RACM550-56SG [RECOM]

550 Watt 5” x 3” Open Frame or Enclosed Single Output;
RACM550-56SG
型号: RACM550-56SG
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

550 Watt 5” x 3” Open Frame or Enclosed Single Output

文件: 总10页 (文件大小:1508K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 300W baseplate-cooled, fan-less operation  
• 550W peak power or forced air rating  
• Industrial, household and medical 2MOPP ready  
• Standby power consumption <0.5W  
Features  
AC/DC Converter  
Regulated  
Converter  
• Operating temperature -40°C to +70°C  
• Signals: remote sensing and ON/OFF control  
RACM550-G  
Description  
550 Watt  
5” x 3”  
Open Frame or  
Enclosed  
Single Output  
The RACM550 Series is designed to support up to 300 Watt continuous output power without  
fan cooling.The compact 5x 3baseplate design enables direct heat dissipation through metal housings  
in the application. Up to 550 watts are available to drive dynamic loads for several seconds of peak  
power or with forced air for even longer time frames. A smart fan output is on board as standard  
as well as a 5V/1A VSB output for applications with housekeeping circuits and on/off control.  
A wide input range of 80 to 264VAC, up to 5000m operating altitude and international safety  
agency certifications make the series worldwide suitable for BF-rated applied parts, household and  
industrial ITE applications.  
Selection Guide  
Part  
Number  
Input  
Voltage Range  
[VAC]  
Nom. Output  
Voltage  
Max. Output  
Current (1)  
[A]  
Efficiency  
typ. (2)  
[%]  
[VDC]  
RACM550-24SG(3)  
RACM550-36SG(3)  
RACM550-48SG(3)  
RACM550-56SG(3)  
80-264  
80-264  
80-264  
80-264  
24  
36  
48  
56  
22.92  
15.28  
11.46  
9.82  
93  
93  
93  
94  
Notes:  
Note1: With forced air cooling (2.5m/s) + conduction cooling + refer to “Line Derating”  
Note2: Efficiency is tested at nominal input and full load at +25°C ambient  
Model Numbering  
E314885  
RACM550-__ SG/  
(3)  
max. Output Power  
“Case Option ”  
nom. Output Voltage  
Single  
2MOPP  
250VAC  
Notes:  
UL62368-1 (TÜV NRTL) certified  
CAN/CAS C22.2 No. 62368-1 certified  
IEC/EN62368-1 certified  
ANSI/AAMI ES60601-1 certified  
CSA/CAN 22.2 60950-1-14 certified  
IEC/EN60335-1 certified  
IEC/EN60601-1 (pending)  
IEC/EN60950-1 (pending)  
IEC/EN61558-1 (pending)  
IEC/EN61558-2-16 (pending)  
EN55032 compliant  
Note3: add suffix “/OF” for open frame version  
add suffix “/ENC” for enclosed version (MOQ 1000pcs)  
Ordering Examples:  
RACM550-24SG/OF  
24Vout  
Single  
Single  
open frame  
enclosed  
RACM550-36SG/ENC 24Vout  
EN55024 compliant  
CB Report  
www.recom-power.com  
REV.: 0/2020  
PA-1  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Nom. Input Voltage  
100VAC  
240VAC  
80VAC  
120VDC  
264VAC  
370VDC  
Input Voltage Range (4)  
115VAC  
230VAC  
6.5A  
3.0A  
Input Current  
115VAC  
230VAC  
40A  
60A  
Inrush Current  
No load Power Consumption  
Standby Power  
2W  
main output OFF, VSB Output unloaded  
AC input  
0.5W  
63Hz  
Input Frequency Range  
47Hz  
0%  
ErP Lot 6 Standby Mode Conformity  
(VSB Output Load Capability)  
Input Power= 1W (main output= standby mode)  
450mW  
Minimum Load  
115VAC  
230VAC  
0.98  
0.95  
0.99  
0.97  
Power Factor  
main output  
VSB Output  
115VAC/230VAC  
115VAC/230VAC  
400ms  
140ms  
Start-up Time  
Rise Time  
main output  
VSB Output  
115VAC/230VAC  
115VAC/230VAC  
15ms  
5ms  
main output  
VSB Output  
115VAC/230VAC, 550W  
115VAC/230VAC  
