230 [RFSOLUTIONS]
Modular Radio Telemetry System; 模块化的无线电遥测系统![230](http://pdffile.icpdf.com/pdf1/p00152/img/icpdf/230_843857_icpdf.jpg)
型号: | 230 |
厂家: | ![]() |
描述: | Modular Radio Telemetry System |
文件: | 总11页 (文件大小:392K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Modular Radio Telemetry System
200 Series
• Simple to Use Remote Control
• Range:
ꢀUpto 200 metres at 433MHz
• 8 Channels per Transmitter
• 16 Channels per Receiver
• Upto 48 Transmitters per system
• Auto Transmit Mode
• Secure RF Protocol
• Automatic ‘Watchdog’ Transmission
ꢀUpto 1,000 metres at 433MHz Narrow Band.
ꢀUpto 6,000 metres at 458MHz
• Requires no radio license
• Relay Outputs upto 30A @ 230Vac
• All Modules supplied with Antenna
Remote Telemetry Systems are well suited to industrial switching applications where telemetry signals need to
be sent remotely from one location to another.
This system allows multiple transmitters to a single receiver or a single transmitter to multiple receivers.
Each Transmitter module accepts upto 8 pairs of ‘Volt Free’ contacts as inputs via screw terminals. Each
Receiver has 16 outputs arranged as 4 x 4 easy plug in connectors to interface to any combination of output
modules.
Any of the output modules connect directly to the receiver (cable supplied) to provide transistor switching or relay
outputs.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 1
Modular Radio Telemetry System
200 Series
Transmitters
• 8 Input Channels
• Volt Free contact Inputs via Screw Terminals
• 12 / 24Vdc Supply
• Low Power Battery Version
200 Transmitter:
Standard transmitter
201 Transmitter:
Low Power Transmitter . (Designed for battery powered applications)
Range**
(Metres)
Freq
(MHz)
Compatible
Decoders
Part Number
Description
200-433FR
200-525NR
200-458FR
201-525NR
201-458FR
FM Transmitter
200
433.92
434.525
458.850
434.525
458.850
210-433F
210-525N
210-458F
210- 525N
210-458F
FM Narrow Band Transmitter
FM High Power Transmitter
FM Narrow Band Transmitter
FM High Power Transmitter
1,000
6,000
1,000
6,000
Receivers
• 16 Output Channels
• Volt Free contact Inputs via Screw Terminals
• 12 / 24Vdc Supply
• Low Power Battery Version
Range**
(Metres)
Freq
(MHz)
Compatible
Transmitter
Part Number
Description
210-433FR
210-525NR
210-458FR
FM Receiver
200
433.92
434.525
458.850
200/201-433F
200/201-525N
200/201-458F
FM Narrow Band Receiver
FM High Power REceiver
1,000
6,000
Output Modules
• Connect Directly to 210 Rx
(Cable Supplied)
• no power connections required
No of
Outputs
Max Switching
(per output)
Part Number
Description
211
215
216
230
Darlington Driver Outputs
Relay Module
16
8
0.5A @ 50V (Overall total 1A)
5A @230Vac
5A @230Vac
30A @230Vac
Relay Module
4
Relays Module
4
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 2
Modular Radio Telemetry System
200 Series
Enclosure / Power Supply
• IP56 Insulation Class 2
• DIN Rails mounted on Steel Plate
• 12Vdc 1A PSU incorporated accepts 110-240Vac (5A Fused)
Dimensions
External
315 x 235 x 130mm
300 x 220 x 120mm
285mm
Internal
DIN Rail length 1
DIN Rail length 2
180mm
Part No
Description
DIN Rail Enclosure Assembly, Two Mounting Rails, 12Vdc PSU Fitted
ENC-DA3
PSU12V1AIN-IP Power Supply 110-240Vac input, 12Vdc 1A Output
Custom systems
We regularly supply pre-wired / bespoke systems, please contact our sales dept for further
assistance
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate, South Street, Lewes,
E Sussex, BN8 6JL. England
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
Email sales@rfsolutions.co.uk
http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions products as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 3
Modular Radio Telemetry System
200 Series
1 Configuring a Remote Telemetry System
(200Tx/201Tx -> 210Rx)
There are three Steps:
1. Pre-Configure the 200 or 201 series transmitter
2. Pre- Configure the 210Rx to operate with a 200 or 201 series transmitter
3. Marry a 200/201Tx to a 210Rx
1.1
Pre-Configure a 200/201 Transmitter Encoder
1. Mapping the 200/201 Transmitter Inputs to the 210 Receiver Outputs
The Remote telemetry system automatically maps the 8 transmitter input channels to 8 receiver output
channels. The ‘8/15’ option link on the transmitter allows selection of channels 1-8 or 9-15 on the receiver.
