SC3E8-600H [SOCAY]
3-Electrode Gas Discharge Tube (GDT);型号: | SC3E8-600H |
厂家: | Socay Electornics Co., Ltd. |
描述: | 3-Electrode Gas Discharge Tube (GDT) |
文件: | 总5页 (文件大小:3426K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
3-Electrode Gas Discharge Tube (GDT)
SC3E8 Series
SC3E8-XXXHM
SC3E8-XXXHMF
Description
Gas discharge Tubes (GDT) are classical components for
protecting the installations of the telecommunications. It is
essential that IT and telecommunications systems -with their
high-grade but sensitive electronic circuits - be protected by
arresters. They are thus fitted at the input of the power supply
system together with varistors and at the connection points to
telecommunication lines. They have become equally indispensable
for protecting base stations in mobile telephone systems as well as
extensive cable television (CATV) networks with their repeaters
and distribution systems.
SC3E8-XXXHP
SC3E8-XXXH
These protective components are also indispensable in other
sectors, In AC power transmission systems, they are often used
with current-limiting varistors, In customer premises equipment
such as DSL modems, WLAN routers, TV sets and cable modems
In air-conditioning equipment, the integral black-box concept offers
graduated protection by combining arresters with varistors, PTC,
diodes and inductor.
Schematic Symbol
a = Tip
a
b
b = Ring
e = Ground
(center electrode)
Agency Approvals
AGENCY
Features
u
u
u
u
u
u
Non-Radioactive
RoHS compliant
Low insertion loss
Excellent response to fast rising transients
Ultra low capacitance
20KA surge capability tested with 8/20μs
pulse as defined by IEC 61000-4-5
Available with thermal failsafe option (add ‘F’ suffix to part
number)
AGENCY FILE NUMBER
E341061
Product Characteristics
Materials
Nickel-plated with Tinplated wires
u
SOCAY
XXXH
XXX -Nominal voltage
Product Marking
Applications
H
-20KA
u
u
u
u
u
u
u
u
u
u
u
Communication equipment
Glow to Arc
Transition Current
~1 Amps
~70 Volts
CATV equipment
Test equipment
Glow Voltage
Data lines
Storage and
Operational
Temperature
-40 to +90°C
Power supplies
Telecom SLIC protection
Broadband equipment
ADSL equipment, including ADSL2+
XDSL equipment
SC3E8-XXXHM
SC3E8-XXXHMF
SC3E8-XXXHP
SC3E8-XXXH
~2.0g
~2.3g
~2.1g
~1.8g
Weight
Satellite and CATV equipment
Consumer electronics
Climatic category
(IEC 60068-1)
40/ 90/ 21
SOCAY Electronics Corp., Ltd.
www.socay.com
@SOCAY Electronics Corp., Ltd. 2019
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Revision January 4, 2019
1 / 5
3-Electrode Gas Discharge Tube (GDT)
SC3E8 Series
Dimensions (Unit: mm)
Radial Leaded Devices (SC3E8-XXXHM)
Radial Leaded Devices with Fail-Safe (SC3E8-XXXHMF)
Without wire Devices (SC3E8-XXXH)
"T" Leaded Devices (SC3E8-XXXHP)
Electrical Characteristics
Service Life
Nominal
Alternating
Discharge
Current
Nominal
Impulse
Discharge
Current
DC Spark-over
Voltage
Maximum Impulse
Spark-over Voltage
Maximum
Arc
Max Impulse
Discharge
Current
Capacitance Voltage
Minimum
Insulation
Resistance
Impulse Life
Part Number
Marking
@50Hz 4)
1 Sec
@8/20μs 4)
±5 times
@8/20μs 4)
@10/1000μs 4)
@100V/S
@100V/μs @1KV/μs
@1MHz
@1A
1 time
300 times
10 times
SC3E8-75HM
SC3E8-75HMF
SC3E8-75HP
SC3E8-75H
SOCAY
75H
1 GΩ
75V±20%
<500V <600V
<1.5pF
~15V
20KA
20KA
25KA
25KA
20A
20A
200A
200A
(at 25V)
SC3E8-90HM
SC3E8-90HMF
SC3E8-90HP
SC3E8-90H
SOCAY
90H
1 GΩ
90V±20%
<500V <600V
<1.5pF
~15V
(at 50V)
SOCAY Electronics Corp., Ltd.
