TCTAL0J106M8R [ROHM]
Chip tantalum capacitors; 贴片钽电容型号: | TCTAL0J106M8R |
厂家: | ROHM |
描述: | Chip tantalum capacitors |
文件: | 总7页 (文件大小:134K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Chip tantalum capacitors
TCT Series AL Case
zFeatures (AL)
zDimensions (Unit : mm)
1) Vital for all hybrid integrated circuits
board application.
Anode mark
2) Wide capacitance range.
3) Screening by thermal shock.
(Unit : mm)
AL case
Dimensions
L
+
3.2 0.2
−
+
1.6 0.2
−
W
W
1
+
2
1.2 0.2
−
+
1.1 0.1
−
+
0.8 0.2
−
H
S
+
−
zPart No. Explanation
T C T A L 1 A 4 7 6 M 8 R
5
1
2
3
4
6
Nominal capacitance
1
2
4
Series name
TCT
Nominal capacitance in pF in 3 digits:
2 significant figures followed by the figure
representing the number of 0's.
Case style
AL
5
6
Capacitance tolerance
+
M : 20%
−
Rated voltage
3
2.5
4
6.3 10 16 20 25 35
Rated voltage (V)
CODE
Taping
0E 0G 0J 1A 1C 1D 1E 1V
Tape width
8 :
Positive electrode on the side opposite to sprocket hole
R :
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
1/6
TCT Series AL Case
Data Sheet
z Rated table
Rated voltage (V)
(µF)
2.5
0E
4
0G
6.3
0J
10
1A
16
1C
20
1D
25
1E
35
1V
∗
1.0 (105)
2.2 (225)
3.3 (335)
4.7 (475)
6.8 (685)
10 (106)
15 (156)
22 (226)
33 (336)
47 (476)
68 (686)
100 (107)
150 (157)
220 (227)
330 (337)
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
AL
∗
Remark) Case size codes (AL) in the above show products line-up.
Under development
∗
z Marking
The indications listed below should be given on the surface of a capacitor.
(1) Polarity : The polarity should be shown by bar. (on the anode side)
(2) Rated DC voltage : Due to the small size of AL case, a voltage code is used as shown below.
(3) Visual typical example (1) voltage code (2) capacitance code
Voltage
Code
Rated DC
Voltage (V)
Nominal
Capacitance (µF)
Capacitance
Code
e
g
j
2.5
4
A
J
1.0
2.2
3.3
4.7
6.8
10
6.3
10
16
20
25
35
N
S
W
a
e
j
A
C
D
E
V
15
22
n
s
33
47
w
a
e
j
68
100
150
220
330
n
A
s
[AL case]
note 1)
− −
(1) (2)
A s
manufacture code
note 2) voltage code and capacitance code are variable with parts number
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
2/6
TCT Series AL Case
Data Sheet
z Characteristics
Item
Performance
Test conditions (based on JIS C 5101−1 and JIS C 5101−3)
Voltage reduction when temperature exceeds +85°C
Operating Temperature
−55°C to +125°C
+85°C
Maximum operating
temperature with no voltage
derating
Rated voltage (VDC)
Category voltage (VDC)
Surge voltage (VDC)
DC Leakage current
2.5
4
6.3 10 16 20 25 35
at 85°C
at 125°C
at 85°C
1.6 2.5
3.2 5.0
4
8
6.3 10 13 16 22
13 20 26 32 44
Shall be satisfied the voltage on
" Standard list "
As per 4.9 JIS C 5101-1
As per 4.5.1 JIS C 5101-3
Voltage : Rated voltage for 5min
Capacitance tolerance
As per 4.7 JIS C 5101-1
As per 4.5.2 JIS C 5101-3
Shall be satisfied allowance range.
±
20%
Measuring frequency : 120
Measuring voltage : 0.5Vrms +1.5 to 2V.DC
Measuring circuit : DC Equivalent series circuit
±12Hz
Tangent of loss angle
(Df, tan δ)
Shall be satisfied the voltage on
" Standard list "
As per 4.8 JIS C 5101-1
As per 4.5.3 JIS C 5101-3
Measuring frequency : 120
±
12Hz
Measuring voltage : 0.5Vrms +1.5 to 2V.DC
Measuring circuit : DC Equivalent series circuit
As per 4.10 JIS C 5101-1
As per 4.5.4 JIS C 5101-3
Measuring frequency : 100
Impedance
Shall be satisfied the voltage on
" Standard list "
±
10kHz
Measuring voltage : 0.5Vrms or less
Measuring circuit
: DC Equivalent series circuit
Resistance to Appearance There should be no significant abnormality.
