XC-ST50CE/ST30CE) (XC-ST50CE/ST30CE)  
(XC-ST50CE/ST30CE)  
1: This is a signal input from the outside. Be sure to input both HD and VD signals in this case. Make the  
phase of the VD signal coincide with the falling edge of the HD signal during input operation.  
*
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ST50/ST30)  
Te = Trigger width + 120 µs (XC-ST50CE/ST30CE)  
(The trigger width should be between 2 µs and 1/4 s)  
3: The normal operation state is engaged when the trigger high period exceeds 1/3 sec.After that the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external trigger input inhibition area.  
During the trigger inhibit period, an input trigger may be missed.  
*
*
*
4: Be sure to input an external VD signal between 10 µs and 100 ms from the falling edge of a trigger pulse  
(as shown by 1 and 2 in the figure). For the input (except described above), the operation cannot be  
ensured. If the external VD signal is not input under the prescribed conditions, the normal operation is  
engaged several V after a change in input operation under the prescribed conditions.  
5: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is  
output.  
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
18  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using TRG width  
No HD/VD input (Internal synchronization)  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
External trigger shutter operation  
* Normal operation  
1
2
3
1
4
*
Trigger  
1/3 s or more  
2
2
2
*
Exposure  
time Te  
*
Exposure time Te  
*
Exposure time Te  
*
Interrnal VD  
5
5
*
T : T = 10 µs or more  
*
T : T = Under 10 µs  
1
2
3
Video out  
WEN  
6
*
250H (XC-ST50/ST30)  
293H (XC-ST50CE/ST30CE)  
1: This is a signal input from the outside.  
*
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ST50/ST30)  
Te = Trigger width + 120 µs (XC-ST50CE/ST30CE)  
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
*
4: An internal VD signal is output by setting the INT/EXT switch on the rear panel to INT.  
*
*
5: During external trigger shutter operation, an image is output when an internal VD signal falls after a trigger  
pulse falls (as shown by 1 and 2 in the figure). However, if the time (T in the figure) between the falling  
edges of a trigger pulse and internal VD signal is under 10 µs, an image is output when the internal VD  
signal or the next internal VD signal falls (as shown by 3 in the figure). (In this case, an image is output  
when the next internal VD signal falls.) An image and WEN signal are always output together. For more  
details, refer to the WEN signal. (The falling edge of an internal VD signal is the same in phase as the  
beginning of an equalizing pulse in a SYNC V area.)  
6: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is  
output.  
*
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
19  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using DIP switch  
HD/VD input  
Continuous HD/VD input  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
1/3 s or more  
1
2
3
1
*
Trigger  
100 µs to 250 ms  
2
*
Exposure  
time Te  
2
2
*
Exposure time Te  
* Exposure time Te  
1
1
*
External HD  
*
External VD  
(Continuous  
VD)  
4
4
4
*
T : T = Under 10 ms  
*
T : T = 10 ms or more  
*
T : T = 10 ms or  
more  
1
2
3
Video out  
WEN  
250H (XC-ST50/30)  
250H (XC-ST50/30)  
293H (XC-ST50CE/30CE) 293H (XC-ST50CE/30CE)  
1: This is a signal input from the outside.The period of a continuous VD signal is prescribed as one field. Be  
sure to input both HD and VD signals.  
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: An image is output when an external VD signal falls 10 ms or more after a trigger pulse rises (shown by 2  
and 3 in the figure). If the time (T in the figure) between the falling edges of a trigger pulse and external  
VD signal is under 10 ms, an image is output when the external VD signal or the next external VD signal  
falls (as shown by 1 in the figure). (In this case, an image is output when the next external VD signal falls.)  
An image and WEN signal are always output together. For more details, refer to the WEN signal.  
*
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
20  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using DIP switch  
HD/VD input  
Continuous HD input and single VD input  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
External trigger shutter operation  
*
Normal operation  
1/3 s or more  
1
3
1
100 us to 250 ms  
*
Trigger  
2
*
Exposure  
time Te  
2
*
Exposure time Te  
1
1
*
