RHV2-1224S/R20 [RECOM]
2 Watt SIP16 Single and Dual Output;型号: | RHV2-1224S/R20 |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 2 Watt SIP16 Single and Dual Output |
文件: | 总5页 (文件大小:1805K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 12.5kVAC/1 minute isolation
• Compact SIP16 case with >30mm pin separation
DC/DC Converter
• Low 4pF max. isolation capacitance
• Wide operating temperature range from
-40°C to +85°C at full load
• Efficiency up to 81%
RHV2
Description
2 Watt
SIP16
Single and Dual
Output
The RHV2 is a DC/DC converter with exceptionally high 20kVDC (12.5KVAC/1 minute) isolation in a
compact SIP16 case. Input voltages can be 5, 12 or 24VDC and outputs 5V, 12V, 24V, 5V or 12V.
The operating temperature is -40°C to +85°C without derating. Applications include high vacuum
monitoring, X-Ray equipment, HVAC dust extraction systems and other high voltage industrial
applications where a very high isolation remote power supply is required.
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load (2)
[µF]
RHV2-0505S/R20
RHV2-0512S/R20
RHV2-0524S/R20
RHV2-1205S/R20
RHV2-1212S/R20
RHV2-1224S/R20
RHV2-2405S/R20
RHV2-2412S/R20
RHV2-2424S/R20
RHV2-0505D/R20
RHV2-0512D/R20
RHV2-1205D/R20
RHV2-1212D/R20
RHV2-2405D/R20
RHV2-2412D/R20
5
5
12
24
5
400
167
84
74
77
81
75
76
77
76
81
78
74
75
74
76
77
81
1000
330
100
1000
330
100
660
330
100
680
150
680
150
680
150
5
5
12
12
12
24
24
24
5
400
167
84
12
24
5
400
167
84
12
24
5
200
84
5
12
5
12
12
24
24
200
84
12
5
200
84
IEC/EN62368-1 certified
IEC/EN61010-1 certified
12
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: The capacitive load is tested at minimum input and constant resistive load
Model Numbering
RHV2-__ __ /R20
Isolation Voltage
Output Power
Single or Dual Output
nom. Input Voltage
Output Voltage
www.recom-power.com
REV.: 0/2019
ECO-1
RHV2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Input Voltage Range
Minimum Load
capacitors
10ꢀ
0ꢀ
Internal Operating Frequency
Output Ripple and Noise (3)
20kHz
45kHz
20MHz BW
150mVp-p
200mVp-p
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
RHV2-0524S/R20
RHV2-2424S/R20
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
ꢆutput ꢇoad ꢃꢄꢅ
ꢆutput ꢇoad ꢃꢄꢅ
RHV2-1212D/R20
RHV2-2412D/R20
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
ꢆutput ꢇoad ꢃꢄꢅ
ꢆutput ꢇoad ꢃꢄꢅ
www.recom-power.com
REV.: 0/2019
ECO-2
RHV2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Condition
Value
5.0ꢀ max.
low line to high line, full load
1.2ꢀ of 1.0ꢀ Vin typ.
12Vout, 24Vout
5Vout
10.0ꢀ max.
15.0ꢀ max.
Load Regulation(4)
Cross Regulation
10ꢀ to 100ꢀ load
10ꢀ to 100ꢀ load
7.5ꢀ typ.
Notes:
Note4: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
Tolerance Envelope
RHV2-0524S/R20
RHV2-2424S/R20
+10%
+10%
+5.5%
+5%
+5%
+4%
Vnom
Vnom
-0.5%
-5%
-1%
-5%
10
50
100
10
50
100
ꢀutput ꢅoad ꢂꢃꢄ
ꢀutput ꢅoad ꢂꢃꢄ
RHV2-1212D/R20
RHV2-2412D/R20
+10%
+6%
+10%
+5%
+5%
+4%
Vnom
Vnom
-1%
-5%
-3%
-5%
10
50
100
10
50
100
ꢀutput ꢅoad ꢂꢃꢄ
ꢀutput ꢅoad ꢂꢃꢄ
PROTECTIONS
Parameter
Type
Value
tested for 1 second
tested for 1 minute
20kVDC
12.5kVAC
Isolation Voltage(5)
I/P to O/P
Isolation Resistance
Isolation Capacitance
Insulation Grade
15GW min.
