02S101-K015 [ROSENBERGER]
Calibration Kit;型号: | 02S101-K015 |
厂家: | Rosenberger Hochfrequenztechnik GmbH & Co. KG |
描述: | Calibration Kit |
文件: | 总3页 (文件大小:1123K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical Data Sheet
Calibration Kit
RPC-2.92
02CK020-150
LRL Version
Contents
Device
Calibration
Optiona
Part number
Remarks
QTY
15 mm Air line plug/jack
18.3 mm Air line plug/jack
40 mm Air line plug/jack
Short circuit plug
02S101-K015
02S101-K018
02S101-K040
02S12S-001D3
02K12S-001D3
03W008-000
03W021-000
L1
1
1
1
1
1
1
1
FC
FC
FC
FC
FC
L2
L3
Reflect standard
Short circuit jack
Reflect standard
Combi wrench
-
-
Torque wrench
FC
a.
See “Declaration of calibration options” for explanation.
LRL calibrations without lowband loads are band limited. There are many different possibilities to calibrate
a VNA depending from the line length and the number of lines used during the calibration procedure. If
two lines are used the third line can be used as verification standard. The following graphs show two
possibilities using LRL with lowband loads. Without lowband loads the lower band cannot be calibrated.
Frequency Range (2 Bands)
Frequency Range (3 Bands)
Lowband loads
L1 and L2
Lowband loads
L1 and L2
L1 and L3
0
5
40
f in GHz
0
1
5
40
f in GHz
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
1 / 3
Technical Data Sheet
Calibration Kit
RPC-2.92
02CK020-150
LRL Version
Documentation
This kit is delivered with
•
USB-Stick
Standard Definitions as data files for Vector Network Anaylzer Families PNA (Keysight/Agilent) and ZVA
(Rohde&Schwarz). Calibration Certificate as PDF-file.
Standard Definitions Cards
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.
Kit Info Card
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.
Calibration Certificate
Details see “Declaration of calibration options”
•
•
•
•
Operating Manual
Electrical specifications
This specification covers electrical key values for the main items of the calibration kit. Specific datasheets
are available for each component among the part number.
Device
Frequency
Parameter
Specification
≤ 4 GHz
to
≤ 1.0°
≤ 2.0°
≤ 3.0°
DC
Shortsb
(plug and jack)
Error from
Nominal Phase
> 4 GHz to
> 18 GHz to
≤ 18 GHz
≤ 40 GHz
≤ 4 GHz
≤ 18 GHz
≤ 40 GHz
≥ 38 dB
≥ 35 dB
≥ 30 dB
0.3 GHz to
> 4 GHz to
> 18 GHz to
Precision air linesc
Return Loss
b.
c.
The specifications for the shorts are given as allowed deviation from nominal model as defined in calibration certificate included
with your kit.
Calculated value without warranty. The return loss specification includes the connector interfaces. The minimum frequency of
the air lines is based on calculations of the impedance change due to skin depth. Refer to the calibration certificate included with
your kit for the exact dimensions of your precision air lines.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
2 / 3
Technical Data Sheet
Calibration Kit
RPC-2.92
02CK020-150
LRL Version
Declaration of calibration options
Factory Calibration
Standard delivery for this kit includes a Factory Calibration. The Calibration Certificate issued reports
individual mechanical calibration results, traceable to national / international standards. Model based standard
definitions are reported in an Agilent, Rohde & Schwarz and Anritsu compatible VNA format.
Accredited Calibration
Not available.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation
12 months
Recommended accessories
- Rosenberger Test Port Adaptor
- Rosenberger Gauge Kit 03GK0KS-010
- Rosenberger VNA Test cable kit and Microwave Cable Assemblies
- Rosenberger Calibration Loads 02S150-C10S3 and 02K150-C10S3
For further, more detailed information please visit our homepage www.rosenberger.com.
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Rev.
b00
Engineering change number
16-0852
Name
Date
Martin Moder
08.12.14
Herbert Babinger
01.06.16
S. Andorfer
01.06.16
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Page
3 / 3
相关型号:
©2020 ICPDF网 联系我们和版权申明