PM75CSA120  
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272  
Intellimod™ Module  
Three Phase  
IGBT Inverter Output  
75 Amperes/1200 Volts  
A
B
W
R
U
Q
Y (4 TYP.)  
AB  
U
AB  
U
AD  
1234  
5678  
9
11  
13 15 17 19  
1.  
V
UPC  
11.WP  
2. UF  
O
12.VWPI  
13.VNC  
14.VNI  
15.NC  
10 12  
14 16 18  
3.  
4.  
5.  
U
V
V
P
M
AD (15 TYP.)  
UPI  
F
E
C
VPC  
Z - DIA. (4 TYP.)  
6. VF  
O
16.U  
17.V  
N
M
AA - THD (6 TYP.)  
U
7.  
8.  
9.  
V
V
V
P
N
VPI  
18.WN  
AG  
S
WPC 19.F  
O
10.WF  
O
W
V
U
W
X
X
AG  
K
J
J
P
D
2.54 MM DIA. (2 TYP.)  
Description:  
0.5 MM SQ. PIN  
(19 TYP.)  
Powerex Intellimod™ Intelligent  
Power Modules are isolated base  
modules designed for power  
switching applications operating  
at frequencies to 20kHz. Built-in  
control circuits provide optimum  
gate drive and protection for the  
IGBT and free-wheel diode  
power devices.  
AE  
T
G
H
L
N
AC  
AF  
V
TEMP  
Features:  
Complete Output Power  
Circuit  
Gate Drive Circuit  
NC  
N
W
V
U
P
Protection Logic  
– Short Circuit  
Outline Drawing and Circuit Diagram  
– Over Current  
– Over Temperature  
– Under Voltage  
Dimensions  
Inches  
4.33±0.04  
3.74±0.02  
3.50±0.04  
3.27  
Millimeters  
110.0±1.0  
95.0±0.5  
89.0±1.0  
83.0  
Dimensions  
Inches  
0.67  
0.52  
0.39  
0.32  
0.30  
0.24  
Millimeters  
17.0  
13.2  
10.0  
8.0  
A
B
C
D
E
F
S
T
Applications:  
Inverters  
UPS  
Motion/Servo Control  
Power Supplies  
U
V
2.91±0.02  
2.44  
74.0±0.5  
62.0  
W
X
7.5  
6.0  
G
H
J
1.28  
32.6  
Y
0.24 Rad.  
0.22 Dia.  
Metric M5  
0.127  
Rad. 6.0  
Dia. 5.5  
M5  
1.24  
31.6  
Z
Ordering Information:  
Example: Select the complete  
part number from the table below  
-i.e. PM75CSA120 is a 1200V,  
75 Ampere Intellimod™ Intelligent  
Power Module.  
1.02  
26.0  
AA  
AB  
AC  
AD  
AE  
AF  
AG  
K
L
0.94  
24.0  
3.22  
2.6  
0.87 +0.06/-0 22.0 +1.5/-0.0  
0.10  
M
N
P
Q
R
0.79  
20.0  
0.08  
2.0  
0.76  
19.4  
0.07  
1.8  
Type  
Current Rating  
Amperes  
V
CES  
0.75  
19.0  
0.06  
1.6  
Volts (x 10)  
0.708  
0.670  
17.98  
17.02  
0.02  
0.5  
PM  
75  
120  
511  
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272  
PM75CSA120  
Intellimod™ Module  
Three Phase IGBT Inverter Output  
75 Amperes/1200 Volts  
Absolute Maximum Ratings, T = 25°C unless otherwise specified  
j
Characteristics  
Symbol  
PM75CSA120  
-20 to 150  
-40 to 125  
-20 to 100  
17  
Units  
°C  
Power Device Junction Temperature  
Storage Temperature  
T
j
T
°C  
stg  
Case Operating Temperature  
Mounting Torque, M5 Mounting Screws  
Mounting Torque, M5 Main Terminal Screws  
Module Weight (Typical)  
