PE3100G2DQIR8-QS43 [SILICOM]
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter;型号: | PE3100G2DQIR8-QS43 |
厂家: | Silicom |
描述: | Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter PC |
文件: | 总12页 (文件大小:647K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
www.silicom-usa.com
PE3100G2DQIR8
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
Product Description
Silicom’s 100/40 Gigabit Ethernet PCI Express content
aware director server adapters is designed for servers and
high-end appliances. The Silicom content aware director
server adapter is designed with an on board smart routing
architecture that enables packets to be redirected or
dropped based on defined rules.
The Silicom’s 100/40 Gigabit Ethernet content aware packet
director reduces host system process since only packets that are defined to be targeted to the host systems are
routed to the host; other packets can be routed to the other port or can be dropped by the content aware hardware
routing architecture.
The Silicom’s 100/40 Gigabit Ethernet content aware packet director is targeted to network applications that needs to
process, monitor or bypass packets based on defined rules. The adapter supports three main modes of operation:
Content Aware Bypass, Content Aware TAP and content Aware filtering NIC.
Content Aware Bypass
Silicom’s 100/40 Gigabit Ethernet content aware director
provides intelligent packet redirection capability where rules
specify which packets are directed to the host system and
which packets are directed to the other port (Bypass).
Content Aware TAP
Silicom’s 100/40 Gigabit Ethernet content aware director
provides intelligent packet redirection capability where all
packets are directed to the other port (Bypassed) and rules
specify which packets are copied to the host system ( TAP).
Content Aware Filtering NIC
Silicom’s 100/40 Gigabit Ethernet content aware provides
intelligent packet redirection capability where rules specify which packets are directed to the host or dropped.
The Silicom 100/40 Gigabit Ethernet PCI Express content director server adapter is based on Intel FM10840 Ethernet
controller and a L3 switch router. The Silicom’s 40 Gigabit Ethernet PCI Express adapter is based on standard L2
driver and with the content director engine reduces CPU host system processing.
1Page
Silicom Ltd. Connectivity Solutions
The Silicom 100/40 Gigabit Ethernet PCI Express content aware server adapter offers simple integration into any PCI
Express X16 to 100Gigabit Network.
Key Features
Content Aware Director:
Provides intelligent packet redirection capability where rules specify which packets are directed to the host system
and which packets are directed to the other port (Bypass).
Provides intelligent packet redirection capability where all packets are directed to the other port (Bypassed) and
rules that specify which packets are copied to the host system (TAP).
Provides intelligent packet filtering / drop capability where rules specify which packets are directed to the host or
dropped.
Provides redirection rules that can be defined using source IP/ destination IP / Source Port / Destination Port /
VLAN tuples.
Redirection and packet filtering / drop are performed by the hardware itself in wire speed and do not require any
software and CPU host system power processing.
Intelligent redirect mechanism is controllable via software.
Intelligent routing mechanism is controllable via software.
Support 2x100G / QSFP28 ports.
100G QSFP28 Ports support 100GBase-SR4 and 100GBase-LR4.
40G QSFP28 Ports support 40GBase-SR4 and 40GBase-LR4.
Common Key features:
Host Interface:
PCI Express X16 lane
Support PCI Express Base Specification Revision 3.0, 8GT/s, 5GT/s or 2.5GT/s
Intel FM10840 Features:
Single-element 4MB shared memory
L2/L3/L4/OpenFlow forwarding & ACLs
Stateless load balancing to CPUs
Datacenter Bridging (lossless Ethernet)
32K 40-bit TCAM entries
16K MAC & NextHop tables
Up to 300Gbps High-bandwidth CPU interface
2x 50Gbps 8-lane PCIe interfaces
Up to 8 25G/10G/2.5G/1G ports
Up to 2 40G (4 x 10G)
2Page
Silicom Ltd. Connectivity Solutions
Up to 2 100G (4 x 25G)
300ns network latency (100GbE)
1000nS host-network latency
LAN Features:
256 queues per PCIe x16 interface
SR-IOV (64 VFs per PCIe x16 interface)
IP/TCP/UDP checksum
Receive side scaling (RSS)
TCP segmentation offload (TSO/LSO)
LEDs indicator for link/Activity.