15ms  
130ms  
Hold-up Time  
1% of Vout nom. max.  
120mVp-p  
main output  
VSB Output  
Output Ripple and Noise(5)  
20MHz BW @ 25°C  
Notes:  
Note4: The products were submitted for safety files at AC-input operation. For DC-input make sure that sufficient fuses are used  
Note5: Measurements are made with a 12“ twisted pair-wire terminated with a 0.1µF and 10µF parallel capacitor  
Efficiency vs. Load  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
REGULATIONS  
Parameter  
Condition  
Value  
main output  
VSB output  
3.0% max.  
4.0% max.  
Output Accuracy  
Line Regulation  
Load Regulation (6)  
low line to high line, full load  
10% to 100% load  
main output / VSB output  
main output / VSB output  
1.0% max.  
1.0% max.  
Notes:  
Note6: Operation below 10% load will not harm the converter, but specifications may not be met  
www.recom-power.com  
REV.: 0/2020  
PA-2  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
ADDITIONAL FEATURES  
Parameter  
Condition  
Min.  
Typ.  
Max.  
CTRL ON  
CTRL OFF  
115VAC/230VAC  
5W  
VSB Output Power  
230VAC  
115VAC  
5W  
1W  
(7)  
Output Voltage Adjustability  
ON/OFF CTRL  
on-board potentiometer  
2VDC  
CON3, Pin3  
main and FAN output ON  
main and FAN output OFF  
2.4VDC - 5VDC or open  
0VDC - 0.8VDC or shorted to GND  
(refer to “VSB & CTRL (CON3)“  
continuous  
peak (1s)  
250mA  
500mA  
Fan Output Power  
Remote Sense (8)  
Power OK LED  
Notes:  
@ +50°C (not protected)  
2VDC  
LED = green  
LED = red  
working  
failure  
Note7: By trimming up, decrease output current to avoid exceeding rated output power. By trimming down, do not exceed maximum continuous output current  
Note8: The output voltage can be adjusted by both ADJ (potentiometer) and Sense. The maximum combined adjustment range is 2VDC  
REMOTE SENSE  
RW1  
+Vout  
+Vout  
VACIN (L)  
PE  
VACin(L)  
VACin(N)  
+Sense  
RW ... wire losses +  
1
RW ... wire losses -  
2
-Sense  
-Vout  
-Vout  
VACIN (N)  
RW2  
PROTECTIONS (Fan output not protected)  
Parameter  
Type  
internal  
Value  
2x T6.3A, slow blow type  
OVCII  
Input Fuse (9)  
Over Voltage Category (OVC)  
Class of Equipment  
Isolation Voltage (safety certified) (10)  
Isolation Resistance  
Insulation Grade  
Class I  
I/P to O/P  
1 minute  
4kVAC  
10Mmin.  
reinforced  
Leakage Current  
0.25mA max.  
2MOPP  
Means of Protection  
250VAC working voltage  
Notes:  
Note9: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type  
Note10: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
PROTECTIONS MAIN OUTPUT  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Current Protection (OCP)  
Over Temperature Protection (OTP)  
below 100mΩ  
Pin =10W max.  
hiccup mode, auto recovery  
110% - 120%, hiccup mode  
105% - 135%, hiccup mode  
auto recovery, internal temperature sensors  
PROTECTIONS AUX (VSB)  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Current Protection (OCP)  
below 100mΩ  
hiccup mode, auto recovery  
8-9VDC, hiccup mode  
2.5-3.5A, hiccup mode  
www.recom-power.com  
REV.: 0/2020  
PA-3  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
Operating Temperature Range  
Temperature Coefficient  
Operating Altitude (11)  
Operating Humidity  
Pollution Degree  
Shock  
refer to derating graphs (valid for /OF and /ENC)  
-40°C to +70°C  
0.02%/K  
5000m  
20% - 90% RH max.  
non-condensing  
PD2  
250m/s², 6ms; 3 times, each along x, y, z axes  
90-200Hz, 10m/s²; 3.5min./1cycle, 5 periods, each along x, y, z axes  
