SA9103 / SA9603C APPLICATION NOTE  
sa m e s  
PM9103AP  
SINGLE PHASE POWER/ENERGY METERING MODULE  
SERIAL INTERFACE  
FEATURES  
n
n
n
Uses a shunt resistor for current  
sensing  
n
Performs both power and energy  
measurement  
Operates over a wide temperature  
range  
n
Meets the accuracy requirements for  
Class 1 AC Watt hour meters  
Serial interface having a RS232  
Protocol  
n
n
Protected against ESD  
Totalpowerconsumptionratingbelow  
500mW (excluding current sensing)  
DESCRIPTION  
The SAMES single phase power/energy metering module, the PM9103AP, provides  
energy data via a RS232 compatible serial interface.  
Energy consumption is determined by the power measurement being integrated over  
time.  
The method of calculation takes the power factor into account.  
The output of this innovative universal power/energy meter is ideally suited for energy  
calculations in applications using a µ-controller.  
The application utilises the SAMES SA9103CP, SA9103EP or SA9603CP power  
metering integrated circuits for power measurement.  
As a safety measure, this application shows the current sensor connected to the neutral  
line. In practice, the live line may be used for current sensing, provided that the supply  
connections (MAINS) are reversed on the module.  
1/10  
4309  
PDS038-SA9103-001  
REV.C  
11-08-98  
PM9103AP  
BLOCK DIAGRAM  
IN  
OUT  
NEUTRAL  
NEUTRAL  
OPTO  
COUPLER  
SHUNT  
SA9103  
SA9603  
NEUTRAL  
LIVE  
POWER  
SUPPLY  
POWER  
METER  
OPTO  
COUPLER  
VOLTAGE SENSE  
DR-01448  
ABSOLUTE MAXIMUM RATINGS*  
Parameter  
Symbol  
Min  
Max  
540  
+2.5  
+125  
Unit  
V
V
Supply Voltage (Note 1)  
Current Sense Input (Note 1)  
Storage Temperature  
VAC  
VIV  
TSTG  
TO  
-2.5  
-25  
-10  
°C  
Operating Temperature  
Max Current  
+70 (Note 2)  
800 (Note 3)  
2000 (Note 4)  
°C  
A
IMAX  
IMAX  
through Sensor  
A
Note 1: Voltages are specified with reference to Live.  
Note 2: The SA9103 and SA9603C integrated circuits are specified to operate over the  
temperature range -10°C to +70°C. The module functionality will however  
depend upon the external components used.  
Note 3: t = 500ms  
Note 4: t = 1ms  
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent  
damage to the device. This is a stress rating only. Functional operation of the device  
at these or any other conditions above those indicated in the operational sections of this  
specification, is not implied. Exposure to Absolute Maximum Ratings for extended  
periods may affect device reliability.  
2/10  
sa m e s  
PM9103AP  
ELECTRICAL CHARACTERISTICS  
(Over the temperature range -10°C to +70°C, unless otherwise specified. Power  
consumption figures are applicable to the PM9103APE only.)  
Parameter  
Symbol Min  
Typ Max  
Unit Condition  
Supply Voltage  
(Continuous)  
VAC  
180  
90  
230  
115  
265  
135  
V
V
PM9103APE  
PM9103APA  
Power Measurement  
range  
PRNG  
-18400  
18400  
W
Specified  
accuracy  
Power Consumption1  
800  
mW  
VAC = 230V  
Supply direct  
from mains  
Isolation Voltage2  
VIS  
2500  
V
Continuous  
Opto-coupler Output  
Current  
IO  
II  
10  
10  
mA  
mA  
VOL = 1V  
Opto-coupler Input  
Current  
Note 1: Power consumption specifications exclude power consumed by the current  
sensor.  
Note 2: Isolation voltage may be specified, depending on customer requirements.  
CONNECTION DESCRIPTION  
Designation  
Description  
Voltage supply connection to Neutral line  
Voltage supply connection to Live line  
Connection to positive side of current sensor  
MAINS  
NEUTRAL IN  
NEUTRAL OUT Connection to negative side of current sensor  
SK1  
D-sub connector  
Serial Input  
Serial Output  
9-Pin  
3/10  
sa m e s  
PM9103AP  
FUNCTIONAL DESCRIPTION  
1. Power Calculation  
In the Application Circuit (see Figure 2), the output current from the current sensor  
will be between 0 and 16µA (0 to 80A through a shunt resistor of 625µ). The current  
input stage of the module, saturates at input currents greater than 18µARMS. The  
mains voltage (Voltage + 15% - 20%) is used to supply the circuitry with power and  
to perform the power calculation, together with the current information from the  
current sensor (shunt resistor).  
The SA9103CP, SA9103EP and SA9603C integrated circuits may be adjusted to  
accommodate any voltage or current values. The method for calculating external  
component values is described in paragraph 6 (Circuit Description).  
SAMES offers two evaluation module options, namely 230V/80A and 115V/80A.  
The calculated power is integrated into a 22 bit integrator, which is accessable via  
a serial interface having a RS232 protocol. The power calculation takes the power  
factor into account.  
2. Electrostatic Discharge (ESD) Protection  
The device's inputs/outputs are protected against ESD according to the Mil-Std  
883C, method 3015. The modules resistance to transients will be dependant upon  
the protection components used.  
3. Power Consumption  
The overall power consumption rating for this power metering application (Figure 2),  
isunder500mW, excludingthecurrentsensor, whenthesupplyistakendirectly from  
the mains.  
4. Isolation  
The serial interface is isolated from the module which is at mains potential, via two  
opto-couplers. (In the event of the use of a current transformer for current sensing,  
the opto-couplers would not be required.)  
5. Serial Interface  
Reading and resetting of the on-chip integrators may be performed using a Personel  
Computer (PC). A standard serial cable should be used to connect SK1 to the PC.  
The computers port settings are as follows:  
19 200 Baud  
1 Start bit  
1 Stop bit  
No parity bits  
The Serial Interface allows for the following operations:  
Read Integrator: The device transmits the current integrator status to the controller,  
afterthecurrentmeasurementcyclehasbeencompleted(8mainsperiods maximum).  
4/10  
sa m e s  
PM9103AP  
Reset Integrator: The integrator is reset without transmitting the integrator  
status.  
Read/Reset Integrator: The device transmits the integrator status and resets the  
integrator after the current measurement cycle has been completed.  
