4420.0414 [SCHURTER]

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic;
4420.0414
型号: 4420.0414
厂家: SCHURTER INC.    SCHURTER INC.
描述:

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic

文件: 总5页 (文件大小:397K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thermal-magnetic (TM and AS-line)  
AS168X Add-on modules  
https://www.schurter.com /PG20  
Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic  
Auxiliary contact  
Signal contact  
Relay trip module  
See below:  
Approvals and Compliances  
Description  
Applications  
- DIN-Rail Mounting  
- Auxiliary contact module  
- Industrial appliances  
References  
Last order possibility: 31.08.2018  
Last delivery date: 30.09.2018  
Each auxiliary contact module contains one contact, either normally  
open or normally closed  
- Signal contact module  
Signal contact modules are linked internally with the protected poles  
but not linked at the handles. Contacts are actuated by a fault condi-  
tion at the protected poles, not by manual operation of the CBE  
- Relay trip module  
Weblinks  
pdf datasheet, html-datasheet, General Product Information, Distributor-  
Stock-Check, Detailed request for product, Product News  
The relay trip module can be used for remote tripping of the adjacent  
poles by applying a voltage to the module's terminal  
Technical Data  
Ratings  
AC 277 V / 6 A (50/60 Hz)  
DC 125 V / 1 A  
Overload  
AC: min. 10trips  
@ 10 x Ir, p.f. = 0.3  
DC: min. 50trips  
@ 1.1 x Ir, L/R = 0.3 s  
-20°C to 60°C  
DC 50 V / 6 A  
IEC: Inc, PC1, AC 277 V: 1 kA  
Conditional short circuit ca-  
pacity  
Dielectric Strength  
Ambient temperature  
Vibration Resistance  
0.75 mm @ 10 - 60 Hz  
acc. to IEC 60068-2-6, test Fc  
10 G @ 60 - 500 Hz  
acc. to IEC 60068-2-6, test Fc  
30 G / 18ms  
acc. to IEC 60068-2-27, test Ea  
from front side IP 20 acc. to IEC 60529  
22 - 49g  
50Hz: > 2kV  
Impulse 1.2/50 μs  
> 5 MΩ  
mechanical: 50000switching cycles  
IEC 60947-5-1  
AC : 10 x Ir , p.f. = 0.3 :  
DC : 1 x Ir , L/R = 0.3 s :  
6050switching cycles  
Insulation Resistance  
Endurance typical  
Shock Resistance  
Degree of Protection  
Weight  
AC : 26 A / 2.6 A , p.f. = 0.35 :  
DC : 1.1 A / 1.1 A , L/R = 0.3 s :  
6000switching cycles  
Approvals and Compliances  
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about  
Approvals  
Approvals  
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.  
Approval Reference Type: AS168X  
Approval Logo  
Certificates  
Certification Body  
Description  
VDE Approvals  
VDE  
VDE Certificate Number: 40021845  
UL Approvals  
UL Approvals  
UL  
UL  
UL File Number: E216629 / E71572  
UL File Number: E216629 / E71572  
1
Circuit Breakers  
Thermal-magnetic (TM and AS-line)  
AS168X Add-on modules  
https://www.schurter.com /PG20  
Product standards  
Product standards that are referenced  
Organization  
Design  
Standard  
Description  
Designed according to  
IEC 60947-5-1  
Circuit-breakers for equipment (CBE)  
Designed according to  
Designed according to  
Designed according to  
UL 508  
Standard for Supplementary Protectors for Use in Electrical Equipment  
Standard for Industrial Control Equipment  
Supplementary Protectors  
UL 508  
CSA C22.2  
Application standards  