Vibration  
+25°C (forced air cooling)  
+45°C (forced air cooling)  
200 x 103 hours  
50 x 103 hours  
according to MIL-217F Method 2  
Components Stress Method  
MTBF  
Notes:  
Note11: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.  
Please contact RECOM tech support for advice.  
Thermal Derating 115VAC  
Line Derating (<115VAC)  
100  
550  
500  
450  
400  
350  
300  
250  
200  
150  
100  
50  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC, 4.5m/s forced cooling  
115VAC, conduction cooling  
115VAC, convection cooling  
0
-40 -30 -20 -10  
0
10 20 30 40 50 60 70 80  
45  
80 90 100  
115  
Ambient Temperature [°C]  
Input Voltage [VAC]  
Thermal Derating 230VAC  
550  
500  
450  
400  
350  
300  
250  
200  
150  
100  
50  
230VAC, 2.5m/s forced cooling  
230VAC, conduction cooling  
230VAC, convection cooling  
0
-40 -30 -20 -10  
0
10 20 30 40 50 60 70 80  
Ambient Temperature [°C]  
<0.1m/s = still air  
0.1 - 0.2m/s = natural convection  
continued on next page  
REV.: 0/2020  
www.recom-power.com  
PA-4  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
Peak Load Capability  
Pout [W]  
Calculation  
Pnom = nom. output power  
Pp  
[W]  
PP = peak output power (550W) [W]  
Pnom x (t1set + t2) - (PP x t1set  
)
Pr = recovery output power  
t1 = peak time set (10s max.)  
t2 = recovery time (min. 4 x t1)  
[W]  
[s]  
[s]  
[ ]  
Pr =  
t2 x k  
Pnom  
Pr  
k
= safety factor 1.7  
0
Time [s]  
t1  
t2  
Practical Example (RACM550-24SG/OF):  
Take the RACM550-24SG/OF at 100VAC input voltage and TAMB= 60°C (220W) with  
conduction cooling.  
Pnom. = refer to derating graphs= 245W with line derating 220W  
PP = 550W  
220 x (10 + 40) - (550 x 10)  
40 x 1.7  
t1 = 10s  
Pr =  
= 80.9W  
40s  
=
t2  
k
= 1.7  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report / File Number  
Standard  
Audio/video, information and communication technology equipment - Safety requirements (CB)  
IEC62368-1:2014 2nd Edition  
EN62368-1:2014 + A11:2017  
UL62368-1:2014  
211-700545-000  
Audio/video, information and communication technology equipment - Safety requirements  
Audio/video, information and communication technology equipment - Safety requirements  
(TÜV NRTL)  
65.250.19.032.02  
pending  
CAN/CSA C22.2 No.62368-1:2014  
IEC60950-1:2005, 2nd Edition + A2:2013  
EN60950-1:2006 + A2:2013  
Information Technology Equipment, General Requirements for Safety  
Household and similar electrical appliances - Safety - Part 1: General requirements  
EN60335-1:2012 + A11:2014  
SA1904214L 02001  
Measurement methods for electromagnetic fields of household appliances and similar  
apparatus with regard to human exposure  
EN62233:2008  
ANSI/AAMI ES60601-1:2005  
CAN/CSA-C22.2 No. 6060-1:14  
E314885-D1001-1-A0-  
C0-UL  
Medical Electric Equipment, General Requirements for Safety and Essential Performance  
Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB)  
Medical Electric Equipment, General Requirements for Safety and Essential Performance  
IEC60601-1:2005, 3rd Edition + AM1:2012  
EN60601-1:2006 + A12:2014  
pending  
pending  
IEC61558-1:2005, 2nd Edition + A1:2009  
EN61558-1:2005 + A1:2009  
Safety of power transformers, power supplies, reactors and similar products -  
Part 1: General requirements and tests  
Safety of transformers, reactors, power supply units and similar products for supply  
voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode  
power supply units and transformers for switch mode power supply units (CB)  
