SIMCARD [RFSOLUTIONS]

LOW COST GSM MODEM; 低成本GSM MODEM
SIMCARD
型号: SIMCARD
厂家: RFSOLUTIONS.LTD    RFSOLUTIONS.LTD
描述:

LOW COST GSM MODEM
低成本GSM MODEM

GSM
文件: 总10页 (文件大小:898K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LOW COST GSM MODEM  
Dual Band 900 / 1800 MHz  
Fax, SMS and Data  
Integral SIM Card holder  
Siemens TC-35i GSM Engine  
Rugged Extruded Aluminium  
Enclosure  
Compact Form Factor  
86 x 54 x 25mm  
RS232 Interface with  
Auto baud rate detection  
SMA Antenna Connection  
LED Indication of Operation  
Description  
The low cost TMAS GSM Modem is ideal for a wide range of applications. The modem can be used to make  
circuit switched data calls, making the unit suitable for remote dial-up systems where a fixed phone line is not  
available. The SMS functionality enables the sending and receipt of text messages. A common use for this  
functionality is an SMS server for the automated sending and receipt of bulk text messages.  
The modem implements the highly reliable Siemens TC35i GSM Engine. This ensures high quality and reliable  
operation along with compatibility with all standard GSM networks. The modem provides support for the  
Siemens TC35i AT command list, also available for download from the RF Solutions website.  
The TMAS modem is supplied in a rugged extruded aluminium enclosure making it suitable for use in a wide  
range of industrial and demanding environments. The unit connects directly to a PC or terminal device via the  
DB-9 RS232 Cable interface. The integral SIM card holder accepts standard SIM cards of all network operators.  
The only other connections required are to 6-40Vdc power supply and Antenna (supplied separately).  
Part Numbering  
Part Number  
Description  
GSM-T35I  
Dual Band GSM Modem  
GSM20-ANT  
CABLE-RS232  
SIMCARD  
Antenna with 2.5 Metre Coax, SMA connector  
RS232 Cable 9 Way D-Type Male to Female  
Vodafone Pay as you talk SIM Card, £1.00 Credit, 10p/Text  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 1  
LOW COST GSM MODEM  
Table of Contents  
1
2
Key Features ..................................................................................................................................................3  
Interface description.......................................................................................................................................4  
2.1 Power Supply..................................................................................................................................4  
2.2 RS232 Interface..............................................................................................................................4  
2.3 SIM Interface ..................................................................................................................................5  
2.4 Radio Interface ...............................................................................................................................5  
Operating Modes............................................................................................................................................6  
3.1 Status LED......................................................................................................................................6  
Basic Setup Information .................................................................................................................................7  
4.1 Modem functionality Test................................................................................................................7  
4.2 Basic AT Command List.................................................................................................................9  
Mechanical Characteristics ..........................................................................................................................10  
3
4
5
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 2  
LOW COST GSM MODEM  
1 Key Features  
Features  
Implementation  
Transmission  
Data, SMS, Fax  
Single supply voltage  
Min: 6Vdc  
Max: 40Vdc  
Power supply  
GSM class  
Small MS  
Dual Band E-GSM 900 and GSM 1800  
Compliant to GSM Phase 2/2+  
Frequency bands  
Class 4 (2W) for EGSM900  
Class 1 (1W) for GSM1800  
Transmit power  
SIM card reader  
External antenna  
SMS  
Internal  
Connected via antenna SMA connector  
MT, MO, CB, Text and PDU mode  
CSD transmission rates: 2.4, 4.8, 9.6, 14.4  
kbps, nontransparent,V.110  
CSD DATA  
FAX  
Unstructured Supplementary Services Data  
(USSD) support  
Group 3: Class 1, Class 2  
RS-232 interface, bi-directional bus for AT  
commands and data  
Multiplex ability according to GSM 07.10  
Multiplexer protocol  
Serial interface  
Baud rates from 300bps to 115,200bps  
Autobauding supports: 1,200, 2,400, 4,800,  
9,600, 19,200, 38,400, 57,600 and 115,200bps  
Supported SIM card  
3V  
Phonebook management  
Supported phonebook types: FD, LD, MC, RC, ON, ME  
Reset via AT command  
Reset of Terminal TMAS GSM  
Real time clock  
Implemented (clock frequency 32.768kHz)  
Normal operation: -20°C to +55°C  
Humidity: max. 80% relative humidity  
Environmental Temperature:  
Size  
86mmx54mmx25mm (Casing Dimension)  
82g (Approx.)  
Weight  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 3  
LOW  
COST GSM MODEM  
2 Interface description  
The TMAS GSM Terminal provides the following connectors for power supply, interfacing and antenna:  
2.1mm DC power connector (centre/inner pin is positive)  
9-pin (female) D-SUB plug for RS-232 serial interface  
SMA connector for antenna (radio interface)  
SIM card holder  
2.1 Power Supply  
The power supply of the TMAS GSM Terminal has to be a single voltage source of Vin=6V providing a peak  
current of up to 500mA during transmission.  
The terminal can be turned on by just plug in a 6VDC power supply. The terminal power supply circuit  
automatically generates a low pulse signal not less than 100ms in order to wake up the Siemens TC35i GSM  
engine.  
In order for the terminal to shut down properly, wait for 10s after sending AT^SMSO before switching off the  
power supply. This time is needed for the module to be safely logged off from the network and finish saving  
data to the internal memory.  
Each time the terminal is shut down, data will be written from the volatile memory to flash memory. The  
guaranteed maximum number of write cycles is limited to 100,000.  
2.2 RS232 Interface  
Via RS-232 interface, the host controller controls the TMAS GSM/GPRS Terminal and transports data. The  
table below shows the pin assignment of RS-232 (D-SUB 9-pin female).  
Pin no.  
Signal name  
/DCD  
/RXD  
/TXD  
I/O  
Function  
1
2
3
4
5
6
7
8
9
O
Data Carrier Detected  
Receive Data  
O
I
Transmit Data  
Data Terminal Ready  
