REC20-125.1S [RECOM]
20 Watt Single and Dual Output;型号: | REC20-125.1S |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 20 Watt Single and Dual Output |
文件: | 总6页 (文件大小:356K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 6-Side Shielding
Features
• External ON/OFF control
• 1.6kVDC Isolation
DC/DC Converter
• UL/CSA/EN-60950-1 Certified
• 2:1 Input Voltage Range
• Continuous Short Circuit Protection
• Efficiency up to 90.5%
• Fixed Switching Frequency
Regulated
Converters
REC20
Description
20 Watt
The REC20-xxxxS_D-series offer single and dual regulated outputs in a 2”x1” package with 1.6kVDC
isolation and are suitable for higher power industrial applications. Remote on/off control is standard.
The higher current outputs have raised output voltages to compensate for track losses as standard. The
converter is fully certified to UL/EN/IEC safety standards.
2“ x 1“
Single and Dual
Output
Selection Guide
Part
Number
Input
Voltage Range
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
typ.
max. Capacitive
Load
(µF)
(%)
REC20-123.4S
REC20-125.1S
REC20-1212S
REC20-1215S
REC20-1212D
REC20-1215D
REC20-243.4S
REC20-245.1S
REC20-2412S
REC20-2415S
REC20-2412D
REC20-2415D
REC20-483.4S
REC20-485.1S
REC20-4812S
REC20-4815S
REC20-4812D
REC20-4815D
9-18
9-18
3.4
5.1
12
15
12
15
3.4
5.1
12
15
12
15
3.4
5.1
12
15
12
15
5000
4000
1670
1340
835
85
89
10000
6800
1800
1000
800
9-18
88.5
88.5
89
9-18
9-18
9-18
670
89
500
18-36
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
36-75
5000
4000
1670
1340
835
86
10000
6800
1800
1000
800
90
89
90
89.5
89.5
86.5
89
670
500
5000
4000
1670
1340
835
10000
6800
1800
1000
800
E224736
89
90
89.5
90.5
670
500
IEC/EN60950-1 Certified
UL60950-1 Certified
CSA C22.2 NO. 60950 Certified
EN55022 Certified
Model Numbering
REC20-__ __ _
Single or Dual
nom. Input Voltage
Output Voltage
Ordering Examples:
REC20-4812S, Single Output, 36-75Vin and 12Vout
REC20-2412D, Dual Output, 18-36Vin and 12Vout
www.recom-power.com
REV.: 1/2016
ECO-1
REC20
DC/DC Converter
Specifications (measured at T = 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
a
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin= 12V
nom. Vin= 24V
nom. Vin= 48V
9VDC
18VDC
36VDC
18VDC
36VDC
75VDC
Input Voltage Range
Start/up Time
10ms
DC-DC ON
DC-DC OFF
8.6VDC
7.8VDC
nom. Vin= 12V
nom. Vin= 24V
nom. Vin= 48V
DC-DC ON
DC-DC OFF
17.6VDC
16.8VDC
Under Voltage Lockout
Remote ON/OFF
DC-DC ON
DC-DC OFF
34.6VDC
33.8VDC
DC-DC ON
DC-DC OFF
Open or 3V<Vr<12V
Short or 0V<Vr<1.2V
350kHz
0ꢀ
Operating Frequency
Minimum Load
Output Ripple and Noise (1)
100mVp-p
Notes:
Note1: Ripple and Noise is measured with a 20MHz bandwidth and a 0.1µF ceramic capacitor.
Efficiency vs. Load
REC20-485.1S
REC20-2415S
95
90
85
80
75
70
65
60
55
95
90
85
80
75
70
36V
54V
75V
18V
24V
36V
0
0.5
1
1.5
2
2.5
3
3.5
6
0
0.13 0.27 0.40 0.54 0.67 0.80 0.94 1.07 1.21 1.34
Output Current (A)
Output Current (A)
REGULATIONS
Parameter
Condition
Type
Values
1ꢀ typ. / 1.5ꢀ max.
10ꢀ typ.
Output Voltage Accuracy
Voltage Adjustability
Line Voltage Regulation
Load Voltage Regulation
Cross Regulation
low line to high line, full load
10ꢀ to 100ꢀ load
0.2ꢀ max.
0.5ꢀ max.
25ꢀ to 100ꢀ load
dual output
5ꢀ max.
Transient Response Recovery Time
25ꢀ load step change
250µS typ.
continued on next page
REV.: 1/2016
ECO-2
www.recom-power.com
REC20
DC/DC Converter
Specifications (measured at T = 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
a
Series
Deviation vs. Load
REC20-485.1S
REC20-2415S
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0
36V
48V
75V
18V
24V
36V
0
1
2
2
3
4
5
5
6
0
0.13 0.27 0.40 0.54 0.67 0.80 0.94 1.07 1.21 1.34
Output Current (A)
Output Current (A)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
3.4Vout
5.1Vout
12Vout
15Vout
3.9VDC typ.
6.2VDC typ.
15VDC typ.
18VDC typ.
Over Voltage Protection (OVP)
Zerner Diode Clamp
Over Load Protection (OLP)
Isolation Voltage
140ꢀ typ.
1.6kVDC / 1 minute
1000pF typ.
I/P to O/P
Isolation Capacitance
Isolation Resistance
1GΩ min.
