5145.A146F150C0.231 [SCHURTER]

Mains Power Connector, 2A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT;
5145.A146F150C0.231
型号: 5145.A146F150C0.231
厂家: SCHURTER INC.    SCHURTER INC.
描述:

Mains Power Connector, 2A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT

连接器 电源连接器
文件: 总6页 (文件大小:1334K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Power entry modules with line filter  
5ꢀ45  
www.schurter.com/pg06  
Inlet filter, front side mounting, circuit breaker TA45 2-pole  
Standard- or Medical-Filter  
Screw-On Version  
C14  
70° C  
Description  
Characteristics  
-ꢀPanelꢀMount:  
-ꢀAllꢀsingleꢀelementsꢀareꢀalreadyꢀwired  
ꢀ Unwiredꢀversionsꢀavailableꢀonꢀrequest  
-ꢀLineꢀswitchꢀnon-illuminatedꢀorꢀilluminated  
ꢀ Thermalꢀoverloadꢀprotection  
ꢀ Screw-onꢀfromꢀfrontꢀsideꢀ  
-ꢀ3ꢀFunctions:  
ꢀ ApplianceꢀInletꢀProtectionꢀclassꢀI,ꢀcircuitꢀbreakerꢀtypeꢀTA45ꢀ2-  
pole,ꢀLineꢀfilterꢀinꢀstandardꢀandꢀmedicalꢀversionꢀ  
-ꢀQuickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmmꢀ  
-ꢀAlternative:ꢀversionꢀwithoutꢀlineꢀfilterꢀꢀ6145ꢀꢀ  
-ꢀWeꢀrecommendꢀforꢀnewꢀapplicationsꢀtheꢀnewꢀtypeꢀꢀDF12ꢀꢀ  
ꢀ Optionalꢀwithꢀundervoltageꢀreleaseꢀorꢀremoteꢀtripꢀrelease  
-ꢀQualifiedꢀforꢀuseꢀinꢀequipmentꢀaccordingꢀIEC/ENꢀ60950  
Weblinks  
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀe-Store,ꢀSCHURTER-Stock-Check,ꢀ  
Distributor-Stock-Check  
Approvals  
-ꢀVDEꢀLicenseꢀNumber:ꢀ117118  
-ꢀULꢀLicenseꢀNumber:ꢀE72928  
Technical Data  
RatingsꢀIEC  
RatingsꢀUL/CSA  
LeakageꢀCurrent  
1ꢀ-ꢀ10Aꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250VAC;ꢀ50Hz  
1ꢀ-ꢀ15Aꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ125VAC;ꢀ60Hz  
standardꢀ<ꢀ0.5mAꢀ(250Vꢀ/ꢀ60Hz)ꢀ  
medicalꢀ<ꢀ5ꢀµAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)  
>ꢀ1.7kVDCꢀbetweenꢀL-Nꢀ  
>ꢀ2.7kVDCꢀbetweenꢀL/N-PEꢀ  
Testꢀvoltageꢀ(2sec)  
-10°Cꢀtoꢀ55°C  
10/055/21acc.ꢀto,ꢀIECꢀ60068-1  
fromꢀfrontꢀsideꢀIPꢀ40ꢀacc.ꢀtoꢀIECꢀ60529  
Suitableꢀforꢀappliancesꢀwithꢀprotectionꢀ  
classꢀIꢀacc.ꢀtoꢀIECꢀ61140  
Quickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmm  
Screw-on:ꢀmaxꢀ8mmꢀ  
Appliance-Inlet/-Outlet  
Circuitꢀbreaker  
C14ꢀacc.ꢀtoꢀIEC/ENꢀ60320-1,ꢀ  
ULꢀ498,ꢀCSAꢀC22.2ꢀno.ꢀ42ꢀ(forꢀcoldꢀ  
conditions)ꢀpin-temperatureꢀ70ꢀ°C,ꢀ10A,ꢀ  
ProtectionꢀclassꢀI  
Acc.ꢀIEC/ENꢀ60934,ꢀULꢀ1077,ꢀCSAꢀ  
22.2ꢀno.ꢀ235ꢀ  
2-poleꢀrockerꢀswitch,ꢀilluminatedꢀorꢀnon-  
illuminated.ꢀOptionalꢀwithꢀundervoltage-ꢀ  
orꢀremoteꢀtripꢀreleaseꢀ  
ShortꢀcircuitꢀcapacityꢀIcn:ꢀ  
atꢀInꢀ<ꢀ3A/240VACꢀ:ꢀ10ꢀxꢀInꢀ  
atꢀInꢀꢀ3A/240VACꢀ:ꢀ300A  
Rockerꢀswitchꢀ2-poleꢀnon-illuminatedꢀorꢀ  
illuminatedꢀacc.ꢀtoꢀIECꢀ61058-1ꢀ  
Technicalꢀdetails  
StandardꢀandꢀMedicalꢀVersion,ꢀIECꢀ  
60939,ꢀIECꢀ60601-1,ꢀULꢀ1283,ꢀULꢀ544,ꢀ  
ENꢀ133ꢀ200,ꢀCSAꢀC22.2ꢀno.ꢀ8ꢀ  
Technicalꢀdetails  
DielectricꢀStrength  
AllowableꢀOperationꢀTemp.  
ClimaticꢀCategory  
DegreeꢀofꢀProtection  
ProtectionꢀClass  
LineꢀSwitch  
LineꢀFilter  
Terminal  
PanelꢀThicknessꢀs  
Mountingꢀscrewꢀtorqueꢀmaxꢀ0.5Nm  
Thermoplastic,ꢀblack,ꢀULꢀ94V-0  
Material:ꢀHousing  
MTBF  
>ꢀ100'000hꢀacc.ꢀtoꢀMIL-HB-217ꢀF  
EMC products  
Power entry modules with line filter  
5ꢀ45  
www.schurter.com/pg06  
Dimensions  
Length  
ꢀ67.5ꢀmm  
Detail A  
2
0
+0.2  
29  
