MB115S36K [SLPOWER]

AC-DC Regulated Power Supply Module,;
MB115S36K
型号: MB115S36K
厂家: SL Power Electronics    SL Power Electronics
描述:

AC-DC Regulated Power Supply Module,

文件: 总8页 (文件大小:581K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MB115S  
115W Single Output  
LED Medical Series  
Features  
Small size of 2” x 4” x 1.3”  
For 1U Applications  
75W convection cooled  
115 Watts with 200 LFM  
Universal Input 90-264Vac  
Approved to UL/CSA/IEC/IEC60601-1, 3rd Edition  
Level V Efficiency Compliant  
-40˚C start up  
-20˚C to 70˚C Operating Temperature Range  
3 Year Warranty  
Optional LED indicator for power-on  
Description  
The MB115S LED with Medical Approval Series provide a reliable power source with high power density in 2” x  
4” x 1.3” package. Fully compliant to the applicable safety and Global Lighting EMC standards, these models  
will allow easy integration into many Lighting fixtures and other medical applications.  
Model Selection (only Highlighted ones require at this time)  
Model  
Output Current  
Output Current  
Forced air(200 LFM)  
(Total Power)  
9.00A  
Ripple &  
Total  
OVP  
Number  
MB115S12K  
Volts  
12 V  
Convection Cooled  
6.25 A  
Noise*  
0.5%RMS,  
1.5% pk-pk  
0.5%RMS,  
1% pk-pk  
0.5%RMS,  
1% pk-pk  
0.5%RMS,  
1% pk-pk  
0.5%RMS,  
1% pk-pk  
Regulation  
±2%  
Threshold  
14.0 ± 1.1V  
(108 Watts)  
4.58A  
(110 Watts)  
3.19A  
MB115S24K  
MB115S36K  
MB115S48K  
MB115S56K  
24 V  
36V  
3.13A  
2.08  
±2%  
±2%  
±2%  
±2%  
28.0 ± 2.5V  
42V± 4.0V  
55.0 ± 4.0V  
63.0 ± 4.0V  
48 V  
56 V  
1.56A  
1.34A  
2.40A  
(115 Watts)  
2.05A  
(115 Watts)  
Notes:  
* At -20C, the noise and ripple is 2% of the output.  
General & Input Specifications  
PARAMETER  
SPECIFICATION  
NOTES  
AC Input Voltage:  
90-264Vac, single phase  
AC Input Frequency:  
AC Input Current:  
Inrush Current:  
47-63Hz  
115Vac: 2A, 230Vac: 1A  
65A maximum @ 25C  
Earth Leakage Current  
<350uA@264Vac, 60 Hz input, NC  
(InputEarth):  
Input Fuse:  
F1:4A, 250VAC  
Fuse provided on all models  
www.slpower.com  
MB115S 25-AUG-16  
1
MB115S  
115W Single Output  
LED Medical Series  
Efficiency  
Typical  
Measured @ 25˚C  
MB115S12K  
MB115S24K  
MB115S36K  
MB115S48K  
MB115S56K  
89% @230V ac, full load  
89% @230V ac, full load  
89% @230V ac, full load  
90% @230V ac, full load  
90% @230V ac, full load  
86.5%@115V ac, full load  
87%@115V ac, full load  
87%@115V ac, full load  
88%@115V ac, full load  
88%@115V ac, full load  
-40˚C start up (full load)  
For 12V output, the maximum load is 75%  
Operating Temperature  
Storage Temperature  
-20˚C to 70˚C  
-40˚C to 85˚C  
<2 Seconds @115Vac(<3S for 12V  
output)  
<5 Seconds @115Vac for -20˚C ambient  
Turn-on Time:  
Hold-up Time:  
12mS minimum from loss of ac input at  
115 Vac  
DC Output Specifications  
PARAMETER  
SPECIFICATION  
NOTES  
Max of 75 Watts for Convection cooled  
Maximum 108 Watts for 12V output  
Output Power:  
Cooling:  
Max of 115 Watts for fan cooled  
(48 & 56V Models)  
-20 to 50˚C ambient  
Convection  
Forced Air of 200 LFM  
Total regulation is the maximum deviation from  
nominal voltage for all loading conditions  
Total Regulation:  
±2% for all models  
120% - 180% of rated output current  
value, Hiccup Mode  