200/201 Tx Option Link
Open
210 Rx output Channels
1 – 8
Connected
9 – 15
2. Enable Option Links (ENABLE 1-8)
The 200 and 201 Transmitters have eight ‘Enable’ Option links which must be fitted in order for the
corresponding input to be valid (otherwise the 210Tx will ignore it). This enables applications where many
transmitters are used with a single 210Rx (many to one relationship)
3. Auto Transmit with Watchdog Mode ‘Auto Tx’
When the ‘Auto Tx’ link is made, the 200/201 Tx automatically transmits its data once within every 5
second period, in addition, channel 16 is allocated as a ‘system watchdog‘. As long as the 210Rx
continues to receive this signal then output ‘16’ is held ON. If for any reason (fault or RF interference) the
signal is not received for approx 20secs then output ‘16’ will drop out.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 4
Modular Radio Telemetry System
200 Series
1.2
Pre-Configure a 210Rx to operate with a 200/201 Tx series transmitter
1. Ensure option link J8 is open.
2. Apply power to the 210Rx, All output LEDS flash alternately. This is factory reset default state.
3. Apply power to any 200 or 201 Tx and briefly operate any input by shorting any of the input terminals on
the transmitter (ensure Enable link is fitted!), to force a transmit.
4. The 210Rx. LED2 flashes 5 times to indicate that the 210Rx is now configured for use with 200 / 201Tx.
5. Each time power is applied the 210Rx, LED2 flashes 5 times to show it is configured to operate with
200Tx transmitters.
6. Configuration is now complete and 200/201 transmitter unit(s) can be learned to the 210Rx receiver.
Note: Option links LK 1-16 have no affect on the operation of the remote telemetry system.
1.3
Marry a 200/201 Tx to a 210Rx
1. On the 200/201 Tx, remove the Link header ‘OPT1‘ (auto Tx). (prevents automatic transmission during
the learn process).
2. On the 210Rx Ensure option link J8 is open.
3. Apply power to the 210Rx, note that LED2 flashes 5 times to show it is configured for use with 200Tx
transmitters.
4. Briefly press the 210Rx Learn Switch: Note that the 210Rx Learn LED (LED 17) will flash.
5. Wait until the 210Rx Learn LED has stopped flashing but is still illuminated.
6. Apply power to any 200/201 Tx and briefly operate any input by shorting any of the input terminals on the
Transmitter (ensure Enable link is fitted!), to force a transmit.
7. Note that the 210Rx learn LED will turn off.
8. The learn cycle is now complete and the transmitter/encoder will operate the systems.
1.4
Erasing the 210Rx Receiver Outputs (Return to Factory Default State)
1. To completely erase the 210Rx decoder’s memory, press and hold the 210Rx learn switch.
2. The learn LED will illuminate
3. Hold the learn switch until the learn LED extinguishes (approx 10 seconds).
4. Release the learn button and all the output LED’s will now flash alternately to indicate that all encoder data
has been erased and the 210Rx has returned to factory default state.
