VZ = 40 V (typ.)  
Automotive Alternator Diode  
SG-10LZ40 Series  
Data Sheet  
Description  
Package  
SZ-10  
The SG-10LZ40 series are the rectification diodes  
designed for alternator circuit of automotives, and have  
zener characteristics with high surge capability.  
The package is a soldering type, and has high heat  
release capability and high reliability for high  
temperature and humidity environment. In addition, the  
bridge circuit can be configured easily in small area by  
using suffix Stype and suffix Rtype of reverse  
polarity type.  
(1)  
Features  
(2)  
TJ = 160 °C Capability Suitable for High Reliability  
and Automotive Requirement  
High Surge Capability  
Bare Lead Frame: Pb-free (RoHS Compliant)  
(1)  
(2)  
(2)  
Suffix “S”  
Suffix “R”  
Applications  
(1)  
Alternator Circuit for the 24 V Battery Automotive  
Not to scale  
Suffix R”  
Pin No.  
(1)  
Suffix S”  
Cathode  
Anode  
Typical Application  
Anode  
(2)  
Cathode  
Voltage  
SG-10LZ40S  
Regulator  
Rotor  
Selection Guide  
VZ  
Battery  
TJ  
(Max.)  
Part Number  
IF(AV)  
Min.  
Max.  
44 V  
Stator  
SG-10LZ40S  
SG-10LZ40R  
30 A 160 °C 36 V  
SG-10LZ40R  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
1
© SANKEN ELECTRIC CO., LTD. 2017  
SG-10LZ40  
Absolute Maximum Ratings  
Unless otherwise specified, TA = 25 °C  
Parameter  
Symbol  
Conditions  
Rating  
32  
Unit  
V
Remarks  
Peak Reverse Voltage  
VRM  
TL ≤ 120 °C,  
see Figure 1.  
Half cycle sine-wave,  
positive side, 10ms,  
one shot.  
Average Forward Current  
Surge Forward Current  
IF(AV)  
30  
A
A
IFSM  
300  
One shot,  
See Figure 2.  
Surge Reverse Voltage  
Junction Temperature  
VRSM  
TJ  
50  
V
40 to 160  
°C  
TL  
0.8 Ω  
VRSM  
110 mF  
2 Ω  
Device  
Figure 1. Lead Temperature Measurement Conditions  
Figure 2. Surge Reverse Voltage Measurement Circuit  
(JASO A-1)  
Electrical Characteristics  
Unless otherwise specified, TA = 25 °C  
Parameter  
Symbol  
VF  
Conditions  
IF = 100 A  
Min. Typ. Max.  
Unit  
V
Remarks  
Forward Voltage Drop  
Reverse Leakage Current  
1.2  
50  
IR  
VR = VRM  
VR = VRM  
µA  
Reverse Leakage Current  
Under High Temperature  
,
HIR  
VZ  
36  
40  
35  
1.0  
2.5  
44  
mA  
V
TJ = 150 °C  
Breakdown Voltage  
IZ = 10 mA  
Breakdown Voltage  
Temperature Coefficient  
rZ  
IZ = 10 mA  
mV/°C  
°C/W  
(1)  
Thermal Resistance  
Rth(j-L)  
(1)  
R
th(j-L)  
is thermal resistance between junction and lead. Lead temperature is measured as shown in Figure 1.  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
2
© SANKEN ELECTRIC CO., LTD. 2017  
 