Overload Protection:  
For 12V output, it is 110 to 180%  
Short Circuit  
Protection:  
Short across the output terminals will not  
cause damage to the unit. Hiccup Mode  
OVP firing reduces output voltage to  
<50% of nominal in <50mS. See chart for  
trip range  
Overvoltage  
Protection:  
Overtemperature  
Protection:  
Automatic Power Shutdown  
No minimum load is required  
Thermistor temperature is 130˚C  
Minimum Load:  
20 MHz Bandwidth, differential mode.  
Measured with noise probe directly across  
output terminals, and load terminated with  
0.1μF ceramic and 10μF low ESR capacitors  
0.5% RMS, 1% pk-pk for all models.  
Ripple and Noise:  
500s typ. response time for return to  
within 0.5% of final value for a 50% load  
change, i/t< 0.2A/s. Max. voltage  
deviation is 3.5%.  
Transient Response:  
Measured @ 25˚C  
5% overshoot at turn-on, 5% overshoot at  
turn-off, under all conditions.  
Overshoot:  
6% for 12V output  
www.slpower.com  
MB115S 25-AUG-16  
2
MB115S  
115W Single Output  
LED Medical Series  
Safety Standard Compliance  
Agency  
CONDITIONS  
UL  
EN/CSA/UL/IEC 60601-1 3rd Edition & EN60950  
CSA  
Same as above  
Demko  
Same as above  
Yes  
CB Report  
Isolation Type:  
Double/Reinforced between Input and Output  
Isolation Specifications  
PARAMETER  
CONDITIONS  
Rating  
NOTES  
Insulation Safety  
Rating:  
Basic Insulation  
Input to Ground  
Input to Output  
Input to Ground  
Input to Output  
Double/Reinforced  
2,000Vac  
Electric Strength Test  
Voltage:  
4,000Vac  
.
Output to Ground  
500Vac  
Environmental Specifications  
PARAMETER  
SPECIFICATION  
NOTES  
Operating  
Temperature:  
-20°C to +70°C  
-40°C Startup guaranteed  
60% derating at 70°C  
Convection/ Airflow  
Temperature Derating:  
Cooling:  
75 Watts convection  
Storage Temperature:  
-40°C to +85°C  
Operating: -500 to 3,000 meter  
Non-operating: -500 to 40,000 ft.  
5% to 95%, non-condensing  
Altitude:  
Relative Humidity:  
Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, 6  
shocks total  
Shock:  
Random vibration per MIL-STD-810E, Method  
514.4, Cat. 1, Figure 514.4-1, 1 hr in each of three  
axes  
Vibration:  
Reliability Specifications  
PARAMETER  
SPECIFICATION  
NOTES  
Calculation is done based on  
Telcordia. Reports for each  
model is available  
MTBF:  
574K hours, 25°C ambient, full load  
Warranty:  
3 Years  
Limited  
HALT Data:  
Per SL Power Halt procedure  
Report is available  
www.slpower.com  
MB115S 25-AUG-16  
3
MB115S  
115W Single Output  
LED Medical Series  
EMI/EMC Compliance  
PARAMETER  
SPECIFICATION  
NOTES  
Conducted Emissions:  
Radiated Emissions:  
EN55011/22 Class B; FCC Part 15  
Also meets EN55015 Class B  
EN55011/22 Class A; FCC Part 15  
EN61000-3-2, Class A,B,C &D  
Harmonic Current  
Emissions  
Meets class C from 5 to 115 Watts.  
This is based on limits set @ 115 Watt  
Voltage Fluctuations &  
Flicker  
EN61000-3-3  
Performance criteria are defined as  
following:  
Static Discharge  
Immunity:  
EN61000-4-2, Level 4: 6kV contact, 8kV air,  
Criteria A  
RF Field Susceptibility  
Fast Transients/Bursts  
EN61000-4-3, Level 3 (3V/m), Criteria A  
A Normal performance  
during and after the test  
B Temporary degradation,  
self-recoverable  