Note: It is not possible erase individual transmitters.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 5
Modular Radio Telemetry System
200 Series
1.5
Connecting output Modules to the 210 Receiver
A range of ‘200’ series output modules are available which can be plugged into the 210 Receiver via the four
IDC header boxes on the receiver. The selection of output module will be dependant on the application. Please
see DS200S-1 for a summary the available modules.
1.6
Connecting an Antenna
The 210Rx has a 200mm flying lead cable (50ohm) with a panel mount BNC socket provided to mount on an
enclosure. This cable may be extended however please note that typically there is a 50% range reduction
with every 3metres of coax cable used!
For increasing range performance a +3dB gain antenna is available. This is supplied with wall mounting
bracket and 2metres of coax cable, it plugs in directly to the 210Rx BNC connector.
1.7
Range
The antenna choice and position directly controls the system range. Keep it clear of other metal in the system.
The best position by far, is protruding from the top of the product. This is often not desirable for practical or
ergonomic reasons and thus a compromise may be needed. If an internal antenna must be used then try to
keep it away from other metal items, and in particular large ones like transformers, batteries and PCB tracks
and earth planes.
Note that the space around the antenna is as important as the antenna itself. All radio systems are dependant
on a radio signal being received through airspace.
The range quoted is the optimal in direct line of sight without obstacles and in good atmospheric conditions.
Range is affected by many things, for example local environmental conditions, atmospheric conditions,
interference from other radio transmitters. For evaluating the local environment please see our RF Meter
(DS006)
In very worse case applications the range quoted may be reduced to 30% of the optimal range stated.
1.8
Signal integrity
In systems where many encoders are in close proximity there may be occasions when, due to signal overlay
between encoders, it is difficult or impossible to guarantee system integrity. In such circumstances it is the
responsibility of the installer to ensure that the system performance is adequate for the purposes of the
installation.
1.9
Information availability
All products are supplied with their relevant datasheets. These are also available for download from the website
or on request from RF Solutions Ltd.
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate, South Street, Lewes,
E. Sussex, BN8 6JL, England
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
Email sales@rfsolutions.co.uk
http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
All Trademarks acknowledged and remain the property of the respected owners
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 6
Modular Radio Telemetry System
200 Series
Module Technical Specifications
Transmitters
• 8 Input Channels
• Volt Free contact Inputs via Screw Terminals
• 12 / 24Vdc Supply
• Range;
ꢀ
ꢀ
ꢀ
433MHz
up to
200 Metres
1,000 Metres
6,000 Metres
433MHz NB up to
458MHz up to
• High Security RF Protocol
• Low Power Battery Version
• Auto Transmit Mode
• Automatic ‘Watchdog’ Transmission
• Antenna Supplied
BNC Socket
This is a simple to use radio transmitter module which can
accept 8 pairs of ‘Volt free’ contacts inputs.
I/P 3
I/P 1
I/P 2
I/P 4
RF Tx
Auto Tx
8 / 15
When an input occurs the transmitter will transmit a data packet
over the RF link to an associated receiver. (That has been
learnt into the transmitter). The transmitter continually monitors
the status of its ‘inputs’. It transmits a signal on any input
change and also can be set to transmit automatically every 15
seconds .
200/201
Transmitter
Enable 1-8
12 / 24Vdc
Supply
I/P 5
I/P 6
I/P 7
I/P 8
Full configuration instructions are given further in this
document.
8 x Zero Volt Inputs
200 Transmitter:
201 Transmitter:
Standard transmitter
Low Power Transmitter . (Designed for battery powered applications)
Part Numbering
Range**
(Metres)
Freq
(MHz)
Compatible
Decoders
Part Number
Description
200-433FR
200-525NR
200-458FR
201-525NR
201-458FR
FM Transmitter
200
433.92
434.525
458.850
434.525
458.850
210-433F
210-525N
210-458F
210- 525N
210-458F
FM Narrow Band Transmitter
FM High Power Transmitter
FM Narrow Band Transmitter
FM High Power Transmitter
1,000
6,000
1,000
6,000
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by upto 50%
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 7
Modular Radio Telemetry System
200 Series
Technical Specifications
Dimensions: Within DIN Rail: 200Tx : 112 x 82 mm (PCB: 109 x 72mm)
201Tx 160 x 82 mm (PCB: 145 x 72mm)
Storage Temperature; -10 to +155o C
Operating Temperature; -0 to +55o Celsius.