 
SG-10LZ40  
Rating and Characteristic Curves  
100  
1.E-03  
1.E-04  
1.E-05  
1.E-06  
1.E-07  
1.E-08  
1.E-09  
10  
TJ = 160 °C  
1
TJ = 160 °C  
TJ = 100 °C  
TJ = 60 °C  
TJ = 100 °C  
0.1  
0.01  
TJ = 60 °C  
TJ = 25 °C  
TJ = 25 °C  
0.001  
0.0  
0.2  
0.4  
Forward Voltage, VF (V)  
Figure 3. IF vs. VF Typical Characteristics  
100  
0.6  
0.8  
1.0  
1.2  
0
10  
20  
30  
40  
Reverse Voltage, VR (V)  
Figure 4. IR vs. VR Typical Characteristics  
10  
1
0.1  
0.01  
0.001  
t = 0.5 ms  
38 40 42 44 46 48 50 52 54  
Reverse Voltage, VZ (V)  
Figure 5. IZ vs. VZ Typical Characteristics  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
3
© SANKEN ELECTRIC CO., LTD. 2017  
SG-10LZ40  
10  
1
0.1  
0.01  
0.001  
Between Junction and Lead  
100 1000  
0.01  
0.1  
1
10  
Pulse Width (s)  
Figure 6. Typical Transient Thermal Resistance (2)  
(2) See Figure 1 for measurement conditions of lead temperature.  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
4
© SANKEN ELECTRIC CO., LTD. 2017  
SG-10LZ40  
Physical Dimensions  
SZ-10  
2-(R0.5)  
2-(8)  
10  
5
5
8.5  
10  
2
2-(R0.4)  
4.6  
)
2
4
(
See detail A  
2.5  
(
3
0
)
0.4  
1.0  
1.4  
3.0  
4.2  
5.0  
R1.2  
0.6  
4.4  
B
4-(R0.5)  
Copper area  
Copper area  
B-B' cross-section view  
B'  
2
-
2-(R0.5)  
(
8
)
7.2  
Detail A  
NOTES:  
- Dimensions in millimeters  
- Unless otherwise specified, tolerance is ±0.3 mm  
- Bare Lead Frame: Pb-free (RoHS Compliant)  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
5
© SANKEN ELECTRIC CO., LTD. 2017  
SG-10LZ40  
Marking Diagram  
(See Table 1)  
Specific Device Code  
Lot Number:  
YMDD  
Y is the last digit of the year of manufacture (0 to 9)  
M is the month of the year (1 to 9, O, N, or D)  
DD is the day of the month (01 to 31)  
Table 1. Specific Device Code  
Specific Device Code  
Part Number  
SG-10LZ40S  
SG-10LZ40R  
B44S  
B44R  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
6
© SANKEN ELECTRIC CO., LTD. 2017  
SG-10LZ40  
Important Notes  
All data, illustrations, graphs, tables and any other information included in this document (the Information) as to Sanken’s  
products listed herein (the “Sanken Products”) are current as of the date this document is issued. The Information is subject to any  
change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales  
representative that the contents set forth in this document reflect the latest revisions before use.  
The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its  
control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the  
Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products  
and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic  
signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss  
the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken  
Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any  
applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical  
equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class  
III or a higher class as defined by relevant laws of Japan (collectively, the “Specific Applications”). Sanken assumes no liability or  
responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from  
the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein.  
In the event of using the Sanken Products by either (i) combining other products or materials or both therewith or (ii) physically,  
chemically or otherwise processing or treating or both the same, you must duly consider all possible risks that may result from all  
such uses in advance and proceed therewith at your own responsibility.  
Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the  
occurrence of any failure or defect or both in semiconductor products at a certain rate. You must take, at your own responsibility,  
preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which  
the Sanken Products are used, upon due consideration of a failure occurrence rate and derating, etc., in order not to cause any  
human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products.  
Please refer to the relevant specification documents and Sankens official website in relation to derating.  
No anti-radioactive ray design has been adopted for the Sanken Products.  
The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all  
information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of  
use of the Sanken Products.  
Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third  
party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you,  
users or any third party, resulting from the Information.  
No information in this document can be transcribed or copied or both without Sanken’s prior written consent.  
Regarding the Information, no license, express, implied or otherwise, is granted hereby under any intellectual property rights and  
any other rights of Sanken.  
Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied,  
including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty  
of merchantability, and implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is  
delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course  
of dealing or usage of trade, and (iv) as to the Information (including its accuracy, usefulness, and reliability).  
In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and  
regulations that regulate the inclusion or use or both of any particular controlled substances, including, but not limited to, the EU  
RoHS Directive, so as to be in strict compliance with such applicable laws and regulations.  
You must not use the Sanken Products or the Information for the purpose of any military applications or use, including but not  
limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Information, or  
providing them for non-residents, you must comply with all applicable export control laws and regulations in each country  
including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and  
follow the procedures required by such applicable laws and regulations.  
Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including  
the falling thereof, out of Sanken’s distribution network.  
Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is  
error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting  
from any possible errors or omissions in connection with the Information.  
Please refer to our official website in relation to general instructions and directions for using the Sanken Products, and refer to the  
relevant specification documents in relation to particular precautions when using the Sanken Products.  
All rights and title in and to any specific trademark or tradename belong to Sanken and such original right holder(s).  
DSGN-AEZ-16003  
SG-10LZ40-DSE Rev.1.0  
Oct. 20, 2017  
SANKEN ELCTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
7
© SANKEN ELECTRIC CO., LTD. 2017  

相关型号:

SG-10LZ40R

Rectifier Diode,
SANKEN

SG-10LZ40S

VZ = 40 V (typ.) Automotive Alternator Diode
SANKEN

SG-112

Photointerrupters(Reflective)
KODENSHI

SG-113

Photointerrupters(Reflective)
KODENSHI

SG-12A03

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03C

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03CL

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03CV

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03CVL

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03L

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03V

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU

SG-12A03VL

SOLID STATE RELAY MAXIMUM LOAD CURRENT 3 A
FUJITSU