HMUM100 [SENSORTECHNICS]

Basic pressure sensors;
HMUM100
型号: HMUM100
厂家: SENSORTECHNICS GMBH    SENSORTECHNICS GMBH
描述:

Basic pressure sensors

文件: 总14页 (文件大小:357K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HMU Series  
Basic pressure sensors  
FEATURES  
· 100 mbar to 10 bar, 1 to 150 psi  
absolute, gage or differential pressure  
· Increased media compatibility1  
· Wide operating temperature range  
· SIL and DIP housings  
· RoHS compliant  
· Quality Management System according  
to ISO 13485:2003 and ISO 9001:2008  
MEDIA COMPATIBILITY1,2  
High pressure port: To be used with gases and  
liquidswhich are compatible with the wetted  
materials (high temperature polyamide, ceramic  
AL2O3, epoxy, fluorosilicone, glass, silicon).  
Low pressure port: To be used with non-corrosive,  
non-ionic working fluids such as clean dry air, dry  
gases and the like.  
SPECIFICATIONS  
ELECTRICAL CONNECTION  
Maximum ratings  
Supply voltage VS  
... 12 VDC  
Environmental  
+Vs  
Temperature ranges  
Operating  
4
-40 ... +85 °C (-40 ... +125 °C)7  
-40 ... +125 °C  
Storage3  
Humidity limits (non-condensing)  
...95 %RH8  
(100 % condensing or direct liquid media on high pressure port1)  
-Vout  
1
+Vout  
3
Vibration  
max. 10 g, 10...2000 Hz, random  
(EN 60068-2-64)  
Mechanical shock  
max. 50 g, 11 ms  
(EN 60068-2-27)  
Lead solder temperature  
max. 270 °C  
(JESD22-B106D)  
2
GND  
E / 11801 / B  
1/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PRESSURE SENSOR CHARACTERISTICS  
(VS=5.0 VDC, TA=25 °C, RH=50 %, pressure applied to high pressure port)  
Bar pressure ranges  
Full-scale span5  
Operating  
pressure  
0...100 mbar  
0...350 mbar  
0...1 bar  
Proof  
pressure4  
2 bar  
Part number  
Min.  
Typ.  
Max.  
HMUM100...  
HMUM350...  
HMUB001...  
HMUB2x5...  
HMUB005...  
HMUB010...  
30 mV  
40 mV  
60 mV  
60 mV  
60 mV  
60 mV  
30 mV  
60 mV  
60 mV  
60 mV  
60 mV  
120 mV  
160 mV  
140 mV  
140 mV  
140 mV  
140 mV  
70 mV  
2 bar  
5 bar  
100 mV  
100 mV  
100 mV  
100 mV  
100 mV  
50 mV  
0...2.5 bar  
0...5 bar  
10 bar  
14 bar  
14 bar  
4 bara  
4 bara  
8 bara  
14 bara  
0...10 bar  
0...1 bara  
0...2 bara  
0...4 bara  
0...8 bara  
HMUB001A...  
100 mV  
100 mV  
100 mV  
140 mV  
140 mV  
140 mV  
HMUB004A...  
HMUB008A...  
Psi pressure ranges  
Part number  
Full-scale span5  
Typ.  
Operating  
pressure  
0...1 psi  
Proof  
pressure4  
30 psi  
Min.  
Max.  
83 mV  
HMUM100...  
HMUM350...  
HMUB001...  
HMUB2x5...  
HMUB005...  
20 mV  
39 mV  
61 mV  
57 mV  
58 mV  
41 mV  
61 mV  
30 mV  
61 mV  
51 mV  
41 mV  
0...5 psi  
30 psi  
75 psi  
98 mV  
103 mV  
96 mV  
96 mV  
70 mV  
103 mV  
51 mV  
103 mV  
86 mV  
158 mV  
145 mV  
136 mV  
136 mV  
97 mV  
145 mV  
73 mV  
145 mV  
121 mV  
0...15 psi  
0...35 psi  
0...70 psi  
0...100 psi  
0...150 psi  
0...15 psia  
0...30 psia  
0...100 psia  
150 psi  
200 psi  
200 psi  
200 psi  
58 psia  
58 psia  
200 psia  
HMUB010...  
HMUB001A...  
HMUB008A...  
E / 11801 / B  
2/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PERFORMANCE CHARACTERISTICS2  
(VS=5.0 VDC, TA=25 °C, RH=50 %, pressure applied to high pressure port)  
Characteristics  
Min.  
-40  
Typ.  
0
Max.  
40  
Unit  
Zero pressure offset  
HMUM100...  
HMUB001A...  
all others  
-50  
0
50  
mV  
-30  
0
30  
Temperature effects  
(25...85 °C)  
Offset 1 psi devices  
100 mbar devices  
-0.44  
-0.30  
-0.20  
-0.15  
-0.60  
-0.30  
-0.20  
-0.10  
-0.10  