Electrical Characteristics
Supply Voltage: 12V Supply
Supply Voltage: 24V Supply
Antenna Output Lead Impedance
Minimum input activation time to trigger transmission
433MHz / 433NBMHz Version
Supply Current: Quiescent
Supply Current: Transmitting Data
458MHZ Version
Min
10
21
Typical
Max
16
30
Units
V
V
Ohms
ms
12
24
50
5
10
170
mA
mA
150
240
Min
150
200
270
Max
200
Supply Current: Quiescent
Supply Current: Transmitting Data
10
250
mA
mA
200 Transmitter Current Consumption
433MHz / 433NBMHz Version
Supply Current: Quiescent
Supply Current: Transmitting Data
458MHZ Version
Typical
Units
10
170
mA
mA
Supply Current: Quiescent
Supply Current: Transmitting Data
10
250
mA
mA
240
270
201 Transmitter Current Consumption
Supply Current: Quiescent
Min
Typical
60
Max
Units
nA
Supply Current: Transmitting - 433MHz NB module
Supply Current: Transmitting - 458MHz module
50
180
mA
mA
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate, South Street, Lewes,
E. Sussex, BN8 6JL, England
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
http://www.rfsolutions.co.uk
Email sales@rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 8
Modular Radio Telemetry System
200 Series
Receivers
This DIN rail module performs the radio reception and
decoding for the 200 series modules. It has four output
connectors each with four digital outputs and displays the
output status on LED’s 1-16. Any of the DIN Rail output
modules lug into these connectors marked 1-4
(Connecting cable supplied with output module).
Connector
O/P Channels
1 - 4
BNC Socket
1
2
3
4
5 – 8
9 – 12
13 – 16
12 / 24Vdc
Supply
210Rx
O/P
13-16
O/P
9-12
O/P
5-8
O/P
1-4
Technical Specifications
Connects to any
Output Module
Dimensions: Within DIN Rail: 138 x 82 mm (PCB: 133 x 72mm)
Storage Temperature: -10 to +70o Celsius.
0 to +55o Celsius.
Operating Temperature:
Electrical Characteristics
Supply Voltage: 12V Supply
Supply Voltage: 24V Supply
Supply Current : Quiescent
Min
10
21
Typical
12
Max
16
30
Units
V
V
24
25
mA
Time from Tx Switch depressed to 210Rx output
Time from Tx Switch release to Decoder output
Switched output Voltage (I out = 1mA)
Logic Low
100
200
mSecs
mSecs
0
3.5
0.2
3.8
0.8
5
V
V
Logic High
Part Numbering
Part No
Description
Receiver Decoder 16 Channels DIN Rail Mounting, FM @ 433.92MHz
210-433FR
210-525NR
210-458FR
Receiver Decoder 16 Channels DIN Rail Mounting, FM Narrow Band @
434.525MHz
Receiver Decoder 16 Channels DIN Rail Mounting, FM High Power @ 458.850MHz
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 9
Modular Radio Telemetry System
200 Series
Output Modules
211 Darlington Output
•
•
•
•
16 transistor switch outputs
Switched
Outputs 1-4
Ground
Connections
Switched
Outputs 9-12
Each Output switches to GND when operated
Each output rated 500mA at up to 50Vdc
Total cumulative output of module 1A @50Vdc
210 Rx
211
The only connections required are
Switched
Outputs 13-16
Switched
Outputs 5-8
•
Screw terminals to connect to each channel
output.
•
Direct connection to the 210 Receiver via the four ribbon cables / connectors supplied.