ENVIRONMENTAL
Parameter
Condition
with derating
Value
-40°C to +100°C
+100°C
Operating Temperature Range
Maximum Case Temperature
Temperatur Coefficient
Thermal Impedance
Operating Altitude
Operating Humidity
Vibration
0.05ꢀ/°C typ.
12°C/W
natural convection
non-condensing
5000m
5ꢀ - 95ꢀ RH max.
MIL-STD-202G
607 x 10³ hours
MTBF
according to MIL-HDBK-217F, 25°C, referring to REC20-125.1S
continued on next page
REV.: 1/2016
www.recom-power.com
ECO-3
REC20
DC/DC Converter
Specifications (measured at T = 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
a
Series
Derating Graph
@ nominal input voltage, full load and natural convection (20LFM)
REC20-485.1S
REC20-2415S
100
80
100
80
60
40
20
0
60
50
40
20
0
Safe Operating Area
Safe Operating Area
-40
-20
0
20
40
60
80
100
120
-40
-20
0
20
40
60
80
100
120
75 90
75 85 95
Ambient Temperature (°C)
Ambient Temperature (°C)
Notes:
Note2: For more details, please contact our technical support service at TechsupportAT@recom-power.com
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
E224736
Standard
CB General Safety
IEC60950-1, 2nd Edition, 2013
UL60950-1, 2nd Edition, 2014
EN60950-1, 2nd Edition, 2013
C22.2 No. 60950-1-07, 2014
UL General Safety
E224736
EN General Safety
E224736
CAN/CSA General Safety
E224736
EMC Compliance
EMI
Condition
with external filter (see filter suggestions)
Standard / Criterion
EN55022, Class A,B
ESD
Air: 8kVꢁ Contact: 4kV
EN61000-4-2, Criteria B
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
Radiated Immunity
Fast Transient
Surge (3)
10V/m
1kV
1kV
Conducted Immunity
Power Magnetic Field
10Vr.m.s
50Hz 1A/m (r.m.s)
Notes:
Note3: An external MOV is required if the module has to meet EN61000-4-5. The MOV suggest: NichTek SVI32-380
EMC Filtering - Suggestions for Class A
+Vin
+Vout
Com
L1
DC
C1
C2
DC
-Vin
-Vout
MODEL
C1
C2
L1
REC20-12xxS(D)
REC20-24xxS(D)
REC20-48xxS(D)
4.7µF/50V
4.7µF/50V
2.2µF/100V
NA
0.45mH
0.45mH
0.45mH
NA
2.2µF/100V
continued on next page
REV.: 1/2016
ECO-4
www.recom-power.com
REC20
DC/DC Converter
Specifications (measured at T = 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
a
Series
EMC Filtering - Suggestions for Class B
C4
L1
+Vin
+Vout
DC
C1
C2
Com
DC
-Vin
-Vout
C3
MODEL
C1
C2
L1
C3
C4
REC20-12xxS(D)
REC20-24xxS(D)
REC20-48xxS(D)
10µF/50V
10µF/50V
0.45mH
0.45mH
0.67mH
1nF/2kV
1nF/2kV
3.3nF/2kV
1nF/2kV
1nF/2kV
3.3nF/2kV
4.7µF/50V
NA
2.2µF/100V
4.7µF/100V
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Case
Base
Potting
Nickel plated copper
non conductive black plastic
(UL94V-0) Epoxy
Material
Package Dimension (LxWxH)
Package Weight
50.8 x 25.4 x 10.2mm
27g
Dimension Drawing (mm)
Pin Connections
Pin # Single
50.8
Dual
+Vin
-Vin
1
+Vin
-Vin
2
3
4
5
6
+Vout
Trim
-Vout
+Vout
Com
-Vout
Remote On/Off
Tolerance: xx.x=
xx.xx=
Pin:
0.5mm
0.35mm
0.05mm
15.24
20.32
15.24
Ø1.0
2.54
3
4
5
1
2
6
www.recom-power.com
REV.: 1/2016
ECO-5
REC20
DC/DC Converter
Specifications (measured at T = 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
a
Series
INSTALLATION and APPLICATION
External Output Voltage Trimming
Trim up
Trim down
+Vout
R1
R1
Trim
Rd
R3
R3
V
ref
V
ref
RU
Trim
R2
R2
-Vout
aR2
R2-a
Vref
Vó - Vref
bR1
R1-b
Vref
Vó - Vref
RU =
- R3
a =
x R1
Rd =
- R3
b =
x R2
Output
Voltage
3.4V
5.1V
12V
15V
Notes:
R1
R2
2.1K
1.2K
4.7K
2.21K
2.1K
8.87K
2.4K
15K
6.04K
1.2K
Note4:
RU and Rd is mean trim resistor, please check the formula.
a & b: user define parameter, no actual meanings.
Vó is mean trim up/down voltage.
Note5:
Note6:
Note7:
Value for R1, R2, R3 and Vref refer to table.
R3
7.32K
2.5V
9.76K
2.5V
Vref
1.24V
2.5V
PACKAGING INFORMATION
Packaging Dimension (LxWxH)
Packaging Quantity
Tube
520.0 x 54.5 x 21.0mm
18pcs
Storage Temperature Range
-55°C to +125°C
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
ECO-6
REV.: 1/2016
www.recom-power.com
相关型号:
©2020 ICPDF网 联系我们和版权申明