Application standards where the product can be used  
Organization  
Design  
Standard  
Description  
Designed for applications acc.  
IEC/UL 60950  
IEC 60950-1 includes the basic requirements for the safety of information  
technologyequipment.  
Compliances  
The product complies with following Guide Lines  
Identification  
Details  
Initiator  
Description  
CE declaration of conformity  
SCHURTER AG  
The CE marking declares that the product complies with the applicable  
requirements laid down in the harmonisation of Community legislation on  
its affixing in accordance with EU Regulation 765/2008.  
RoHS  
SCHURTER AG  
SCHURTER AG  
SCHURTER AG  
EU Directive RoHS 2011/65/EU  
China RoHS  
REACH  
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March  
2007. It is similar to the EU directive RoHS.  
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,  
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as  
"REACH") entered into force.  
Dimension [mm]  
AS168X-ACBH.  
AS168X-ACBA.  
AS168X-ACBS.  
17.5+-00..05  
17.5+-00..05  
17.5+-00..05  
2
Circuit Breakers  
Thermal-magnetic (TM and AS-line)  
AS168X Add-on modules  
https://www.schurter.com /PG20  
AS168X-Auxiliary contact  
45  
35.7  
90  
8.75+-00..05  
A)  
A) 35 mm DIN rail EN 50022  
60  
75.6  
Diagrams  
AS168X-CB1... / AS168X-ACBH1  
AS168X-CB1... / AS168X-ACBH2  
AS168X-CB1... / AS168X-ACBS1  
AS168X-CB1... / AS168X-ACBS2  
3
Circuit Breakers  
Thermal-magnetic (TM and AS-line)  
AS168X Add-on modules  
https://www.schurter.com /PG20  
Approvals Relay trip module  
Symbol  
Standard  
Rated voltage AC  
Rated voltage DC  
UL 508  
CSA C22.2 no. 14  
-
-
UL 1077  
up to 277 V  
up to 240 V  
CSA C22.2 no. 235  
EN 60934  
-
-
-
-
GB 17701  
-
-
Approvals Auxiliary contact  
Symbol  
Standard  
Rated current AC  
Rated voltage AC  
Rated current DC  
Rated voltage DC  
UL 508  
CSA C22.2 no. 14  
6 A  
277 V  
1 A  
6 A  
125 V  
50 V  
UL 1077  
6 A  
277 V  
1 A  
6 A  
125 V  
50 V  
CSA C22.2 no. 235  
EN 60934  
-
-
-
-
6 A (Ac-15)  
277 V  
1 A (DC-12)  
0.5 A (DC-13)  
6 A (DC-12)  
125 V  
125 V  
50 V  
GB 17701  
-
-
-
-
Approvals Signal contact  
Symbol  
Standard  
Rated current AC  
Rated voltage AC  
Rated current DC  
Rated voltage DC  
UL 508  
CSA C22.2 no. 14  
6 A  
277 V  
1 A  
6 A  
125 V  
50 V  
UL 1077  
6 A  
277 V  
1 A  
6 A  
125 V  
50 V  
CSA C22.2 no. 235  
EN 60934  
-
-
-
-
6 A (AC-15)  
277 V  
1 A (DC-12)  
0.5 A (DC-13)  
6 A (DC-12)  
125 V  
125 V  
50 V  
GB 17701  
-
-
-
-
Add-on modules  
Functional auxiliary contact  
Type H1 assumes the same contact  
position  
Type H2 assumes the opposite  
position  
Actuation of the contact is determined  
by the condition of the handle position  
of the adjacent poles.  
Functional signal contact  
Type S1 assumes the same contact  
position  
Type S2 assumes the opposite  
position  
The signal contact operates due to a  
thermal magnetic tripping and must  
be reset by hand.  
Function of relay trip module  
Type  
A1  
A2  
A3  
A4  
Voltage range AC/DC  
5 - 12 V  
10 - 24 V  
20 - 48 V  
40 - 110 V  
90 - 240 V  
Impedance at 50 Hz  
When voltage is applied across the  
terminals, remote tripping takes  
place by a self interrupting magnetic  
system.  