36  
1
43  
A
6.3x0.8mm  
0
-0.5  
R 3  
6.3x0.8mm  
50.7  
M3/ø 3.6  
13.5  
67.5*  
* --- Version TA45 with undervoltage release  
Technical Data of Filter-Components  
Rated Current  
[A]  
Filter-Type  
Inductances Capacitance Capacitance  
R [M]  
L [mH]  
CX [nF]  
CY [nF]  
1
2
Standard Version  
2 x 11  
2 x 4  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
2.2  
2.2  
2.2  
2.2  
2.2  
2.2  
2.2  
2.2  
-
-
-
Standard Version  
3
Standard Version  
2 x 2.5  
2 x 1.6  
2 x 0.7  
2 x 0.6  
2 x 0.4  
2 x 0.1  
2 x 11  
2 x 4  
-
4
Standard Version  
-
6
Standard Version  
-
8
Standard Version  
-
10  
15  
1
Standard Version  
-
Standard Version  
-
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
1
1
1
1
1
1
2
-
6
2 x 0.7  
2 x 0.6  
2 x 0.4  
2 x 0.1  
-
8
-
10  
15  
-
-
Diagrams  
Standard version  
Medical version  
1) Line  
2) Load  
1) Line  
2) Load  
EMC products  
Power entry modules with line filter  
5ꢀ45  
www.schurter.com/pg06  
-ꢀ-ꢀ-ꢀ-ꢀdifferentialꢀmodeꢀ_____ꢀcommonꢀmode  
Attenuation Loss  
Standardꢀversion  
1 A  
2 A  
3 A  
4 A  
6 A  
8 A  
10 A  
15A  
Medicalꢀꢀversionꢀ(M5)  
1 A  
2 A  
3 A  
4 A  
6 A  
8 A  
10 A  
15A  
EMC products  
Power entry modules with line filter  
5ꢀ45  
www.schurter.com/pg06  
EMC products  
4
Power entry modules with line filter  
5ꢀ45  
www.schurter.com/pg06  
20ꢀPcsꢀ  
Packaging unit  
Accessory  
Description  
Assorted Covers  
Rear Cover  
0859.0074  
Passende Dose  
Category / Description  
Appliance Outlet  
IEC appliance outlet F, screw-on mounting, front side, solder /quick connect terminal  
IEC appliance outlet F, screw-on mounting, front side, solder /quick connect terminal  
IEC appliance outlet F oder H, screw-on mounting, front side, solder/PCB/quick connect terminal  
IEC appliance outlet F oder H, screw-on mounting, front side, solder/quick connect terminal  
4787  
4788  
5091  
5092  
Connector  
IEC cord connector C15, rewirable, straight  
IEC cord connector C15A, rewirable, straight  
IEC cord connector C15A, rewirable, straight  
IEC cord connector C15A, rewirable, angled  
IEC cord connector C13, rewirable, angled  
IEC cord connector C13, rewirable, angled  
IEC cord connector C13, rewirable, straight  
IEC cord connector C13, rewirable, straight  
IEC cord connector C13, rewirable, straight  
IEC cord connector C13, rewirable, angled  
0101  
0102  
0102-G  
0112  
4012  
4013  
4020  
4021  
4022  
4300-06  
...  
Power Supply or Interconnection Cord  
Power Cord with IEC Appliance Connector C13, angled, 70°C  
Power Cord with IEC Appliance Connector C13, angled, 70°C  
Power Cord with IEC Appliance Connector C13, angled, 70°C  
Power Cord with IEC Appliance Connector C13, angled, 70°C  
Power Cord with IEC Appliance Connector C13, 70°C  
0311  
3011  
3012  
3013  
3020  
3027  
302U  
3030  
311L  
312L  
...  
Power Cord with IEC Appliance Connector C13, straight, 70°C  
Power Cord with IEC Appliance Connector C13, straight, 70°C  
Power Cord with IEC Appliance Connector C13, straight, 70°C  
Power Cord with IEC Appliance Connector C13, angled, 70°C  
Power Cord with IEC Appliance Connector C13, angled, 70°C  
EMC products  