Ground  
/DTR  
I
GND  
-
/DSR  
/RTS  
O
I
Data Set Ready  
Request To Send  
Clear To Send  
Ring Indication  
/CTS  
O
O
/RI  
TMAS GSM/GPRS Terminal is designed for use as DCE. Based on the conventions for DCE-DTE connection,  
it communicates with the user application (DTE) using the following signals:  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 4  
LOW COST GSM MODEM  
Pin TxD @ application sends data to TxD of TMAS GSM/GPRS Terminal  
Pin RxD @ application receives data from RxD of TMAS GSM/GPRS Terminal  
The RS-232 interface is implemented as a serial asynchronous transmitter and receiver conforming to ITU-T  
V.24 Interchange Circuits DCE. It is configured for 8 data bits, no parity and 1 stop bit, and can be operated at  
bit rates from 300bps to 115Kbps. Autobauding supports bit rates from 4.8Kbps to 115Kbps. Hardware  
handshake using the /RTS and /CTS signals and XON/XOFF software flow control are supported.  
In addition, the modem control signals /DTR, /DSR, /DCD and /RING are available. The modem control signal  
RING (Ring Indication) can be used to indicate to the cellular device application, that a call or Unsolicited Result  
Code (URC) is received. There are different modes of operation, which can be set with AT commands.  
2.3 SIM Interface  
The SIM interface is intended for 3V SIM cards in accordance with GSM 11.12 Phase 2. The card holder is a 5  
wire interface according to GSM 11.11. A sixth pin has been added to detect whether or not a SIM card is  
inserted.  
Removing and inserting the SIM card during operation requires the software to be reinitialized. Therefore, after  
reinserting the SIM card it is necessary to restart the terminal.  
Note:  
No guarantee can be given, nor nay liability accepted, if loss of data is encountered after removing the  
SIM card during operation.  
No guarantee can be given for properly initializing any SIM card that the user inserts after having  
removed a SIM card during operation. In this case, the application must restart the terminal.  
2.4 Radio Interface  
An internal RF cable is connected from the antenna reference point (antenna connector type GSC from Murata)  
to the SMA (female) connector. To attach the antenna to the TMAS GSM/GPRS Terminal, turn smoothly and  
slowly to the SMA (male) connector of antenna at clockwise direction.  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 5  
LOW COST GSM MODEM  
Both single band and dual band antenna can be used for TMAS GSM/GPRS Terminal as long as it comes with  
the SMA (male) connector.  
3 Operating Modes  
The table below briefly summarizes the various operating modes of the TMAS GSM terminal  
Mode  
Function  
SLEEP  
Various power saving modes set by AT+CFUN command.  
Software is active to minimum extent. If the Terminal was registered to the GSM  
network in IDLE mode, it remains, in SLEEP mode, registered and pageable from  
the BTS.  
Power saving can be chosen at different levels. The NON-CYCLIC SLEEP mode  
(AT+CFUN=0) disables the AT interface. The CYCLIC SLEEP mode AT+CFUN=5,  
6, 7 and 8 alternatively activate and deactivate the AT interface to allow permanent  
access to all AT commands.  
GSM IDLE  
GSM TALK  
Software is active. Once registered to the GSM network, paging with BTS  
Is carried out. The Terminal is ready to send and receive.  
Connection between two subscribers is in progress. Power consumption depends  
on network coverage individual settings, such as DTX off/on, FR/EFR/HR, hopping  
sequences, antenna.  
3.1 Status LED  
A red LED displays the operating status of the terminal.  
The table below summarizes the coding of the red LED status  
Operating status  
LED  
Power Down  
Off  
Not registered to the net (missing SIM, PIN, net)  
Standby (registered to the net)  
Sleep mode (Power save mode, registered to the net)  
Talk mode, GPRS data  
Fast Blinking  
Slow Flash (75ms On / 3s Off)  
Off  
On  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 6  
LOW COST GSM MODEM  
4 Basic Setup Information  
4.1 Modem functionality Test  
On the first time power-up you can use terminal communications program to communicate with the modem  
through the RS-232 serial port. Following example is using the HyperTerminal in Windows XP.  
4.1.1 Select Hyperterminal from the Start Menu  
4.1.2 Start the HyperTerminal program and assign any name for a new session.  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 7  
LOW COST GSM MODEM  
4.1.3 Choose the Com port connected to the modem. The unit features auto bauding so any baud rate from  
1.2 to 115.2 Kbps can be used, 8bits, no parity bit, 1 stop bit)  
4.1.4 On the terminal screen, type “AT” to check the “OK” response from the modem  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 8  
LOW COST GSM MODEM  
4.2 Basic AT Command List  
The commands in the table below can be used for basic control of the GSM modem.  
Description  
Network Registration AT+CREG?  
Checking  
AT commands  
Modem response  
CREG=<mode>,1  
Comments  
Modem registered to the network  
CREG=<mode>,2  
CREG=<mode>,0  
Registration lost, re-registration  
attempt  
Modem not registration on the  
network, no registration attempt  
Receiving signal  
strength  
Receiving an  
incoming call  
AT+CSQ  
+CSQ: 20,0  
RING  
The first parameter has to be at  
least 15 for normal communication  
An incoming call is waiting  
ATA  
Answer the call  
OK  
Make a call  
ATD1234567;  
Don’t forget the « ; » at the end for  
« voice » call  
OK  
Communication established  
CME ERROR : 11  
PIN code not entered (with + CMEE  
= 1 mode)  
CME ERROR : 3  
CME ERROR : 10  
AOC credit exceeded or a  
communication is already  
established  
Cannot read the SIM card  
Don’t forget the « ; » at the end for  
« voice » call  
Make an emergency ATD 112;  
call  
OK  
NO CARRIER  
Communication loss  
Hang up  
ATH  
OK  
Enter PIN code  
AT+CPIN=1234  
OK  
PIN Code accepted  
+CME ERROR : 16  
Incorrect PIN Code (with +CMEE =  
1 mode)  
+CME ERROR : 3  
PIN already entered (with +CMEE =  
1 mode)  
Saves parameters in AT&W  
non-volatile memory  
OK  
The configuration settings are  
stored  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 9  
LOW  
C
OST GSM MODEM  
5 Mechanical Characteristics  
Weight  
82g  
Dimension  
86mmx54mmx25mm  
-20°C to +55°C  
Temperature range  
Air humidity  
Casing material  
Maximum 80% relative humidity  
Aluminium alloy  
For more information or general enquiries contact:  
R F Solutions Ltd.  
Unit 21, Cliffe Industrial Estate,  
South Street, Lewes, BN8 6JL, England.  
Email: sales@rfsolutions.co.uk  
Tel: +44 (0)1273 898 000  
Web: http://www.rfsolutions.co.uk  
Fax: +44 (0)1273 480 661  
DS-GSMT35I-2 Oct ’07  
www.rfsolutions.co.uk  
2007 REG No 277 4001, ENGLAND.  
Page 10  