Technical Specifications
–QX4: QSFP+ 40Gigabit Ethernet Technical Specifications Adapters:
QSFP+ ( Quad Small Form-
factor Pluggable) supports:
XLPPI interfaces supports 40GBase-R PCS and 40 Gigabit PMA in order to connect
with QSFP+ to 40GBase-SR4 / 40GBase-LR4
IEEE Standard / Network
topology:
Fiber 40Gigabit Ethernet, 40GBASE-SR4 (850nm LAN PHY).
with 40GBase-SR4 QSFP+
IEEE Standard / Network
topology:
Fiber 40Gigabit Ethernet, 40GBASE-LR4 (1310nm LAN PHY)
with 40GBase-LR4 QSFP+
-ZS4: Fiber 100GBASE-SR4 Ethernet Technical Specifications:
IEEE Standard / Network
Fiber Gigabit Ethernet, 100GBase-SR4 (850nM)
topology:
Data Transfer Rate:
103.125GBd
Cables and Operating
distance:
Multimode fiber:
62.5um, (OM4) 100m
Up to:
Typical: TBD dBm
Optical Output Power:
Minimum: TBD dB
* being defined by IEEE 802.3bm
3Page
Silicom Ltd. Connectivity Solutions
Typical: TBD dBm
Optical Receive Sensitivity:
Maximum: TBD dBm
* being defined by IEEE 802.3bm
– ZL4: Fiber 100GBASE-LR4 Ethernet Technical Specifications:
IEEE Standard / Network
Fiber 100Gigabit Ethernet, 100GBASE-LR4 (1310nM)
topology:
Data Transfer Rate:
103.1GBd
Cables and Operating
distance:
Single-Mode: 10km
Up to:
Typical: TBD dBm
Minimum: -4.3 dBm
Optical Output Power:
Typical: TBD dBm
Optical Receive Sensitivity:
Maximum: -10.6 dBm
– QS41: Fiber 40GBASE-SR4 Ethernet Technical Specifications:
Fiber 40Gigabit Ethernet, 40GBASE-SR4
IEEE Standard / Network
(840 to 860 nm LAN PHY).
topology:
IEEE 802.3ba
Data Transfer Rate:
10.5 GBd per lane
Cables and Operating
distance:
50um, (OM3) 1500 MHz*Km, 0.5 to 100 m
50um, (OM4) 3500 MHz*Km, 0.5 to 150 m
Maximum: 2.4 dBm per lane
Minimum: -7.6 dBm per lane
Output Transmit Power:
Optical Receive Sensitivity:
Maximum Input Power:
Minimum: -5.4 dBm
Maximum: 2.4 dBm
– QS43: Fiber 40GBASE-SR4 Ethernet Technical Specifications:
Fiber 40Gigabit Ethernet, 40GBASE-SR4
IEEE Standard / Network
(840 to 860 nm LAN PHY).
topology:
IEEE 802.3ba
4Page
Silicom Ltd. Connectivity Solutions
Data Transfer Rate:
10.5 GBd per lane
Cables and Operating
distance:
50um, (OM3) 1500 MHz*Km, 0.5 to 300 m
50um, (OM4) 3500 MHz*Km, 0.5 to 400 m
Maximum: 0.5 dBm per lane
Minimum: -7.5 dBm per lane
Output Transmit Power:
Optical Receive Sensitivity:
Maximum Input Power:
Minimum -7.5dBm
Maximum: 2.4 dBm
– QL4: Fiber 40GBASE-LR4 Ethernet Technical Specifications:
Fiber 40Gigabit Ethernet, 40GBASE-LR4
(1264.5nm – 1277.5nm ;
IEEE Standard / Network
topology:
1284.5nm – 1297.5nm ;
1304.5nm – 1317.5nm ;
1324.5nm – 1337.5nm LAN PHY).
IEEE 802.3ba
Data Transfer Rate:
10.3125 GBd per lane
SMF-28, 10Km
Cables and Operating
distance:
Maximum: 2.3 dBm per lane
Minimum: -7.0dBm per lane
Output Transmit Power:
Optical Receive Sensitivity:
Maximum Input Power:
Maximum: -9.6 dBm
Maximum: 2.3 dBm
Operating Systems Support:
Operating system support:
Linux
General Technical Specifications:
Interface Standard:
Board Size:
PCI-Express Base Specification Revision 3.0(8 GTs)
Standard height long add-in card 203.2mm X 111.15mm (8”X 4.376”)
PCI Express Card Type:
5Page
X16 Lane
Silicom Ltd. Connectivity Solutions
PCI Express Voltage:
+12V ± 8%
+12V ± 8%
External Voltage from
external PW jack:
PCI Connector:
Controller:
Gold Finger: X16 Lane
Intel FM10840
Holder:
Metal Bracket
Operating Humidity:
Operating Temperature:
Storage:
0%–90%, non-condensing
0°C – 40°C (32°F – 104F), Air flow requirement 200FLM
-40°C–65°C (-40°F–149°F)
Regulation:
Card shall meet CE, FCC Class B, ROHS requirements.
