CG45.6199.151 [SCHURTER]
Mains Power Connector, 6A, 250VAC, Male, Quick Connect Terminal, Socket;型号: | CG45.6199.151 |
厂家: | SCHURTER INC. |
描述: | Mains Power Connector, 6A, 250VAC, Male, Quick Connect Terminal, Socket 连接器 电源连接器 |
文件: | 总4页 (文件大小:285K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
POWER ENTRY MODULES
CG
Power entry modules
Types CG, CG-Bowdencable
– Panel mount: screw-on version, front-side
– 5 functions: appliance inlet, line switch or line switch for
Bowdencable actuation, fuseholder with interchangeable
fuse drawer for 5 x 20 or 6,3 x 32 mm fuses, with series-
parallel voltage selector, line filter
Fuse drawer
Standard or
Medical filter
Pushbutton for front panel
actuation
Voltage selector
insert
50
75
100
Bowden cable eliminates wiring
between pushbutton and power
entry module
Remote mechanical line switch
Characteristics
•
•
All single elements are allready partial wired
The “Extra-Safe” fuse drawers satisfy international standards for
medical equipment. The drawer can only be removed with the aid
of a tool
•
•
The fuseholder is accessible from the equipment front
Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
125/250 VAC; 50/60 Hz
a
Rated currents Type CG
Type CG-
1–10 A; @T 40 °C
a
1–6 A; @T 40 °C; SEV, VDE, Semko
a
Bowdencable 1–6 A / 250 VAC; @T 40 °C; UL, CSA
a
1–8 A / 125 VAC; @T 40 °C; UL, CSA
Leackage current, Standard
Medical
Test voltage (2 sec)
< 0,5 mA (250 V/60 Hz)
< 5 µA (250 V/60 Hz)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
Allowable ambient air
a
temperatures T
–25 °C to +85 °C
Climatic category
25/085/21 acc. to IEC/EN 60068-1
Degree of protection (front-side) IP40 acc. to IEC 60529
Protection class
suitable for equipment with prot. cl. I,
acc. to IEC 61140
Terminals
Panel thickness s
Materials: Housing
quick-connect 4,8 x 0,8 mm
max. 8 mm
Thermoplastic, black, UL94 V–0
120
www.schurter.com
POWER ENTRY MODULES
CG
Technical data
Appliance-inlet
acc. to. IEC/EN 60320-1/C14,
Protection class I, pin-temperature 70 °C
(cold condition)
Fuseholder
1- or 2-pole, shocksafe category PC2
acc. to IEC/EN 60127-6
for fuse-links 5 x 20 or 6,3 x 32 mm
Rated power acceptance at
5 x 20: 2,5 W (1-pole)/2 W (2-pole) per pole
6,3 x 32: 3,15 W (1-pole)/2,5 W (2-pole)
per pole
a
ambient air temp. T 23 °C
Admissible power acceptance
see derating curves. Take note of the
information on page 197
a
at higher T
Line switch
2-pole, non illuminated
(Rocker switch)
acc. to IEC/EN 61058-1
Line switch for Bowdencable
2-pole, non illuminated
Technical details see page 201
series-parallel, 4, 3 or 2 switch positions
or usable as a 2-pole change-over
switch.
Voltage selector
Line filter, standard and medical acc. to. IEC 60939, EN 133 200,
UL 1283, CSA C 22.2 no. 8
Technical details see page 202
Dimensions type CG
Mounting screw torque 0,5 Nm
Panel cut-out
Dimensions type CG Bowdencable
Panel cut-out see type CG
Details and description for Bowdencable see
page 59
R ꢀ 0,5
Panel cut-out for the actuating part B1
Mounting screw torque 0,5 Nm
121
www.schurter.com
POWER ENTRY MODULES
CG
Diagrams
Standard version
with fuseholder 1- or 2-pole
Medical version
with fuseholder 2-pole
Load
Line
Line
Load
x) Connections to be made by customer
Optional accessory cables (stranded conductor) for voltage selector
wiring see on page 63
Technical data of filter-components
Rated current
(A)
Filter-Type
Inductance
L1/L2 (mH)
Capacitance
CX (nF)
R
(MΩ)
CY (nF)
2 x 2,2
1
2
4
6
10
1
2
4
6
10
2 x 10
2 x 4
Standard
2 x 1,5
2 x 0,8
2 x 0,3
2 x 10
2 x 4
2 x 1,5
2 x 0,8
2 x 0,3
–
1
68
–
68
Medical
Derating curves for fuseholder
Fuses
1-pole
5 x 20 mm
2-pole
(per pole)
Fuses
1-pole
6,3 x 32 mm
2-pole
(per pole)
a
Ambient air temperature T °C
Attenuation loss
Standard version
Medical version
differential mode
common mode
4 A
4 A
1 A
1 A
2 A
6 A
2 A
6 A
122
www.schurter.com
POWER ENTRY MODULES
CG
Attenuation loss
Standard version
Medical version
differential mode
common mode
10 A
10 A
Order Numbers to type CG for socket
Fuse drawer and voltage selector insert must be ordered separately.
Order nos see pages 62, 63
Type
CG
Order no
Rated current Filter-Type
Line switch
Fuseholder
1-pole
CG16.5101.151
CG26.5101.151
CG36.5101.151
CG46.5101.151
CG66.5101.151
CG10.6101.151
CG20.6101.151
CG30.6101.151
CG40.6101.151
CG60.6101.151
CGG0.6101.151
CGA0.6101.151
CGC0.6101.151
CGE0.6101.151
CGL0.6101.151
1 A
2 A
Standard
4 A
2-pole
6 A
10 A
1 A
2 A
4 A
Standard
2-pole
2-pole
2-pole
2-pole
6 A
10 A
1 A
2 A
4 A
Medical
6 A
10 A
Order Numbers to type CG-Bowdencable: for socket
Fuse drawer, voltage selector insert and Bowdencable must be
ordered separately.
Order nos see page 63 (fuse drawer), 62 (voltage selector insert)
and 59 (Bowdencable)
Type
Order no
Rated current Filter-Type
Line switch
Fuseholder
for Bowdencable
2-pole
CG
CG15.6199.151
1 A
Standard
Standard
Medical
Bowden- CG25.6199.151
cable
2 A
4 A
6 A
1 A
2 A
4 A
6 A
1 A
2 A
4 A
6 A
1-pole
2-pole
2-pole
CG35.6199.151
CG45.6199.151
CG10.6199.151
CG20.6199.151
CG30.6199.151
CG40.6199.151
CGG0.6199.151
CGA0.6199.151
CGC0.6199.151
CGE0.6199.151
2-pole
2-pole
Accessories see page 171
123
www.schurter.com
相关型号:
CG451T200R4C
Reliable Screw Terminal Aluminum Electrolytic Capacitor 85 ⅹC, Screw Terminal Capacitors
CDE
CG451T200R4C0PL
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 200V, 50% +Tol, 10% -Tol, 450uF
CDE
©2020 ICPDF网 联系我们和版权申明