相关型号:

SIME3023SNC

Rack and Panel Connector, 30 Contact(s), Female, Crimp Terminal, Socket
AMPHENOL

SIMID

Size 0603 (EIA) and/or 1608 (IEC) Rated inductance 1 nH to 220 nH Rated current 110 mA to 1800 mA
EPCOS

SIMID-0603-C

Size 0603 (EIA) and/or 1608 (IEC) Rated inductance 1 nH to 220 nH Rated current 110 mA to 1800 mA
EPCOS

SIMM0108PCC

Rack and Panel Connector, 1 Contact(s), Male, Crimp Terminal
AMPHENOL

SIMM0108SBC

Rack and Panel Connector, 1 Contact(s), Female, Crimp Terminal, Socket
AMPHENOL

SIMM0118PBC

Rack and Panel Connector, 1 Contact(s), Male, Crimp Terminal
AMPHENOL

SIMM0118SBC

Rack and Panel Connector, 1 Contact(s), Female, Crimp Terminal, Socket
AMPHENOL

SIMM0118SCC

Rack and Panel Connector, 1 Contact(s), Female, Crimp Terminal, Socket
AMPHENOL

SIMM0118SDC

Rack and Panel Connector, 1 Contact(s), Female, Crimp Terminal, Socket
AMPHENOL

SIMM0128PBC

Rack and Panel Connector, 1 Contact(s), Male, Crimp Terminal,
AMPHENOL

SIMM0128PCC

Rack and Panel Connector, 1 Contact(s), Male, Crimp Terminal
AMPHENOL

SIMM0128SAC

Rack and Panel Connector, 1 Contact(s), Female, Crimp Terminal, Socket
AMPHENOL