-0.23  
-0.23  
-0.21  
0.25  
0.24  
-0.22  
-0.15  
-0.07  
±0.03  
±0.16  
±0.08  
0
0
0
350 mbar/5 psi devices  
100 psi devices  
0
0.15  
0.60  
0.30  
0.20  
0.10  
0.10  
-0.18  
-0.17  
-0.17  
0.36  
0.31  
±0.90  
±0.35  
±0.40  
4.0  
1 bar/15 psi absolute devices  
2 bar/30 psi absolute devices  
4 bar absolute devices  
all other absolute devices  
all others  
%FSS/°C  
±0.04  
±0.02  
-0.21  
-0.19  
-0.19  
0.31  
0.26  
±0.50  
±0.15  
±0.10  
3.4  
Span 100 mbar/1 psi devices  
absolute devices  
all others  
Bridge impedance absolute devices  
%/°C  
%FSS  
k  
all others  
Non-linearity6  
100 mbar/1 psi devices  
absolute devices  
all others  
Bridge resistance  
absolute devices  
all others  
2.8  
2.8  
3.3  
3.8  
Specification notes:  
1. All wetted materials are selected to give a high level of media compatibility. Media compatibility refers to media inside the  
pressure port and lid. Improved media compatibility on high pressure port (backward side of sensor chip) since media has no  
contact to electronic components. Nevertheless tests with the media used in the specific application are recommended.  
2. Sensor is specified in air, changes in sensor behaviour based on physical effects caused by the specific media can occur.  
Weight of the media and wetting forces can influence the sensor characteristics.  
3. Storage temperature of the sensor without package.  
4. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters  
of the sensing element.  
5. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.  
6. Non-linearity refers to the Best Straight Line fit, measured for offset pressure, full scale pressure and 1/2 full scale pressure.  
7. Not for all pressure ranges. Please contact First Sensor if operating temperature range -40...+125 °C is required.  
8. Tested 1h, up to 85 °C.  
Sensors are electronic components and should be handled only in ESD save environments.  
E / 11801 / B  
3/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION  
HMU...DU1..., ...AX1... (SIL, axial no ports)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
first angle projection  
dimensions in mm  
High pressure  
E / 11801 / B  
4/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...DU7... (SIL, 2 ports axial opposite side, barbed)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
5/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...GX7..., ...AX7... (SIL, 1 port axial, barbed)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
6/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...GZ7..., ...AZ7... (DIP, 1 port axial, barbed)  
5
6
7
8
4
3
2
1
Pin Connection  
1
2
3
4
5
6
7
8
-Vout  
GND  
+Vout  
+Vs  
GND  
GND  
I / C*  
I / C*  
* Internal connection.  
Do not connect for  
any reason  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
7/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...DU6... (SIL, 2 ports axial opposite side, straight big)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
8/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...GX6..., ...AX6... (SIL, 1 port axial, straight big)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
9/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...GZ6..., ...AZ6... (DIP, 1 port axial, straight big)  
5
6
7
8
4
3
2
1
Pin Connection  
1
2
3
4
5
6
7
8
-Vout  
GND  
+Vout  
+Vs  
GND  
GND  
I / C*  
I / C*  
* Internal connection.  
Do not connect for  
any reason  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