External HD  
*
External VD  
(Single VD)  
min. 10 ms  
4
*
T : T = 10 ms to 110 ms  
1
2
Video out  
WEN  
250H  
250H  
(XC-ST50/30)  
293H  
(XC-ST50/30)  
293H  
(XC-ST50CE/30CE)  
(XC-ST50CE/30CE)  
1: This is a signal input from the outside. Be sure to input both HD andVD signals. Make the phase of theVD  
signal coincide with the falling edge of the HD signal.  
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: Be sure to input an externalVD signal for 10 ms to 110 ms from the rising edge of a trigger pulse (as shown  
by 1 and 2 in the figure). For the input except described above, the operation cannot be ensured. If the  
external VD signal is not input under the prescribed conditions, the normal operation is engaged several V  
after a change in input operation under the prescribed conditions.  
*
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
21  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using DIP switch  
No HD/VD input (Internal synchronization)  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
1/3 s or more  
1
2
3
1
4
*
Trigger  
100 us to 250 ms  
2
2
2
*
Exposure time Te  
*
Exposure time Te  
*
Exposure  
time Te  
*
Interrnal VD  
5
*
T : T = 10 ms or  
more  
5
5
*
T : T = 10 ms or more  
*
T : T = Under 10 ms  
1
2
3
Video out  
WEN  
250H (XC-ST50/30)  
250H (XC-ST50/30)  
293H (XC-ST50CE/30CE) 293H (XC-ST50CE/30CE)  
1: This is a signal input from the outside.  
*
*
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: An internal VD signal is output by setting the INT/EXT switch on the rear panel to INT.  
*
*
5: An image is output when an internal VD signal falls 10 ms or more after a trigger pulse rises (as shown by  
2 and 3 in the figure). If the time (T in the figure) between the falling edges of a trigger pulse and internal  
VD signal is under 10 ms, an image is output when the internalVD signal or the nextinternalVD signal falls  
(as shown by 1 in the figure). In this case, an image is output when the next internal VD signal falls. An  
image and WEN signal are always output together. For more details, refer to the WEN signal. (The falling  
edge of an internal VD signal is the same in phase as the beginning of an equalizing pulse in a SYNC V  
area.)  
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
22  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2  
(RESET MODE)  
For setting the shutter speed using TRG width  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
1/3 s or more  
1
3
1
*
Trigger  
2
2
*
Exposure time Te  
*
Exposure  
time Te  
1
Video out  
WEN  
3
4
*
1H to 2H  
4
5
*
1H to 2H  
*
250H  
250H  
250H  
(XC-ST50/30)  
293H  
(XC-ST50/30)  
293H  
(XC-ST50/30)  
293H  
(XC-ST50CE/30CE)  
(XC-ST50CE/30CE)  
(XC-ST50CE/30CE)  
1: This is a signal input from the outside. The trigger interval should be trigger pulse width + 1 field + 2H  
period or more. The trigger interval shorter than described above cannot be ensured. If a trigger pulse is  
not input under the prescribed conditions, the normal operation is ensured several V after a change in  
input operation under the prescribed conditions.  
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ST50/ST30),  
Te = Trigger width + 120 µs (XC-ST50CE/ST30CE)  
*
*
(The trigger width should be between 2 µs and 1/4 s)  
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: A VD signal is generated 1H to 2H after a trigger pulse falls, and an image is output in synchronization with  
the VD signal.  
*
*
5: When the external trigger shutter mode changes into the normal operation mode, a WEN signal is output.  
23  
XC-ST50/50CE  
XC-ST30/30CE  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2 (RESET MODE)  
For setting the shutter speed using DIP switch  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
1/3 s or more  
1
3
1
*
Trigger  
100 us to 250 ms  
2
*
Exposure time Te  
2
*
Exposure  
time Te  
1
3
Video out  
WEN  
4
4
*
T
* T  
250H  
250H  
(XC-ST50/ST30)  
293H  
(XC-ST50/ST30)  
293H  
(XC-ST50CE/ST30CE)  
XC-ST50CE/ST30CE)  
1: This is a signal input from the outside. The trigger interval should be shutter speed (DIP switch) + 1 field  
+ 2H period or more. The trigger interval shorter than described above cannot be ensured. If a trigger  
pulse is not input under the prescribed conditions, the normal operation is engaged several V after a  
change in input operation under the prescribed conditions.  
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: After a period set by a DIP switch from the rising edge of the trigger, an image is output.  
