VT-UIPM-441-H [REDLION]
Industrial RTU;![VT-UIPM-441-H](http://pdffile.icpdf.com/pdf2/p00345/img/icpdf/VT-UIPM-431-_2128193_icpdf.jpg)
型号: | VT-UIPM-441-H |
厂家: | ![]() |
描述: | Industrial RTU |
文件: | 总2页 (文件大小:492K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MICRO-Versa TRAK µlPm™
Sixnet Automation Devices
Industrial RTU
PRODUCT HIGHLIGHTS
Plant floor interface for Real-time inventory management,
Remote process monitoring, HVAC & energy management,
environmental monitoring, low cost OEM applications
Ideal for ID tag applications, serial ports link to code readers
Datalogging and timestamping trending, alarm logging, &
transaction recording
Stand alone control of remote sites, IEC 61131 ISaGRAF and
also C++ programming via open source Linux
Limitless multi-user connectivity telephone, Internet, and
wireless telemetry, 10/100 Ethernet plus up to 4 com ports
Embedded Linux open source software, add applications,
I/O drivers & much more
An OEM’s dream platform, pre-certified, add your application
PERFORMANCE SPECIFICATIONS
Industrial PowerPC (32 bit data bus)
Operating system embedded open-source Linux
Dynamic memory (RAM) 16 Mbytes for program execution,
dynamic variables, dynamic file system, etc.
Fast ON/OFF delay 4 mS (100 Hz max. counting)
Count rate (see above) (10 KHz on channel 1 only)
Counter modes pulse, rate and run time
Polltime(allchannels)5mSto20mSconfigurationdependent
Program memory (Flash) 16 Mbytes for Linux OS, program
storage and file system
DISCRETE OUTPUTS
4 channels – sourcing 10-30 VDC
Min. & max. output load 1 mA to 1 Amp sourcing per channel
Max. OFF state leakage 0.05 mA
Inrush current 5 Amps (100 mS surge)
Typical ON characteristics 0.3 Ohms resistance and 0.3 VDC
voltage drop @ 1A
Polltime(allchannels)5mSto20mSconfigurationdependent
Retained memory (RAM) 512K (battery-backed) for
datalogging and retained variables
Real-time clock battery-backed for time stamping and other
operations
Local I/O (on-board) 12 or 14 (see ordering info.)
I/O Expansion (up to 256) RS485 or Ethernet
Datalogging support
IEC 61131 programming, ISaGRAF for ladder logic, SFC,
ANALOG INPUTS
2 channels – current or voltage selectable
Full scale range 4-20 mA or 0-5 VDC (jumper selectable)
A/D and input resolution 16 bits (0.003%); 2 uA(current range)
or 0.5 mV (voltage range)
flow charting and more (6 languages supported)
High Level C programming
ETHERNET PORT
Full scale accuracy +/-0.1% (@20°C) (factory calibration)
Span & offset temp. coeff. +/-50 ppm per C
10/100BaseTx (auto-detecting)
°
Input impedance 100 Ohm (current range), 80 K Ohm voltage
Current protection Self-resetting fuses (for 4-20 mA range)
DMRR 66 dB at 50/60 Hz (differential mode rejection)
Fastest update time 50 mS (both channels) – configurable for
longer integration times for better noise filtering
RJ45 connection (auto-crossover)
Protocols TCP/IP, ARP, UDP, ICNP, DHCP, Modbus/TCP,
Sixnet, optionally PPP, DNP3 and more
SERIAL PORT
Up to 115,200 baud
RS485 Port A screws (485+, 485-, GND) (2-wire half-duplex)
RS232PortBRJ45(TD, RD, CTS, RTS, CD, DTR, DSR, GND)
RS232 Port C Screws (TD, RD, RTS, GND)
RS232 Port D (optional) Screws (TD, RD, GND) – In place of
the two analog inputs
Protocols Master & slave modes; Sixnet & Modbus RTU/
ASCII; Others available as Linux applications
ENVIRONMENTAL
DIN rail or flat panel mount
Input power 10-30 VDC
Input current 100 mA @ 24 VDC (typical)
Temperature -40 to 70°C (-40 to 85°C storage)
Humidity 5% to 95% RH (non-condensing)
Flammability UL 94V-0 materials
Electrical safety UL 508, CSAC22.2/14; EN610101; (IEC1010)
DISCRETE INPUTS
EMI emissions FCC part 15, ICES-003, Class A; EN55022;
8 channels sourcing or sinking (jumper/software selectable)
Guaranteed ON voltage 9 VDC (The threshold is factory
adjustable to turn on at a lower voltage – contact Sixnet)
Maximum voltage 30 VDC
Guaranteed OFF voltage 5.0 VDC & 1.5 mA DC
Input resistance & current 10K Ohms and 3 mA @ 24 VDC
EN61326-1
EMC immunity EN61326-1 (EN61000-4-2,3,4,6)
Vibration IEC68-2-6000
Hazardous locations (Class 1, Div 2, Groups A,B,C,D) UL
1604, CSA C22.2/213, Cenelec EN50021 Zone 2
Filtered ON/OFF delay 25 mS (20 Hz max. counting) for
contact bounce filtering
All specifications are subject to change. Consult factory for latest info.
MICRO-Versa TRAK µlPm™ Specifications
MECHANICAL DIMENSIONS
WIRING
ORDERING INFORMATION
Model
DI
8
DO
4
AI
2
RS232
RS485
Ethernet
10/100
VT-UIPM-431-H
VT-UIPM-441-H
2
3
1
1
8
4
0
10/100
As the global experts in communication, monitoring and control for
industrial automation and networking, Red Lion has been delivering
innovative solutions for over forty years. Our award-winning
technology enables companies worldwide to gain real-time data
visibility that drives productivity. Product brands include Red Lion,
N-Tron and Sixnet. With headquarters in York, Pennsylvania, the
company has offices across the Americas, Asia-Pacific and Europe.
For more information, please visit www.redlion.net. Red Lion is a
Spectris company.
Americas
sales@redlion.net
Asia-Pacific
asia@redlion.net
Europe
Middle East
Africa
w w w . r e d l i o n . n e t
europe@redlion.net
Connect. Monitor. Control.
ADLD0235 071713 ©2013 Red Lion Controls
+1 (717) 767-6511