* The prediction was performed for 40°C Ambient temperature, GB Environmental
condition.
MTBF*:
The reliability prediction was performed in accordance with Telcordia SR-332.
-LEDs/ Connectors Specifications:
Four LEDs per port
(1) Link/Act 100/25/10Gbps LED:
Turns on – link, Blink – ACT
100Gbps(Yellow)
25Gbps(Orange)
10Gbps(Blue)
(1) Link/Act 40/25/10Gbps LED:
Turns on – link, Blink – ACT
40Gbps(Yellow)
LEDs:
25Gbps(Orange)
10Gbps(Blue)
(2) Link/Act 25/10Gbps LEDs:
Turns on – link, Blink – ACT
25Gbps(Orange)
10Gbps(Blue)
LEDs location:
LEDs are located on the PCB, visible by light quide in the metal bracket.
(2) MPO/LC
Connector:
6Page
Silicom Ltd. Connectivity Solutions
Functional Description
Director Director – Content Aware Bypass
Silicom’s 100 Gigabit Ethernet content aware director Provides intelligent packet redirection capability where rules
specify which packets are directed to the host system and which packets are directed to the other port (Bypass).
Figure 1: Content Aware Bypass Functional Block Diagram
Figure 1 Content Aware Bypass Functional Block Diagram
Figure 1 illustrates functional block diagram of content aware Bypass:
Packets received in port A and meet rule are directed to port B, other packets are directed to port C (Bypass).
Packets received in port C and meet rule are directed to port D, other packets are directed to port A (Bypass).
Director – Content Aware TAP
Silicom’s 100 Gigabit Ethernet content aware director Provides intelligent packet redirection capability where all
packets are directed to the other port (Bypassed) and rules specify which packets are copied to the host system
(TAP).
Figure 2: Content Aware TAP Functional Block Diagram
Figure 2 illustrates functional block diagram of content aware TAP:
Packets received in port A and meet rule are directed to ports B and C (TAP), other packets are directed to port C
(Bypass).
7Page
Silicom Ltd. Connectivity Solutions
Packets received in port C and meet rule are directed to ports D and A (TAP), other packets are directed to port A
(Bypass).
Director – Content Filtering NIC
Silicom’s 100 Gigabit Ethernet content aware provides intelligent packet redirection capability where rules specify
which packets are directed to the host or dropped.
Figure 3: Content Aware Filtering NIC Functional Block Diagram
Figure 3 illustrates functional block diagram of content aware TAP:
Packets received in port A and meet rule, direct to port B. Packets received in port A and do not meet rule are
dropped.
Packets received in port C and meet rule, direct to port D. Packets received in port C and do not meet rule are Dropt.
Director: Rules Classification and capabilities
The Redirector supports the following capabilities:
Maximum total number of rules is 16K.
Each of the 16K rules can be defined to any port the on board multi-layer switch.
Each rule refers to incoming packet
Rules are executed per order. First rule that matches will be executed
Rules can be added and removed on the fly.
Each rule can include one or more classification fields. A rule match will be when all fields defined are match.
Each field can have a bit masking to check part of the classification field.
Per port statistics can be read, like packets count, errors, VLAN, and more.
8Page
Silicom Ltd. Connectivity Solutions
Rules and action are done in wire speed at any packet size.
Rules classification fields
Rules classification is done based on the first 128 bytes of the packets. The following list provides rules classification
fields.
MAC address, source & destination
IPv4 – source & destination IP
IPv6 – source & destination IP
L4 Port – source & destination port
Ethernet Protocol – ethertype
IP Protocol num.
VLAN ID tagging
User defined fields
DSCP – match the different services code point – the six most significant bits of the Type of Service octet (IPv4) or
Traffic Class octet (IPv6).*
IPv6 Flow Label*
IP length*
ISL Frame Type*
ISL USER*
Source & destination port range*
VLAN priority*
VLAN tag type*
TCP flags*
TOS – match Type of Service octet (IPv4) or Traffic Class octet (IPv6)*
TTL field in a IPv4 header or Hop Limit in a IPv6 header*
*Future SW supports.