T
°C  
C
in-lb  
in-lb  
Grams  
Volts  
Volts  
17  
550  
Supply Voltage Protected by OC and SC (V = 13.5 - 16.5V, Inverter Part)  
D
V
800  
CC(prot.)  
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal  
V
2500  
RMS  
Control Sector  
Supply Voltage Applied between (V  
-V  
, V  
-V  
, V  
-V  
, V -V  
)
V
20  
20  
20  
20  
Volts  
Volts  
Volts  
mA  
UP1 UPC VP1 VPC WP1 WPC N1 NC  
D
Input Voltage Applied between (U , V , W , U , V , W )  
V
CIN  
P
P
P
N
N
N
Fault Output Supply Voltage (Applied between F and V )  
V
O
C
FO  
FO  
Fault Output Current  
I
IGBT Inverter Sector  
Collector-Emitter Voltage (V = 15V, V  
D
= 15V)  
V
1200  
75  
Volts  
Amperes  
Amperes  
Volts  
CIN  
CES  
Collector Current, ±  
I
C
Peak Collector Current, ±  
I
150  
900  
1000  
500  
CP  
Supply Voltage (Applied between P - N)  
V
CC  
Supply Voltage, Surge (Applied between P - N)  
Collector Dissipation  
V
Volts  
CC(surge)  
P
Watts  
C
512  
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272  
PM75CSA120  
Intellimod™ Module  
Three Phase IGBT Inverter Output  
75 Amperes/1200 Volts  
Electrical and Mechanical Characteristics, T = 25°C unless otherwise specified  
j
Characteristics  
Symbol  
Test Conditions  
Min.  
Typ.  
Max.  
Units  
Control Sector  
Over Current Trip Level Inverter Part  
Short Circuit Trip Level Inverter Part  
Over Current Delay Time  
OC  
SC  
-20°C T 125°C  
-20°C T 125°C  
105  
170  
250  
10  
Amperes  
Amperes  
µS  
t
V
D
= 15V  
off(OC)  
OT  
Over Temperature Protection  
Trip Level  
Reset Level  
Trip Level  
111  
118  
100  
12.0  
12.5  
15  
125  
°C  
OT  
°C  
R
Supply Circuit Under Voltage Protection  
Supply Voltage  
UV  
UV  
11.5  
12.5  
Volts  
Volts  
Volts  
Reset Level  
R
V
D
Applied between V  
-V  
,
13.5  
16.5  
UP1 UPC  
V
-V  
, V  
CIN  
= 15V, V  
-V  
, V -V  
VP1 VPC WP1 WPC N1 NC  
Circuit Current  
I
V
= 15V, V  
= 15V, V -V  
40  
13  
1.5  
2.0  
15  
55  
18  
mA  
mA  
D
D
N1 NC  
V
= 15V, V  
CIN  
-V  
D
XP1 XPC  
Applied between  
U , V , W , U , V , W  
Input ON Threshold Voltage  
Input OFF Threshold Voltage  
PWM Input Frequency  
V
V
1.2  
1.7  
1.8  
2.3  
20  
Volts  
Volts  
kHz  
mA  
CIN(on)  
CIN(off)  
P
P
P
N
N
N
f
3-л Sinusoidal  
PWM  
Fault Output Current  
I
V
V
= 15V, V  
= 15V, V  
= 15V  
0.01  
15  
FO(H)  
D
FO  
FO  
I
= 15V  
10  
1.8  
mA  
FO(L)  
D
Minimum Fault Output Pulse Width  
t
V
D
= 15V  
1.0  
mS  
FO  
513  
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272  
PM75CSA120  
Intellimod™ Module  
Three Phase IGBT Inverter Output  
75 Amperes/1200 Volts  
Electrical and Mechanical Characteristics, T = 25°C unless otherwise specified  
j
Characteristics  
Symbol  
Test Conditions  
Min.  
Typ.  
Max.  
Units  
IGBT Inverter Sector  
Collector Cutoff Current  
I
V
= V  
CEX  
, T = 25°C  
1.0  
10  
mA  
mA  
CEX  
CE  
j
V
CE  
= V  
, T = 125°C  
CEX  
j
Diode Forward Voltage  
V
-I = 75A, V = 15V, V  
= 0V  
2.5  
2.5  
2.2  
3.5  
3.5  
3.2  
Volts  
Volts  
Volts  
FM  
C
D
D
D
CIN  
Collector-Emitter Saturation Voltage  
V
V
= 15V, V  
= 15V, I = 75A  
CE(sat)  
CIN  
C
V
= 15V, V  
= 15V, I = 75A,  
C
CIN  
T = 125°C  
j
Inductive Load Switching Times  
t
0.5  
1.0  
0.15  
0.4  
2.5  
0.3  
1.0  
3.0  
1.2  
µS  
µS  
µS  
µS  
µS  
on  
t
V
= 15V, V  
= 0 ~ 15V  
rr  
D
CIN  
t
V
CC  
= 600V, I = 75A  
C(on)  
C
t
T = 125°C  
2.0  
off  
j
t
0.7  
C(off)  
Thermal Characteristics  
Characteristic  
Symbol  
Condition  
Min.  
Typ.  
Max.  
0.25  
Units  
Junction to Case Thermal Resistance  
R
Each IGBT  
Each FWDi  
°C/Watt  
°C/Watt  
°C/Watt  
th(j-c)Q  
th(j-c)D  
R
0.51  
Contact Thermal Resistance  
R
th(c-f)  
Case to Fin Per Module,  
Thermal Grease Applied  
0.027  
Recommended Conditions for Use  
Characteristic  
Symbol  
Condition  
Value  
Units  
Volts  
Volts  
Supply Voltage  
V
Applied across P-N Terminals  
Applied between V -V  
0 ~ 800  
15 ± 1.5  
CC  
V
D
,
UP1 UPC  
V
-V , V  
-V  
, V  
-V  
N1 NC VP1 VPC WP1 WPC  
Input ON Voltage  
V
V
Applied between  
0 ~ 0.8  
Volts  
Volts  
kHz  
µS  
CIN(on)  
Input OFF Voltage  
PWM nput Frequency  
Minimum Dead Time  
U , V , W , U , V , W  
4.0 ~ V  
D
CIN(off)  
P
P
P
N
N
N
f
Using Application Circuit  
Input Signal  
5 ~ 20  
PWM  
t
2.5  
DEAD  
514  
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272  
PM75CSA120  
Intellimod™ Module  
Three Phase IGBT Inverter Output  
75 Amperes/1200 Volts  
SATURATION VOLTAGE  
CHARACTERISTICS (TYPICAL)  
COLLECTOR-EMITTER SATURATION  
VOLTAGE CHARACTERISTICS (TYPICAL)  
OUTPUT CHARACTERISTICS  
(TYPICAL)  
5
4
3
2
1
0
150  
3.0  
2.5  
2.0  
T = 25oC  
V
= 15V  
j
D
T = 25oC  
j
V
= 0V  
CIN  
T = 125oC  
j
125  
100  
75  
15  
V
= 17V  
D
13  
1.5  
1.0  
0.5  
0
50  
25  
I
V
= 75A  
C
= 0V  
CIN  
T = 25oC  
j
T = 125oC  
j
0
0
50  
100  
150  
150  
150  
0
12  
14  
16  
18  
20  
0
1
2
3
4
5
SUPPLY VOLTAGE, V , (VOLTS)  
COLLECTOR CURRENT, I , (AMPERES)  
COLLECTOR-EMITTER VOLTAGE, V , (VOLTS)  
CE  
D
C
SWITCHING TIME VS.  
COLLECTOR CURRENT (TYPICAL)  
SWITCHING TIME VS.  
COLLECTOR CURRENT (TYPICAL)  
REVERSE RECOVERY CURRENT VS.  
COLLECTOR CURRENT (TYPICAL)  
1
1
0
2
10  
1
10  
0
10  
10  
10  
10  
V
V
= 600V  
V
V
= 600V  
V
V
