1062992 [SICK]

PRESSURE SENSORS;
1062992
型号: 1062992
厂家: SICK AG    SICK AG
描述:

PRESSURE SENSORS

文件: 总6页 (文件大小:682K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PAC50-DCD  
PAC50  
PRESSURE SENSORS  
PAC50-DCD | PAC50  
PRESSURE SENSORS  
Ordering information  
A
B
C
D
E
F
Type  
Part no.  
PAC50-DCD  
1062992  
Other models and accessories www.sick.com/PAC50  
Illustration may differ  
H
I
Detailed technical data  
Features  
Dry compressed air  
Gauge pressure  
0 bar ... 10 bar  
0 °C ... +60 °C  
Medium  
Pressure type  
J
Measuring range  
Process temperature  
Analog signal output and ohmic load RA  
K
L
Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or  
programmable. Output signals can be inverted: 20 mA ... 4 mA / 10 V ... 0 V  
Load resistance for current output < 600 Ohm  
Load resistance with current output > 3 kOhm  
Max. + 5 % of span  
Zero point adjustment  
Output signal  
IO-Link/PNP + PNP/NPN/Push-Pull  
Switching output 2 can be set as diagnostics output  
M
N
O
P
Q
R
S
T
Diagnostics output  
Display  
LCD with LED backlight (green/red), can be rotated electronically by 180°  
Pressure display: 4 digits, 16 segments  
Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg  
Update: 1,000, 500, 200, 100 ms (adjustable)  
300 ms  
Initialization time  
Performance  
≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2  
Non-linearity  
Accuracy  
≤ ± 1.5 % of the span including non-linearity, hysteresis, zero point and full scale error (corre-  
sponds to error of measurement as per IEC 61298-2)  
≤ ± 0.2 % of span  
≤ ± 0.2 % of the span  
+10 °C ... +60 °C  
Setting accuracy of switching outputs  
Non-repeatability  
Rated temperature range  
2
FLUID SENSORS | SICK  
Online data sheet | 2016-03-19 00:51:29  
Subject to change without notice  
PAC50-DCD | PAC50  
PRESSURE SENSORS  
Mechanics/electronics  
1)  
Process connection  
PIF 4 mm + G ¼  
Housing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR  
17 V DC ... 30 V DC  
Housing material  
Supply voltage  
Max. 40 mA at L+ = 24 VDC  
Power consumption  
Protection class: III  
Electrical safety  
Overvoltage protection: 32 V DC  
Short-circuit protection: QA, Q1, Q2 towards M and L+  
Reverse polarity protection: L+ to M  
EMC directive: 2004/108/EC, EN 61326-2-3  
Approx. 40 g  
CE-conformity  
Weight sensor  
Enclosure rating  
IP 65 / IP 67 (according to IEC 60529) 2)  
Protection class III  
RoHS certificate  
CRUus certificate  
1)  
Bottom side: push-in fitting for 4 mm pneumatic hose, back side: thread G ¼ female according to DIN ISO 16030.  
When plugged in with a suitable mating connector.  
2)  
Ambient data  
0 °C ... +60 °C  
Ambient temperature  
Storage temperature  
Relative humidity  
Shock load  
–20 °C ... +80 °C  
≤ 90 %  
Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)  
Max. 5 g (10 ... 150 Hz), xyz, to DIN EN 60068-2-6  
Vibration load  
Dimensional drawing (Dimensions in mm (inch))  
Bottom side: push-in fitting for 4 mm pneumatic hose, back side: thread G ¼ female  
13.6  
(0.54)  
M12x1  
9.5  
(0.37)  
35  
(1.38)  
Push-in fitting  
ø 4.0 (ø 0.16)  
2016-03-19 00:51:29 | Online data sheet  
Subject to change without notice  
FLUID SENSORS | SICK  
3
PAC50-DCD | PAC50  
PRESSURE SENSORS  
Connection type  
A
B
C
D
E
F
M12 round connector x 1, 4-pin  
3
4
2
1
Output signals  
Type code  
Electrical  
Pin assignment  
connection  
M12 x 1, 4 pins  
M12 x 1, 4 pins  
M12 x 1, 4 pins  
2 x digital  
PAC50-xxA  
PAC50-xxB  
PAC50-xxD  
L+ = 1, M = 3, Q1 = 4, Q2 = 2  
L+ = 1, M = 3, Q1 = 4, QA = 2  
L+ = 1, M = 3, C/Q1 = 4, Q2 = 2  
1 x digital + analog  
1 x IO-Link/digital  
+ digital  
L+: Positive supply connection  
M: Negative supply connection  
Q1: Switching output 1  
C/Q1: With IO-Link: Communication/ switching output 1  
Q2: Switching output 2  
QA: Analog output  
H
I
Instruction for installation  
J
d
4
K
L
d
3
d
2
M
N
O
P
Q
R
S
T
a
1
Recommended accessories  
Other models and accessories www.sick.com/PAC50  
Brief description  
Type  
Part no.  
Mounting brackets and mounting plates  
4
FLUID SENSORS | SICK  
Online data sheet | 2016-03-19 00:51:29  
Subject to change without notice  
PAC50-DCD | PAC50  
PRESSURE SENSORS  
Brief description  
Type  
Part no.  
Wall-mounting kit; mounting element for wall-mounting of pressure switch PAC50,  
Mounting element: polycarbonate, screws: steel, zinc-coated  
BEF-MA-WLM-  
NTS-PAC5  
2069198  
Terminal and alignment brackets  
Switch panel installation kit, for installation of the PAC50 pressure switch in a switch  
panel. Maximum thickness of switch panel 5 mm., Panel-mounting frame and mounting  
element: polycarbonate, screws: steel, zinc-coated  
BEF-MA-  
CTRLPS-PAC5  
2069200  
6039728  
Modules and gateways  
Number of IO-Link ports: 4; Communication mode: COM1/COM2; IO-Link version: IO-  
Link V1.0; Switching input: PNP; Supply voltage Vs, IO-Link ports: DC 24 V; Current load-  
ing: 800 mA; Data transmission rate: Max. 12 MBaud, Autobaud; Address space occu-  
pation: 1 bis 126; Connection type: Connector M12; Connection type, IO-Link ports: Con-  
nector M12, 5-pin; Suppyl voltage Vs, module: DC 18 ... 30 V; Power consumption: Typ.  
75 mA / max. 100 mA (at UL with DC 24 V), Typ. 25 mA + sensor current / max. 80  
IOLSHPB-P3104R01  
2016-03-19 00:51:29 | Online data sheet  
Subject to change without notice  
FLUID SENSORS | SICK  
5

相关型号:

10631M/B2AJC

Dual D-Type Flip-Flop
ETC

1063260000

BHZ 5.00/02/90LH BK/OR
WEIDMULLER

1063280000

BHZ 5.00/04/90LH BK/OR
WEIDMULLER

10633024

SPOX 5/7.5 PITCH REC HSG
MOLEX

106397-1604

Fiber Optic Connector
MOLEX

106397-1862

Fiber Optic Connector,
MOLEX

106397-2202

Fiber Optic Connector
MOLEX

106397-2402

Fiber Optic Connector
MOLEX

106397-2427

Fiber Optic Connector
MOLEX

106397-3000

Fiber Optic Connector,
MOLEX

106397-3010

Fiber Optic Connector
MOLEX

1063971310

LC2 Connector, Singlemode, 125μm Ceramic PC Ferrule, 2.00mm Simplex Cable, Green Housing, Straight Boot
MOLEX