SH2 [RECTRON]
SURFACE MOUNT HIGH EFFICIENCY RECTIFIER VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere; 表面贴装高效率整流电压范围50到600伏特电流1.0安培型号: | SH2 |
厂家: | RECTRON SEMICONDUCTOR |
描述: | SURFACE MOUNT HIGH EFFICIENCY RECTIFIER VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere |
文件: | 总5页 (文件大小:392K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SH1
THRU
SH6
SURFACE MOUNT HIGH EFFICIENCY RECTIFIER
VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere
FEATURES
* Low power loss, high efficiency
* Low leakage
* Low forward voltage
* High current capability
* High speed switching
* High surge capability
* High reliability
SOD-123F
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
* Mounting position: Any
.114 (2.9)
.106 (2.7)
* Weight: 0.016 gram
.077 (1.95)
.035 (0.90)
.028 (0.70)
.069 (1.75)
.008 (0.20)
.053 (1.35)
.047 (1.20)
.030 (0.75)
.022 (0.55)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.150 (3.8)
.142 (3.6)
Dimensions in inches and (millimeters)
O
MAXIMUM RATINGS (@ T
A
=25 C unless otherwise noted)
SYMBOL
VRRM
SH1
50
SH2
100
70
SH3
200
140
200
SH4
300
210
300
SH5
400
280
400
SH6
600
420
UNITS
Volts
Volts
Volts
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
VRMS
35
VDC
IO
IFSM
50
100
Maximum DC Blocking Voltage
600
Maximum Average Forward Rectified Current
1.0
20
Amps
Amps
O
at T = 55 C
A
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 1)
Typical Thermal Resistance (Note 1)
Typical Junction Capacitance (Note 2)
Operating Temperature Range
R
130
30
0C/W
0C/W
pF
θ
θ
J A
J L
R
CJ
TJ
15
12
0 C
150
Storage Temperature Range
TSTG
-55 to + 150
0 C
O
ELECTRICAL CHARACTERISTICS(@T
A
=25 C unless otherwise noted)
CHARACTERISTICS
SYMBOL
VF
SH1
SH2
1.0
SH3
SH4
SH5
SH6
1.7
UNITS
Volts
µA
Maximum Instantaneous Forward Voltage at 1.0A DC
1.3
@TA = 25oC
@TA = 100oC
Maximum Average Reverse Current
5
IR
at Rated DC Blocking Voltage
100
µA
Maximum Reverse Recovery Time (Note 4)
50
75
nSec
trr
2006-12
NOTES : 1. Thermal Resistance :Mounted on PCB.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. "Fully ROHS compliant","100% Sn plating (Pb-free)".
4. Test Conditions: I = 0.5A, I = -1.0A, I = -0.25A.
RR
F
R
RATING AND CHARACTERISTICS CURVES ( SH1 THRU SH6 )
trr
+0.5A
50 Ω
NONINDUCTIVE
10 Ω
NONINDUCTIVE
( - )
PULSE
GENERATOR
(NOTE 2)
D.U.T
0
( + )
25 Vdc
(approx)
( - )
-0.25A
1
( + )
OSCILLOSCOPE
(NOTE 1)
NON-
INDUCTIVE
NOTES:
1
Rise Time = 7ns max. Input Impedance =
1 megohm. 22pF.
-1.0A
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
1cm
SET TIME BASE FOR 20/1 ns/cm
FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
1.0
1000
0.8
0.6
0.4
T
= 100 OC
100
10
A
T
= 75 OC
A
T
= 25 OC
A
Single Phase
Half Wave 60Hz
Resistive or
1.0
0.1
0.2
0
Inductive Load
0
25
50
75
100
125
150
175
0
20
40
60
80
100
120
140
AMBIENT TEMPERATURE, (OC)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.2 TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.3 TYPICAL REVERSE
CHARACTERISTICS
RATING AND CHARACTERISTICS CURVES ( SH1 THRU SH6 )
20
10
20
10
8.3ms Single Half Sine-Wave
(JEDED Method)
T
= 25 OC
J
3.0
1.0
SH1~SH3
SH4~SH5
SH6
5
0.3
0.1
3
2
0.03
0.01
Pulse Width=300uS
1% Duty Cycle
1
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
1
5
10
50
100
INSTANTANEOUS FORWARD VOLTAGE, (V)
NUMBER OF CYCLES AT 60Hz
FIG.4 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
200
100
T
= 25 OC
J
60
40
SH1~SH5
20
10
SH6
6
4
2
1
0.1 0.2
0.4
1.0
2
4
10
20
40
100
REVERSE VOLTAGE, (V)
FIG.6 TYPICAL JUNCTION CAPACITANCE
Mounting Pad Layout
0.030 MIN.
(0.75 MIN.)
0.035MIN.
(0.90 MIN.)
0.165
(4.19) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-