AODG-P1 [SICK]
DISPLACEMENT MEASUREMENT SENSORS;![AODG-P1](http://pdffile.icpdf.com/pdf2/p00345/img/icpdf/AODG-N1_2128157_icpdf.jpg)
型号: | AODG-P1 |
厂家: | ![]() |
描述: | DISPLACEMENT MEASUREMENT SENSORS |
文件: | 总7页 (文件大小:444K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
AODG-N1
OD Max
DISPLACEMENT MEASUREMENT SENSORS
AODG-N1 | OD Max
DISPLACEMENT MEASUREMENT SENSORS
Ordering information
A
B
C
D
E
F
Type
Part no.
AODG-N1
6030979
Other models and accessories www.sick.com/OD_Max
Detailed technical data
Features
Amplifier unit
System part
Performance
0.5 ms 1)
10 kHz
Response time
Measuring frequency
Output time
≤ 0.1 ms
Arithmetic calculations, Mean-value setting 1 … 4,096x, Frequency filters, automatic sensitivity
adjustment, manual sensitivity adjustment, Time functions, 8 memory banks, Hold functions,
Peak-to-peak measurement, Peak height measurement, Bottom measurement, Analog outputs
can be taught in, Switching outputs can be taught in, set hysteresis, Internal data recorder,
switching mode: distance to object (DtO), switching mode: window (Wnd)
Additional function
H
I
Required for OD25-01T1
Note
1)
J
Automatic sensitivity adjustment ≤ 2 ms.
Interfaces
2 x –5 ... +5 V (≥ 1 kΩ) 1) 2 x 4 mA ... 20 mA (≤ 300 Ω) 1)
16 bit
Analog output
K
L
Resolution analog output
Switching output
5 x NPN (100 mA) 2)
2 x alarm
Error output (max. output current)
Reference input
2 x zero-ref
M
N
O
P
Q
R
S
T
3 x bank
Input for memory bank selection
Hold input
2 x hold, 1 x hold-reset
RS-232
Data interface
1)
Source of analog output is either sensor heads, or calculation result.
2)
PNP: HIGH = V - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = V .
S
S
Mechanics/electronics
DC 12 V ... 24 V 1)
Supply voltage Vs
6 W 2)
Power consumption
≤ 5 min
Warm-up time
Polycarbonat and nylon 66
Housing material
1)
DC 12 V (–5 %) ... DC 24 V (+10 %)
2)
When connected with two sensor heads, incl. analog current output.
Inclusive terminal board.
3)
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice
AODG-N1 | OD Max
DISPLACEMENT MEASUREMENT SENSORS
Terminal board
Connection type
Indication
1,4'' color display
240 g 3)
Weight
1)
DC 12 V (–5 %) ... DC 24 V (+10 %)
2)
When connected with two sensor heads, incl. analog current output.
Inclusive terminal board.
3)
Ambient data
IP 20
III
Enclosure rating
Protection class
Operation: –10 °C ... +45 °C
Storage: –20 °C ... +60 °C
Ambient temperature
35 % ... 85 %
Relative air humidity (non-condensing)
Vibration resistance
10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
50 G (x, y, z axis 3 times each)
Shock resistance
General notes
OD Max sensor head OD25-x is only to be used with AODG-P/N1; All other types (OD350-x,
OD85-x, OD30-x) are to be used with AOD-P/N1
Note on use
Dimensional drawing (Dimensions in mm (inch))
AOD-xx AODG-xx
47 (1.85)
103 (4.06)
2
1
3
3
14.7
(0.58)
7.7
(0.30)
65.4 (2.57)
22
(0.87)
27.4
(1.08)
4
5 6
① DIN rail mounting
② LC display
③ Terminal board (detachable)
④ RS-232C interface
⑤ Sensor head B connection port
⑥ Sensor head A connection port
2016-03-17 13:18:11 | Online data sheet
Subject to change without notice
DISTANCE SENSORS | SICK
3
AODG-N1 | OD Max
DISPLACEMENT MEASUREMENT SENSORS
Connection type
A
B
C
D
E
F
Evaluation unit RS-232C
Terminal block evaluation unit
L
R
Connection diagram
Terminal block connection diagram
L
H
I
1 GND
1 GND
1
1
4
4
5
2 12 V ... 24 V
3 JDGE 1
4 JDGE 2
5 JDGE 3
6 JDGE 4
7 JDGE 5
8 ALM A
2 ANG (V)
3 ANG (mA)
4 nc
2
2
2
2
2
3
3
4
4
1
5 BANK 0
6 BANK 1
7 BANK 2
8 HOLD A
9 RST
J
K
L
9 ALM B
10 ANG (V)
11 ANG (mA)
12 GND
10 HOLD B
11 ZERO A
12 ZERO B
R
M
N
O
P
Q
R
S
T
① Ground (0 V)
② Judgement Output = switching output
③ Alarm output
④ Analog output
⑤ Not assigned
4
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice
AODG-N1 | OD Max
DISPLACEMENT MEASUREMENT SENSORS
Evaluation unit RS-232C
1
nc
1
2
RXD
3
TXD
4
nc
1
5
GND
6
nc
1
7
nc
1
8
nc
1
9
nc
1
① Not assigned
Adjustment possible
AOD-xx AODG-xx
SELECT
7
1 2 3
SET/RUN
ADJUST MODE
BANK
ZERO
A
ZERO
B
LOCK
⑦ Operating elements
Recommended accessories
Other models and accessories www.sick.com/OD_Max
Brief description
Type
Part no.
Adapters and distributors
TERM.-AOD/AODG
6033129
Plug connectors and cables
Head A: female connector, M12, 10-pin, straight
Head B: male connector, M12, 10-pin, straight
Cable: unshielded, 2 m
DSL-1210-G02M
DSL-1210-G05M
6028943
6028944
Head A: female connector, M12, 10-pin, straight
Head B: male connector, M12, 10-pin, straight
Cable: unshielded, 5 m
2016-03-17 13:18:11 | Online data sheet
Subject to change without notice
DISTANCE SENSORS | SICK
5
AODG-N1 | OD Max
DISPLACEMENT MEASUREMENT SENSORS
Brief description
Type
Part no.
A
B
C
D
E
F
Head A: female connector, M12, 10-pin, straight
Head B: male connector, M12, 10-pin, straight
Cable: unshielded, 10 m
DSL-1210-G10M
6033614
H
I
J
K
L
M
N
O
P
Q
R
S
T
6
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice
相关型号: