232B  
&
232E  
Only One Name Means ProTek’Tion™  
INDUSTRIAL COMPUTER DATA LINE PROTECTOR  
APPLICATIONS  
232B  
RS-232Transmission Lines  
Catagory 3 Systems  
Control & Monitoring Systems  
Analog SignalTransmissions  
Telemetry Outstations  
IEC COMPATIBILITY (EN61000-4)  
61000-4-2 (ESD): Air - 15kV, Contact - 8kV  
61000-4-4 (EFT): 40A - 5/50ns  
61000-4-5 (Surge): 8/20µs - 95A, Level 4 (Line-Gnd) & 48A, Level 4 (Line-Line)  
232E  
FEATURES  
4WIRE LINE-GROUND PROTECTION  
Designed for EIA Standard RS-232 Data Lines  
PermanentTwo-Stage, 2 Line Pair or 4 Line Protector  
Subnanosecond ResponseTime  
Automatic Reset - Does Not Interrupt Service  
Effective Against Lightning, Inductive Switching and ESD  
MECHANICAL CHARACTERISTICS  
Weight:232B - 28 grams & 232E - 142 grams (Approximate  
Flammability Rating UL 94V-0  
Device Marking:  
Case - Logo, Terminal Designations & Part Number  
Board - Logo, Date Code & Part Number  
DESCRIPTION  
The 232B/E is a two-stage transient voltage protector the provides primary and  
secondary protection against lightning, inductive switching and electrostatic discharge  
(ESD) transient threats. The first stage diverts the transient current through the ground  
terminal return path and the second stage clamps the voltage to a safe level without  
interruption of service.  
The 232B/E is designed to protect two line pairs or four (4) data lines from common-  
mode (line-to-ground) lightning or switching transients. The datalines are isolated to  
prevent near or far end cross talk problems. This product can also be used on data  
and transmission lines, security, timing and control interface circuits.  
05060.R3 11/03  
1
www.protekdevices.com  
232B  
&
232E  
DEVICE CHARACTERISTICS  
MAXIMUM RATINGS @ 25°C  
ELECTRICAL CHARACTERISTICS @ 25°C  
±25V  
MAXIMUM  
CLAMPING  
VOLTAGE  
(8/20µs)  
@ 500A  
VC  
MAXIMUM  
LINE  
THRUPUT  
RESISTANCE  
MAXIMUM  
LEAKAGE  
CURRENT  
MAXIMUM  
CAPACITANCE  
Peak Operatiing Line Voltage (VOP)  
Operating Line Current (IO)  
Maximum Transient Voltage  
Maximum Transient Current  
(8/20µs waveform)  
200mA  
10kV  
10kA/Wire  
40kA/Protector  
-55°C to 100°C  
< 1 nanosecond  
@ 25VOP  
@ 0V, 1MHz  
R
ID  
µA  
C
pF  
Operating & Storage Temperature  
Response Time  
VOLTS  
OHMS  
40  
12  
5
2000  
INSTALLATION INSTRUCTIONS  
There are five (5) terminals on both the line and equipment side of the  
232E - four data line terminals and two ground terminals. Both ground  
terminals, as shown on the label, are connected internally. A single  
ground connection is sufficient. However, it is recommended that both  
ground connections be used for a lower impedance path to earth. This  
connection can be made through the green AC power ground wire or a  
known earth ground. The ground wire should be #14 stranded wire.  
The 232B circuit board requires an edge connector interface for  
installation. The circuit board should be located at the building interface  
for incoming lines from the outside world.  
Both the 232B and 232E can be mounted on a data line circuit panel,  
which must be hard wired to the incoming data lines. Unprotected input  
lines and ground wires are to be separated from protected output lines to  
prevent electromagnetic coupling of noise from high transient currents on  
the input lines.  
Incoming data lines are cut or disconnected from the equipment to insert  
the 232E product. The line side of the terminals are to be connected to  
data lines from the outside world or lines that carry the transient threats  
into the equipment to be protected. The equipment side of the terminals  
are to be connected to the equipment to be protected . The location of  
the product should be such that these wires are as short as possible. A  
#18 or 20 gauge wire can be used for these connections.  
ProTek’s data line protector is designed with a short circuit failure mode  
to give maximum protection. A fuse, fussable link, or circuit breaker is  
recommended for each data/signal line on the input (line) side of the  
protector for those applications that require an open circuit failure mode.  
Caution: A low DC resistance ground may not be indicative of a good  
lightning ground. Lightning contains a broad spectrum of frequencies -  
up to 1 MHz. A low impedance path to ground at the transient frequen-  
cies is necessary. A ground strap is recommended or a #6 AWG  
stranded wire. For wire lengths over 1.5 meters, there may be some  
excessive line to earth potential under severe thunderstorm conditions.  
For these applications, an additional protector may be necessary at the  
equipment interface.  
Protectors should be installed at both ends of the data lines, at the point  
of entry to buildings. Use the shortest possible connection to a low  
impedance earth ground. Proper grounding and bonding are essential  
for computer installation applications.  
05060.R3 11/03  
2
www.protekdevices.com  
232B  
&
232E  
PACKAGE OUTLINE & DIMENSIONS  
232E Case Outline  
232B Board Outline  
0.50MAX (12.7mm)  
3.8MAX  
(95.5mm)  
3.25±0.015”  
(82.6mm±0.38mm)  
3.0MAX  
(76.2mm)  
2.25MAX  
(57.2mm)  
1.125”  
(30.2mm)  
1.90MAX  
(48.2mm)  
030MAX  
(7.6mm)  
Adhesive Mylar Label  
Mounting  
Hole for #8  
Screw  
Terminal Screw  
CONTINUITY  
Orientation Notch  
INPUT  
12  
13  
14  
15  
OUTPUT  
5
4
3
2
5
2
15  
12  
GND  
#6 Screws  
OUTPUT Connected to  
Transmit/Receive Circuits  
Terminal Strip  
0.07”  
(17.8mm)  
1.19MAX  
(30.2mm)  
INPUT Connected to Line From  
Outside World  
Note:  
I/O contacts spaced at 0.156”  
(3.96mm) centers.  
0.61MAX  
(15.5mm)  
ProTek Devices  
COPYRIGHT © ProTek Devices 2003  
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein  
without notice (except JEDEC).  
2929 South Fair Lane, Tempe, AZ 85282  
Tel:602-431-8101 Fax:602-431-2288  
E-Mail: sales@protekdevices.com  
Web Site: www.protekdevices.com  
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement  
concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance,  
ProTek assumes no responsibility with respect to the selection or specifications of such products.  
05060.R3 11/03  
3
www.protekdevices.com  

相关型号:

232B_10

INDUSTRIAL COMPUTER DATA LINE PROTECTOR
PROTEC

232B_12

INDUSTRIAL COMPUTER DATA LINE PROTECTOR
PROTEC

232C

Audio/RCA Connector, 2 Pole(s), Solder Lug Terminal, Jack
SWITCH

232C-868FR1

RS232 RADIO MODEM
RFSOLUTIONS

232CAM

Ready-to-use cabling call for custom lengths
ADVANTECH

232CAM10

Ready-to-use cabling call for custom lengths
ADVANTECH

232CAMR

Ready-to-use cabling call for custom lengths
ADVANTECH

232CL9R

9 Pin RS-232 to Current Loop Converter
ETC

232CL9R0900

9 Pin RS-232 to Current Loop Converter
ETC

232E

INDUSTRIAL COMPUTER DATA LINE PROTECTOR
PROTEC

232E-112-HT10W

Fixed Resistor, Wire Wound, 3W, 1100ohm, 60V, 3% +/-Tol, 10ppm/Cel,
RCD

232E-1R0-HT10

Fixed Resistor, Wire Wound, 3W, 1ohm, 60V, 3% +/-Tol, 10ppm/Cel,
RCD