pending  
pending  
IEC61558-2-16:2009, 1st Edition + A1:2013  
Safety of transformers, reactors, power supply units and similar products for supply  
voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode  
power supply units and transformers for switch mode power supply units (LVD)  
EN61558-2-16:2009 + A1:2013  
RoHS 2011/65/EU + AM2015/863  
RoHS2+  
continued on next page  
www.recom-power.com  
REV.: 0/2020  
PA-5  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
EMC Compliance  
Electromagnetic compatibility of multimedia equipment - Emission requirements  
Electromagnetic compatibility of multimedia equipment - Immunity requirements  
Condition  
without external filter  
Standard / Criterion  
EN55032:2015, Class B  
EN55035:2017  
Information technology equipment - Immunity characteristics -  
Limits and methods of measurement  
EN55024:2010 + A1:2015  
ESD Electrostatic discharge immunity test  
Radiated, radio-frequency, electromagnetic field immunity test  
Fast Transient and Burst Immunity  
Air 8kV, Contact 4kV  
3V/m (80-5000MHz)  
EN61000-4-2:2009, Criteria A  
EN61000-4-3:2006+A2:2010, Criteria A  
EN61000-4-4:2012, Criteria A  
AC Power Port: 1kV  
AC Power Port: L-N 1kV  
Surge Immunity  
EN61000-4-5:2014, Criteria B  
AC Power Port: 3V (0.15-10MHz)  
3V to 1V (10-30MHz)  
1V (30-80MHz)  
Immunity to conducted disturbances, induced by radio-frequency fields  
EN61000-4-6:2014, Criteria A  
Power Magnetic Field Immunity  
Voltage Dips and Interruptions  
Voltage Dips and Interruptions  
Voltage Dips and Interruptions  
Voltage Dips and Interruptions  
Voltage Dips and Interruptions  
Limits of Harmonic Current Emissions  
Limits of Voltage Fluctuations & Flicker  
50Hz/60Hz, 1A/m  
Voltage Dips 100% at 50/60Hz  
Voltage Dips 30% at 50Hz  
Voltage Dips 30% at 60Hz  
Voltage Interruptions > 95% at 50Hz  
Voltage Interruptions > 95% at 60Hz  
Class A  
EN61000-4-8:2010, Criteria A  
EN61000-4-11:2004, Criteria A  
EN61000-4-11:2004, Criteria A  
EN61000-4-11:2004, Criteria B  
EN61000-4-11:2004, Criteria C  
EN61000-4-11:2004, Criteria B  
EN61000-3-2:2014  
Clause 5  
EN61000-3-3:2013  
DIMENSION AND PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
PCB  
FR4, (UL94 V-0)  
aluminium  
Material  
baseplate / case (“/ENC”)  
open frame version  
enclosed version  
127.0 x 76.0 x 38.0mm  
150.0 x 87.0 x 45.0mm  
Dimension (LxWxH)  
open frame version  
enclosed version  
500g typ.  
590g typ.  
Weight  
Dimension Drawing Open Frame (mm)  
127.0  
Cꢂꢃꢇ  
Cꢂꢃꢊ  
Aꢀꢁ  
Top View  
1
3
2
4
Cꢂꢃꢈ  
Cꢂꢃꢉ  
Cꢂꢃꢄ  
Cꢂꢃꢋ  
Cꢂꢃꢌ  
2 1  
ꢅꢆꢀ  
continued on next page  
REV.: 0/2020  
www.recom-power.com  
PA-6  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
Side View  
ꢀirꢁꢂꢃꢄ  
FC 115.8  
FC 5.6  
4 x Ø3.5  
Bottom View  
FC = fixing centers  
Tolerance: xx.x= 1.0mm  
xx.xx= 0.5mm  
Cꢂꢃꢇ  
3
1
4
2
AC side  
DC side  
ꢅꢆꢀ Cꢂꢃꢄ Cꢂꢃꢉ Cꢂꢃꢈ Cꢂꢃꢊ  
Cꢂꢃꢌ  
Cꢂꢃꢋ  
1
3
Aꢀꢁ  
Compatible Connector (valid for open frame and enclosed version)  
PE (CON1) AC Input (CON4)  
# Function Connector # Function Connector # Function Connector # Function Connector # Function Connector  
FAN (CON2)  
VSB & CTRL (CON3)  
Sense (CON6)  
1
2
3
4
+5VSB  
GND  
PS ON 0450 or similar  
GND  
1
2
3
4
-Sense  
NC  
+Sense 0450 or similar  
NC  
TE Connectivity  
PIDG series with  
positive lock .250EX  
1
3
AC/N  
AC/L  
Molex 09-50-  
1031 or similar  
1
2
-FAN  
Molex 22-01-  
Molex 51110-  
Molex 51110-  
1
PE  
+FAN 1022 or similar  
