PTA2H-1000-DB [RCD]

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, AXIAL LEADED;
PTA2H-1000-DB
型号: PTA2H-1000-DB
厂家: RCD COMPONENTS INC.    RCD COMPONENTS INC.
描述:

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, AXIAL LEADED

传感器 换能器
文件: 总1页 (文件大小:47K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
RESISTORSCAPACITORSCOILSDELAY LINES  
THIN-FILM PLATINUM TEMPERATURE SENSOR  
Term.W  
is RoHS  
compliant  
PT SERIES  
RoHS  
Industry’s lowest cost and widest selection!  
SPECIAL MODIFICATIONS (Consult Factory)  
Non-standard resistance values up to 2000Ω  
Surface Mount chip elements  
Insulated extension wires  
Assembly into stainless steel probes (PTS Series)  
MIL-Spec Group A & B environmental testing  
Precision performance, excellent stability, fast response  
Wide resistance range: 100, 500, 1000Ω  
Dual sensors available in a single package (Type PTD)  
Meets DIN 43760 and IEC 751  
Choice of temperature ratings (up to +640°C)  
TYPE PTF - FLAT ELEMENT  
TYPE PTR - CYLINDRICAL  
TYPE PTA-AXIAL LEAD  
(ceramic encased)  
TYPE PTD - DUAL ELEMENT  
(ceramic encased)  
(ceramic encased)  
H
W
W
W
W
L →  
L →  
L →  
L →  
Dimensions  
Typical Response Time (sec.)  
Water 0.2 m/s Air 1 m/s  
Standard  
Resistance  
Values  
Self Heating  
Air 1m/s  
(°C/mW)  
RCD  
Type  
W ±.016 [.4]  
L ±.02 [.5]  
H Max.  
50%  
90%  
50%  
90%  
NEW→  
PTF1/2 .062 [1.6]  
.125 [3.2]  
.400 [10]  
.100 [2.5]  
.200 [5]  
.047 [1.2]  
.055 [1.4]  
.047 [1.2]  
.055 [1.4]  
100  
100,500,1000  
100  
.08  
.2  
.07  
.1  
.25  
.5  
.2  
4
5
3
5
11  
13  
10  
15  
.17  
.17  
.30  
.25  
PTF1  
PTF4  
PTF5  
.080 [2]  
.080 [2]  
.080 [2]  
100, 500, 1000  
.3  
PTR1  
PTR2  
.125 [3.2]  
.120 [3]  
.530±.062  
.250±.031  
N/A  
N/A  
100,500,1000  
100  
1.5  
1.3  
6
5
20  
15  
66  
50  
.12  
.16  
PTA1  
PTA2  
.125 [3.2]  
.120 [3]  
.600±.04  
.250±.031  
N/A  
N/A  
100,500,1000  
100  
1.5  
1.3  
6
5
20  
15  
66  
50  
.12  
.16  
PTD1  
.170 [4.3]  
.675±.062  
N/A  
2x100, 2x500, 2x1000  
2
8
25  
80  
.12  
RESISTANCEAND INTERCHANGEABILITY  
SPECIFICATIONS  
Operating  
Temperature  
Range  
Tolerance  
Type L: -50 to +200°C (low temp, economy)  
Type H: -50 to +500°C (high temp, industrial)  
Type T: -50 to +640°C(highest temp, specialty)  
°C  
Resistance  
.5 DIN  
±.25°C  
±.15°C  
±.35°C  
±.55°C  
±.75°C  
±.95°C  
±1.15°C  
DIN  
1.5 DIN  
2 DIN  
±1.1°C  
±.6°C  
-50  
0
.803  
1.000  
1.385  
1.758  
2.120  
2.470  
2.809  
±.55°C  
±.3°C  
±.85°C  
±.45°C  
±1.2°C  
±2.0°C  
±2.7°C  
±3.5°C  
±4.2°C  
TCR (0°C to 100°C)  
Stability  
+3850ppm/°C  
<0.1°C typ. drift after 1000 hours at Max Temp  
10MMin. @ 25°C, 1 MMin. @ Max. Temp.  
<10 pF  
+100  
+200  
+300  
+400  
+500  
±.8°C  
±1.6°C  
±2.6°C  
±3.6°C  
±4.6°C  
±5.6°C  
±1.3°C  
±1.8°C  
±2.3°C  
±2.8°C  
Insulation  
Capacitance (1 KHz)  
Inductance  
Essentially non-inductive (<0.1µH)  
TOLERANCES (B is standard)  
PTF2  
H
- 1001 - D T W  
P/N DESIGNATION:  
Resistance  
Tolerance  
(@ 0°C)  
Temperature  
Tolerance  
(@ 0°C)  
RCD Type  
DIN  
43760  
Letter  
Code  
Temperature Rating: L, H, or T  
Option Codes: (leave blank if standard)  
.5 DIN  
DIN  
A
B
L
.06%  
.12%  
.2%  
.15°C  
.3°C  
4-Digit Resis. Code (at 0° C): 3 signif. digits  
& multiplier (1000=100Ω, 5000=500Ω, 1001=1KΩ)  
1.5 DIN  
2 DIN  
4 DIN  
5 DIN  
.5°C  
Tolerance @0°C: See tolerance table for codes (“B” is std)  
Packaging: B = Bulk (standard)  
C
D
E
.25%  
.5%  
.6°C  
1.3°C  
1.5°C  
Termination: W= Lead-free, Q= Tin/Lead  
(leave blank if either is acceptable)  
.6%  
-
-
-
-
RCD Components Inc, 520 E.Industrial Park Dr, Manchester, NH, USA 03109 rcdcomponents.com Tel: 603 669 0054 Fax: 603 669 5455 Email:sales@rcdcomponents.com  
FA056B Sale of this product is in accordance with GF-061. Specifications subject to change without notice.  
87  

相关型号:

PTA2H-1000-DBQ

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, RADIAL LEADED
RCD

PTA2H-1000-DBW

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
RCD

PTA2H-1000-EB

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, AXIAL LEADED
RCD

PTA2H-1000-EBQ

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, RADIAL LEADED
RCD

PTA2H-1000-EBW

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
RCD

PTA2H-1000-LB

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, AXIAL LEADED
RCD

PTA2H-1000-LBQ

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, RADIAL LEADED
RCD

PTA2H-1000-LBW

RTD Platinum Sensor, 100ohm, Cylindrical, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
RCD

PTA2H1000A

RTD Platinum Sensor
RCD

PTA2H1000C

RTD Platinum Sensor
RCD

PTA2H1000L

RTD Platinum Sensor
RCD

PTA2H100C

PTC Thermistor, Through Hole Mount
RCD