CINT1150A4806K01 [SLPOWER]
The CINT1150 family is the latest offering in high density single output open-frame AC/DC power supplies.; 该CINT1150系列是最新推出的高密度单输出开架式AC / DC电源。型号: | CINT1150A4806K01 |
厂家: | SL Power Electronics |
描述: | The CINT1150 family is the latest offering in high density single output open-frame AC/DC power supplies. |
文件: | 总8页 (文件大小:636K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CINT1150
150W Single Output
Industrial Series
Features
.
.
.
.
.
.
.
.
2” x 4” x 1.3” Package
For 1U Applications
150W w/air, 100W convection cooled
Universal Input 90-264 VAC
Power Fail/Output Good Signal
Approved to CSA/EN/IEC/UL60950, 2nd Edition
3 Year Warranty
RoHS Compliant
Description
The CINT1150 family is the latest offering in high density single output open-frame AC/DC power supplies. Approved to
EN/IEC/UL60950-1, 2nd edition, the CINT1150 family is ideal for lighting, industrial printers, gaming equipment, and many
other applications where power density and cost are critical. The CINT1150 operates at universal input range of 90 to
264Vac and wide temperature range -10°C to +70°C, delivering full rated output power up to +50°C. In addition, these
models feature Power Fail and DC OK signals.
Model Selection
Model
Number
Output Current
Ripple &
Noise**
Total
Regulation
OVP
Threshold***
Volts
w/200LFM air
Convection*
CINT1150A1206K01
CINT1150A2406K01
CINT1150A4806K01
CINT1150A5606K01
12V
12.5A
6.25A
3.13A
2.68A
8.33A
0.5%RMS, 1.2% pk-pk
0.5%RMS, 1.0% pk-pk
0.5%RMS, 1.0% pk-pk
0.5%RMS, 1.0% pk-pk
5%
5%
5%
5%
14.0 1.1V
28.0 ± 2.5V
55.0 ± 4.0V
<59.9V
24V
48V
56V
4.17A
2.08A
1.79A
Notes:
*
Maximum output power is 95 Watts for input voltage of 90-105VAC at 50°C convection. For input voltage of 105Vac or more, the total power is
100 Watts at 50°C convection.
** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
General Specifications
Less than 2 sec. @115Vac (inversely
proportional to input voltage and thermistor
temperature)
100-240Vac, ±10%, 47-63Hz, 1
AC Input
Input Current
Inrush Current
Input Fuses
Turn On Time
Hold-up Time
Signals
120–370Vdc
115Vac: 2A, 230Vac: 1A
>12mS at full load, 120Vac
AC Power Fail, DC OK
Hiccup Mode
264Vac, cold start: will not exceed 50A
Overload
Protection
F1, F2: 4A, 250Vac fuses provided on all
models
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
1
CINT1150
150W Single Output
Industrial Series
General Specifications (continued)
Earth Leakage
<750μA@264Vac, 60Hz, NC
Current
Short Circuit
Protection
Provided - no damage will occur if the output
is shorted. Hiccup Mode
OVP firing reduces output voltage to <50%
of nominal in <50mS. See chart for trip
range.
Overvoltage
Protection
88% typical at 115Vac
Efficiency
150W continuous with 200 lfm airflow, 100W
convection cooled – See chart for specific
voltage model ratings.
PFC: Variable 30-400kHz.
Main Converter: Variable 35-180kHz, 65-
70kHz at full load.
Output Power
Switching Frequency
Isolation
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
Transient
Response
50% load step. i/t: <0.2A/μS
Max Volt Deviation = 3%
Operating
Temperature
See chart
-10°C to +70°C
Ripple and Noise
Output Voltage
Temperature
Derating
Derate output power linearly above 50°C to
50% at 70°C
See chart
Voltage
Adjustability
+/-5% from nominal
Not required
-40°C to +85°C
Storage Temperature
Altitude
Operating: -500 to 10,000 ft
Non-operating: -500 to 40,000 ft.
Minimum Load
+/- 5%. See chart
5% to 95%, non-condensing
Total Regulation
Relative Humidity
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall,
3 axes, 1 hr/axis
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
Vibration
Shock
W: 2.0” x L: 4.0” x H: 1.3”
183g
EN/CSA/UL/IEC60950-1, 2nd Edition
Dimensions
Weight
Safety Standards
MTBF
640,000 hours at 100W convection,
1,500,000 hours at 150W with 200LFM air
Auxiliary Signals
Goes LOW with 5 mS warning before loss
of output power due to AC failure
During normal operations, stays HIGH.