In a typical application, the system controller monitors the status of the on-chip  
integrator using the "Read" command.  
If after a "Read" command, the integrator value is sufficiently high, a "Read/Reset"  
command from the controller causes the integrated circuit to complete the existing  
measurement cycle, transmit the 16 most significant bits of the 22 bit integrator  
via the Serial Output, to the controller and restart the integrator.  
The most significant bit of the 16 bits, indicates the direction of energy consumption  
measured (0 = Positive, 1 = Negative).  
Refer to the SA9103C, SA9103E or SA9603C datasheets for the serial interface  
command protocols.  
6. Circuit Description  
The Application Circuit (figure 2) shows the components required for the serial  
interface power metering module, using a shunt resistor for current sensing.  
In this application the device requires +2.5V, 0V, -2.5V DC supply.  
The most important external components are:  
C1 and C2 are the outer loop capacitors of the two integrated oversampling A/D  
converters. The value of these capacitors is 560pF. The actual values determine  
signal to noise and stability performance. The tolerance should be within ±10%.  
C3 and C4 are the inner loop capacitors of the A/D converters. The optimum value  
is 3.3nF. The actual values are uncritical. Values smaller than 0.5nF and larger  
than 5nF should be avoided.  
R2, R1 and RSH are the resistors defining the current level into the current sense  
input. Thevaluesshouldbeselectedforaninputcurrentof16µARMS intotheSA9103  
/ SA9603C at maximum line current.  
Values for RSH of less than 200µshould be avoided.  
R1 = R2 = IL/16µARMS * RSH/2.  
Where  
IL = Line current  
RSH = Shunt resistor/terminating resistor  
R3, R6 and R4 set the current for the voltage sense input. The values should be  
selected so that the input current into the voltage sense input (virtual ground) is set  
to 14µARMS  
.
R7 defines all on-chip bias and reference currents. With R7 = 24k, optimum  
conditions are set.  
5/10  
sa m e s  
PM9103AP  
XTAL is a colour burst TV crystal (f = 3.5795MHz) for the oscillator. The oscillator  
frequency is divided down to 1.7897MHz on-chip and supplies the A/D converters  
and the digital circuitry.  
7. Demonstration Software  
Software which runs under Windows 3.1 is provided with each evaluation module.  
See README.TXT on the diskette supplied for the installation instructions.  
Figure 1: Connection Diagram  
6/10  
sa m e s  
PM9103AP  
APPLICATION CIRCUIT  
Figure 2: Application using a Shunt Resistor for Current Sensing, having a PC  
(Personal Computer) Interface.  
Note: The Serial Interface having a RS232 protocol, has been designed to operate  
directly with a PC (Personal Computer).  
7/10  
sa m e s  
PM9103AP  
Parts List For Application Circuit: Figure 2  
Item  
1
2
3
4
5
6
7
8
Symbol  
IC-1  
IC-2  
IC-3  
D1  
D2  
D3  
ZD1  
ZD2  
XTAL  
R1  
Description  
SA9103CP/SA9103EP/SA9603C  
Opto Coupler 4N35  
Detail  
DIP-20  
DIP-6  
DIP-6  
Opto Coupler 4N35  
Diode, Silicon, 1N4148  
Diode, Silicon, 1N4148  
Diode, Silicon, 1N4148  
Diode, Zener, 2.4V, 200mW  
Diode, Zener, 2.4V, 200mW  
Crystal, 3.5795MHz  
Resistor, 1.6k, 1%, metal  
Resistor, 1.6k, 1%, metal  
Resistor, 1%, metal  
9
Colour burst TV  
Note 1  
Note 1  
Note 2  
Note 2  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
R2  
R3A  
R3B  
R4  
R5  
R6  
R7  
R8  
R9  
R10  
R12  
R13  
R14  
R15  
C1  
C2  
C3  
C4  
C9  
Resistor, 1%, metal  
Resistor, 1M, ¼W  
Resistor, 470, 2W, 5%, carbon  
Resistor, 24k, ¼W, metal  
Resistor, 24k, ¼W, metal  
Resistor, 680, ¼W, 5%  
Resistor, 680, ¼W, 5%  
Resistor, 680, ¼W, 5%  
Resistor, 120, ¼W, 5%  
Resistor, 120k, ¼W, 5%  
Resistor, 3.9k, ¼W, 5%  
Resistor, 120, ¼W, 5%  
Capacitor, 560pF  
Capacitor, 560pF  
Capacitor, 3.3nF  
Capacitor, 3.3nF  
Capacitor, 100nF  
Capacitor, 100nF  
Capacitor, polyester  
Capacitor, 100nF  
C10  
C11  
C12  
C13  
C14  
C15  
RSH  
Note 2  
Note 1  
Capacitor, 100µF, 16V  
Capacitor, 100µF, 16V  
Capacitor, 820nF, 16V  
Shunt Resistor, 80A, 50mV (625µ)  
Note 1: Resistor (R1 and R2) values are dependant upon the selected value of RSH. See  
paragraph 6 (Circuit Description) when selecting the value for RSH.  
Note 2: See the table below, detailing the component values for the selected voltage standard.  
8/10  
sa m e s  
PM9103AP  
Description  
Item  
Symbol  
Detail  
PM9103APA  
PM9103APE  
230V  
115V  
120kΩ  
82kΩ  
1µF  
12  
13  
31  
R3A  
R3B  
C11  
200kΩ  
180kΩ  
0.47µF  
ORDERING INFORMATION  
Part Number  
PM9103APA  
PM9103APE  
Description  
115V, 80A Module  
230V, 80A Module  
9/10  
sa m e s  
PM9103AP  
Disclaimer:  
TheinformationcontainedinthisdocumentisconfidentialandproprietarytoSouthAfricanMicro-  
Electronic Systems (Pty) Ltd ("SAMES") and may not be copied or disclosed to a third party, in whole or in part,  
without the express written consent of SAMES. The information contained herein is current as of the date of  
publication; however,deliveryofthisdocumentshallnotunderanycircumstancescreateanyimplicationthat the  
informationcontainedhereiniscorrectasofanytimesubsequenttosuchdate. SAMESdoesnotundertaketoinform  
anyrecipientofthisdocumentofanychangesintheinformationcontainedherein,andSAMESexpresslyreserves  
therighttomakechangesinsuchinformation,withoutnotification,evenifsuchchangeswouldrenderinformation  
containedhereininaccurateorincomplete. SAMESmakesnorepresentationorwarrantythatanycircuitdesigned  
byreferencetotheinformationcontainedherein, willfunctionwithouterrorsandasintendedbythedesigner.  
Any Sales or technical questions may be posted to our e-mail address below:  
energy@sames.co.za  
For the latest updates on datasheets, please visit out web site:  
http://www.sames.co.za  
South African Micro-Electronic Systems (Pty) Ltd  
P O Box 15888,  
Lynn East,  
0039  
33 Eland Street,  
Koedoespoort Industrial Area,  
Pretoria,  
Republic of South Africa,  
Republic of South Africa  
Tel:  
Fax:  
012 333-6021  
012 333-8071  
Tel:  
Fax:  
Int +27 12 333-6021  
Int +27 12 333-8071  
10/10  
sa m e s  