5
Power entry modules with line filter  
5ꢀ45  
www.schurter.com/pg06  
Technical data (continued)  
Circuit breaker  
Tripping characteristics  
In < 3 A  
Tripping characteristics  
I
n * 3…) 15 A  
[ min ] [ sec ]  
10’000  
[ min ] [ sec ]  
10’000  
Type  
TA45  
< 3 A  
Type  
TA45  
Rated current  
I
n
Rated current  
I
3... 15 A  
n
60  
60  
1-pole protected  
1-pole protected  
2000  
30  
2’000  
30  
2-pole protected  
2-pole protected  
20  
20  
1000  
1’000  
Ambient temp.  
+23 °C  
+23 °C  
Ambient temp.  
10  
10  
500  
500  
5
5
200  
200  
100  
100  
1
1
50  
50  
20  
10  
5
20  
10  
5
2
1
2
1
0,5  
0,5  
0,3  
0,2  
0,3  
0,2  
0,1  
0,1  
1,05 1,32  
2
3
4
5
8
10  
1,05 1,32  
2
3
4
n
5
8
10  
Multiple of rated current  
[ x I  
]
Multiple of rated current  
[ x I  
]
n
1)  
Effect of ambient temperature  
* Temperature must be measured at the rear of the breaker next to  
the terminals after equipment operating temperature has been  
reached.  
The unit is calibrated for an ambient temperature of +23 °C. To  
determine the rated current for a lower or higher ambient tempera-  
ture, use a correction factor from the table below.  
1)  
Example  
* Ambient temperature [°C] Correction factor  
Rated current at +23 °C  
Ambient temperature  
Correction factor  
Chosen rated current at  
+ 40 °C ambient temperature  
6,0 A  
+40 °C  
1,08  
–10  
– 5  
0
0,89  
0,91  
0,92  
1,00  
1,03  
1,08  
1,16  
+23  
+30  
+40  
+55  
6 A x 1,08 = 6,5 A  
Order code (Order example)  
Wiring  
0 Without  
1 With  
Type of line filter  
1 Standard  
3 Medical  
Type  
Order code TA45  
(2-pole rocker-switch without  
accessories)  
5145.  
A
B T W F 1 5 0 C 0 . 0 0 1  
Rated current of line filter  
see table 1  
1
2
3
4
1 (A)  
2 (A)  
3 (A)  
4 (A)  
5
6
7
8
6 (A)  
8 (A)  
10 (A)  
15 (A)  
Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part  
number is, for example 5145.0031.001  
Theꢀspecifications,ꢀdescriptionsꢀandꢀillustrationsꢀindicatedꢀinꢀthisꢀdocumentꢀareꢀbasedꢀonꢀ  
EMC products  
currentꢀinformation.ꢀAllꢀcontentꢀisꢀsubjectꢀtoꢀmodificationsꢀandꢀamendments.  
6

相关型号:

5145.A146F150C0.311

Mains Power Connector, 3A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.330

Mains Power Connector, 3A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.331

Mains Power Connector, 3A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.410

Mains Power Connector, 4A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.411

Mains Power Connector, 4A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.431

Mains Power Connector, 4A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.510

Mains Power Connector, 6A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.530

Mains Power Connector, 6A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.610

Mains Power Connector, 8A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.611

Mains Power Connector, 8A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150C0.811

Mains Power Connector, 15A, 125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER

5145.A146F150U4.111

Mains Power Connector, 1A, 125/250VAC, Male, ROHS COMPLIANT
SCHURTER