60K12L-000S3 [ROSENBERGER]
Calibration Kit;型号: | 60K12L-000S3 |
厂家: | Rosenberger Hochfrequenztechnik GmbH & Co. KG |
描述: | Calibration Kit |
文件: | 总3页 (文件大小:589K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical Data Sheet
Calibration Kit
7/16
60CK010-150
Industrial Version
Picture may differ from original product
Contents
Device
Open circuit plug
Part number
60S12L-000S3
60K12L-000S3
60S12S-000S3
60K12S-000S3
60S150-C10S3
60K150-C10S3
60S121-S20S3
60K121-K20S3
60W013-000
Quantity
Calibration Optiona
1
1
1
1
1
1
1
1
1
1
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
FC / AC
-
Open circuit jack
Short circuit plug
Short circuit jack
Calibration load plug
Calibration load jack
Calibration adaptor plug/plug
Calibration adaptor jack/jack
Combi wrench
Torque wrench
60W000-003
FC
a.
See “Declaration of calibration options” for explanation.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
1 / 3
Technical Data Sheet
Calibration Kit
7/16
60CK010-150
Industrial Version
Documentation
This kit is delivered with
•
USB-Stick
Standard Definitions as data files for Vector Network Anaylzer Families PNA (Keysight/Agilent) and ZVA
(Rohde&Schwarz). Calibration Certificate as PDF-file.
Standard Definitions Cards
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.
Kit Info Card
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.
Calibration Certificate
Details see “Declaration of calibration options”
•
•
•
•
Operating Manual
Electrical specifications
This specification covers electrical key values for the main calibration standards of the calibration kit.
Specific datasheets are available for each component among the part number.
Calibration standard
Frequency
Parameter
Specification
Opensb
(plug and jack)
DC
> 4 GHz to
to ≤ 4 GHz
Error from
Nominal Phase
≤ 1.0°
≤ 1.5°
≤ 8 GHz
Shortsb
(plug and jack)
DC
> 4 GHz to
to ≤ 4 GHz
≤ 8 GHz
Error from
Nominal Phase
≤ 1.0°
≤ 1.5°
DC
> 4 GHz to
to ≤ 4 GHz
≤ 8 GHz
≥ 40 dB
≥ 38 dB
Calibration loads
Return Loss
Return Loss
Return Loss
(plug and jack)
DC
> 4 GHz to
to ≤ 4 GHz
≤ 8 GHz
≥ 40 dB
≥ 36 dB
Calibration adaptors
(plug/plug)
DC
> 4 GHz to
to ≤ 4 GHz
≤ 8 GHz
≥ 38 dB
≥ 34 dB
Calibration adaptors
(jack/jack)
b.
The specifications for opens and shorts are given as allowed deviation from nominal model as defined in calibration certificate
included with your kit.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
2 / 3
Technical Data Sheet
Calibration Kit
7/16
60CK010-150
Industrial Version
Declaration of calibration options
Factory Calibration
Standard delivery for this kit includes a Factory Calibration. All devices marked with “FC” in the Content
table above are reported in a Calibration Certificate with their individual calibration results, traceable to
national / international standards. Model based definitions of the calibration standards are reported in
Agilent/Keysight, Rohde & Schwarz and Anritsu compatible VNA format.
Accredited Calibration
Optional this kit can be delivered with an Accredited Calibration (DAkkS) having the highest confidence in
the traceability. All devices marked with “AC” in the Content table above are reported in a DAkkS Calibration
Certificate with their individual calibration results in a complex format, traceable to national / international
standards. Model based definitions of the calibration standards are reported in Agilent/Keysight, Rohde &
Schwarz and Anritsu VNA format as well as in dense data sets needed for data based calibration kits. The
uncertainties are a little bit smaller than in a Factory Calibration.
All devices marked with “FC” only cannot be calibrated under accreditation. They are factory calibrated as
described above.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation
12 months
Recommended accessories
- Rosenberger Test Port Adaptor
- Rosenberger VNA Test cable kit and Microwave Cable Assemblies
- Rosenberger Gauge Kit 60GK0KS-010
For further, more detailed information please visit our homepage www.rosenberger.com.
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Rev.
b00
Engineering change number
16-1267
Name
Date
Martin Moder
12.10.15
H.Babinger
01.08.16
M. Knoll
01.08.16
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
3 / 3
相关型号:
60KQ20LB
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 20V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 3 PIN
NIEC
60KQ30B
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 30V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 3 PIN
NIEC
60KQ30E
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 30V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 1 PIN
NIEC
60KQ30LE
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 30V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 1 PIN
NIEC
60KQ40B
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 40V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 3 PIN
NIEC
60KQ40E
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 40V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 1 PIN
NIEC
60KQ50B
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 50V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 3 PIN
NIEC
60KQ60B
Rectifier Diode, Schottky, 1 Phase, 1 Element, 60A, 60V V(RRM), Silicon, SIMILAR TO TO-247AC (TO-3P), 3 PIN
NIEC
©2020 ICPDF网 联系我们和版权申明