相关型号:

PM9103APA

SINGLE PHASE POWER/ENERGY METERING MODULE
SAMES

PM9103APE

SINGLE PHASE POWER/ENERGY METERING MODULE
SAMES

PM9105AFA

THREE PHASE POWER/ENERGY METERING MODULE PULSE OUTPUT
SAMES

PM9105AFE

THREE PHASE POWER/ENERGY METERING MODULE PULSE OUTPUT
SAMES

PM9105AP

THREE PHASE POWER/ENERGY METERING MODULE
SAMES

PM9106APA

SINGLE PHASE WATT MEASUREMENT MODULE WITH A 5 DIGIT LED DISPLAY
SAMES

PM9106APE

SINGLE PHASE WATT MEASUREMENT MODULE WITH A 5 DIGIT LED DISPLAY
SAMES

PM9109BFA

MONOCHIP SINGLE PHASE BIDIRECTIONAL KILOWATT HOUR METERING MODULE
SAMES

PM9109BFE

MONOCHIP SINGLE PHASE BIDIRECTIONAL KILOWATT HOUR METERING MODULE
SAMES

PM911

Single and dual output 5 to 6 Watt Nominal input DC/DC converters
ARTESYN

PM9110BFA

MONOCHIP THREE PHASE BIDIRECTIONAL KILOWATT HOUR METERING MODULE
SAMES

PM9110BFE

MONOCHIP THREE PHASE BIDIRECTIONAL KILOWATT HOUR METERING MODULE
SAMES