NC= No connection  
MAIN Output Screw Terminal (CON7/8)  
#
Function  
-Vout  
+Vout  
AWG  
14-26  
14-26  
Maximum tightening torque for mounting: 0.3Nm  
FC= fixing centers  
Tolerance: xx.x= 1.0mm  
xx.xx= 0.5mm  
CON7  
CON8  
wire stripping length: 5.0mm  
recommended tightening torque: 0.8Nm  
continued on next page  
www.recom-power.com  
REV.: 0/2020  
PA-7  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
Dimension Drawing Enclosed Version (mm)  
150.0  
Cꢀꢁꢋ  
Cꢀꢁꢌ  
1 2  
Cꢀꢁꢂ  
Top View  
Cꢀꢁꢅ  
Cꢀꢁꢄ  
Cꢀꢁꢆ  
1
3
2
4
Aꢇꢈ  
Ø4.5  
Ø4.5  
embossed logo  
Side View  
5.0  
130.0  
10.0  
FC 134.5  
FC 7.75  
4 x Ø4.5  
Ø4.5  
Bottom View  
FC = fixing centers  
Tolerance: xx.x= 1.0mm  
xx.xx= 0.5mm  
continued on next page  
REV.: 0/2020  
www.recom-power.com  
PA-8  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
Dimension Drawing Enclosed Version (mm)  
3
1
4
2
DC side  
AC side  
Cꢀꢁꢋ  
Cꢀꢁꢌ  
ꢉꢊꢇ  
Cꢀꢁꢂ Cꢀꢁꢅ  
Cꢀꢁꢄ Cꢀꢁꢆ  
1
3
Aꢇꢈ  
INSTALLATION AND APPLICATION  
Mounting  
Forced air conditions as specified are valid for indicated airflow direction only!  
vertical  
horizontal (standard)  
upside down  
AC  
ꢅC  
ꢀirꢁꢂꢃꢄ  
ꢀirꢁꢂꢃꢄ  
AC  
ꢅC  
side  
side  
Notes:  
Note12: If module is horizontal or side mounted no derating is required.  
If module is mounted vertically or upside down with natural convection cooling, the  
power must be derated at least 10%.  
For convection cooling, ensure sufficient distance to adjacent components!  
With forced air cooling, mounting orientation has no impact on output power.  
Device should be fan cooled from DC side.  
If thermal conduction cooling is suggested, use of heat sink compound is recom-  
mended for improved heat transfer via baseplate.  
Block Diagram  
PS ON  
GND  
Isolation  
ADJ  
+Sense  
-Sense  
PFC LLC  
Controller  
Feedback  
and Isolation  
PWM  
Controller  
L
Fuse, Inrush  
Current Linitation,  
Input Filter  
+Vout  
-Vout  
Rectifier +  
Bulk Cap  
Output  
Filter  
Rectifier  
Switcher  
PFC  
Boost  
N
+Fan  
-Fan  
PE  
Rectifier  
Transformer  
Feedback  
and Isolation  
+5VSB  
GND  
Flyback  
Controller  
Output  
Filter  
Rectifier  
Transformer  
www.recom-power.com  
REV.: 0/2020  
PA-9  
RACM550-G  
AC/DC Converter  
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)  
Series  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
open frame version  
enclosed version  
134.0 x 86.0 x 45.0mm  
155.0 x 92.0 x 50.0mm  
Packaging Dimension (LxWxH)  
cardboard box  
Packaging Quantity  
1pcs  
-55°C to +85°C  
95% RH max.  
Storage Temperature Range  
Storage Humidity  
non-condensing  
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOMꢀs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 0/2020  
PA-10  

相关型号:

RACM550-G

550 Watt 5” x 3” Open Frame or Enclosed Single Output
RECOM

RACM60-05SK/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-12SK/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-15SK/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-24SK/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-36SK/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-48SK/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-K

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM60-K/OF

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output
RECOM

RACM65

Suitable for built in Class II Applications
RECOM

RACM65-05S

65 Watt Enclosed & Open Frame Case Style Single Output
RECOM

RACM65-05S-ST

CONV AC/DC 65W 85-264VIN 05VOUT
ETC