3.5pF typ./ 4pF max.
reinforced
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 0/2019
ECO-3
RHV2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
Value
-40°C to +85°C
5000m
Operating Temperature Range
Operating Altitude
Operating Humidity
Pollution Degree
Vibration
without derating @ natural convection 0.1m/s (see graph)
non-condensing
5ꢀ - 95ꢀ RH max.
PD2
MIL-STD-202G
+25°C
according to MIL-HDBK-217F,G.B.
+85°C
14600 x 103 hours
5400 x 103 hours
MTBF
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110
85
ꢅmbient ꢆemperature ꢂꢇCꢄ
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
IEC62368-1:2014 2nd Edition
EN62368-1:2014+AC:2015
WD-SE-R-190305-A0
Safety requirements for electrical equipment for measurement, control
and laboratory use - Part 1: General requirements
IEC61010:2010
EN61010:2010
WD-SE-R-190305-B0
RoHS 2
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment –
Emission Requirements
refer to “EMC Filtering”
EN55032, Class B
Information technology equipment - Immunity characteristics - Limits
and methods of measurement
EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Air: 2, 4, 8kV, Contact: 2, 4kV
3V/m
IEC61000-4-2:2009, Criteria A
IEC61000-4-3:2006+A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
DC Power Port: 0.5kV, 1kV
DC Power (Output) Port: 0.5kV
DC Power (Output) Port: 3V
50Hz, 1A/m
Surge Immunity
IEC61000-4-5:2014+A1:2017, Criteria A
IEC61000-4-6:2013+C1:2015, Criteria A
IEC61000-4-8:2010, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
continued on next page
www.recom-power.com
REV.: 0/2019
ECO-4
RHV2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
EMC Filtering Suggestions according to EN55032
Single Output
Dual Output
L1
L1
+Vin
-Vin
ꢂꢁout
+Vin
-Vin
ꢂꢁout
Com
ꢀꢁout
+Vin
+Vout
+Vin
+Vout
Com
C1
C1
-Vin
-Vout
-Vin
-Vout
ꢀꢁout
Component List Class B
nom. Input Voltage
5VDC, 12VDC, 24VDC
C1
L1
10µF, 50VDC MLCC
18µH choke RLS-226
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
PCB
Value
black plastic, (UL94V-0)
FR4, (UL94V-0)
Material
potting
epoxy, (UL94V-0)
Package Dimension (LxWxH)
Weight
45.0 x 15.0 x 17.0mm
19.7g typ.
Dimension Drawing (mm)
Pinning Information
Pin # Single
embossed logo
Dual
+Vin
-Vin
1
2
+Vin
-Vin
45.0
ꢀ5.0
14
15
16
-Vout
no pin
+Vout
-Vout
Com
+Vout
Marking
Tolerance:
xx.x= 0.5mm
xx.xx= 0.25mm
0.ꢀ0
0.ꢀ0
0.25
0.5
Recommended Footprint Details
ꢀ ꢁ
ꢀꢂꢀꢄꢀꢃ
ꢅottom ꢆieꢇ
ꢈop ꢆieꢇ
ꢀ ꢁ
ꢀꢂꢀꢄꢀꢃ
3.45
ꢀ2 x 2.54 = 30.48
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
Packaging Quantity
tube
520.0 x 26.9 x 17.9mm
10pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
5ꢀ - 95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2019
ECO-5
相关型号:
©2020 ICPDF网 联系我们和版权申明