Rated
Peak
60W
84W
General Purpose
SNP-GK6 Series
Features:
●ꢀ
Peak load (1.4 ~ 2 x rated current, Vo=rated for 5 sec)
Design for BF application
Convection cooling for Rated power
Built-in PFC and 12V output for fan, available for
G12x, G16x, and G20x
●ꢀ
●ꢀ
●ꢀ
●ꢀ
●ꢀ
EMI class B
-20oC to +70oC operating temperature
Applications:
●ꢀ
For peak load and surge load applications, such as mo-
tor drive, coffee machine, vending machine, gaming
machine, and other industrials.
For EMI class B application, such as home healthcare
2" x 4" x 0.97"
●ꢀ
device, and other medical devices.
General Specifications:
Input voltage ......................................... 90 VAC to 264 VAC
Input frequency ............................................. 47 Hz to 63 Hz
No load input power .................................................. < 0.5W
Inrush current ............................................ < 30A at 115VAC
Over voltage protection ............................................ latch off
Operating temperature (open frame type) ........ -20oC to 70oC
derating: 2.5% / oC > 50oC
Cooling ............................................ 60W free air convection
Storage temperature ...................................... -40oC to +85oC
EMI .......................................... EN55022 "B", EN61000-3-3
Harmonics............................................. EN61000-3-2 class A
EMS....................................... EN61000-4-2,-3,-4,-5,-6,-8,-11
Safety ..................................UL/CSA/EN60950-1, 2nd edition
ANSI/AMMI/CSA/EN60601-1, 3rd edition
(cold start at 25oC)
or < 60A at 230VAC
Efficiency .............................. 85%~89% depends on models
Hold up time .....................................................16 ms typical
at rated load and 115VAC
Over load protection ........................................ auto recovery
Short circuit protection..................................... auto recovery
Mechanical Specifications:
Ø3.2 TYP. MOUNTING HOLES
Notes:
1. Size:
x4
101.6 (4")
2" x 4" x 0.97"
TB1
L
2. Mounting Hole:
44.5 x 95.3 (mm)
3. Connectors:
TB2
N
50.8
(2")
TRANSFORMER
AC input: Molex 5277-02A or equivalent
DC output: Molex 5273-04A or equivalent
4. Output Pin assignment:
44.5
1
2
3
4
3.15
95.3
Vo
Vo
GND GND
3.15
5. Packing:
Net weight: 110 g approx. / unit
Gross weight: 14 kg approx. / carton, 100 units / carton
Carton size (mm): 420 (L) x 382 (W) x 277 (H)
max.
(0.97")
24.6
2.4 max. (3.0 Max. for SMD components)
-Clark-
10 years Warranty (contact Skynet's Distributors for details)
** This data sheet is only for models selection. For business, engineering specification by model must be used.
OCT. 2017
4-1
Rated
Peak
60W
84W
General Purpose
SNP-GK6 Series
Output Specifications:
PRODUCT
NO.
OUTPUT
RAIL
LOAD
VOLTAGE
RIPPLE
NOISE
LINE
REG.
LOAD
REG.
ACCURACY
MIN.
RATED MAX.
PEAK
SNP-GK67
SNP-GK67 -M
SNP-GK67 -MH
+12V
+15V
+18V
+24V
+28V
+36V
+48V
+60V
0A 5.00A
0A 4.00A
0A 3.33A
0A 2.50A
0A 2.14A
0A 1.66A
0A 1.25A
0A 1.00A
6.50A
+11.9V~+12.1V
+14.9V~+15.1V
+17.9V~+18.1V
+23.9V~+24.1V
+27.9V~+28.1V
+35.8V~+36.2V
+47.8V~+48.2V
+59.6V~+60.4V
120mVpp
100mVpp
150mVpp
150mVpp
150mVpp
200mVpp
250mVpp
300mVpp
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
SNP-GK68
SNP-GK68 -M
SNP-GK68 -MH
5.60A
4.67A
3.50A
3.00A
2.21A
1.75A
1.40A
SNP-GK65
SNP-GK65 -M
SNP-GK65 -MH
SNP-GK69
SNP-GK69 -M
SNP-GK69 -MH
SNP-GK6G
SNP-GK6G-M
SNP-GK6G-MH
SNP-GK6J
SNP-GK6J -M
SNP-GK6J -MH
SNP-GK6T
SNP-GK6T-M
SNP-GK6T-MH
SNP-GK6H
SNP-GK6H-M
SNP-GK6H-MH
Note:
1. Standby Power Cosumption with System:
For computers and displays, ENERGY STAR in U.S. and ErP regulation in Europe require the input power should be less than 0.5W at standby mode.
2. Peak Load Duration:
Peak load can last for 5 sec.
3. Isolation Grade:
Primary
Primary
Secondary
Ground
: 1MOPP (1500Vac)
Secondary : 2MOPP (4000Vac)
Ground : 1MOPP (1500Vac)
←→
←→
←→
4. Leakage Current:
Earth leakage current < 300uA
Touch current < 100uA
5. EMI Grounding:
If there is a metal sheet under the power supply, connect the EMI ground to the metal sheet.
6. Model Selection:
SNP-GK6x is for ITE application.
SNP-GK6x-M is for medical application.
SNP-GK6x-MH is for Home Healthcare application, input class II.
-Clark-
** This data sheet is only for models selection. For business, engineering specification by model must be used.
4-2
OCT. 2017
Rated
Peak
60W
84W
General Purpose
SNP-GK6 Series
Performance for SNP-GK67:
1. Switching frequency ripple
2. Line frequency ripple
+12V/5A
+12V/5A
100mV/div, 5us/div
100mV/div, 5ms/div
3. Output turn on wave form
4. Output turn off wave form
+12V/5A
+12V/5A
5.0V/div, 10ms/div
5.0V/div, 10ms/div
5. Hold-up time
6. Over voltage protection
Trip point around 16.4V
(60% Rated load)
5.0V/div
50V/div
Primary DC
10ms/div
5.0V/div, 10ms/div
-Clark-
** This data sheet is only for models selection. For business, engineering specification by model must be used.
OCT. 2017
4-3
Rated
Peak
60W
84W
General Purpose
SNP-GK6 Series
7. +12V step response
8. Start up time
AC: 100V
5.0V/div
+12V
+12V
Ac input
200V/div
200mV/div, 2ms/div
+12V step from 1A to 5A
0.1s/div
9. FCC B
10. EN55022 B
11. Power Derating Curve
-Clark-
** This data sheet is only for models selection. For business, engineering specification by model must be used.