10/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...DU5... (SIL, 2 ports axial opposite side, needle big)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
11/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...GX5..., ...AX5... (SIL, 1 port axial, needle big)  
Pin Connection  
1
2
3
4
-Vout  
GND  
+Vout  
+Vs  
High pressure port  
first angle projection  
dimensions in mm  
E / 11801 / B  
12/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)  
HMU...GZ5..., ...AZ5... (DIP, 1 port axial, needle big)  
5
6
7
8
4
3
2
1
Pin Connection  
1
2
3
4
5
6
7
8
-Vout  
GND  
+Vout  
+Vs  
GND  
GND  
I / C*  
I / C*  
* Internal connection.  
Do not connect for  
any reason  
High pressure port  
dimensions in mm  
E / 11801 / B  
13/14  
www.first-sensor.com  
www.sensortechnics.com  
HMU Series  
Basic pressure sensors  
NOMENCLATURE  
Differential and Gage devices  
Series  
HMU M100  
M350  
Pressure range  
Pressure mode / Housing  
Porting  
Grade  
Options  
100 mbar / 1 psi DU Differential, SIL, 2 ports axial  
1* no port  
P Prime  
opposite side  
350 mbar / 5 psi  
7
Barbed  
B001  
1 bar / 15 psi GX Gage, SIL,1 port, axial  
2.5 bar / 35 psi GZ Gage, DIP, 1 port axial  
5 bar / 70 psi  
(5) Needle big  
B2x5  
(6) Straight big  
* not available for Gage  
devices, use Differential  
devices instead  
B005  
B010 10 bar / 100 psi / 150 psi  
( ) available on request  
Please contact First Sensor  
Example: HMU B001  
GZ  
7
P
Absolute devices  
Series  
Pressure range  
Pressure mode / Housing  
Porting  
Grade  
Options  
HMU B001 1 bar / 2 bar / 15 psi / 30 psi AX Absolute, SIL, 1 port axial  
1
7
no port  
Barbed  
P Prime  
B004  
B008  
4 bar AZ Absolute, DIP, 1 port axial  
8 bar / 100 psi  
(5) Needle big  
(6) Straight big  
( ) available on request  
Please contact First Sensor  
Example: HMU B001  
AZ  
7
P
LABEL INFORMATION  
Digit  
1 2  
Series  
M U  
3
4
5
6
7
8
9 10 11 12 13 14  
Production code  
Pressure unit /  
Grade/  
voltage  
Pressure range  
pressure mode /  
calibration  
Housing  
Porting  
Char  
-
HMU 7 100 mbar / 1 psi U bar,  
U SIL,  
2 ports axial  
opposite side  
X SIL,  
1 port, axial  
1 no port  
7 Barbed  
- High, 5 V  
gage/differential,  
unidirectional  
J
A
B
C
350 mbar / 5 psi  
+ Prime, 5 V  
1 bar / 15 psi B bar,  
gage/differential,  
bidirectional  
5 bar / 70 psi A bara, absolute  
5 Needle big / High, 3 V  
6 Straight big # Prime, 3 V  
2.5 bar / 35 psi  
Z DIP,  
1 port axial  
M 10 bar / 150 psi /  
8 bara  
N
4 bara  
First Sensor reserves the right to make changes to any products herein.  
First Sensor does not assume any liability arising out of the application  
or use of any product or circuit described herein, neither does it convey  
any license under its patent rights nor the rights of others.  
E / 11801 / B  
14/14  
www.first-sensor.com  
www.sensortechnics.com  

相关型号:

HMUM100DU1P

Basic pressure sensors
SENSORTECHNIC

HMUM100DU5P

Basic pressure sensors
SENSORTECHNIC

HMUM100DU6P

Basic pressure sensors
SENSORTECHNIC

HMUM100DU7P

Basic pressure sensors
SENSORTECHNIC

HMUM100GX1P

Basic pressure sensors
SENSORTECHNIC

HMUM100GX5P

Basic pressure sensors
SENSORTECHNIC

HMUM100GX6P

Basic pressure sensors
SENSORTECHNIC

HMUM100GX7P

Basic pressure sensors
SENSORTECHNIC

HMUM100GZ1P

Basic pressure sensors
SENSORTECHNIC

HMUM100GZ5P

Basic pressure sensors
SENSORTECHNIC

HMUM100GZ6P

Basic pressure sensors
SENSORTECHNIC

HMUM100GZ7P

Basic pressure sensors
SENSORTECHNIC