*
24  
XC-ST50/50CE  
XC-ST30/30CE  
DIMENSIONS  
XC-ST50/50CE  
XC-ST30/30CE  
(XC-ST50 model)  
13  
2-M3 deep 4  
(Unit: mm)  
CCD  
VIDEO CAMERA MODULE  
XC-ST50  
(8)  
57.5  
65.5  
44  
4-M3 deep 4  
13  
50±0.5  
25  
XC-ST50/50CE  
XC-ST30/30CE  
SPECTRAL RESPONSE CHARACTERISTICS  
(TYPICAL VALUE)  
XC-ST50/ST30  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wavelength (nm)  
COMPARISON OF SPECTRAL RESPONSE CHARACTERISTICS  
(TYPICAL VALUE)  
XC-75/73 and XC-ST50/ST30  
1.0  
0.9  
0.8  
XC-ST50/30  
0.7  
0.6  
0.5  
XC-75/73  
0.4  
(without IR cut filter)  
0.3  
XC-75/73  
0.2  
(with IR cut filter)  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wavelength (nm)  
26  
XC-ST50/50CE  
XC-ST30/30CE  
VARIOUS LENS SELECTION  
The following shows the various lens specifications of the accessories available.  
XC-ST50/50CE and XC-ST30/30CE compatibility  
List of C-Mount Lens  
Model name  
Focal distance (mm)  
VLC-08YM  
8
VLC-12YM  
12  
VLC-16Y-M  
16  
VLC-25Y-M  
25  
VLC-50Y-M  
50  
1: 1.4  
1: 1.8  
1: 1.4  
1: 1.6  
1: 2.8  
Maximum aperture ratio  
Iris  
Manual  
Manual  
42.6˚×32.6˚  
32.6˚×24.8˚  
207  
Manual  
Manual  
29.6˚×22.4˚  
22.4˚×16.9˚  
208  
Manual  
Manual  
22.6˚×17.0˚  
17.0˚×12.8˚  
289  
Manual  
Manual  
14.6˚×11.0˚  
11.0˚×8.2˚  
204  
Manual  
Manual  
7.3˚×5.5˚  
5.5˚×4.1˚  
438  
Operation  
Focus  
Field angle  
1/2" CCD  
1/3" CCD  
(Horizontal x vertical)  
MOD (mm)  
XC-ST50  
181×132.8  
181.3×133.3  
136.8×100  
137×100.3  
11.54  
125.2×92.1  
125.5×92.5  
94.7×69.6  
94.8×69.6  
10.99  
119.4×88.5  
119.6×88.8  
90×66.8  
90.4×66.9  
12.5  
52.1×38.8  
52.1×38.9  
39.4×29.3  
39.4×29.3  
11.6  
49.2×37  
49.7×37.1  
37.2×27.9  
37.5×27.9  
22.1  
Image pickup range during  
maximum proximity  
(horizontal × vertical) (mm)  
XC-ST50CE  
XC-ST30  
XC-ST30CE  
Back focus (mm)  
Flange back (mm)  
Mass (g)  
17.526  
17.526  
17.526  
17.526  
17.526  
50  
40  
40  
50  
42  
MOD: Minimum object distance between the tip of the lens body and the object  
27  
XC-ST50/50CE  
XC-ST30/30CE  
Sony reserves the right to change specifications of the products and discontinue products without notice.  
Technical information contained herein is for reference only and does not convey any license by any implication or otherwise  
under any intellectual property right or other right of Sony or third parties.  
Sony cannot assume responsibility for any right infringements arising out of the use of this information.  
CCD B/W VIDEO  
CAMERA MODULE  
Sales Office :  
XC-ST50/50CE  
XC-ST30/30CE  
Japan  
Sony Corporation  
http://www.sony.co.jp/ISP/  
4-14-1 Asahi-cho,Atsugi-shi, Kanagawa,243-0014 Japan  
Tel: +81-46-227-2346  
Tel: +81-46-230-5873  
Fax: +81-46-227-2347  
Fax: +81-46-230-6243  
USA  
http://www.sony.com/professional  
Sony Electronics Inc.  
HQ  
1 Sony Drive Park Ridge, NJ 07656  
Tel: +1-800-686-7669  
Canada  
Sony of Canada Ltd.  
115 Gordon Baker Rd, Toronto, Ontario M2H 3R6  
Tel: +1-416-499-1414 Fax: +1-416-497-1774  
Europe  
http://www.pro.sony-europe.com/ISP  
Sony Broadcast & Professional  
HQ  
15, rue Floreal 75831 Paris Cedex 17, France  
Tel: +33-1-55-90-35-11  
Fax: +33-1-55-90-35-17  
Germany  
Hugo-Eckener-Str. 20, 50829 Koln  
Tel: +49-221-5966-322  
Fax: +49-221-5966-491  
France  
15, rue Floreal 75831 Paris Cedex 17  
Tel: +33-1-55-90-41-62  
Fax: +33-1-55-90-13-57  
UK  
The Heights, Brooklands, Weybridge, Surrey KT13 0XW  
Tel: +44-1932-816-340  
Nordic  
Fax: +44-1932-817011  
Per Albin Hanssons vag 20 S-214 32 Malmo Sweden  
Tel: +46-40-190-800  
Italy  
Fax : +46-40-190-450  
Via Galileo Galilei 40 I-20092 Cinisello Balsamo, Milano  
Tel: +39-02-618-38-431  
Fax : +39-02-618-38-402  
© 1999 Sony Corporation. All rights reserved.  
Reproduction in whole or in part without written permission is prohibited.  
00A  
http://www.sony.co.jp/ISP/  

相关型号:

XC-ST50/50CE

CCD B/W VIDEO CAMERA MODULE
SONY

XC-ST50CE

CCD B/W VIDEO CAMERA MODULE
SONY

XC0450A-03

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-03P

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-03S

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-05P

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-05S

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-10P

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-10S

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-20P

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-20S

Hybrid Coupler 3 dB, 90∑
ANAREN

XC0450A-30P

Hybrid Coupler 3 dB, 90∑
ANAREN