9Page
Silicom Ltd. Connectivity Solutions
Execution per rule
The following Executions per rule are supported:
Drop – when a rule matches the packet will be dropped
Redirect – when a rule matches redirect the packet to the defined destination port
Mirror – when a rule matches copy packet also to a defined destination port
Director Advanced Features:
Director Advanced features*
Port trunking between the Intel port to the Intel port connected to it for load balancing between the different Intel ports
Port trunking between the different External Intel port to the external switch connected to it for load balancing between
the different external ports.
Session balancing with L3/L4 hashing or other mechanism
ISL (Inter Switch Link) Tagging per port can be added to the packets per configuration
ISL Tagging can be removed and can be forward to specific port per the ISL index.
Quality of Service support with the following features:
Priority levels: 16 internal “switch” priorities, 8 or 16 VLAN priorities (optional use of CFI bit as an extra VLAN priority
bit)
Arbitrary mapping of ingress VLAN priority to an internal VLAN priority
Arbitrary mapping of an internal VLAN priority to egress VLAN priority
Arbitrary mapping of internal VLAN priority to switch priority
Arbitrary mapping of DSCP to switch priority, configurable priority source selection.
Scheduler: 8 traffic classes, arbitrary mapping of switch priorities to traffic class, deficit weighted round-robin or strict
priority.
Notification: Two congestion notifications can be supported;
Virtual output queue congestion notification (VCN) and Intel proprietary backward congestion notification (FCN).
10Page
Silicom Ltd. Connectivity Solutions
Open Flow support (consistent with OpenFlow protocol standard)
sFlow support
User defined Packet transmission with two optional modes: 1. Simple mode – transmit on specific port. 2. Switched
mode – where switch determines destination port/ports, or with specific information such as whether or not egress
processing rules should be applied.
Storm Control Management – Switch can support a variety storm controller. Each storm controller can be
programmable to define rat, condition (like unicast ICMP frames whose TTL is at most 1), frame type (can be OR’ed),
ingress & egress port ports. Actions: do nothing, drops frames to port (according to filter)
*Future SW supports.
Order Information
Thermal Sensing
Temp Sensor
Address
Thermal Diode and placement
D1 (Reg 0x25): Internal Diode on RRC (Tj)
Local (Reg 0x26): PS , back edge (Tj)
D2 (Reg 0x27): Internal Diode on PLX (Tj)
ADT7475
0101_110x
P/N
Description
Notes
Dual port Fiber (SR4) 100 Gigabit Ethernet
PCI Express Content Director Server
Adapter
RoHS Compliant,
X16 Gen 3,
PE3100G2DQIR8-ZS4
based on Intel FM10840
Dual port Fiber (LR4) 100 Gigabit Ethernet
PCI Express Content Director Server
Adapter
RoHS Compliant,
X16 Gen 3,
PE3100G2DQIR8-ZL4
PE3100G2DQIR8-QS41
based on Intel FM10840
RoHS Compliant,
Dual port Fiber (SR4) 40 Gigabit Ethernet
PCI Express Content Director Server
Adapter
X16 Gen 3,
based on Intel FM10840,
on board support for Fiber SR4 up to
length 100m on OM3 MMF
11Page
Silicom Ltd. Connectivity Solutions
RoHS Compliant,
Dual port Fiber (SR4) 40 Gigabit Ethernet
PCI Express Content Director Server
Adapter
X16 Gen 3,
PE3100G2DQIR8-QS43
based on Intel FM10840,
on board support for Fiber SR4 300m on
OM3 MMF
RoHS Compliant,
Dual port Fiber (LR4) 40 Gigabit Ethernet
PCI Express Content Director Server
Adapter
X16 Gen 3,
PE3100G2DQIR8-QL4
PE3100G2DQIR8-Qx4
based on Intel FM10840,
on board support for Fiber LR4
RoHS Compliant,
Dual port Fiber (LR4) 40 Gigabit Ethernet
PCI Express Content Director Server
Adapter
X16 Gen 3,
based on Intel FM10840,
on board support for QSFP+
1V3
12Page
Silicom Ltd. Connectivity Solutions
相关型号:
PE3100G2DQIR8-QX4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIR8-ZL4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIR8-ZS4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL-QL4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL-QS41
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL-QS43
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL-QX4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL-ZL4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRL-ZS4
Dual port Fiber 100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRM
Dual port Fiber 40/100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
PE3100G2DQIRM-QL4
Dual port Fiber 40/100 Gigabit Ethernet PCI Express Content Director Server Adapter
SILICOM
©2020 ICPDF网 联系我们和版权申明