XUSL2E30H046NWC [SCHNEIDER]
XUSL type 2 IP69K Hand protection w/o Heating - Std range - Hp = 460mm, R=30mm;型号: | XUSL2E30H046NWC |
厂家: | SCHNEIDER ELECTRIC |
描述: | XUSL type 2 IP69K Hand protection w/o Heating - Std range - Hp = 460mm, R=30mm |
文件: | 总6页 (文件大小:180K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Product data sheet
Characteristics
XUSL2E30H076NWC
XUSL type 2 IP69K Hand protection w/o
Heating - Std range - Hp = 760mm, R=30mm
Main
Range of product
Preventa Safety detection
Safety light curtain type 2
Product or component
type
Device short name
Output type
XUSL2E
2 safety outputs OSSD solid-state PNP (arc
suppression)
Product specific
application
For hand protection
[R] Resolution
30 mm
[Sn] nominal sensing
distance
3…10 M by cabling
0…3 m by cabling
[Hp] Height protected
Number of beams
760 mm
38
Type of start / restart
Automatic
Manual
External Device
Selected by wiring
Monitoring (EDM)
Complementary
Detection system
Response time
Transmitter-receiver system
11 ms
Kit composition
Adjustable mounting bracket(s)
1 receiver(s)
1 transmitter(s)
1 user guide with certificate of conformity on CD-ROM
Silicone o-ring(s)
1 PVC cable(s)
[EAA] effective aperture angle
Emission
5 ° at 3 m
IR LED 950 nm
24 V DC +/- 20 %
[Us] rated supply voltage
Supply
Power supply conforming to IEC 61496-1
Power supply conforming to IEC 60204-1
[Ie] rated operational current
Current consumption
2 A
42 mA no-load transmitter
83 mA no-load receiver
42 mA transmitter
900 mA with maximum load receiver
Output current limits
Output voltage
0.4 A for safety outputs OSSD
24 V
DC
Output circuit type
Maximum voltage drop
Local signalling
<0.5 V
1 multi-colour LED transmitter
2 dual colour LEDs receiver
Electrical connection
1 male connector M12 5 pins transmitter
1 male connector M12 8 pins receiver
Type of cable
Unshielded cable AWG 22 10 m
55.31 mOhm
Ohmic cable resistance (per m)
Function available
Test
Muting through external safety module XPSLCMUT1160
LED display of operating modes and faults
Anti-condensation system
Marking
CE
Jan 19, 2021
1
Material
PMMA (polymethyl methacrylate): tube
Stainless steel AISI 316L: sealing plug
PVC (polyvinyl chloride): cable
Housing colour
Fixing mode
Red RAL 3000
By fixing brackets
5.05 kg
Net weight
Offer type
Standard distance
Without heating system
Provided equipment
Environment
Directives
98/37/EEC - machinery
2002/95/EC - RoHS directive
89/336/EEC - electromagnetic compatibility
89/655/EEC - work equipment
2002/96/EC - WEEE directive
Product certifications
CE
Ecolab
CULus
TÜV
Safety level (correctly wired)
Type 2 conforming to IEC 61496-1
Category 2 conforming to EN/ISO 13849-1
SIL 1 conforming to IEC 61508
SILCL 1 conforming to IEC 62061
PL = c conforming to EN/ISO 13849-1
Optical characteristic
Mission time
Resistance to light disturbance conforming to EN/IEC 61496-2
20 year(s)
Safety reliability data
PFHd = 4.57E-8 1/h conforming to IEC 61508
Ambient air temperature for operation
-10…55 °C
-30…55 °C
Ambient air temperature for storage
-30…70 °C
-25…70 °C
Relative humidity
0…95 % without condensation
IP degree of protection
Shock resistance
IP69K
10 gn for 16 ms conforming to IEC 61496-1
0.35 +/- 0.05 mm (f= 10…55 Hz) conforming to IEC 61496-1
Vibration resistance
Packing Units
Unit Type of Package 1
Number of Units in Package 1
Package 1 Weight
PCE
1
6.166 kg
13.5 cm
19.5 cm
85 cm
Package 1 Height
Package 1 width
Package 1 Length
Offer Sustainability
Sustainable offer status
REACh free of SVHC
EU RoHS Directive
Green Premium product
Yes
Pro-active compliance (Product out of EU RoHS legal scope)
Declaration
EU RoHS
Toxic heavy metal free
Mercury free
Yes
Yes
RoHS exemption information
Yes
Environmental Disclosure
Circularity Profile
Product Environmental Profile
End of Life Information
Contractual warranty
Warranty
18 months
2
Product data sheet
Dimensions Drawings
XUSL2E30H076NWC
Dimensions
3
Product data sheet
Mounting and Clearance
XUSL2E30H076NWC
Mounting and Clearance
4
Product data sheet
Connections and Schema
XUSL2E30H076NWC
Wiring Diagrams
Transmitter Pre-wired
Brown: +24 Vdc
White: Configuration_0
Blue: 0 Vdc
Green or Black: Configuration_1
Grey: Functional Earth
Pink: Not connected
Receiver pre-wired
White: Output signal switching device 1
Brown: +24 Vdc
Green: Output signal switching device 2
Yellow: Configuration_A
Grey: K1_K2 Feedback/Restart
Pink: Configuration_B
Blue: 0 Vdc
Yellow/Green (or Red): Functional Earth
For configuration_A and configuration_B,please refer to receiver configuration and operating modes
Receiver Configurations and Operating Modes
Automatic Start/Restart
Without External Device Monitoring (EDM) feedback loop
With External Device Monitoring (EDM) feedback loop
5
Manual Start/Restart
Without External Device Monitoring (EDM) feedback loop
(1) Restart
With External Device Monitoring (EDM) feedback loop
(1) Restart
Connecting to a Safety Interface
1 : Click on Download & Documents
2 : Click on Application solutions
To have all connection schematics concerning our safety module, select "download and document" and download the file "Safety light
curtains association with safety interfaces"
6
相关型号:
XUSL2E30H076NWC
XUSL type 2 IP69K Hand protection w/o Heating - Std range - Hp = 760mm, R=30mm
SCHNEIDER
XUSL2E30H091NWC
XUSL type 2 IP69K Hand protection w/o Heating - Std range - Hp = 910mm, R=30mm
SCHNEIDER
XUSL4E14F046NWH
XUSL type 4 Finger IP69K with Heating - Std Sensing Range - Hp = 460mm, R=14mm
SCHNEIDER
XUSL4E14F076NWC
XUSL type 4 Finger IP69K w/o Heating - Std Sensing Range - Hp = 760mm, R=14mm
SCHNEIDER
XUSL4E14F076NWH
XUSL type 4 Finger IP69K with Heating - Std Sensing Range - Hp = 760mm, R=14mm
SCHNEIDER
©2020 ICPDF网 联系我们和版权申明