As per 4.14 JIS C 5101-1
As per 4.6 JIS C 5101-3
Dip in the solder bath
Soldering heat
The indications should be clear.
L.C.
Less than initial limit
Solder temp
Duration
: 260
: 5±
±5°C
0.5s
Within 20% of initial value
Less than 200% of initial limit
∆C / C
Repetition
: 1
Df (tan δ)
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Temperature
cycle
Appearance
There should be no significant abnormality.
The indications should be clear.
As per 4.16 JIS C 5101-1
As per 4.10 JIS C 5101-3
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
L.C.
Less than 200% of initial limit
Within 20% of initial value
Less than 200% of initial limit
∆C / C
Df (tan δ)
Temp.
Time
+
1
2
3
4
−55 3°C
30 3min.
−
Room temp. 3min. or less
+
125 2°C
30 3min.
−
Room temp. 3min. or less
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Moisture
resistance
Appearance There should be no significant abnormality.
The indications should be clear.
As per 4.22 JIS C 5101-1
As per 4.12 JIS C 5101-3
After leaving the sample under such atmospheric
condition that the temperature and humidity are
60 2°C and 90 to 95% RH, respectiveiy, for 500 12h
leave it at room
temperature for over 24h and then measure the
sample.
L.C.
Less than 200% of initial limit
Within 20% of initial value
∆C / C
Df (tan δ)
Less than 200% of initial limit
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
3/6
TCT Series AL Case
Data Sheet
Item
Performance
Test conditions (based on JIS C 5101−1 and JIS C 5101− 3)
As per 4.29 JIS C 5101-1
As per 4.13 JIS C 5101-3
Temperature
Stability
Temp.
∆C / C
Df (tan δ)
L.C.
−55°C
Within 0/−15% of initial value
Shall be satisfied the voltage on " Standard list "
−
Temp.
+85°C
∆C / C
Within +15/0% of initial value
Shall be satisfied the voltage on " Standard list "
5µA or 0.1CV whichever is greater
Df (tan δ)
L.C.
Temp.
∆C / C
Df (tan δ)
L.C.
+125°C
Within +20/0% of initial value
Shall be satisfied the voltage on " Standard list "
6.3µA or 0.125CV whichever is greater
There should be no significant abnormality.
As per 4.26JIS C 5101-1
Surge voltage Appearance
As per 4.14JIS C 5101-3
L.C.
Less than 200% of initial value
Within 20% of initial value
Less than 200% of initial limit
Apply the specified surge voltage every 5 0.5 min.
for 30 5 s. each time in the atmospheric condition of 85 2°C.
Repeat this procedure 1,000 times.
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
∆C / C
Df (tan δ)
Loading at
High temperature
Appearance
L.C.
There should be no significant abnormality.
Less than 200% of initial limit
As per 4.23 JIS C 5101-1
As per 4.15 JIS C 5101-3
After applying the rated voltage for 2000+72/0 h without
discontinuation via the serial resistance of 3Ω or less
at a temperature of 85 2°C, leave the sample at room
temperature / humidity for over 24h and measure the value.
Within 20% of initial value
∆C / C
Df (tan δ)
Capacitance
Appearance
Less than 200% of initial limit
Terminal
strength
The measured value should be stable.
There should be no significant abnormality.
As per 4.35 JIS C 5101-1
As per 4.9 JIS C 5101-3
A force is applied to the terminal until it bends to 1mm and
by a prescribed tool maintain the condition for 5s.
(See the figure below)
(Unit : mm)
20
50
F (Apply force)
R230
1
thickness=1.6mm
45
45
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
4/6
TCT Series AL Case
Data Sheet
Item
Performance
Test conditions (JIS C 5101−1 and JIS C 5101− 3)
As per 4.34 JIS C 5101-1
As per 4.8 JIS C 5101-3
Adhesiveness
The terminal should not come off.
Apply force of 5N in the two directions shown in the figure
below for 10 1s after mounting the terminal on a circuit board.
product
Apply force
a circuit board
Dimensions
Refer to "External dimensions"
Measure using a caliper of JIS B 7507 Class 2
or higher grade.
Resistance to solvents The indication should be clear
As per 4.32 JIS C 5101-1
As per 4.18 JIS C 5101-3
Dip in the isopropyl alcohol for 30 5s, at room
temperature.
Solderability
As per 4.15.2 JIS C 5101-1
3/4 or more surface area of the solder coated
As per 4.7 JIS C 5101-3
Dip speed=25 2.5mm / s
terminal dipped in the soldering bath should
be covered with the new solder.