www.socay.com
@SOCAY Electronics Corp., Ltd. 2019
Revision January 4, 2019
2 / 5
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
3-Electrode Gas Discharge Tube (GDT)
SC3E8 Series
Electrical Characteristics (Continue)
Service Life
Nominal
Nominal
Impulse
Discharge
Current
Maximum Impulse
Spark-over Voltage
DC Spark-over
Voltage
Maximum
Arc
Max Impulse
Discharge
Current
Alternating
Discharge
Current
Capacitance Voltage
Minimum
Insulation
Resistance
Impulse Life
Part Number
Marking
@50Hz 4)
1 Sec
@8/20μs 4)
±5 times
@8/20μs 4)
@10/1000μs 4)
@100V/S
@100V/μs @1KV/μs
@1MHz
@1A
1 time
300 times
10 times
SC3E8-150HM
SC3E8-150HMF
SC3E8-150HP
SC3E8-150H
SOCAY
150H
1 GΩ
150V±20%
<500V <600V
<1.5pF
~25V
20KA
20KA
20KA
20KA
20KA
20KA
20KA
20KA
20KA
25KA
25KA
25KA
25KA
25KA
25KA
25KA
25KA
25KA
20A
20A
20A
20A
20A
20A
20A
20A
20A
200A
200A
200A
200A
200A
200A
200A
200A
200A
(at 50V)
SC3E8-230HM
SC3E8-230HMF
SC3E8-230HP
SC3E8-230H
SOCAY
230H
1 GΩ
230V±20%
250V±20%
300V±20%
350V±20%
420V±20%
470V±20%
<600V <700V
<600V <700V
<800V <900V
<800V <900V
<900V <1000V
<900V <1000V
<1.5pF
<1.5pF
<1.5pF
<1.5pF
<1.5pF
<1.5pF
<1.5pF
<1.5pF
~25V
~25V
~25V
~25V
~25V
~25V
~25V
~25V
(at 100V)
SC3E8-250HM
SC3E8-250HMF
SC3E8-250HP
SC3E8-250H
SOCAY
250H
1 GΩ
(at 100V)
SC3E8-300HM
SC3E8-300HMF
SC3E8-300HP
SC3E8-300H
SOCAY
300H
1 GΩ
(at 100V)
SC3E8-350HM
SC3E8-350HMF
SC3E8-350HP
SC3E8-350H
SOCAY
350H
1 GΩ
(at 100V)
SC3E8-420HM
SC3E8-420HMF
SC3E8-420HP
SC3E8-420H
SOCAY
420H
1 GΩ
(at 100V)
SC3E8-470HM
SC3E8-470HMF
SC3E8-470HP
SC3E8-470H
SOCAY
470H
1 GΩ
(at 100V)
SC3E8-600HM
SC3E8-600HMF
SC3E8-600HP
SC3E8-600H
SOCAY
600H
1 GΩ
600V±20% <1100V <1200V
800V±20% <1200V <1400V
(at 100V)
SC3E8-800HM
SC3E8-800HMF
SC3E8-800HP
SC3E8-800H
SOCAY
800H
1 GΩ
(at 100V)
Notes:
1). Terms in accordance with ITU-T K.12 and GB/T 9043-2008
2). At delivery AQL 0.65 level Ⅱ, DIN ISO 2859
3). Tip or ring electrode to center electrode
4). Total current through center electrode, half value through tip respectively ring electrode
SOCAY Electronics Corp., Ltd.
www.socay.com
@SOCAY Electronics Corp., Ltd. 2019
Revision January 4, 2019
3 / 5
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
3-Electrode Gas Discharge Tube (GDT)
SC3E8 Series
Electrical Rating
Item
Test Condition / Description
Requirement
DC Spark-over Voltage
The voltage is measured with a slowly rate of rise dv / dt=100V/s
Impulse Spark-over
Voltage
The maximum impulse spark-over voltage is measured with a rise time of
dv / dt=100V//μs or 1KV/μs
The resistance of gas tube shall be measured each terminal each other terminal,
please see above spec.
Insulation Resistance
The capacitance of gas tube shall be measured each terminal to each other
terminal.
Capacitance
Test frequency :1MHz
The maximum current applying a waveform of 8/20μs that can be applied across
the terminals of the gas tube. One hour after the test is completed, re-testing of the
DC spark-over voltage does not exceed ±30% of the nominal DC spark-over
voltage. Dwell time between pulses is 3 minutes.
I
To meet
the specified
value
1.0
0.9
Nominal Impulse
Discharge Current
0.5
0.1
0.0
T
8μsec
20μsec
30% Max
Rated RMS value of AC current at 50Hz, 1 sec. 10 times. Intervals: 3min. The DC
spark-over voltage does not exceed ±30% of the nominal DC spark-over voltage.
IR > 108ohms.
Nominal Alternating
Discharge Current
Recommended Soldering Profile
Reflow soldering
Wave soldering
Soldering profile applied a single process
Soldering Parameters - Hand Soldering
Solder Iron Temperature: 350°C +/-5°C
Heating Time: 5 seconds max.
SOCAY Electronics Corp., Ltd.
www.socay.com
@SOCAY Electronics Corp., Ltd. 2019
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Revision January 4, 2019
4 / 5
3-Electrode Gas Discharge Tube (GDT)
SC3E8 Series
Part Numbering
S C 3 E 8 – X X X H M F
F,
with Fail-Safe
No, without Fail-Safe
M,
with wire
No, without wire
8/20μs Level
H, 20KA
Nominal DC Spark-over Voltage
75 = 75V
90 = 90V
150 = 150V
230 = 230V
350=350V
470=470V
600=600V
800=800V
Series
Packaging
Quantity
Part Number
Description
100PCS per Tray, 10 Trays / Inner Carton
100PCS per Tray, 10 Trays / Inner Carton
50PCS per Tray, 10 Trays / Inner Carton
100PCS per Tray, 10 Trays / Inner Carton
SC3E8-XXXHM
SC3E8-XXXHMF
SC3E8-XXXHP
SC3E8-XXXH
1000 PCS
1000 PCS
500 PCS
1000 PCS
Tray Dimension (Unit: mm)
Tray Dimension (Unit: mm)
Used in SC3E8-XXXHP
Used in SC3E8-XXXHM, SC3E8-XXXHMF, SC3E8-XXXH
Cautions and Warnings
u
u
u
Gas discharge tubes (GDT) must not be operated directly in power supply networks.
Gas discharge tubes (GDT) may become hot in case of longer periods of current stress (danger of burning).
Gas discharge tubes (GDT) may be used only within their specified values. In the event of overload, the head contacts may
fail or the component may be destroyed.
u
Damaged Gas discharge tubes (GDT) must not be re-used.
SOCAY Electronics Corp., Ltd.
www.socay.com
@SOCAY Electronics Corp., Ltd. 2019
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.
Revision January 4, 2019
5 / 5