AC Power Fail:
Power Fail:
DC OK:
Open collector logic signal goes and stays HIGH
100mS to 500mS after main output reaches
regulation.
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
2
CINT1150
150W Single Output
Industrial Series
EMI/EMC Compliance
EN55011/22 Class B, FCC Part 15, Subpart B, Class B
Conducted Emissions
Radiated Emissions
EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin
EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m. Criteria A
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz, Criteria A
EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A
EN61000-4-6, 3Vrms, Criteria A
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
Line Harmonic Emissions
Flicker Test
EN61000-4-8, 3A/m, Criteria A
EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles;
Criteria A
EN61000-3-2, Class A, B, C, & D
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
3
CINT1150
150W Single Output
Industrial Series
Connector Information
Input Connector
J100
Ground
J101
DC Output Connector
J200
Signal Connector
J300
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
PIN 1) +Vout PIN 4) -Vout
PIN 2) +Vout PIN 5) -Vout
PIN 3) +Vout PIN 6) -Vout
PIN 1) PF/DC OK
PIN 2) Common
0.187” FASTON TAB
Mating Connector:
Molex 09-50-3031
Pins= 08-52-0072
Mating Connector:
AMP 640250-6
Pins = 640252-1
Mating Connector:
Molex 1375820-2
Pins = 1375819
Mating Connector:
Molex 01-90020009
Power Fail/DC OK Signals – J300
J300–Pin 1
J300 – Pin 2
AC POWER FAIL SIGNAL
DC OK SIGNAL
Isolation Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Input/Ground
Input/Output
Output/Ground
Basic
Reinforced
n/a
Insulation Safety Rating
Input/Ground
Input/Output
Output/Ground
1800
4000
500
Vac
Vac
Vac
Electric Strength Test Voltage
-
-
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
4
CINT1150
150W Single Output
Industrial Series
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Nom
Max
Units
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Input Frequency
90
115/230
82.7
67.0
50/60
-
264
Vac
Vac
Vac
Hz
Ramping up
Ramping down
47
-
63
50
-
Inrush Current Limitation
Power Factor
264Vac, cold start
A
Vi nom, Io nom
0.9
-
Vi nom, Io nom
CINT1150A1206K01
CINT1150A2406K01
CINT1150A4806K01
CINT1150A5606K01
Efficiency
88%
-
%
-
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted
Parameter
Input Fuse
Conditions/Description
Not user accessible
Min
Nom
Max
Units
Input Transient Protection
2KV(CM) and 1KV(DM) surge
2
KV (CM)
No-load
Short Circuit
Overload
Hiccup Mode
Hiccup Mode
Hiccup Mode
Output
Overvoltage Protection
Latch style
See Models chart for trip ranges
Over temperature Protection
Automatic power shutdown at TC =155°C
Characteristic Curves
Output vs. Temperature
100W convection cooled and 150W continuous with 200 LFM airflow, Derating output power to 50% at 70C.
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
5
CINT1150
150W Single Output
Industrial Series
Efficiency vs. Loading
The high efficiency is achieved by using LLC technology, PFC topology minimizing switching losses. Synchronous SCHOTTKY or ultra-fast diode is
used as rectifier in CINT1150 family because of high output voltage level.
Ripple & Noise
To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with
0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW.
24V OUT, NO LOAD, 90VAC, 60HZ
24V OUT, FULL LOAD, 90VAC, 60HZ
24V OUT, NO LOAD, 264VAC, 50HZ
CINT1150 REV 2.6, 12-NOV-12
24V OUT, FULL LOAD, 264VAC, 50HZ
www.slpower.com
6
CINT1150
150W Single Output
Industrial Series
Output Transient Response
50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/μSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY.
24V OUT, 120VAC, 25% TO 75% LOAD STEP
24V OUT, 240VAC, 25% TO 75% LOAD STEP
Output Overload Characteristic
Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention.
24V OUT, 90VAC
24V OUT, 264VAC
Short Circuit Protection
Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted..
24V OUT, 90VAC
24V OUT, 264VAC
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
7
CINT1150
150W Single Output
Industrial Series
Overvoltage Protection
OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges.
24V OUT, NO LOAD
24V OUT, FULL LOAD
Turn On Time
90VAC, FULL LOAD
264VAC, FULL LOAD
Hold Up Time
120VAC, FULL LOAD
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
8
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明