= 600V  
CC  
CC  
= 15V  
CC  
= 15V  
= 15V  
D
D
D
T = 25oC  
T = 25oC  
j
T = 25oC  
j
j
T = 125oC  
T = 125oC  
j
T = 125oC  
j
j
I
t
rr  
rr  
t
t
off  
on  
0
10  
0
10  
-1  
10  
t
c(off)  
t
c(on)  
-1  
10  
-1  
-2  
10  
10  
0
1
10  
2
10  
0
1
10  
2
10  
0
1
2
10  
10  
10  
10  
10  
COLLECTOR CURRENT, I , (AMPERES)  
C
COLLECTOR CURRENT, I , (AMPERES)  
EMITTER CURRENT, I , (AMPERES)  
C
E
OVER CURRENT TRIP LEVEL VS.  
SUPPLY VOLTAGE (TYPICAL)  
OVER CURRENT TRIP LEVEL VS.  
TEMPERATURE (TYPICAL)  
DIODE FORWARD CHARACTERISITCS  
3
140  
140  
10  
T = 25oC  
j
V
= 15V  
V
= 15V  
D
D
T = 25oC  
j
T = 125oC  
j
120  
100  
80  
60  
0
120  
100  
80  
60  
0
2
1
10  
10  
0
0.4  
10  
0.8  
1.2  
1.6  
2.0  
2.4 2.8  
0
12  
14  
16  
18  
20  
-50  
0
50  
100  
150  
DIODE FORWARD VOLTAGE, V , (VOLTS)  
SUPPLY VOLTAGE, V , (VOLTS)  
JUNCTION TEMPERATURE, T , (oC)  
F
D
j
515  
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272  
PM75CSA120  
Intellimod™ Module  
Three Phase IGBT Inverter Output  
75 Amperes/1200 Volts  
TRANSIENT THERMAL  
IMPEDANCE CHARACTERISTICS  
(IGBT)  
CONTROL SUPPLY VOLTAGE TRIP-RESET  
FAULT OUTPUT PULSE WIDTH VS.  
LEVEL TEMPERATURE DEPENDENCY  
TEMPERATURE (TYPICAL)  
(TYPICAL)  
1
0
140  
120  
100  
80  
15  
14  
13  
12  
11  
0
10  
10  
V
= 15V  
UV  
UV  
D
t
r
-1  
-2  
-3  
10  
10  
10  
60  
SINGLE PULSE  
STANDARD VALUE = R  
th(j-c)Q  
= 0.25oC/W  
0
-3  
10  
-2  
10  
-1  
10  
0
10  
1
10  
-50  
0
50  
100  
150  
-50  
0
50  
100  
150  
JUNCTION TEMPERATURE, T , (oC)  
JUNCTION TEMPERATURE, T , (oC)  
TIME, (s)  
j
j
TRANSIENT THERMAL  
IMPEDANCE CHARACTERISTICS  
(FWDi)  
1
10  
0
10  
-1  
10  
-2  
10  
10  
SINGLE PULSE  
STANDARD VALUE = R  
= 0.51oC/W  
th(j-c)D  
-3  
-3  
-2  
10  
-1  
0
10  
1
10  
10  
10  
TIME, (s)  
516  

相关型号:

PM75CSAJ120

Analog IC
ETC

PM75CSD060

Intellimod⑩ Module Three Phase IGBT Inverter Output (75 Amperes/600 Volts)
POWEREX

PM75CSD060

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CSD120

Intellimod⑩ Module Three Phase IGBT Inverter Output (75 Amperes/600 Volts)
POWEREX

PM75CSD120

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CSE060

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CSE060_05

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CSE120

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CSE120_05

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CTK060

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CVA120

FLAT-BASE TYPE INSULATED PACKAGE
MITSUBISHI

PM75CVA120

Intellimod⑩ Module Three Phase IGBT Inverter Output (75 Amperes/1200 Volts)
POWEREX