Dimensions: Within DIN Rail: 70 x 82mm (PCB: 64 x 72mm)
Storage Temperature: -10 to +70o Celsius.
Electrical Characteristics
Supply Voltage
Operating Temperature: 0 to +55o Celsius.
Min
Typical
Max
Units
From 210Rx module
Output voltage
50
VDC
Continuous current Load:
Per Channel
Total module
500
1,000
mA
mA
‘215’ Relay Output Module
•
•
8 relay switches rated 230Vac at 5A
Each relay provides ‘input’ and ‘normally open’ screw
terminals
Relay Outputs 1 - 4
210 Rx
The only connections required are
•
Connection to the 210 Receiver via the ribbon cable
supplied.
215
•
Connection to each relay via screw terminals provided.
Relay Outputs 5 - 8
Dimensions: Within DIN Rail: 93 x 82 mm (PCB: 90 x 72mm)
Storage Temperature: -10 to +70o Celsius.
Electrical Characteristics
Supply Voltage
Operating Temperature: 0 to +55o Celsius.
Min
Typical
Max
Units
From 210Rx module
Relay* output Rating
Type HRS1KH3-12
Max rating is 3A/220VAC/30VDC
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 10
Modular Radio Telemetry System
200 Series
216 Relay Output Module
210 Rx
•
•
4 relay outputs rated at 230Vac ,12A
peak and 5A continuous current rating.
‘normally open’ and ‘normally closed’
screw terminals.
216
Relay Outputs 1 - 4
Dimensions: Within DIN Rail: 135 x 82 mm (PCB: 132 x 72mm)
Storage Temperature: -10 to +70o Celsius.
Electrical Characteristics
Operating Temperature: 0 to +55o Celsius.
Min
Typical
Max
Units
Supply Voltage
Relay* output Rating (type KB12) at 230Vac
From 210Rx module
5
12
A
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
230 Relay Output Module
210 Rx
•
•
4 relay (type K7SFA12) outputs rated
for up to 30A at 230Vac.
Each relay provides ‘input’ and
‘normally open’ Spade Terminals.
230
Relay Outputs 1 - 4
Dimensions: Within DIN Rail: 115 x 82 mm (PCB: 109 x 72mm)
Storage Temperature: -10 to +70o Celsius.
Operating Temperature: 0 to +55o Celsius.
Electrical Characteristics
Min
Typical
Max
Units
Supply Voltage
From 210Rx module
Relay output Rating @ 230Vac*
@ 12Vdc
30
20
A
A
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate, South Street, Lewes,
E Sussex, BN8 6JL. England
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
Email sales@rfsolutions.co.uk
http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions products as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March ’06
©2005 RF Solutions Ltd, www.rfsolutions.co.uk
Tel 01273 898000 Fax 01273 480661
Page 11
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00252/img/page/230-001P21-1_1525778_files/230-001P21-1_1525778_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00252/img/page/230-001P21-1_1525778_files/230-001P21-1_1525778_2.jpg)
230-001FT11-98PN
MIL Series Connector, 6 Contact(s), Carbon Steel, Male, Solder Terminal, Receptacle
GLENAIR
![](http://pdffile.icpdf.com/pdf2/p00252/img/page/230-001P21-1_1525778_files/230-001P21-1_1525778_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00252/img/page/230-001P21-1_1525778_files/230-001P21-1_1525778_2.jpg)
230-001FT15-97PN
MIL Series Connector, 12 Contact(s), Carbon Steel, Male, Solder Terminal, Receptacle
GLENAIR
![](http://pdffile.icpdf.com/pdf2/p00252/img/page/230-001P21-1_1525778_files/230-001P21-1_1525778_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00252/img/page/230-001P21-1_1525778_files/230-001P21-1_1525778_2.jpg)
230-001FT17-99PA
MIL Series Connector, 23 Contact(s), Carbon Steel, Male, Solder Terminal, Receptacle
GLENAIR
©2020 ICPDF网 联系我们和版权申明