C Temporary degradation,  
operator intervention required  
to recover the operation  
EN61000-4-4, Level 3 (PS: 2kV-40A, other  
lines 1kV-20A), Criteria A  
EN61000-4-5, Installation Class 3 (1kV diff.  
mode, 2kV common mode), Criteria A  
Surge susceptibility  
Conducted RF  
susceptibility  
Power Frequency  
Magnetic Field Test  
EN61000-4-6, Level 3 (3Vrms), Criteria A  
EN61000-4-8, Level 3 (3A/m), Criteria A  
EN61000-4-11,  
95% dip/0.5 cycle (Criteria A),  
60%/5cycles (Criteria B), 30%/25 cycles  
(Criteria A).  
Voltage Sags & Surges  
loading is 70% of 100 watts with 100 Vac  
input.  
Notes:  
1. Specifications subject to change without notice.  
2. Specifications are for convection rating at factory settings with 115Vac input and 25°C ambient unless  
otherwise stated.  
Mechanical Drawing  
www.slpower.com  
MB115S 25-AUG-16  
4
MB115S  
115W Single Output  
LED Medical Series  
Connector Information  
Input Connector  
J2  
DC Output  
Connector  
J3  
Ground  
(FG)J1  
PIN 1) +Vout  
PIN 2) +Vout  
PIN 3) +Vout  
PIN 4) -Vout  
PIN 5) -Vout  
PIN 6) -Vout  
Mating Connector:  
AMP 640250-6  
Terminals :  
PIN 1) AC NEUTRAL  
PIN 2) EMPTY  
PIN 3) AC LINE  
19-30258-0187 (Keystone 1285)  
(Zierick 895)(.187*0.020)  
Mating Connector:  
Tyco/AMP 640250-3  
Terminals :  
Mating Connector  
Molex 190020005  
3-640252-1  
3-640252-1  
1. All dimensions in inches (mm) undefined tolerance is ±.02” (0.5mm).  
2. Mounting holes should be connected together for EMI purpose  
3. FG is safety ground connection  
4. This power supply requires mounting on metal standoffs 0.20” (5mm) Min. in height  
Characteristic Curves  
www.slpower.com  
MB115S 25-AUG-16  
5
MB115S  
115W Single Output  
LED Medical Series  
Output Power vs. Temperature  
Efficiency vs. Loading  
Ripple & Noise  
www.slpower.com  
MB115S 25-AUG-16  
6
MB115S  
115W Single Output  
LED Medical Series  
To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with  
0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW.  
Output Overload Characteristic  
Overvoltage Protection  
Turn On Time  
www.slpower.com  
MB115S 25-AUG-16  
7
MB115S  
115W Single Output  
LED Medical Series  
Hold Up Time  
CH1:  
CH3:  
Vout  
Vin:  
Iout:  
115  
2.40  
23.2  
Vac  
Vin  
16  
Amps  
mS  
Min_Limit:  
Meas:  
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for  
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.  
www.slpower.com  
MB115S 25-AUG-16  
8

相关型号:

MB11A

MIL Series Connector, Aluminum Alloy, Female; Male, Crimp Terminal, Receptacle
AMPHENOL

MB11A01V05

Bridge Rectifier Diode, 1.5A, 50V V(RRM),
POWEREX

MB11A01V40

Bridge Rectifier Diode, 1.5A, 400V V(RRM),
POWEREX

MB11A01V60

Bridge Rectifier Diode, 1.5A, 600V V(RRM),
POWEREX

MB11A01W10

Bridge Rectifier Diode, 1.5A, 1000V V(RRM),
POWEREX

MB11A02V40

Bridge Rectifier Diode, 2A, 400V V(RRM),
POWEREX

MB11A06V05

Bridge Rectifier Diode, 6A, 50V V(RRM),
POWEREX

MB11A06V10

Bridge Rectifier Diode, 6A, 100V V(RRM),
POWEREX

MB11A06V40

Bridge Rectifier Diode, 6A, 400V V(RRM),
POWEREX

MB11A06V60

Bridge Rectifier Diode, 6A, 600V V(RRM),
POWEREX

MB11A06W10

Bridge Rectifier Diode, 6A, 1000V V(RRM),
POWEREX

MB11A10-6P

MIL Series Connector, 6 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle
AMPHENOL