Product data sheet
LC1D38B7
Characteristics
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V
38 A - 24 V AC 50/60 Hz coil
Product availability : Stock - Normally stocked in distribution facility
Price* : 193.00 USD
Main
Range
TeSys
Product name
TeSys D
Contactor
LC1D
Product or component type
Device short name
Contactor application
Resistive load
Motor control
Utilisation category
AC-3
AC-4
AC-1
Poles description
3P
Power pole contact composition
[Ue] rated operational voltage
3 NO
Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current
Motor power kW
50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
9 kW at 220...230 V AC 50/60 Hz (AC-3)
18.5 kW at 415...440 V AC 50/60 Hz (AC-3)
Motor power HP (UL / CSA)
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
5 hp at 240 V AC 50/60 Hz for 1 phase motors
20 hp at 480 V AC 50/60 Hz for 3 phases motors
25 hp at 600 V AC 50/60 Hz for 3 phases motors
Control circuit type
AC at 50/60 Hz
24 V AC 50/60 Hz
1 NO + 1 NC
[Uc] control circuit voltage
Auxiliary contact composition
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Jan 4, 2021
1
[Uimp] rated impulse withstand voltage
Overvoltage category
6 kV conforming to IEC 60947
III
[Ith] conventional free air thermal
current
10 A (at 60 °C) for signalling circuit
50 A 140 °F (60 °C) power circuit
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A 440 V power circuit IEC 60947
Rated breaking capacity
550 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
60 A 104 °F (40 °C) - 10 min power circuit
430 A 104 °F (40 °C) - 1 s power circuit
150 A 104 °F (40 °C) - 1 min power circuit
310 A 104 °F (40 °C) - 10 s power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG <= 690 V type 1 power circuit
63 A gG <= 690 V type 2 power circuit
Average impedance
2 mOhm - Ith 50 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit: 690 V conforming to IEC 60947-4-1
Electrical durability
1.4 Mcycles 50 A AC-1 at Ue <= 440 V
1.4 Mcycles 38 A AC-3 at Ue <= 440 V
Power dissipation per pole
5 W AC-1
3 W AC-3
Front cover
With
Mounting support
Rail
Plate
Standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications
CSA
LROS (Lloyds register of shipping)
BV
RINA
UL
GOST
DNV
CCC
GL
Connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end
Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²)flexible with cable end
Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable end
Tightening torque
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2
Operating time
4...19 ms opening
12...22 ms closing
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
2
Mechanical durability
15 Mcycles
Maximum operating rate
3600 cyc/h 60 °C
Complementary
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA
70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation
2…3 W at 50/60 Hz
Auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
Minimum switching current
Minimum switching voltage
Non-overlap time
25...400 Hz
5 mA for signalling circuit
17 V for signalling circuit
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Insulation resistance
Contact compatibility
Compatibility code
Motor power range
> 10 MOhm for signalling circuit
M2
LC1D
7…11 kW at 200…240 V 3 phases
15…25 kW at 380…440 V 3 phases
15…25 kW at 480…500 V 3 phases
15…25 kW at 525…690 V 3 phases
4…6 kW at 100…120 V 3 phases
Motor starter type
Direct on-line contactor
Environment
IP degree of protection
IP20 front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
3
Pollution degree
Ambient air temperature for operation
-40…60 °C
60…70 °C with derating
Ambient air temperature for storage
Operating altitude
-76…176 °F (-60…80 °C)
0...3000 m
Fire resistance
850 °C conforming to IEC 60695-2-1
V1 conforming to UL 94
Flame retardance
Mechanical robustness
Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open8 Gn for 11 ms
Height
3.35 in (85 mm)
1.77 in (45 mm)
3.62 in (92 mm)
0.84 lb(US) (0.38 kg)
Width
Depth
Net Weight
Ordering and shipping details
Category
22354 - CTR,TESYS D,OPEN,9-38A AC
Discount Schedule
GTIN
I12
00785901755470
1
Nbr. of units in pkg.
Package weight(Lbs)
0.92 lb(US) (0.42 kg)
3
Returnability
Yes
ID
Country of origin
Packing Units
Unit Type of Package 1
PCE
Package 1 Height
1.97 in (5 cm)
3.62 in (9.2 cm)
4.41 in (11.2 cm)
S02
Package 1 width
Package 1 Length
Unit Type of Package 2
Number of Units in Package 2
Package 2 Weight
Package 2 Height
20
19.19 lb(US) (8.705 kg)
5.91 in (15 cm)
11.81 in (30 cm)
15.75 in (40 cm)
P06
Package 2 width
Package 2 Length
Unit Type of Package 3
Number of Units in Package 3
Package 3 Weight
Package 3 Height
320
331.80 lb(US) (150.5 kg)
31.50 in (80 cm)
31.50 in (80 cm)
23.62 in (60 cm)
Package 3 width
Package 3 Length
Offer Sustainability
Sustainable offer status
California proposition 65
Green Premium product
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony
trioxide, which is known to the State of California to cause cancer. For more information go to
www.P65Warnings.ca.gov
REACh Regulation
REACh free of SVHC
EU RoHS Directive
REACh Declaration
Yes
Compliant
EU RoHS Declaration
Toxic heavy metal free
Mercury free
Yes
Yes
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
Product Environmental Profile
End of Life Information
The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins.
PVC free
Yes
Contractual warranty
Warranty
18 months
4
相关型号:
©2020 ICPDF网 联系我们和版权申明