Pre-treatment (accelerated aging): Leave
the sample on the boiling distilled water for 1 h.
Solder temp. : 245 5°C
Duration
Solder
Flux
: 3 0.5s
: M705
: Rosin 25% IPA 75%
As per 4.17 JIS C 5101-1
Frequency : 10 to 55 to 10Hz/min.
Amplitude : 1.5mm
Measure value should not fluctuate during the
measurement.
Vibration
Capacitance
Time : 2h each in X and Y directions
Mounting : The terminal is soldered on a print circuit board.
Appearance There should be no significant abnormality.
z Standard products list, TCT series
Df
120Hz
(%)
Impedance
100kHz
Leakage
current
25°C
1WV.5min
(µA)
Rated
voltage
85°C
Category
voltage
125°C
Surge
voltage
85°C
Cap.
120Hz
Tolerance
(%)
Part No.
25°C
85°C
(µF)
−55°C
125°C
(Ω)
(V)
(V)
(V)
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
+
−
TCT AL 0E 227
∗TCT AL 0E 337
TCT AL 0G 107
TCT AL 0G 157
TCT AL 0G 227
TCT AL 0J 686
TCT AL 0J 107
TCT AL 1A 336
TCT AL 1A 476
TCT AL 1C 156
TCT AL 1C 226
TCT AL 1D 106
TCT AL 1E 475
TCT AL 1E 685
TCT AL 1V 225
TCT AL 1V 335
2.5
2.5
4
1.6
1.6
2.5
2.5
2.5
4
3.3
3.3
5.2
5.2
5.2
8.0
8.0
13
220
330
100
150
220
68
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
5.5
16.5
4.0
6.0
20
35
80
35
35
35
35
34
30
35
30
35
30
30
30
30
30
20
30
20
20
20
20
18
15
20
15
20
15
15
15
15
15
25
40
25
25
25
25
24
20
25
20
25
20
20
20
20
20
2.5
2.5
3.0
2.7
2.5
4.0
3.0
4.0
4.0
4.0
4.0
8.0
8.0
8.0
8.0
8.0
4
4
6.3
6.3
10
10
16
16
20
25
25
35
35
4.3
6.3
3.3
4.7
2.4
3.6
2.0
1.2
1.7
0.8
1.2
4
100
33
6.3
6.3
10
10
13
16
16
22
22
13
47
20
15
20
22
26
10
32
4.7
6.8
2.2
3.3
32
45
45
=Tolerance (M : ±20%)
∗ : Under development
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
5/6
TCT Series AL Case
Data Sheet
z Packaging specifications
Case code
A
0.1
B
0.1
t
1
±
0.05
t2 0.1
±
±
±
1.9
3.5
0.25
1.3
AL
Taping [AL case]
+0.1
−0
t1
φ1.5
A
B
Chip
4.0±
0.1
4.0
±0.05
±0.1
t
2
2.0
Feeding direction
z Packaging style
Case code
AL case
Packaging
Taping
Packaging style
Symbol Basic ordering units
plastic taping φ180mm Reel
R
3,000pcs
Reel [AL case]
+
11.4 1.0
−
Pull direction
Label sticking position
EIAJ ET−7200B
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
6/6
Appendix
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM
CO.,LTD.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you
wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM
upon request.
Examples of application circuits, circuit constants and any other information contained herein illustrate the
standard usage and operations of the Products. The peripheral conditions must be taken into account
when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document. However, should
you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no re-
sponsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and examples
of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to
use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no re-
sponsibility whatsoever for any dispute arising from the use of such technical information.
The Products specified in this document are intended to be used with general-use electronic equipment
or devices (such as audio visual equipment, office-automation equipment, communication devices, elec-
tronic appliances and amusement devices).
The Products are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or
malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard against the
possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as
derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your
use of any Product outside of the prescribed scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or system
which requires an extremely high level of reliability the failure or malfunction of which may result in a direct
threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment,
aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear
no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intend-
ed to be used for any such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may be controlled under
the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact your nearest sales office.
THE AMERICAS / EUROPE / ASIA / JAPAN
ROHM Customer Support System
Contact us : webmaster@ rohm.co.jp
www.rohm.com
TEL : +81-75-311-2121
FAX : +81-75-315-0172
Copyright © 2009 ROHM Co.,Ltd.
21 Saiin Mizosaki-cho, Ukyo-ku, Kyoto 615-8585, Japan
Appendix-Rev4.0
相关型号:
©2020 ICPDF网 联系我们和版权申明