1.1  
4.7 Ω  
16 Ω  
63 Ω  
395 Ω  
Trip delay time 8 - 16 ms.  
A5  
Maximum Pole combination  
The maximum allowed number of poles/modules is 6, but in any combination, only 1 or 2 add-on modules are permitted  
1 or 2 add-on modules  
only 1 add-on module  
1 or 2 add-on modules  
+ 1 or 2 or 3 pole  
+ 4 pole  
+ 4 pole  
+ switched neutral  
+ switched neutral  
The time-current-curves are not relevant for the add-on modules.  
4
Circuit Breakers  
Thermal-magnetic (TM and AS-line)  
AS168X Add-on modules  
https://www.schurter.com /PG20  
Config. Code  
AS168X-ACB|H1|S2|A3|LOA|  
The characters are placeholders for the correspondingly keys of selections from the key tables.  
AS168X-ACB|H1|S2|A3|LOA|= Auxiliary contact  
Relay trip module  
Configuration  
key  
Auxiliary contact  
Configuration  
key  
Relay trip module AC/DC 5 -12 V  
Relay trip module AC/DC 10 -24 V  
Relay trip module AC/DC 20 - 48 V  
Relay trip module AC/DC 40 -110 V  
Relay trip module AC/DC 90 -240 V  
A1  
A2  
A3  
A4  
A5  
Auxiliary contact synchronized  
Auxiliary contact opposited  
H1  
H2  
AS168X-ACB|H1|S2|A3|LOA|= Signal contact  
Signal contact  
Configuration  
key  
AS168X-ACB|H1|S2|A3|LOA|= Relay trip module  
Signal contact synchronized  
Signal contact opposited  
S1  
S2  
Accessories  
Configuration  
key  
Lockout attachment  
LOA  
AS168X-ACB|H1|S2|A3|LOA|= Relay trip module  
Variants  
Auxiliary contact  
Signal contact  
Relay trip module  
Accessories  
Config. Code  
Order Number  
Auxiliary contact synchronized  
Auxiliary contact opposited  
AS168X-ACBH1  
AS168X-ACBH2  
AS168X-ACBA3  
AS168X-ACBA2  
AS168X-ACBS1  
AS168X-ACBS2  
AS168X-ACBLOA  
4420.0163  
4420.0176  
4420.0189  
4420.0340  
4420.0414  
4420.0415  
4420.0799  
Relay trip module AC/DC 20 - 48 V  
Relay trip module AC/DC 10 -24 V  
Signal contact synchronized  
Signal contact opposited  
Lockout attachment  
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER  
1 Pcs  
Packaging Unit  
The specifications, descriptions and illustrations indicated in this document are based on current  
information. All content is subject to modifications and amendments. Information furnished is believed  
to be accurate and reliable. However, users should independently evaluate the suitability and test each  
product selected for their own applications.  
5
Circuit Breakers  

相关型号:

4420.0416

Thermal Magnetic Circuit Breaker,
SCHURTER

4420.0459

Thermal Magnetic Circuit Breaker, ROHS COMPLIANT
SCHURTER

4420.0460

Circuit Breaker for Equipment thermal-magnetic, 1 pole
SCHURTER

4420.0512

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 1 pole
SCHURTER

4420.0519

Thermal Magnetic Circuit Breaker, ROHS COMPLIANT
SCHURTER

4420.0530

Circuit Breaker for Equipment thermal-magnetic, 1 pole
SCHURTER

4420.0542

Thermal Magnetic Circuit Breaker,
SCHURTER

4420.0560

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 2 poles
SCHURTER

4420.0569

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 3 poles
SCHURTER

4420.0572

Thermal Magnetic Circuit Breaker,
SCHURTER

4420.0595

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 1 pole
SCHURTER

4420.0596

Manual Motor Controller / Circuit Breaker for Equipment thermal-magnetic, 1 pole
SCHURTER